Kyle W. Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kyle W. Anderson has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey W. Hudgens
National Institute of Standards and Technology, Material Measurement Laboratory, Biomolecular Measurement Division, Gaithersburg, MD 20899, USA
9 shared publications - Elyssia S. Gallagher
Baylor University
6 shared publications - Illarion V. Turko
Biomolecular Measurement Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
6 shared publications - Irina A. Pikuleva
Department of Ophthalmology and Visual Science, Case Western Reserve University, Cleveland, OH 44106, USA
6 shared publications Natalia Mast
Department of Ophthalmology and Visual Sciences, Case Western Reserve University, Cleveland, Ohio, United States of America
6 shared publications- Ioannis Karageorgos
Institute for Bioscience and Biotechnology Research, University of Maryland, College Park, 9600 Gudelsky Drive, Rockville, MD, 20850, USA; Biomolecular Measurements Division, National Institute of Standards and Technology, 9600 Gudelsky Drive, Rockville, MD, 20850, USA
4 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
Systematic Evaluation of the Impact of Quench Conditions on Deuterium Back-Exchange in HDX-MS
Hydrogen–deuterium exchange mass spectrometry (HDX-MS) is widely used to characterize protein structure and dynamics, but accurate measurements depend on minimizing deuterium back-exchange during sample preparation. Although quench buffers typically contain denaturants and reducing agents under low pH conditions, the effects of quench solution composition and quench duration on deuterium preservation have not been systematically investigated quantitatively. Here, we quantitatively evaluated the influence of denaturant concentration, reducing agent concentration, quench pH, and quench duration on deuterium back-exchange using deuterated phosphorylase b protein and bovine serum albumin (BSA) digest peptides. Variations in denaturant and reducing agent concentrations produced only negligible changes in deuterium retention, whereas increasing the quench pH from 2.5 to 4.0 resulted in an approximately 4 percentage point decrease in average percent deuterium, identifying high quench pH as the condition exerting the greatest influence on deuterium back-exchange among the conditions investigated. Increasing quench duration from 1 to 10 min reduced average deuterium content by approximately 6 percentage points for BSA digest but only 1.6 percentage points for phosphorylase b, highlighting the protective effect of residual protein structure during the quench step. These findings provide practical guidance for selecting HDX-MS quench conditions that balance deuterium preservation with efficient protein processing while improving the accuracy and reproducibility of HDX-MS measurements.
- 4 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
Open AccessSystematic Evaluation of the Impact of Quench Conditions on Deuterium Back-Exchange in HDX-MS
Hydrogen–deuterium exchange mass spectrometry (HDX-MS) is widely used to characterize protein structure and dynamics, but accurate measurements depend on minimizing deuterium back-exchange during sample preparation. Although quench buffers typically contain denaturants and reducing agents under low pH conditions, the effects of quench solution composition and quench duration on deuterium preservation have not been systematically investigated quantitatively. Here, we quantitatively evaluated the influence of denaturant concentration, reducing agent concentration, quench pH, and quench duration on deuterium back-exchange using deuterated phosphorylase b protein and bovine serum albumin (BSA) digest peptides. Variations in denaturant and reducing agent concentrations produced only negligible changes in deuterium retention, whereas increasing the quench pH from 2.5 to 4.0 resulted in an approximately 4 percentage point decrease in average percent deuterium, identifying high quench pH as the condition exerting the greatest influence on deuterium back-exchange among the conditions investigated. Increasing quench duration from 1 to 10 min reduced average deuterium content by approximately 6 percentage points for BSA digest but only 1.6 percentage points for phosphorylase b, highlighting the protective effect of residual protein structure during the quench step. These findings provide practical guidance for selecting HDX-MS quench conditions that balance deuterium preservation with efficient protein processing while improving the accuracy and reproducibility of HDX-MS measurements.
- 23 December 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 340-345
Rapid Removal of IgG1 Carryover on Protease Column Using Protease-Safe Wash Solutions Delivered with LC Pump for HDX-MS Systems
Sample carryover is a common problem in hydrogen-deuterium exchange mass spectrometry, particularly because immobilized protease columns cannot withstand the high organic solvent concentrations typically used in liquid chromatography-mass spectrometry (LC-MS) for cleaning. Conventional cleaning methods using injections of guanidine HCl still suffer from carryover and may require four blanks after each sample run to fully remove carryover. We have implemented an additional LC pump to deliver customized wash solutions to protease and enzyme columns, and the associated LC capillaries to eliminate carryover. Pump-based washing using the protease-safe wash solutions tested herein was able to fully remove carryover with only one blank run. FOS-choline-12 was found to be the most effective component in wash solutions and even performed well alone at 0.1% volume concentration. Since the protease column washing is performed concurrently during the analytical gradient within a sample run, subsequent blank runs could be reduced from four to one and total run time could be reduced by up to 60%. Savings in total run time could more than double the productivity of data acquisition, which is imperative for pandemic preparedness and for acceleration of biotherapeutics development.
- 23 December 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (2) , 340-345
Rapid Removal of IgG1 Carryover on Protease Column Using Protease-Safe Wash Solutions Delivered with LC Pump for HDX-MS Systems
Sample carryover is a common problem in hydrogen-deuterium exchange mass spectrometry, particularly because immobilized protease columns cannot withstand the high organic solvent concentrations typically used in liquid chromatography-mass spectrometry (LC-MS) for cleaning. Conventional cleaning methods using injections of guanidine HCl still suffer from carryover and may require four blanks after each sample run to fully remove carryover. We have implemented an additional LC pump to deliver customized wash solutions to protease and enzyme columns, and the associated LC capillaries to eliminate carryover. Pump-based washing using the protease-safe wash solutions tested herein was able to fully remove carryover with only one blank run. FOS-choline-12 was found to be the most effective component in wash solutions and even performed well alone at 0.1% volume concentration. Since the protease column washing is performed concurrently during the analytical gradient within a sample run, subsequent blank runs could be reduced from four to one and total run time could be reduced by up to 60%. Savings in total run time could more than double the productivity of data acquisition, which is imperative for pandemic preparedness and for acceleration of biotherapeutics development.
- Open Access
- 21 October 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Rapid removal of IgG1 carryover on protease column using protease-safe wash solutions delivered with LC pump for HDX-MS systems
Sample carryover is a common problem in hydrogen-deuterium exchange mass spectrometry, particularly because immobilized protease columns cannot withstand the high organic solvent concentrations typically used in liquid chromatography mass spectrometry (LC-MS) for cleaning. Conventional cleaning methods using injections of guanidine HCl still suffer from carryover and may require four blanks after each sample run to fully remove carryover. We have implemented an additional LC pump to deliver customized wash solutions to protease and enzyme columns and the associated LC capillaries to eliminate carryover. Pump-based washing using the protease-safe wash solutions tested herein were able to fully remove carryover with only one blank run. FOS-choline-12 was found to be the most effective component in wash solutions and even performed well alone at 0.1 % volume concentration. Since the protease column washing is performed concurrently during the analytical gradient within a sample run, subsequent blank runs could be reduced from four to one and total run time could be reduced by up to 60 %. Savings in total run time could more than double the productivity of data acquisition, which is imperative for pandemic preparedness and for acceleration of biotherapeutics development.
- 21 October 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessRapid removal of IgG1 carryover on protease column using protease-safe wash solutions delivered with LC pump for HDX-MS systems
Sample carryover is a common problem in hydrogen-deuterium exchange mass spectrometry, particularly because immobilized protease columns cannot withstand the high organic solvent concentrations typically used in liquid chromatography mass spectrometry (LC-MS) for cleaning. Conventional cleaning methods using injections of guanidine HCl still suffer from carryover and may require four blanks after each sample run to fully remove carryover. We have implemented an additional LC pump to deliver customized wash solutions to protease and enzyme columns and the associated LC capillaries to eliminate carryover. Pump-based washing using the protease-safe wash solutions tested herein were able to fully remove carryover with only one blank run. FOS-choline-12 was found to be the most effective component in wash solutions and even performed well alone at 0.1 % volume concentration. Since the protease column washing is performed concurrently during the analytical gradient within a sample run, subsequent blank runs could be reduced from four to one and total run time could be reduced by up to 60 %. Savings in total run time could more than double the productivity of data acquisition, which is imperative for pandemic preparedness and for acceleration of biotherapeutics development.
- Open Access
- 6 November 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (12) , 2672-2679
Hydrophilic Interaction Liquid Chromatography at Subzero Temperature for Hydrogen–Deuterium Exchange Mass Spectrometry
Chromatographic separations at subzero temperature significantly improve the precision of back-exchange-corrected hydrogen-deuterium exchange mass spectrometry (HDX-MS) determinations. Our previously reported dual-enzyme HDX-MS analysis instrument used reversed phase liquid chromatography (RPLC) at -30 °C, but high backpressures limited flow rates and required materials and equipment rated for very high pressures. Here, we report the design and performance of a dual-enzyme HDX-MS analysis instrument comprising a RPLC trap column and a hydrophilic interaction liquid chromatography (HILIC) analytical column in a two-dimensional RPLC-HILIC configuration at subzero temperature. During operation at -30 °C, the HILIC column manifests greatly reduced backpressure, which enables faster analytical flow rates and the use of materials rated for lower maximum pressures. The average peptide eluted from a HILIC column during a 40 min gradient at -30 °C contained ≈13% more deuterium than peptides eluted from a tandem RPLC-RPLC apparatus using a conventional 8 min gradient at 0 °C. A subset of peptides eluted from the HILIC apparatus contained ≈24% more deuterium.
- 6 November 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (12) , 2672-2679
Open AccessHydrophilic Interaction Liquid Chromatography at Subzero Temperature for Hydrogen–Deuterium Exchange Mass Spectrometry
Chromatographic separations at subzero temperature significantly improve the precision of back-exchange-corrected hydrogen-deuterium exchange mass spectrometry (HDX-MS) determinations. Our previously reported dual-enzyme HDX-MS analysis instrument used reversed phase liquid chromatography (RPLC) at -30 °C, but high backpressures limited flow rates and required materials and equipment rated for very high pressures. Here, we report the design and performance of a dual-enzyme HDX-MS analysis instrument comprising a RPLC trap column and a hydrophilic interaction liquid chromatography (HILIC) analytical column in a two-dimensional RPLC-HILIC configuration at subzero temperature. During operation at -30 °C, the HILIC column manifests greatly reduced backpressure, which enables faster analytical flow rates and the use of materials rated for lower maximum pressures. The average peptide eluted from a HILIC column during a 40 min gradient at -30 °C contained ≈13% more deuterium than peptides eluted from a tandem RPLC-RPLC apparatus using a conventional 8 min gradient at 0 °C. A subset of peptides eluted from the HILIC apparatus contained ≈24% more deuterium.
- Open Access
- 19 October 2023
- Published by American Chemical Society (ACS) in JACS Au
- Vol. 3 (12) , 3345-3365
Host Defense Peptide Piscidin and Yeast-Derived Glycolipid Exhibit Synergistic Antimicrobial Action through Concerted Interactions with Membranes
Developing new antimicrobials as alternatives to conventional antibiotics has become an urgent race to eradicate drug-resistant bacteria and to save human lives. Conventionally, antimicrobial molecules are studied independently even though they can be cosecreted in vivo. In this research, we investigate two classes of naturally derived antimicrobials: sophorolipid (SL) esters as modified yeast-derived glycolipid biosurfactants that feature high biocompatibility and low production cost; piscidins, which are host defense peptides (HDPs) from fish. While HDPs such as piscidins target the membrane of pathogens, and thus result in low incidence of resistance, SLs are not well understood on a mechanistic level. Here, we demonstrate that combining SL-hexyl ester (SL-HE) with subinhibitory concentration of piscidins 1 (P1) and 3 (P3) stimulates strong antimicrobial synergy, potentiating a promising therapeutic window. Permeabilization assays and biophysical studies employing circular dichroism, NMR, mass spectrometry, and X-ray diffraction are performed to investigate the mechanism underlying this powerful synergy. We reveal four key mechanistic features underlying the synergistic action: (1) P1/3 binds to SL-HE aggregates, becoming α-helical; (2) piscidin-glycolipid assemblies synergistically accumulate on membranes; (3) SL-HE used alone or bound to P1/3 associates with phospholipid bilayers where it induces defects; (4) piscidin-glycolipid complexes disrupt the bilayer structure more dramatically and differently than either compound alone, with phase separation occurring when both agents are present. Overall, dramatic enhancement in antimicrobial activity is associated with the use of two membrane-active agents, with the glycolipid playing the roles of prefolding the peptide, coordinating the delivery of both agents to bacterial surfaces, recruiting the peptide to the pathogenic membranes, and supporting membrane disruption by the peptide. Given that SLs are ubiquitously and safely used in consumer products, the SL/peptide formulation engineered and mechanistically characterized in this study could represent fertile ground to develop novel synergistic agents against drug-resistant bacteria.
- 19 October 2023
- Published by American Chemical Society (ACS) in JACS Au
- Vol. 3 (12) , 3345-3365
Open AccessHost Defense Peptide Piscidin and Yeast-Derived Glycolipid Exhibit Synergistic Antimicrobial Action through Concerted Interactions with Membranes
Developing new antimicrobials as alternatives to conventional antibiotics has become an urgent race to eradicate drug-resistant bacteria and to save human lives. Conventionally, antimicrobial molecules are studied independently even though they can be cosecreted in vivo. In this research, we investigate two classes of naturally derived antimicrobials: sophorolipid (SL) esters as modified yeast-derived glycolipid biosurfactants that feature high biocompatibility and low production cost; piscidins, which are host defense peptides (HDPs) from fish. While HDPs such as piscidins target the membrane of pathogens, and thus result in low incidence of resistance, SLs are not well understood on a mechanistic level. Here, we demonstrate that combining SL-hexyl ester (SL-HE) with subinhibitory concentration of piscidins 1 (P1) and 3 (P3) stimulates strong antimicrobial synergy, potentiating a promising therapeutic window. Permeabilization assays and biophysical studies employing circular dichroism, NMR, mass spectrometry, and X-ray diffraction are performed to investigate the mechanism underlying this powerful synergy. We reveal four key mechanistic features underlying the synergistic action: (1) P1/3 binds to SL-HE aggregates, becoming α-helical; (2) piscidin-glycolipid assemblies synergistically accumulate on membranes; (3) SL-HE used alone or bound to P1/3 associates with phospholipid bilayers where it induces defects; (4) piscidin-glycolipid complexes disrupt the bilayer structure more dramatically and differently than either compound alone, with phase separation occurring when both agents are present. Overall, dramatic enhancement in antimicrobial activity is associated with the use of two membrane-active agents, with the glycolipid playing the roles of prefolding the peptide, coordinating the delivery of both agents to bacterial surfaces, recruiting the peptide to the pathogenic membranes, and supporting membrane disruption by the peptide. Given that SLs are ubiquitously and safely used in consumer products, the SL/peptide formulation engineered and mechanistically characterized in this study could represent fertile ground to develop novel synergistic agents against drug-resistant bacteria.
- Open Access
- 21 August 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (35) , 12313-12323
Particle Metrology Approach to Understanding How Storage Conditions Affect Long-Term Liposome Stability
Lipid nanoparticles are a generic type of nanomaterial with broad applicability in medicine as drug delivery vehicles. Liposomes are a subtype of lipid nanoparticles and, as a therapeutic platform, can be loaded with a genetic material or pharmaceutical agents for use as drug treatments. An open question for these types of lipid nanoparticles is what factor(s) affect the long-term stability of the particles. The stability of the particle is of great interest to understand and predict the effective shelf-life and storage requirements. In this report, we detail a one-year study of liposome stability as a function of lipid composition, buffer composition/pH, and storage temperature. This was done in aqueous solution without freezing. The effect of lipid composition is shown to be a critical factor when evaluating stability of the measured particle size and number concentration. Other factors (i.e., storage temperature and buffer pH/composition) were shown to be less critical but still have some effect. The stability of these particles informs formulation and optimal storage requirements and assists with future developmental planning of a NIST liposome-based reference material. This work also highlights the complex nature of long-term soft particle storage in biopharmaceutical applications.
- 21 August 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (35) , 12313-12323
Open AccessParticle Metrology Approach to Understanding How Storage Conditions Affect Long-Term Liposome Stability
Lipid nanoparticles are a generic type of nanomaterial with broad applicability in medicine as drug delivery vehicles. Liposomes are a subtype of lipid nanoparticles and, as a therapeutic platform, can be loaded with a genetic material or pharmaceutical agents for use as drug treatments. An open question for these types of lipid nanoparticles is what factor(s) affect the long-term stability of the particles. The stability of the particle is of great interest to understand and predict the effective shelf-life and storage requirements. In this report, we detail a one-year study of liposome stability as a function of lipid composition, buffer composition/pH, and storage temperature. This was done in aqueous solution without freezing. The effect of lipid composition is shown to be a critical factor when evaluating stability of the measured particle size and number concentration. Other factors (i.e., storage temperature and buffer pH/composition) were shown to be less critical but still have some effect. The stability of these particles informs formulation and optimal storage requirements and assists with future developmental planning of a NIST liposome-based reference material. This work also highlights the complex nature of long-term soft particle storage in biopharmaceutical applications.
- Open Access
- 22 June 2022
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 33 (7) , 1282-1292
Chromatography at −30 °C for Reduced Back-Exchange, Reduced Carryover, and Improved Dynamic Range for Hydrogen–Deuterium Exchange Mass Spectrometry
For hydrogen-deuterium exchange mass spectrometry (HDX-MS) to have an increased role in quality control of biopharmaceuticals, H for D back-exchange occurring during protein analyses should be minimized to promote greater reproducibility. Standard HDX-MS analysis systems that digest proteins and separate peptides at pH 2.7 and 0 °C can lose >30% of the deuterium marker within 15 min of sample injection. This report describes the architecture and performance of a dual-enzyme, HDX-MS instrument that conducts liquid chromatography (LC) separations at subzero temperature, thereby reducing back-exchange and supporting longer LC separations with improved chromatographic resolution. LC separations of perdeuterated, fully reduced, iodoacetamide-treated BSA protein digest standard peptides were performed at 0, -10, -20, and -30 °C in ethylene glycol (EG)/H2O mixtures. Analyses conducted at -20 and -30 °C produced similar results. After subtracting for deuterium retained in arginine side chains, the average peptide eluted during a 40 min gradient contained ≈16% more deuterium than peptides eluted with a conventional 8 min gradient at 0 °C. A subset of peptides exhibited ≈26% more deuterium. Although chromatographic peaks shift with EG concentration and temperature, the apparatus elutes unbroadened LC peaks. Electrospray ion intensity does not decline with increasing EG fraction. To minimize bias from sample carryover, the fluidic circuits allow flush and backflush cleaning of all enzyme and LC columns. The system can perform LC separations and clean enzyme columns simultaneously. Temperature zones are controlled ±0.058 °C. The potential of increased sensitivity by mixing acetonitrile with the analytical column effluent was also examined.
- 22 June 2022
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 33 (7) , 1282-1292
Open AccessChromatography at −30 °C for Reduced Back-Exchange, Reduced Carryover, and Improved Dynamic Range for Hydrogen–Deuterium Exchange Mass Spectrometry
For hydrogen-deuterium exchange mass spectrometry (HDX-MS) to have an increased role in quality control of biopharmaceuticals, H for D back-exchange occurring during protein analyses should be minimized to promote greater reproducibility. Standard HDX-MS analysis systems that digest proteins and separate peptides at pH 2.7 and 0 °C can lose >30% of the deuterium marker within 15 min of sample injection. This report describes the architecture and performance of a dual-enzyme, HDX-MS instrument that conducts liquid chromatography (LC) separations at subzero temperature, thereby reducing back-exchange and supporting longer LC separations with improved chromatographic resolution. LC separations of perdeuterated, fully reduced, iodoacetamide-treated BSA protein digest standard peptides were performed at 0, -10, -20, and -30 °C in ethylene glycol (EG)/H2O mixtures. Analyses conducted at -20 and -30 °C produced similar results. After subtracting for deuterium retained in arginine side chains, the average peptide eluted during a 40 min gradient contained ≈16% more deuterium than peptides eluted with a conventional 8 min gradient at 0 °C. A subset of peptides exhibited ≈26% more deuterium. Although chromatographic peaks shift with EG concentration and temperature, the apparatus elutes unbroadened LC peaks. Electrospray ion intensity does not decline with increasing EG fraction. To minimize bias from sample carryover, the fluidic circuits allow flush and backflush cleaning of all enzyme and LC columns. The system can perform LC separations and clean enzyme columns simultaneously. Temperature zones are controlled ±0.058 °C. The potential of increased sensitivity by mixing acetonitrile with the analytical column effluent was also examined.
- Open Access
- 1 January 2022
- Published by Elsevier in Journal of Molecular Biology
- Vol. 434 (2) , 167391
HDX-MS and MD Simulations Provide Evidence for Stabilization of the IgG1—FcγRIa (CD64a) Immune Complex Through Intermolecular Glycoprotein Bonds
- 1 January 2022
- Published by Elsevier in Journal of Molecular Biology
- Vol. 434 (2) , 167391
Open AccessHDX-MS and MD Simulations Provide Evidence for Stabilization of the IgG1—FcγRIa (CD64a) Immune Complex Through Intermolecular Glycoprotein Bonds
- Open Access
- 17 June 2021
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 126, 126010
Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the FcγRIa (CD64) Receptor
This document presents hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, FcγRIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.
- 17 June 2021
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 126, 126010
Open AccessDataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the FcγRIa (CD64) Receptor
This document presents hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, FcγRIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.
- 2 May 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (11) , 7336-7345
Interlaboratory Comparison of Hydrogen–Deuterium Exchange Mass Spectrometry Measurements of the Fab Fragment of NISTmAb
Hydrogen–deuterium exchange mass spectrometry (HDX-MS) is an established, powerful tool for investigating protein–ligand interactions, protein folding, and protein dynamics. However, HDX-MS is still an emergent tool for quality control of biopharmaceuticals and for establishing dynamic similarity between a biosimilar and an innovator therapeutic. Because industry will conduct quality control and similarity measurements over a product lifetime and in multiple locations, an understanding of HDX-MS reproducibility is critical. To determine the reproducibility of continuous-labeling, bottom-up HDX-MS measurements, the present interlaboratory comparison project evaluated deuterium uptake data from the Fab fragment of NISTmAb reference material (PDB: 5K8A) from 15 laboratories. Laboratories reported ∼89 800 centroid measurements for 430 proteolytic peptide sequences of the Fab fragment (∼78 900 centroids), giving ∼100% coverage, and ∼10 900 centroid measurements for 77 peptide sequences of the Fc fragment. Nearly half of peptide sequences are unique to the reporting laboratory, and only two sequences are reported by all laboratories. The majority of the laboratories (87%) exhibited centroid mass laboratory repeatability precisions of ⟨sLab⟩ ≤ (0.15 ± 0.01) Da (1σx̅). All laboratories achieved ⟨sLab⟩ ≤ 0.4 Da. For immersions of protein at THDX = (3.6 to 25) °C and for D2O exchange times of tHDX = (30 s to 4 h) the reproducibility of back-exchange corrected, deuterium uptake measurements for the 15 laboratories is σreproducibility15 Laboratories(tHDX) = (9.0 ± 0.9) % (1σ). A nine laboratory cohort that immersed samples at THDX = 25 °C exhibited reproducibility of σreproducibility25C cohort(tHDX) = (6.5 ± 0.6) % for back-exchange corrected, deuterium uptake measurements.
- 2 May 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (11) , 7336-7345
Interlaboratory Comparison of Hydrogen–Deuterium Exchange Mass Spectrometry Measurements of the Fab Fragment of NISTmAb
Hydrogen–deuterium exchange mass spectrometry (HDX-MS) is an established, powerful tool for investigating protein–ligand interactions, protein folding, and protein dynamics. However, HDX-MS is still an emergent tool for quality control of biopharmaceuticals and for establishing dynamic similarity between a biosimilar and an innovator therapeutic. Because industry will conduct quality control and similarity measurements over a product lifetime and in multiple locations, an understanding of HDX-MS reproducibility is critical. To determine the reproducibility of continuous-labeling, bottom-up HDX-MS measurements, the present interlaboratory comparison project evaluated deuterium uptake data from the Fab fragment of NISTmAb reference material (PDB: 5K8A) from 15 laboratories. Laboratories reported ∼89 800 centroid measurements for 430 proteolytic peptide sequences of the Fab fragment (∼78 900 centroids), giving ∼100% coverage, and ∼10 900 centroid measurements for 77 peptide sequences of the Fc fragment. Nearly half of peptide sequences are unique to the reporting laboratory, and only two sequences are reported by all laboratories. The majority of the laboratories (87%) exhibited centroid mass laboratory repeatability precisions of ⟨sLab⟩ ≤ (0.15 ± 0.01) Da (1σx̅). All laboratories achieved ⟨sLab⟩ ≤ 0.4 Da. For immersions of protein at THDX = (3.6 to 25) °C and for D2O exchange times of tHDX = (30 s to 4 h) the reproducibility of back-exchange corrected, deuterium uptake measurements for the 15 laboratories is σreproducibility15 Laboratories(tHDX) = (9.0 ± 0.9) % (1σ). A nine laboratory cohort that immersed samples at THDX = 25 °C exhibited reproducibility of σreproducibility25C cohort(tHDX) = (6.5 ± 0.6) % for back-exchange corrected, deuterium uptake measurements.