Brendan D. MacDonald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brendan D. MacDonald has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Almostasim Mahmud
Faculty of Engineering and Applied Science, University of Ontario Institute of Technology, 2000 Simcoe Street North, Oshawa, ON L1H 7K4, Canada
5 shared publications - Max M. Gong
Department of Biomedical Engineering
5 shared publications - David Sinton
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, M5S 3G8, Canada
3 shared publications Trung Vu Nguyen
Department of Clinical Microbiology and Parasitology, Hanoi Medical University, 1 Ton That Tung Street, Dong Dag, Hanoi, Vietnam
3 shared publicationsAndrew M. Rowe
Institute for Integrated Energy Systems, Department of Mechanical Engineering, University of Victoria, P.O. Box 3055 STN CSC, Victoria, B.C. V8W 3P6, Canada
2 shared publications- Charles Albert Ward
Thermodynamics and Kinetics Laboratory, Department of Mechanical and Industrial Engineering, University of Toronto, 5 King’s College Road, Toronto M5S 3G8, Canada
2 shared publications
Latest Publications
- 19 January 2022
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 175
Experimental investigation of forced convection on evaporation of continuously-fed sessile droplets
- 19 January 2022
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 175
Experimental investigation of forced convection on evaporation of continuously-fed sessile droplets
- Open Access
- 1 January 2020
- Published by AIP Publishing in Biomicrofluidics
- Vol. 14 (1) , 014107
Counting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes
In this paper, we report the development of semiquantitative counting-based lateral flow assay (LFA)-type microfluidic paper-based analytical devices ( PADs) to analyze samples at submicroliter volumes. The ability to use submicroliter sample volumes is a significant advantage for PADs since it enables enhanced multiplexing, reduces cost, and increases user-friendliness since small sample volumes can be collected using methods that do not require trained personnel, such as finger pricking and microneedles. The challenge of accomplishing a semiquantitative test readout using submicroliter sample volumes was overcome with a counting-based approach. In order to use submicroliter sample volumes, we developed a flow strategy with a running liquid to facilitate flow through the assay. The efficacy of the devices was confirmed with glucose and total human immunoglobulin E (IgE) tests using 0.5 l and 1 l of sample solutions, respectively. Semiquantitative results were generated to predict glucose concentrations in the range of 0–12 mmol/l and IgE concentrations in the range of 0–400 ng/ml. The counting-based approach correlates the number of dots that exhibited a color change to the concentration of the analyte, which provides a more user-friendly method as compared with interpreting the intensity of a color change. The devices reported herein are the first counting-based LFA-type PADs capable of semiquantitative testing using submicroliter sample volumes.- 1 January 2020
- Published by AIP Publishing in Biomicrofluidics
- Vol. 14 (1) , 014107
Open AccessCounting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes
In this paper, we report the development of semiquantitative counting-based lateral flow assay (LFA)-type microfluidic paper-based analytical devices ( PADs) to analyze samples at submicroliter volumes. The ability to use submicroliter sample volumes is a significant advantage for PADs since it enables enhanced multiplexing, reduces cost, and increases user-friendliness since small sample volumes can be collected using methods that do not require trained personnel, such as finger pricking and microneedles. The challenge of accomplishing a semiquantitative test readout using submicroliter sample volumes was overcome with a counting-based approach. In order to use submicroliter sample volumes, we developed a flow strategy with a running liquid to facilitate flow through the assay. The efficacy of the devices was confirmed with glucose and total human immunoglobulin E (IgE) tests using 0.5 l and 1 l of sample solutions, respectively. Semiquantitative results were generated to predict glucose concentrations in the range of 0–12 mmol/l and IgE concentrations in the range of 0–400 ng/ml. The counting-based approach correlates the number of dots that exhibited a color change to the concentration of the analyte, which provides a more user-friendly method as compared with interpreting the intensity of a color change. The devices reported herein are the first counting-based LFA-type PADs capable of semiquantitative testing using submicroliter sample volumes. - Open Access
Efficiency Reduction in Stirling Engines Resulting from Sinusoidal Motion
Stirling engines have a high potential to produce renewable energy due to their ability to use a wide range of sustainable heat sources, such as concentrated solar thermal power and biomass, and also due to their high theoretical efficiencies. They have not yet achieved widespread use and commercial Stirling engines have had reduced efficiencies compared to their ideal values. In this work we show that a substantial amount of the reduction in efficiency is due to the operation of Stirling engines using sinusoidal motion and quantify this reduction. A discrete model was developed to perform an isothermal analysis of a 100cc alpha-type Stirling engine with a 90 phase angle offset, to demonstrate the impact of sinusoidal motion on the net work and thermal efficiency in comparison to the ideal cycle. For the specific engine analyzed, the maximum thermal efficiency of the sinusoidal cycle was found to have a limit of 34.4%, which is a reduction of 27.1% from Carnot efficiency. The net work of the sinusoidal cycle was found to be 65.9% of the net work from the ideal cycle. The model was adapted to analyze beta and gamma-type Stirling configurations, and the analysis revealed similar reductions due to sinusoidal motion.Open AccessEfficiency Reduction in Stirling Engines Resulting from Sinusoidal Motion
Stirling engines have a high potential to produce renewable energy due to their ability to use a wide range of sustainable heat sources, such as concentrated solar thermal power and biomass, and also due to their high theoretical efficiencies. They have not yet achieved widespread use and commercial Stirling engines have had reduced efficiencies compared to their ideal values. In this work we show that a substantial amount of the reduction in efficiency is due to the operation of Stirling engines using sinusoidal motion and quantify this reduction. A discrete model was developed to perform an isothermal analysis of a 100cc alpha-type Stirling engine with a 90 phase angle offset, to demonstrate the impact of sinusoidal motion on the net work and thermal efficiency in comparison to the ideal cycle. For the specific engine analyzed, the maximum thermal efficiency of the sinusoidal cycle was found to have a limit of 34.4%, which is a reduction of 27.1% from Carnot efficiency. The net work of the sinusoidal cycle was found to be 65.9% of the net work from the ideal cycle. The model was adapted to analyze beta and gamma-type Stirling configurations, and the analysis revealed similar reductions due to sinusoidal motion. - Open Access
- 2 August 2018
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 852, 1-4
Flow of liquids through paper
The flow of liquids through paper is challenging to model due to the complexity and disordered layout of the fibre matrix. The expanding use and capability of microfluidic paper-based analytical devices ( $\unicode[STIX]{x1D707}$ PADs) and their requirement for precision has increased the need to accurately predict the flow of liquids through paper. Many studies have developed models and revealed some of the physical mechanisms responsible for the flow behaviour, but we still lack a complete understanding, particularly in relation to how the fluid fills the various voids with a wide range of shapes and sizes in the fibre matrix of paper. In the featured article, Changet al. (J. Fluid Mech., vol. 845, 2018, 36–50) used a combined experimental and theoretical approach to uncover the importance of the liquid filling the intra-fibre pores, showed that this results in deviation from the flow behaviour predicted by the Lucas–Washburn equation and developed a model which accounts for this effect.- 2 August 2018
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 852, 1-4
Open AccessFlow of liquids through paper
The flow of liquids through paper is challenging to model due to the complexity and disordered layout of the fibre matrix. The expanding use and capability of microfluidic paper-based analytical devices ( $\unicode[STIX]{x1D707}$ PADs) and their requirement for precision has increased the need to accurately predict the flow of liquids through paper. Many studies have developed models and revealed some of the physical mechanisms responsible for the flow behaviour, but we still lack a complete understanding, particularly in relation to how the fluid fills the various voids with a wide range of shapes and sizes in the fibre matrix of paper. In the featured article, Changet al. (J. Fluid Mech., vol. 845, 2018, 36–50) used a combined experimental and theoretical approach to uncover the importance of the liquid filling the intra-fibre pores, showed that this results in deviation from the flow behaviour predicted by the Lucas–Washburn equation and developed a model which accounts for this effect. - Open Access
- 7 May 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (5) , 220
Features in Microfluidic Paper-Based Devices Made by Laser Cutting: How Small Can They Be?
In this paper, we determine the smallest feature size that enables fluid flow in microfluidic paper-based analytical devices (µPADs) fabricated by laser cutting. The smallest feature sizes fabricated from five commercially available paper types: Whatman filter paper grade 50 (FP-50), Whatman 3MM Chr chromatography paper (3MM Chr), Whatman 1 Chr chromatography paper (1 Chr), Whatman regenerated cellulose membrane 55 (RC-55) and Amershan Protran 0.45 nitrocellulose membrane (NC), were 139 ± 8 µm, 130 ± 11 µm, 103 ± 12 µm, 45 ± 6 µm, and 24 ± 3 µm, respectively, as determined experimentally by successful fluid flow. We found that the fiber width of the paper correlates with the smallest feature size that has the capacity for fluid flow. We also investigated the flow speed of Allura red dye solution through small-scale channels fabricated from different paper types. We found that the flow speed is significantly slower through microscale features and confirmed the similar trends that were reported previously for millimeter-scale channels, namely that wider channels enable quicker flow speed.
- 7 May 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (5) , 220
Open AccessFeatures in Microfluidic Paper-Based Devices Made by Laser Cutting: How Small Can They Be?
In this paper, we determine the smallest feature size that enables fluid flow in microfluidic paper-based analytical devices (µPADs) fabricated by laser cutting. The smallest feature sizes fabricated from five commercially available paper types: Whatman filter paper grade 50 (FP-50), Whatman 3MM Chr chromatography paper (3MM Chr), Whatman 1 Chr chromatography paper (1 Chr), Whatman regenerated cellulose membrane 55 (RC-55) and Amershan Protran 0.45 nitrocellulose membrane (NC), were 139 ± 8 µm, 130 ± 11 µm, 103 ± 12 µm, 45 ± 6 µm, and 24 ± 3 µm, respectively, as determined experimentally by successful fluid flow. We found that the fiber width of the paper correlates with the smallest feature size that has the capacity for fluid flow. We also investigated the flow speed of Allura red dye solution through small-scale channels fabricated from different paper types. We found that the flow speed is significantly slower through microscale features and confirmed the similar trends that were reported previously for millimeter-scale channels, namely that wider channels enable quicker flow speed.
- Open Access
Comparison of the Net Work Output between Stirling and Ericsson Cycles
In this paper, we compare Stirling and Ericsson cycles to determine which engine produces greater net work output for various situations. Both cycles are for external heat engines that utilize regenerators, where the difference is the nature of the regeneration process, which is constant volume for Stirling and constant pressure for Ericsson. This difference alters the performance characteristics of the two engines drastically, and our comparison reveals which one produces greater net work output based on the thermodynamic parameters. The net work output equations are derived and analysed for three different scenarios: (i) equal mass and temperature limits; (ii) equal mass and pressure or volume; and (iii) equal temperature and pressure or volume limits. The comparison is performed by calculating when both cycles produce equal net work output and then analysing which one produces greater net work output based on how the parameters are varied. In general, the results demonstrate that Stirling engines produce more net work output at higher pressures and lower volumes, and Ericsson engines produce more net work output at lower pressures and higher volumes. For certain scenarios, threshold values are calculated to illustrate precisely when one cycle produces more net work output than the other. This paper can be used to inform the design of the engines and to determine when a Stirling or Ericsson engine should be selected for a particular application.
Open AccessComparison of the Net Work Output between Stirling and Ericsson Cycles
In this paper, we compare Stirling and Ericsson cycles to determine which engine produces greater net work output for various situations. Both cycles are for external heat engines that utilize regenerators, where the difference is the nature of the regeneration process, which is constant volume for Stirling and constant pressure for Ericsson. This difference alters the performance characteristics of the two engines drastically, and our comparison reveals which one produces greater net work output based on the thermodynamic parameters. The net work output equations are derived and analysed for three different scenarios: (i) equal mass and temperature limits; (ii) equal mass and pressure or volume; and (iii) equal temperature and pressure or volume limits. The comparison is performed by calculating when both cycles produce equal net work output and then analysing which one produces greater net work output based on how the parameters are varied. In general, the results demonstrate that Stirling engines produce more net work output at higher pressures and lower volumes, and Ericsson engines produce more net work output at lower pressures and higher volumes. For certain scenarios, threshold values are calculated to illustrate precisely when one cycle produces more net work output than the other. This paper can be used to inform the design of the engines and to determine when a Stirling or Ericsson engine should be selected for a particular application.
- 1 October 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 125, 104-110
Analysis and feasibility of an evaporative cooling system with diffusion-based sessile droplet evaporation for cooling microprocessors
- 1 October 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 125, 104-110
Analysis and feasibility of an evaporative cooling system with diffusion-based sessile droplet evaporation for cooling microprocessors
- Open Access
- 1 March 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (3) , 71
Paper-Based Microfluidic Device with a Gold Nanosensor to Detect Arsenic Contamination of Groundwater in Bangladesh
In this paper, we present a microfluidic paper-based analytical device (μPAD) with a gold nanosensor functionalized with α-lipoic acid and thioguanine (Au–TA–TG) to detect whether the arsenic level of groundwater from hand tubewells in Bangladesh is above or below the World Health Organization (WHO) guideline level of 10 μg/L. We analyzed the naturally occurring metals present in Bangladesh groundwater and assessed the interference with the gold nanosensor. A method was developed to prevent interference from alkaline metals found in Bangladesh groundwater (Ca, Mg, K and Na) by increasing the pH level on the μPADs to 12.1. Most of the heavy metals present in the groundwater (Ni, Mn, Cd, Pb, and Fe II) did not interfere with the μPAD arsenic tests; however, Fe III was found to interfere, which was also prevented by increasing the pH level on the μPADs to 12.1. The μPAD arsenic tests were tested with 24 groundwater samples collected from hand tubewells in three different districts in Bangladesh: Shirajganj, Manikganj, and Munshiganj, and the predictions for whether the arsenic levels were above or below the WHO guideline level agreed with the results obtained from laboratory testing. The μPAD arsenic test is the first paper-based test validated using Bangladesh groundwater samples and capable of detecting whether the arsenic level in groundwater is above or below the WHO guideline level of 10 μg/L, which is a step towards enabling the villagers who collect and consume the groundwater to test their own sources and make decisions about where to obtain the safest water.
- 1 March 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (3) , 71
Open AccessPaper-Based Microfluidic Device with a Gold Nanosensor to Detect Arsenic Contamination of Groundwater in Bangladesh
In this paper, we present a microfluidic paper-based analytical device (μPAD) with a gold nanosensor functionalized with α-lipoic acid and thioguanine (Au–TA–TG) to detect whether the arsenic level of groundwater from hand tubewells in Bangladesh is above or below the World Health Organization (WHO) guideline level of 10 μg/L. We analyzed the naturally occurring metals present in Bangladesh groundwater and assessed the interference with the gold nanosensor. A method was developed to prevent interference from alkaline metals found in Bangladesh groundwater (Ca, Mg, K and Na) by increasing the pH level on the μPADs to 12.1. Most of the heavy metals present in the groundwater (Ni, Mn, Cd, Pb, and Fe II) did not interfere with the μPAD arsenic tests; however, Fe III was found to interfere, which was also prevented by increasing the pH level on the μPADs to 12.1. The μPAD arsenic tests were tested with 24 groundwater samples collected from hand tubewells in three different districts in Bangladesh: Shirajganj, Manikganj, and Munshiganj, and the predictions for whether the arsenic levels were above or below the WHO guideline level agreed with the results obtained from laboratory testing. The μPAD arsenic test is the first paper-based test validated using Bangladesh groundwater samples and capable of detecting whether the arsenic level in groundwater is above or below the WHO guideline level of 10 μg/L, which is a step towards enabling the villagers who collect and consume the groundwater to test their own sources and make decisions about where to obtain the safest water.
- 20 January 2017
- Published by American Physical Society (APS) in Physical Review E
- Vol. 95 (1) , 012609
Experimental investigation of interfacial energy transport in an evaporating sessile droplet for evaporative cooling applications
In this paper we experimentally examine evaporation flux distributions and modes of interfacial energy transport for continuously fed evaporating spherical sessile water droplets in a regime that is relevant for applications, particularly for evaporative cooling systems. The contribution of the thermal conduction through the vapor phase was found to be insignificant compared to the thermal conduction through the liquid phase for the conditions we investigated. The local evaporation flux distributions associated with thermal conduction were found to vary along the surface of the droplet. Thermal conduction provided a majority of the energy required for evaporation but did not account for all of the energy transport, contributing , and of the energy required for the three cases we examined. Based on the temperature profiles measured along the interface we found that thermocapillary flow was predicted to occur in our experiments, and two convection cells were consistent with the temperature distributions for higher substrate temperatures while a single convection cell was consistent with the temperature distributions for a lower substrate temperature.- 20 January 2017
- Published by American Physical Society (APS) in Physical Review E
- Vol. 95 (1) , 012609
Experimental investigation of interfacial energy transport in an evaporating sessile droplet for evaporative cooling applications
In this paper we experimentally examine evaporation flux distributions and modes of interfacial energy transport for continuously fed evaporating spherical sessile water droplets in a regime that is relevant for applications, particularly for evaporative cooling systems. The contribution of the thermal conduction through the vapor phase was found to be insignificant compared to the thermal conduction through the liquid phase for the conditions we investigated. The local evaporation flux distributions associated with thermal conduction were found to vary along the surface of the droplet. Thermal conduction provided a majority of the energy required for evaporation but did not account for all of the energy transport, contributing , and of the energy required for the three cases we examined. Based on the temperature profiles measured along the interface we found that thermocapillary flow was predicted to occur in our experiments, and two convection cells were consistent with the temperature distributions for higher substrate temperatures while a single convection cell was consistent with the temperature distributions for a lower substrate temperature.