Mikko Peltokangas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mikko Peltokangas has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Antti Vehkaoja
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
14 shared publications - Jukka Lekkala
BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, FINLAND
7 shared publications - Niku Oksala
Finnish Cardiovascular Research Center – Tampere, Tampere University
7 shared publications Jarmo Verho
Faculty of Medicine and Health Technology, Tampere University, Tampere 33720, FINLAND
6 shared publications- Mika-Matti Laurila
Faculty of Information Technology and Communication Sciences Tampere University Tampere 33720 Finland
3 shared publications Niku Oksala
Division of Vascular Surgery, Department of Surgery, Tampere University Hospital, Tampere, Finland; Finnish Cardiovascular Research Center Tampere, Surgery, Faculty of Medicine and Life Sciences, University of Tampere, Tampere, Finland
3 shared publications
Latest Publications
- Open Access
- 1 February 2021
- Published by Elsevier in Atherosclerosis
- Vol. 319, 101-107
Impedance plethysmography-based method in the assessment of subclinical atherosclerosis
- 1 February 2021
- Published by Elsevier in Atherosclerosis
- Vol. 319, 101-107
Open AccessImpedance plethysmography-based method in the assessment of subclinical atherosclerosis
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11072-11080
Evaluation of Printed P(VDF-TrFE) Pressure Sensor Signal Quality in Arterial Pulse Wave Measurement
In this contribution, we evaluate the performance of an additively fabricated piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (P(VDF-TrFE)) based dynamic pressure sensor in non-invasive arterial pulse wave (PW) measurement. Additively fabricated piezoelectric sensors have high potential for the realization of affordable and unobtrusive PW measurement systems which could enable the long-term monitoring of patients with cardiovascular diseases (CVDs). However, the accuracy and reliability of such sensors have not been extensively studied before. We propose an additive fabrication process for a P(VDF-TrFE) PW-sensor, measure PW from the radial artery at the wrist from 22 healthy volunteer subjects, calculate clinically relevant parameters based on the PW waveform and compare their values to the values obtained from concurrent measurement with an electromechanical film (EMFi) based reference sensor, used earlier in several clinical studies. We show that the signals recorded with the two sensors, as well as the radial augmentation index (rAIx) and the stiffness index (SI) calculated from them, are in good agreement with each other. These results demonstrate that the additively fabricated P(VDF-TrFE) PW sensors can reach a suitable level of accuracy and reliability for clinical use.
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11072-11080
Evaluation of Printed P(VDF-TrFE) Pressure Sensor Signal Quality in Arterial Pulse Wave Measurement
In this contribution, we evaluate the performance of an additively fabricated piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (P(VDF-TrFE)) based dynamic pressure sensor in non-invasive arterial pulse wave (PW) measurement. Additively fabricated piezoelectric sensors have high potential for the realization of affordable and unobtrusive PW measurement systems which could enable the long-term monitoring of patients with cardiovascular diseases (CVDs). However, the accuracy and reliability of such sensors have not been extensively studied before. We propose an additive fabrication process for a P(VDF-TrFE) PW-sensor, measure PW from the radial artery at the wrist from 22 healthy volunteer subjects, calculate clinically relevant parameters based on the PW waveform and compare their values to the values obtained from concurrent measurement with an electromechanical film (EMFi) based reference sensor, used earlier in several clinical studies. We show that the signals recorded with the two sensors, as well as the radial augmentation index (rAIx) and the stiffness index (SI) calculated from them, are in good agreement with each other. These results demonstrate that the additively fabricated P(VDF-TrFE) PW sensors can reach a suitable level of accuracy and reliability for clinical use.
- Open Access
- 6 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of the Electron Devices Society
- Vol. 7 (1) , 566-574
A Fully Printed Ultra-Thin Charge Amplifier for On-Skin Biosignal Measurements
In this contribution, we propose a fully printed charge amplifier for on-skin biosignal measurements. The amplifier is fabricated on an ultra-thin parylene substrate and consists of organic transistors, integrated bias and feedback resistors, and a feedback capacitor. The fabrication process utilizes inkjet-printed Ag ink for source, drain, gate, and capacitor electrode metallization as well as for the interconnects between the amplifier elements. Dispensed polystyrene, 2,7-dihexyl-dithieno2,3-d;2’,3’-d’benzo1,2-b;4,5-b’dithiophene (PS:DTBDT-C6), is used as the transistor channel material, dispensed poly(3-hexylthiophene) (P3HT) as the high-resistivity material for the printed resistors, and parylene as the capacitor dielectric. A pass band optimized for pulse-wave measurement (60 mHz to 36 Hz) is achieved with a maximum charge amplification of 1.6 V/nC. To demonstrate the potential of the proposed printed amplifier, a radial arterial pulsewave signal recorded with a printed piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (PVDF-TrFE) sensor was fed to it and the output was analyzed to quantify the similarity of the pulse-wave features calculated from the original signal and the amplifier output. The amplified signal contains all the essential features of a pulse wave, such as both systolic waves, the dicrotic notch, and diastolic wave, which enable the accurate derivation of the clinically relevant indices utilized in the evaluation of vascular health.
- 6 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of the Electron Devices Society
- Vol. 7 (1) , 566-574
Open AccessA Fully Printed Ultra-Thin Charge Amplifier for On-Skin Biosignal Measurements
In this contribution, we propose a fully printed charge amplifier for on-skin biosignal measurements. The amplifier is fabricated on an ultra-thin parylene substrate and consists of organic transistors, integrated bias and feedback resistors, and a feedback capacitor. The fabrication process utilizes inkjet-printed Ag ink for source, drain, gate, and capacitor electrode metallization as well as for the interconnects between the amplifier elements. Dispensed polystyrene, 2,7-dihexyl-dithieno2,3-d;2’,3’-d’benzo1,2-b;4,5-b’dithiophene (PS:DTBDT-C6), is used as the transistor channel material, dispensed poly(3-hexylthiophene) (P3HT) as the high-resistivity material for the printed resistors, and parylene as the capacitor dielectric. A pass band optimized for pulse-wave measurement (60 mHz to 36 Hz) is achieved with a maximum charge amplification of 1.6 V/nC. To demonstrate the potential of the proposed printed amplifier, a radial arterial pulsewave signal recorded with a printed piezoelectric poly(vinylidenefluoride-cotrifluoroethylene) (PVDF-TrFE) sensor was fed to it and the output was analyzed to quantify the similarity of the pulse-wave features calculated from the original signal and the amplifier output. The amplified signal contains all the essential features of a pulse wave, such as both systolic waves, the dicrotic notch, and diastolic wave, which enable the accurate derivation of the clinically relevant indices utilized in the evaluation of vascular health.
- 11 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (9) , 2596-2603
Lower Limb Pulse Rise Time as a Marker of Peripheral Arterial Disease
Objective: The aim of the study was to show if pulse rise times (PRTs) extracted from photoplethysmographic (PPG) pulse waves (PWs) have an association with peripheral arterial disease (PAD) or its endovascular treatment, percutanoeus transluminal angioplasty (PTA) of the superficial femoral artery. Methods: Lower and upper limb PPG PWs were recorded and analyzed from 24 patients who suffered from PAD. The measurements were conducted before and after the treatment, and one month later by using transmission-mode PPG-probes placed in the index finger and second toe. Ankle-to-brachial pressure index and toe pressures were used as references in clinical patient measurements. PRTs, i.e., the time from the foot point to the peak point of the PW, were extracted from the PWs and compared bilaterally. The results from the PAD patients were also compared with 31 same-aged and 34 younger control subjects. Results: Statistically significant differences were found between the pretreatment PRTs of the treated limb of the PAD patients and the same-aged control subjects ( $p< 10^{-9}$ , Mann–Whitney U-test). The changes in the PRT of the treated lower limb were observed immediately after the PTA ( $p< 0.001$ , Student's t -test), and after one month ( $p< 0.0005$ ), whereas the PRTs of the non-treated lower limb and upper limb did not indicate changes between different examinations. Conclusion: Results show that a PRT greater than 240 ms indicates PAD-lesions in the lower limb. Significance: This proof-of-concept study suggests that the PRT could be an effective and easy-to-use indicator for PAD and monitoring the effectiveness of its treatment.
- 11 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (9) , 2596-2603
Lower Limb Pulse Rise Time as a Marker of Peripheral Arterial Disease
Objective: The aim of the study was to show if pulse rise times (PRTs) extracted from photoplethysmographic (PPG) pulse waves (PWs) have an association with peripheral arterial disease (PAD) or its endovascular treatment, percutanoeus transluminal angioplasty (PTA) of the superficial femoral artery. Methods: Lower and upper limb PPG PWs were recorded and analyzed from 24 patients who suffered from PAD. The measurements were conducted before and after the treatment, and one month later by using transmission-mode PPG-probes placed in the index finger and second toe. Ankle-to-brachial pressure index and toe pressures were used as references in clinical patient measurements. PRTs, i.e., the time from the foot point to the peak point of the PW, were extracted from the PWs and compared bilaterally. The results from the PAD patients were also compared with 31 same-aged and 34 younger control subjects. Results: Statistically significant differences were found between the pretreatment PRTs of the treated limb of the PAD patients and the same-aged control subjects ( $p< 10^{-9}$ , Mann–Whitney U-test). The changes in the PRT of the treated lower limb were observed immediately after the PTA ( $p< 0.001$ , Student's t -test), and after one month ( $p< 0.0005$ ), whereas the PRTs of the non-treated lower limb and upper limb did not indicate changes between different examinations. Conclusion: Results show that a PRT greater than 240 ms indicates PAD-lesions in the lower limb. Significance: This proof-of-concept study suggests that the PRT could be an effective and easy-to-use indicator for PAD and monitoring the effectiveness of its treatment.
- 28 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (3) , 1058-1065
Effects of Percutaneous Transluminal Angioplasty of Superficial Femoral Artery on Photoplethysmographic Pulse Transit Times
We analyze the changes in upper and lower limb pulse transit times (PTT) caused by peripheral artery disease (PAD) and its treatment with percutaneous transluminal angioplasty (PTA) of the superficial femoral artery. PTTs were extracted from the photoplethysmograms (PPG) recorded from an index finger and 2nd toes. PTTs were defined between the R-peaks of the ECG and different reference points of the (PPG): foot and peak points, maxima of 1st and 2nd derivative, and by means of intersecting tangents method. Also the PTTs between the toe and finger pulses were analyzed. Our sample consists of 24 subjects examined before and after the PTA and in 1-month follow-up visit. Also 28 older than 65 years controls having normal ankle-to-brachial pressure index (ABI) and no history in cardiovascular diseases as well as 21 younger subjects were examined. The differences between the groups and pre- and post-treatment phases were analyzed by means of non-parametric statistical tests. The changes in the PTTs of upper limb and non-treated lower limb were negligible. The agreement with the reference values, ABI and toe pressures, was studied by kappa-analysis, resulting in kappa-values of 0.33$\times$0.91. Differences in PTTs were found between pre-treatment state of the treated limb, post-treatment state and the follow-up visit, as well as between the pre-treatment state and controls. If patients' age and systolic blood pressure were taken into consideration, the method of lower limb PTT calculation from the peak point turns out feasible in finding the markers of PAD and monitoring post- treatment vascular remodellation.
- 28 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (3) , 1058-1065
Effects of Percutaneous Transluminal Angioplasty of Superficial Femoral Artery on Photoplethysmographic Pulse Transit Times
We analyze the changes in upper and lower limb pulse transit times (PTT) caused by peripheral artery disease (PAD) and its treatment with percutaneous transluminal angioplasty (PTA) of the superficial femoral artery. PTTs were extracted from the photoplethysmograms (PPG) recorded from an index finger and 2nd toes. PTTs were defined between the R-peaks of the ECG and different reference points of the (PPG): foot and peak points, maxima of 1st and 2nd derivative, and by means of intersecting tangents method. Also the PTTs between the toe and finger pulses were analyzed. Our sample consists of 24 subjects examined before and after the PTA and in 1-month follow-up visit. Also 28 older than 65 years controls having normal ankle-to-brachial pressure index (ABI) and no history in cardiovascular diseases as well as 21 younger subjects were examined. The differences between the groups and pre- and post-treatment phases were analyzed by means of non-parametric statistical tests. The changes in the PTTs of upper limb and non-treated lower limb were negligible. The agreement with the reference values, ABI and toe pressures, was studied by kappa-analysis, resulting in kappa-values of 0.33$\times$0.91. Differences in PTTs were found between pre-treatment state of the treated limb, post-treatment state and the follow-up visit, as well as between the pre-treatment state and controls. If patients' age and systolic blood pressure were taken into consideration, the method of lower limb PTT calculation from the peak point turns out feasible in finding the markers of PAD and monitoring post- treatment vascular remodellation.
- 30 May 2018
- Published by Springer Nature in IFMBE Proceedings
- p. 183-187
TangoTM Wellness Motivator for Supporting Permanent Lifestyle Change
- 30 May 2018
- Published by Springer Nature in IFMBE Proceedings
- p. 183-187
TangoTM Wellness Motivator for Supporting Permanent Lifestyle Change
- Open Access
Acquiring Respiration Rate from Photoplethysmographic Signal by Recursive Bayesian Tracking of Intrinsic Modes in Time-Frequency Spectra
Respiration rate (RR) provides useful information for assessing the status of a patient. We propose RR estimation based on photoplethysmography (PPG) because the blood perfusion dynamics are known to carry information on breathing, as respiration-induced modulations in the PPG signal. We studied the use of amplitude variability of transmittance mode finger PPG signal in RR estimation by comparing four time-frequency (TF) representation methods of the signal cascaded with a particle filter. The TF methods compared were short-time Fourier transform (STFT) and three types of synchrosqueezing methods. The public VORTAL database was used in this study. The results indicate that the advanced frequency reallocation methods based on synchrosqueezing approach may present improvement over linear methods, such as STFT. The best results were achieved using wavelet synchrosqueezing transform, having a mean absolute error and median error of 2.33 and 1.15 breaths per minute, respectively. Synchrosqueezing methods were generally more accurate than STFT on most of the subjects when particle filtering was applied. While TF analysis combined with particle filtering is a promising alternative for real-time estimation of RR, artefacts and non-respiration-related frequency components remain problematic and impose requirements for further studies in the areas of signal processing algorithms an PPG instrumentation.
Open AccessAcquiring Respiration Rate from Photoplethysmographic Signal by Recursive Bayesian Tracking of Intrinsic Modes in Time-Frequency Spectra
Respiration rate (RR) provides useful information for assessing the status of a patient. We propose RR estimation based on photoplethysmography (PPG) because the blood perfusion dynamics are known to carry information on breathing, as respiration-induced modulations in the PPG signal. We studied the use of amplitude variability of transmittance mode finger PPG signal in RR estimation by comparing four time-frequency (TF) representation methods of the signal cascaded with a particle filter. The TF methods compared were short-time Fourier transform (STFT) and three types of synchrosqueezing methods. The public VORTAL database was used in this study. The results indicate that the advanced frequency reallocation methods based on synchrosqueezing approach may present improvement over linear methods, such as STFT. The best results were achieved using wavelet synchrosqueezing transform, having a mean absolute error and median error of 2.33 and 1.15 breaths per minute, respectively. Synchrosqueezing methods were generally more accurate than STFT on most of the subjects when particle filtering was applied. While TF analysis combined with particle filtering is a promising alternative for real-time estimation of RR, artefacts and non-respiration-related frequency components remain problematic and impose requirements for further studies in the areas of signal processing algorithms an PPG instrumentation.
- Open Access
- 1 May 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 96, 274-282
The effect of percutaneous transluminal angioplasty of superficial femoral artery on pulse wave features
- 1 May 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 96, 274-282
Open AccessThe effect of percutaneous transluminal angioplasty of superficial femoral artery on pulse wave features
- 1 February 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (2) , 025003
Areas under peripheral pulse waves: a potential marker of atherosclerotic changes
Objective : In this study, we propose a method for finding atherosclerotic changes based on the ratios of areas under peripheral arterial pulse wave (PW) contours and analyze its performance. Approach : The PW signals were recorded with force sensors and photoplethysmographic sensors from ankle, wrist, cubital fossa, index finger and second toe from 30 atherosclerotic patients and 52 control subjects. In addition, the day-to-day repeatability of the method was studied with 10 test subjects examined on three different days. The ratios of areas under the PWs were computed and the results were evaluated by means of receiver operating characteristic (ROC) analysis, intra-class correlation (ICC) coefficient and multiple linear regression analysis. Main results : Areas under ROC curves of 0.802–0.906 were found for different area ratios having statistically significant differences between the atheroslerotic group and control groups. ICCs over 0.80 were found widely for the beat-by-beat analyzed data and over 0.95 for the data based on the averages over different numbers of PWs. Multiple linear regression analysis showed linear dependence between the area ratios and age and the diagnosis of atherosclerosis. Significance : Our findings may facilitate development of novel diagnostic approaches and preventive strategies against cardiovascular disorders. However, further studies are needed to confirm the results. The presented study demonstrates the potential of arterial PW analysis in finding vascular abnormalities.
- 1 February 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (2) , 025003
Areas under peripheral pulse waves: a potential marker of atherosclerotic changes
Objective : In this study, we propose a method for finding atherosclerotic changes based on the ratios of areas under peripheral arterial pulse wave (PW) contours and analyze its performance. Approach : The PW signals were recorded with force sensors and photoplethysmographic sensors from ankle, wrist, cubital fossa, index finger and second toe from 30 atherosclerotic patients and 52 control subjects. In addition, the day-to-day repeatability of the method was studied with 10 test subjects examined on three different days. The ratios of areas under the PWs were computed and the results were evaluated by means of receiver operating characteristic (ROC) analysis, intra-class correlation (ICC) coefficient and multiple linear regression analysis. Main results : Areas under ROC curves of 0.802–0.906 were found for different area ratios having statistically significant differences between the atheroslerotic group and control groups. ICCs over 0.80 were found widely for the beat-by-beat analyzed data and over 0.95 for the data based on the averages over different numbers of PWs. Multiple linear regression analysis showed linear dependence between the area ratios and age and the diagnosis of atherosclerosis. Significance : Our findings may facilitate development of novel diagnostic approaches and preventive strategies against cardiovascular disorders. However, further studies are needed to confirm the results. The presented study demonstrates the potential of arterial PW analysis in finding vascular abnormalities.
- 13 June 2017
- Published by Springer Nature
- p. 342-345
Short-term stability of combined finger and toe photoplethysmogram analysis
- 13 June 2017
- Published by Springer Nature
- p. 342-345
Short-term stability of combined finger and toe photoplethysmogram analysis