- 24 January 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (3) , 1377-1396
Expressions for the earth resistance of the human feet in safety studies of earthing systems
- 24 January 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (3) , 1377-1396
Expressions for the earth resistance of the human feet in safety studies of earthing systems
- 1 May 2010
- Published by Elsevier in Electric Power Systems Research
- Vol. 80 (5) , 556-561
Mesh voltages at earthing grids buried in multi-layer soil
- 1 May 2010
- Published by Elsevier in Electric Power Systems Research
- Vol. 80 (5) , 556-561
Mesh voltages at earthing grids buried in multi-layer soil
- 1 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 22 (4) , 2180-2184
Effects of the Local Soil Nonuniformity Upon Performances of Ground Grids
The effects are studied of the material for leveling spread over and of installation channels led through substation site upon the safety risk associated with grounding. The main ground grid performances in case of ground faults are analyzed for various ratios of overlaid material and surrounding soil resistivities and horizontal dimensions and thickness of the overlaid material. Also, the effects of the installation channels dug along various routes upon the potential distribution on the ground surface and step voltages are considered. It was shown that the mentioned local nonuniformities can substantially affect the safety performances of the ground grid and that they should be carefully taken into consideration. The local soil irregularities considered have been modeled by applying the method of finite elements.
- 1 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 22 (4) , 2180-2184
Effects of the Local Soil Nonuniformity Upon Performances of Ground Grids
The effects are studied of the material for leveling spread over and of installation channels led through substation site upon the safety risk associated with grounding. The main ground grid performances in case of ground faults are analyzed for various ratios of overlaid material and surrounding soil resistivities and horizontal dimensions and thickness of the overlaid material. Also, the effects of the installation channels dug along various routes upon the potential distribution on the ground surface and step voltages are considered. It was shown that the mentioned local nonuniformities can substantially affect the safety performances of the ground grid and that they should be carefully taken into consideration. The local soil irregularities considered have been modeled by applying the method of finite elements.
- 12 January 2005
- Published by Springer Nature in Electrical Engineering
- Vol. 88 (4) , 281-287
Resistance to earth of earthing grids buried in multi-layer soil
- 12 January 2005
- Published by Springer Nature in Electrical Engineering
- Vol. 88 (4) , 281-287
Resistance to earth of earthing grids buried in multi-layer soil
- 1 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Engineering Review
- Vol. 22 (11) , 61-62
Safety Conditions in Manholes in the Vicinity of Substations
In many cases, the manholes for maintaining various installations including power and telecommunication cables, water-, remote heating-, and gas-pipes are located in a close vicinity of power substations. The paper analyzes the risks of the occurrence of dangerous potential differences within the manhole and on the surrounding ground surface during ground faults in the substation. Possible protective measures are discussed.
- 1 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Engineering Review
- Vol. 22 (11) , 61-62
Safety Conditions in Manholes in the Vicinity of Substations
In many cases, the manholes for maintaining various installations including power and telecommunication cables, water-, remote heating-, and gas-pipes are located in a close vicinity of power substations. The paper analyzes the risks of the occurrence of dangerous potential differences within the manhole and on the surrounding ground surface during ground faults in the substation. Possible protective measures are discussed.