Aristotelis Dosis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aristotelis Dosis has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Bello
National University of Singapore
9 shared publications A. Darzi
Imperial College London
6 shared publicationsY. Munz
St. Mary's Hospital
4 shared publicationsAra Darzi
From the *Department of Biosurgery & Surgical Technology, Imperial College London, UK; †Department of Surgical Gastroenterology, Glostrup University Hospital, Glostrup, Denmark; and ‡Department of Surgery, Western Pennsylvania Hospital, Pittsburgh, PA
3 shared publicationsDuncan Gillies
3 shared publications- Juan David Hernandez
Department of Surgery, Fundación Santa Fé de Bogotá, Bogotá, Colombia
3 shared publications
Latest Publications
- 1 June 2007
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 245 (6) , 992-999
An Evaluation of the Feasibility, Validity, and Reliability of Laparoscopic Skills Assessment in the Operating Room
To assess the use of a synchronized video-based motion tracking device for objective, instant, and automated assessment of laparoscopic skill in the operating room. The assessment of technical skills is fundamental to recognition of proficient surgical practice. It is necessary to demonstrate the validity, reliability, and feasibility of any tool to be applied for objective measurement of performance. Nineteen subjects, divided into 13 experienced (performed >100 laparoscopic cholecystectomies) and 6 inexperienced (performed <10 LCs) surgeons completed LCs on 53 patients who all had a diagnosis of biliary colic. Each procedure was recorded with the ROVIMAS video-based motion tracking device to provide an objective measure of the surgeon's dexterity. Each video was also rated by 2 experienced observers on a previously validated operative assessment scale. There were significant differences for motion tracking parameters between the 2 groups of surgeons for the Calot triangle dissection part of procedure for time taken (P = 0.002), total path length (P = 0.026), and number of movements (P = 0.005). Both motion tracking and video-based assessment displayed intertest reliability, and there were good correlations between the 2 modes of assessment (r = 0.4 to 0.7, P < 0.01). An instant, objective, valid, and reliable mode of assessment of laparoscopic performance in the operating room has been defined. This may serve to reduce the time taken for technical skills assessment, and subsequently lead to accurate and efficient audit and credentialing of surgeons for independent practice.
- 1 June 2007
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 245 (6) , 992-999
An Evaluation of the Feasibility, Validity, and Reliability of Laparoscopic Skills Assessment in the Operating Room
To assess the use of a synchronized video-based motion tracking device for objective, instant, and automated assessment of laparoscopic skill in the operating room. The assessment of technical skills is fundamental to recognition of proficient surgical practice. It is necessary to demonstrate the validity, reliability, and feasibility of any tool to be applied for objective measurement of performance. Nineteen subjects, divided into 13 experienced (performed >100 laparoscopic cholecystectomies) and 6 inexperienced (performed <10 LCs) surgeons completed LCs on 53 patients who all had a diagnosis of biliary colic. Each procedure was recorded with the ROVIMAS video-based motion tracking device to provide an objective measure of the surgeon's dexterity. Each video was also rated by 2 experienced observers on a previously validated operative assessment scale. There were significant differences for motion tracking parameters between the 2 groups of surgeons for the Calot triangle dissection part of procedure for time taken (P = 0.002), total path length (P = 0.026), and number of movements (P = 0.005). Both motion tracking and video-based assessment displayed intertest reliability, and there were good correlations between the 2 modes of assessment (r = 0.4 to 0.7, P < 0.01). An instant, objective, valid, and reliable mode of assessment of laparoscopic performance in the operating room has been defined. This may serve to reduce the time taken for technical skills assessment, and subsequently lead to accurate and efficient audit and credentialing of surgeons for independent practice.
- Open Access
- 1 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (2) , 339
Motion tracking systems for assessment of surgical skill
- 1 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (2) , 339
Open AccessMotion tracking systems for assessment of surgical skill
- 1 March 2005
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 140 (3) , 293-299
Synchronized Video and Motion Analysis for the Assessment of Procedures in the Operating Theater
Research from JAMA Surgery — Synchronized Video and Motion Analysis for the Assessment of Procedures in the Operating Theater
- 1 March 2005
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 140 (3) , 293-299
Synchronized Video and Motion Analysis for the Assessment of Procedures in the Operating Theater
Research from JAMA Surgery — Synchronized Video and Motion Analysis for the Assessment of Procedures in the Operating Theater
- 1 January 2005
- Vol. 111, 115-22
Laparoscopic task recognition using Hidden Markov Models.
Surgical skills assessment has been paid increased attention over the last few years. Stochastic models such as Hidden Markov Models have recently been adapted to surgery to discriminate levels of expertise. Based on our previous work combining synchronized video and motion analysis we present preliminary results of a HMM laparoscopic task recognizer which aims to model hand manipulations and to identify and recognize simple surgical tasks.
- 1 January 2005
- Vol. 111, 115-22
Laparoscopic task recognition using Hidden Markov Models.
Surgical skills assessment has been paid increased attention over the last few years. Stochastic models such as Hidden Markov Models have recently been adapted to surgery to discriminate levels of expertise. Based on our previous work combining synchronized video and motion analysis we present preliminary results of a HMM laparoscopic task recognizer which aims to model hand manipulations and to identify and recognize simple surgical tasks.
- 11 October 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (11) , 1608-1612
Bimodal assessment of laparoscopic suturing skills: Construct and concurrent validity
The assessment of technical skills should provide objective feedback and judge suitability of progress during training. The aim of this study was to validate two objective assessment techniques for laparoscopic suturing and demonstrate a correlation between them. Six experts, seven surgeons skilled in laparoscopic suturing, and 13 with no laparoscopic suturing skills were asked to place two or three intracorporeal sutures on a synthetic suture pad. The latter group was given video-based instructions prior to the execution of the sutures. Ergonomic conditions were standardized for all subjects. The procedures were recorded on videotape and two blinded observers rated the first suture of each subject on a 29-point checklist. A motion analysis system, Imperial College Surgical Assessment Device, was used to assess psychomotor skills. There was a significant difference in the time taken (p = 0.000) and total path length (p = 0.000) per suture across the groups. There were also a significant difference in the total checklist score (p = 0.000) and its individual categories. The was a strong correlation between the total path length and the total checklist score (coefficient, 0.78; p < 0.001). A combination of the motion analysis system and the checklist would make the process of formative feedback during the learning of intracorporeal suturing objective and comprehensive.
- 11 October 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (11) , 1608-1612
Bimodal assessment of laparoscopic suturing skills: Construct and concurrent validity
The assessment of technical skills should provide objective feedback and judge suitability of progress during training. The aim of this study was to validate two objective assessment techniques for laparoscopic suturing and demonstrate a correlation between them. Six experts, seven surgeons skilled in laparoscopic suturing, and 13 with no laparoscopic suturing skills were asked to place two or three intracorporeal sutures on a synthetic suture pad. The latter group was given video-based instructions prior to the execution of the sutures. Ergonomic conditions were standardized for all subjects. The procedures were recorded on videotape and two blinded observers rated the first suture of each subject on a 29-point checklist. A motion analysis system, Imperial College Surgical Assessment Device, was used to assess psychomotor skills. There was a significant difference in the time taken (p = 0.000) and total path length (p = 0.000) per suture across the groups. There were also a significant difference in the total checklist score (p = 0.000) and its individual categories. The was a strong correlation between the total path length and the total checklist score (coefficient, 0.78; p < 0.001). A combination of the motion analysis system and the checklist would make the process of formative feedback during the learning of intracorporeal suturing objective and comprehensive.
- 6 April 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (5) , 790-795
Dexterity enhancement with robotic surgery
The aim of this study was to quantify the extent of dexterity enhancement in robotic surgery as compared to laparoscopic surgery.
- 6 April 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (5) , 790-795
Dexterity enhancement with robotic surgery
The aim of this study was to quantify the extent of dexterity enhancement in robotic surgery as compared to laparoscopic surgery.
- 1 April 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (4) , 611-616
The benfits of stereoscopic vision in robotic-assisted performance on bench models
Background: Previous studies have failed to establish clear advantages for the use of stereoscopic visualization systems in minimal-access surgery. The aim of this study was to objectively assess whether stereoscopic visualization improves performance on bench models using the da Vinci robotic system. Methods: Eleven surgeons carried out a series of four tasks. Positional data streamed from the da Vinci system was analyzed by means of a previously validated custom-designed software-package. An independent blinded observer scored errors. Statistical analysis included the Wilcoxon signed rank test. A p < 0.05 was deemed significant. Results: We found significant improvements in all tasks and for all parameters (p < 0.05). In addition, a significantly lower number of errors was scored using the stereoscopic mode as compared to the standard two-dimensional image (p < 0.001). Conclusion: Robotic-assisted performance on bench models is more efficient and accurate using stereoscopic visualization.
- 1 April 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (4) , 611-616
The benfits of stereoscopic vision in robotic-assisted performance on bench models
Background: Previous studies have failed to establish clear advantages for the use of stereoscopic visualization systems in minimal-access surgery. The aim of this study was to objectively assess whether stereoscopic visualization improves performance on bench models using the da Vinci robotic system. Methods: Eleven surgeons carried out a series of four tasks. Positional data streamed from the da Vinci system was analyzed by means of a previously validated custom-designed software-package. An independent blinded observer scored errors. Statistical analysis included the Wilcoxon signed rank test. A p < 0.05 was deemed significant. Results: We found significant improvements in all tasks and for all parameters (p < 0.05). In addition, a significantly lower number of errors was scored using the stereoscopic mode as compared to the standard two-dimensional image (p < 0.001). Conclusion: Robotic-assisted performance on bench models is more efficient and accurate using stereoscopic visualization.
- 1 March 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (3) , 372-378
Qualitative and quantitative analysis of the learning curve of a simulated surgical task on the da Vinci system
Robotic telemanipulation systems provide solutions to the problems of less dexterity and visual constraints of minimally invasive surgery (MIS). However, their influence over surgeons’ dexterity and learning curve needs to be assessed. We present motion analysis as an objective method to measure performance and learning progress. Thirteen surgeons completed five synthetic small bowel anastomoses using the da Vinci system. Objective Structured Assessment of Technical Skills (OSATS) allowed qualitative analysis. Quantitative analysis used API software of the system to retrieve real-time robotic signal data of time, path length, and number of movements. Wilcoxon signed ranks test was used for statistical analysis. A p value p < 0.02, Cronbach’s alpha = 0.894). Paired data of motion analysis for attempts 1 vs 5 showed significant change: time taken 3507 sec and 2287 sec (p < 0.008), total number of movements 2411 and 1387 (p = 0.01), total path length 21,630 cm and 13,941 cm (p = 0.01). A rapid learning curve to a competent level using the da Vinci system is possible aided by the system’s intuitive motion. Motion analysis is a useful tool to measure performance in the da Vinci system compared to OSATS and time alone.
- 1 March 2004
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (3) , 372-378
Qualitative and quantitative analysis of the learning curve of a simulated surgical task on the da Vinci system
Robotic telemanipulation systems provide solutions to the problems of less dexterity and visual constraints of minimally invasive surgery (MIS). However, their influence over surgeons’ dexterity and learning curve needs to be assessed. We present motion analysis as an objective method to measure performance and learning progress. Thirteen surgeons completed five synthetic small bowel anastomoses using the da Vinci system. Objective Structured Assessment of Technical Skills (OSATS) allowed qualitative analysis. Quantitative analysis used API software of the system to retrieve real-time robotic signal data of time, path length, and number of movements. Wilcoxon signed ranks test was used for statistical analysis. A p value p < 0.02, Cronbach’s alpha = 0.894). Paired data of motion analysis for attempts 1 vs 5 showed significant change: time taken 3507 sec and 2287 sec (p < 0.008), total number of movements 2411 and 1387 (p = 0.01), total path length 21,630 cm and 13,941 cm (p = 0.01). A rapid learning curve to a competent level using the da Vinci system is possible aided by the system’s intuitive motion. Motion analysis is a useful tool to measure performance in the da Vinci system compared to OSATS and time alone.
- 1 January 2004
- Vol. 98, 82-8
Real-time synchronization of kinematic and video data for the comprehensive assessment of surgical skills.
Surgical dexterity in operating theatres has traditionally been assessed subjectively. Electromagnetic (EM) motion tracking systems such as the Imperial College Surgical Assessment Device (ICSAD) have been shown to produce valid and accurate objective measures of surgical skill. To allow for video integration we have modified the data acquisition and built it within the ROVIMAS analysis software. We then used ActiveX 9.0 DirectShow video capturing and the system clock as a time stamp for the synchronized concurrent acquisition of kinematic data and video frames. Interactive video/motion data browsing was implemented to allow the user to concentrate on frames exhibiting certain kinematic properties that could result in operative errors. We exploited video-data synchronization to calculate the camera visual hull by identifying all 3D vertices using the ICSAD electromagnetic sensors. We also concentrated on high velocity peaks as a means of identifying potential erroneous movements to be confirmed by studying the corresponding video frames. The outcome of the study clearly shows that the kinematic data are precisely synchronized with the video frames and that the velocity peaks correspond to large and sudden excursions of the instrument tip. We validated the camera visual hull by both video and geometrical kinematic analysis and we observed that graphs containing fewer sudden velocity peaks are less likely to have erroneous movements. This work presented further developments to the well-established ICSAD dexterity analysis system. Synchronized real-time motion and video acquisition provides a comprehensive assessment solution by combining quantitative motion analysis tools and qualitative targeted video scoring.
- 1 January 2004
- Vol. 98, 82-8
Real-time synchronization of kinematic and video data for the comprehensive assessment of surgical skills.
Surgical dexterity in operating theatres has traditionally been assessed subjectively. Electromagnetic (EM) motion tracking systems such as the Imperial College Surgical Assessment Device (ICSAD) have been shown to produce valid and accurate objective measures of surgical skill. To allow for video integration we have modified the data acquisition and built it within the ROVIMAS analysis software. We then used ActiveX 9.0 DirectShow video capturing and the system clock as a time stamp for the synchronized concurrent acquisition of kinematic data and video frames. Interactive video/motion data browsing was implemented to allow the user to concentrate on frames exhibiting certain kinematic properties that could result in operative errors. We exploited video-data synchronization to calculate the camera visual hull by identifying all 3D vertices using the ICSAD electromagnetic sensors. We also concentrated on high velocity peaks as a means of identifying potential erroneous movements to be confirmed by studying the corresponding video frames. The outcome of the study clearly shows that the kinematic data are precisely synchronized with the video frames and that the velocity peaks correspond to large and sudden excursions of the instrument tip. We validated the camera visual hull by both video and geometrical kinematic analysis and we observed that graphs containing fewer sudden velocity peaks are less likely to have erroneous movements. This work presented further developments to the well-established ICSAD dexterity analysis system. Synchronized real-time motion and video acquisition provides a comprehensive assessment solution by combining quantitative motion analysis tools and qualitative targeted video scoring.