Nakin Suksawang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nakin Suksawang has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Arvind Agarwal
Florida International University
8 shared publications Kaushal K. Jha
Florida International University
5 shared publicationsSalam Wtaife
University of Misan
5 shared publicationsAhmed Alsabbagh
University of Babylon
4 shared publications- Amir Mirmiran
Provost and Lindsey Chair Professor, Univ. of Texas at Tyler, 3900 University Blvd., Tyler, TX 75799
4 shared publications Alaa Shaban
3 shared publications
Latest Publications
- 5 November 2020
- Published by Springer Nature
- p. 12-23
Using Fiber Reinforced Concrete to Control Early-Age Shrinkage in Replacement Concrete Pavement
- 5 November 2020
- Published by Springer Nature
- p. 12-23
Using Fiber Reinforced Concrete to Control Early-Age Shrinkage in Replacement Concrete Pavement
- 5 November 2020
- Published by Springer Nature
- p. 111-122
Evaluation the Yield and Ultimate Strain of FRC in Compression
- 5 November 2020
- Published by Springer Nature
- p. 111-122
Evaluation the Yield and Ultimate Strain of FRC in Compression
- 1 April 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 240
Using post-cracking strength to determine flexural capacity of ultra-thin whitetopping (UTW) pavements
- 1 April 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 240
Using post-cracking strength to determine flexural capacity of ultra-thin whitetopping (UTW) pavements
- 1 December 2019
- Published by Elsevier in Engineering Structures
- Vol. 201
Vibration control for torsionally irregular buildings by integrated control system
- 1 December 2019
- Published by Elsevier in Engineering Structures
- Vol. 201
Vibration control for torsionally irregular buildings by integrated control system
- 1 October 2019
- Published by Elsevier in Computers & Structures
- Vol. 223, 106097
Performance evaluation of a reinforced concrete building strengthened respectively by the infill wall, active and passive tuned mass damper under seismic load
- 1 October 2019
- Published by Elsevier in Computers & Structures
- Vol. 223, 106097
Performance evaluation of a reinforced concrete building strengthened respectively by the infill wall, active and passive tuned mass damper under seismic load
- Open Access
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 584 (1)
Enhancement of Rigid Pavement Capacity Using Synthetic Discrete Fibers
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 584 (1)
Open AccessEnhancement of Rigid Pavement Capacity Using Synthetic Discrete Fibers
- Open Access
- 12 December 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 454
Effect of Hybrid Discrete Fibers on Mechanical Properties of FRC
- 12 December 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 454
Open AccessEffect of Hybrid Discrete Fibers on Mechanical Properties of FRC
- Open Access
- 14 May 2018
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2672 (41) , 34-43
Developing Guidelines for Epoxy Grout Pourback Systems for Controlling Thermal/Shrinkage Cracking at Post-Tensioning Anchorages: Full-Scale Testing and Numerical Analysis
Epoxy grout pourbacks at end anchorages of post-tensioning tendons provide an essential level of corrosion protection. The tendon may fail because of strand corrosion, within a few years of installation, if it is not properly protected with epoxy grout pourbacks. Recently, the Florida Department of Transportation (FDOT) found cracking on larger epoxy grout pourbacks, possibly as a result of the exothermic nature of the epoxy grout curing, causing thermal stresses that increase the potential for pourbacks cracking. Coordinated laboratory and numerical investigations were undertaken to develop best practice guidance for eliminating cracking in epoxy grout pourbacks. Potential factors were determined to be the pourback size, shapes, and temperature of the concrete substrate. An epoxy grout pourback material was used to construct full-scale pourback systems consisting of rectangular (R-type) and irregular (S-type) pourbacks with volume to surface, V/S ratios of 80, 98, and 113 mm. The full-scale specimens were instrumented with multiple thermocouples and a vibrating wire strain gauge, to capture the temperature profile and localized strain respectively. An ANSYS finite element model was developed to perform a parametric study to better understand the cracking mechanism and the influence of the V/S ratio. The model was calibrated and validated using the data obtained from the full-scale test. Based on the research findings, it is recommended that the maximum value of the V/S ratio of the epoxy grout pourbacks be limited to 91 for S-type and 107 mm for R-type shapes.
- 14 May 2018
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2672 (41) , 34-43
Open AccessDeveloping Guidelines for Epoxy Grout Pourback Systems for Controlling Thermal/Shrinkage Cracking at Post-Tensioning Anchorages: Full-Scale Testing and Numerical Analysis
Epoxy grout pourbacks at end anchorages of post-tensioning tendons provide an essential level of corrosion protection. The tendon may fail because of strand corrosion, within a few years of installation, if it is not properly protected with epoxy grout pourbacks. Recently, the Florida Department of Transportation (FDOT) found cracking on larger epoxy grout pourbacks, possibly as a result of the exothermic nature of the epoxy grout curing, causing thermal stresses that increase the potential for pourbacks cracking. Coordinated laboratory and numerical investigations were undertaken to develop best practice guidance for eliminating cracking in epoxy grout pourbacks. Potential factors were determined to be the pourback size, shapes, and temperature of the concrete substrate. An epoxy grout pourback material was used to construct full-scale pourback systems consisting of rectangular (R-type) and irregular (S-type) pourbacks with volume to surface, V/S ratios of 80, 98, and 113 mm. The full-scale specimens were instrumented with multiple thermocouples and a vibrating wire strain gauge, to capture the temperature profile and localized strain respectively. An ANSYS finite element model was developed to perform a parametric study to better understand the cracking mechanism and the influence of the V/S ratio. The model was calibrated and validated using the data obtained from the full-scale test. Based on the research findings, it is recommended that the maximum value of the V/S ratio of the epoxy grout pourbacks be limited to 91 for S-type and 107 mm for R-type shapes.
- 1 March 2018
- Published by American Concrete Institute in ACI Materials Journal
- Vol. 115 (2) , 239-249
Evaluation of Elastic Modulus of Fiber-Reinforced Concrete
- 1 March 2018
- Published by American Concrete Institute in ACI Materials Journal
- Vol. 115 (2) , 239-249
Evaluation of Elastic Modulus of Fiber-Reinforced Concrete
- 1 September 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 22 (3)
Full-Scale Testing of a Precast Concrete Supertile Roofing System for Hurricane Damage Mitigation
High wind-induced suctions cause significant damage in traditional roofing systems, leading to subsequent rain intrusion and loss of interior contents. Damages include, among others, failure of tiles or shingles and in many roofing systems are related to workmanship-related issues, such as inadequate spacing of nails or poor application of foam adhesive. This paper proposes a new composite roofing system, which consists of large precast concrete structural panels designed to replicate the architectural shape of high-profile roof tiles. The system allows the components and cladding (C&C), usually placed onto the structure, to be incorporated into the main wind force resisting system (MWFRS). The roofing panels, therefore, serve both as a structural system and as an architecturally pleasing building envelope. As a first step toward the full development of the proposed system, full-scale tests were performed to evaluate its system-level structural performance, including its connections. The results a...
- 1 September 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 22 (3)
Full-Scale Testing of a Precast Concrete Supertile Roofing System for Hurricane Damage Mitigation
High wind-induced suctions cause significant damage in traditional roofing systems, leading to subsequent rain intrusion and loss of interior contents. Damages include, among others, failure of tiles or shingles and in many roofing systems are related to workmanship-related issues, such as inadequate spacing of nails or poor application of foam adhesive. This paper proposes a new composite roofing system, which consists of large precast concrete structural panels designed to replicate the architectural shape of high-profile roof tiles. The system allows the components and cladding (C&C), usually placed onto the structure, to be incorporated into the main wind force resisting system (MWFRS). The roofing panels, therefore, serve both as a structural system and as an architecturally pleasing building envelope. As a first step toward the full development of the proposed system, full-scale tests were performed to evaluate its system-level structural performance, including its connections. The results a...