HSHiroshi Shinotsuka

Hiroshi Shinotsuka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hiroshi Shinotsuka has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A data-driven surrogate model for X-ray photoelectron spectroscopy based on survey spectrum background features

    by Shunichi Yoneda, Ryo Murakami, Hiroshi Shinotsuka, Hideki Yoshikawa, Shigeo Tanuma, Hiromi Tanaka, Hayaru Shouno, Kenji Nagata

  • Open Access

    Hard x-ray photoelectron spectroscopy (HAXPES) Cr Kα and XPS Al K α measurements of bulk lithium metal

    by Hideyuki Yasufuku, Tsuyoshi Ohnishi, Shigenori Ueda, Yoshiyuki Yamashita, Hiroshi Shinotsuka, Hideki Yoshikawa, Shigeo Tanuma, Satoshi Kawada, Yoshitaka Matsushita

    Electronic states of bulk lithium were measured by hard x-ray photoelectron spectroscopy and XPS. The samples were measured using Cr Kα and Al Kα excitation sources at 5414.8 and 1486.6 eV, respectively, including survey, Li 1s, O 1s, and F 1s spectra were obtained.

  • Innovative Sample Structure Prediction using Bayesian Estimation and XPS Simulator

    by Hiroshi Shinotsuka, Kenji Nagata, Hideki Yoshikawa, Hayaru Shouno, Masato Okada

    We have developed a framework that integrates the XPS simulator SESSA into Bayesian estimation to solve the inverse problem of XPS. This approach automates the typically labor-intensive task of manually adjusting sample structure parameters for XPS simulation. By incorporating Bayesian methods, we can estimate the distribution of plausible sample structures based on experimental XPS data, providing not only an optimal solution but also a detailed visualization of the solution's distribution. In a case study, we performed angle-resolved XPS on a four-layered sample and successfully estimated the sample structure using this framework. This method streamlines the analysis of XPS data and offers a comprehensive view of sample structures, marking a significant step forward in the application of data science techniques to experimental data.

  • Open Access

    Sample structure prediction from measured XPS data using Bayesian estimation and SESSA simulator

    by Hiroshi Shinotsuka, Kenji Nagata, Malinda Siriwardana, Hideki Yoshikawa, Hayaru Shouno, Masato Okada


  • Open Access

    Automatic estimation of unknown chemical components in a mixed material by XPS analysis using a genetic algorithm

    by Ryo Murakami, Hideki Yoshikawa, Kenji Nagata, Hiroshi Shinotsuka, Hiromi Tanaka, Takeshi Iizuka, Hayaru Shouno

    There is an urgent need to develop automatic analysis methods for the large number of X-ray photoelectron spectroscopy (×PS) spectra being obtained by methods such as 3D chemical analysis and operand analysis. In a previous study, we developed an automatic analysis method for mixed materials that can decompose the XPS spectra and estimate the compositional ratios by comparison with XPS reference spectra of many candidate single-phase compounds. This method needs access to the XPS reference spectrum of every possible compound in the sample. However, in many practical cases, the necessary XPS reference spectra are not always available. In this study, we developed an automatic analysis method to estimate the compositional ratios, even when all necessary XPS reference spectra are not available, i.e. the measured XPS spectra contain unknown peak structures. In particular, the new method can automatically estimate the number of unknown peaks by the combination of a genetic algorithm and the Bayesian information criterion. We applied the method to analyze the depth-resolved XPS spectra of a Pb(Zr,Ti)O3 (PZT) piezoelectric film and successfully identified the change in the chemical states of the components in the film without ambiguity. Graphical abstract


  • Evaluation of dielectric function models for calculation of electron inelastic mean free path

    by B. Da, X. Liu, L. H. Yang, J. M. Gong, Z. J. Ding, H. Shinotsuka, J. W. Liu, H. Yoshikawa, S. Tanuma

    This work investigates the detailed difference between dielectric function models, the Mermin model and the full Penn algorithm (FPA) model, for the determination of an electron inelastic mean free path (IMFP) with optical energy loss function (ELF), as an extension of our previous study [Da et al., Surf. Interface Anal. 51, 627 (2019)] by using the simple Drude-type ELF. In the conventional normal Mermin (NM) model, the approximations of ELF by the Drude equation will introduce inevitable fitting error. In order to enhance the accuracy of the NM model, our previous proposed extended Mermin model [Da et al., Phys. Rev. Lett. 113, 063201 (2014)], which is renamed as a super-extended Mermin algorithm (SE-MA) now, is employed to eliminate the error by expanding the definition of Drude oscillators used in the NM. In the SE-MA, the Drude-like oscillators allow the existence of negative strengths to express the fine structures of phonon–electron scattering and the plasmon lifetime broadening effect. Because in our previous study, the simple Drude-type ELF cannot include these complex structures, in this work, the electron IMFPs are calculated for five realistic materials, Al, Si, Cu, Au, and MgO. The difference between IMFPs calculated by the SE-MA model and the FPA model is material dependent and is significant in the low energy region, which is analyzed by using the Fano plot. This is due to the more important role played by the plasmon lifetime broadening effect.


  • Open Access

    Progress in Fully Automated Analysis System of XPS Spectra Based on Bayesian Information Criterion

    by Hiroshi Shinotsuka

    This is a research report about fully automated analysis of X-ray photoelectron spectroscopy (XPS). We developed a fully automated method to perform XPS spectral analysis based on the information criteria. Our method searches a large number of initial fitting models by changing the degree of smoothing, and obtains a series of fitting results. The goodness of those optimized models is ranked using information criteria. We found that, using the Akaike information criterion, a complicated model tended to be selected, with a larger number of peaks than expected from the spectral shape. On the other hand, using the Bayesian information criterion (BIC), a simple model with reasonably good agreement and a moderate number of peaks was selected. The model selected by the BIC was close to the result of peak fitting performed by XPS analysis experts. We also present the difference in modeling between Gaussian noise and Poisson noise.


  • Calculations of electron inelastic mean free paths. XIII. Data for 14 organic compounds and water over the 50 eV to 200 keV range with the relativistic full Penn algorithm

    by Hiroshi Shinotsuka, Shigeo Tanuma, Cedric J. Powell

    We have calculated inelastic mean free paths (IMFPs) for 14 organic compounds (26‐n‐paraffin, adenine, β‐carotene, diphenyl‐hexatriene, guanine, Kapton, polyacetylene, poly (butene‐1‐sulfone), polyethylene, polymethylmethacrylate, polystyrene, poly(2‐vinylpyridine), thymine, and uracil) and liquid water for electron energies from 50 eV to 200 keV with the relativistic full Penn algorithm including the correction of the bandgap effect in insulators. These calculations were made with energy‐loss functions (ELFs) obtained from measured optical constants and from calculated atomic scattering factors for X‐ray energies. Our calculated IMFPs could be fitted to a modified form of the relativistic Bethe equation for inelastic scattering of electrons in matter from 50 eV to 200 keV. The average root‐mean‐square (RMS) deviation in these fits was 0.17%. The IMFPs were also compared with a relativistic version of our predictive Tanuma–Powell–Penn (TPP‐2M) equation. The average RMS deviation in these comparisons was 7.2% for energies between 50 eV and 200 keV. This average RMS deviation is smaller than that found in a similar comparison for our group of 41 elemental solids (11.9%) and for our group of 42 inorganic compounds (10.7%) for the same energy range. We found generally satisfactory agreement between our calculated IMFPs and values from other calculations for energies between 200 eV and 10 keV. We also found reasonable agreement between our IMFPs for organic compounds and measured IMFPs for energies between 50 eV and 200 keV. Substantial progress for IMFP measurements for liquid water has been made in recent years through the invention of liquid water microjet photoelectron spectroscopy and droplet photoelectron imaging. We found that the IMFPs from these experiments and the associated analyses were larger than our IMFPs by factors between two and four for energies between about 30 eV and 1000 eV. The energy dependences of the measured IMFPs are, however, similar to that of our IMFPs in the same energy range. Since IMFPs calculated from the same algorithm for a number of inorganic compounds agree reasonably well with measured IMFPs for energies between 100 eV and 200 keV, the large differences between IMFPs for water from recent experiments and our results are surprising and need to be resolved with additional experiments.


  • Open Access

    Determination of common peak structure from multiple X-ray photo-electron spectroscopy data sets

    by Ryo Murakami, Hayaru Shouno, Kenji Nagata, Hiroshi Shinotsuka, Hideki Yoshikawa

    X-ray photo-electron spectroscopy (XPS) peak structure (i.e. peak parameters and the number of peaks) offers critical insights in chemical analysis of materials. Reference XPS spectral data are available for single-phases of compounds, as cited in various research papers and databases. Herein, we consider how individual peak structure varies among different reference spectra for the same single-phase of a compound. We developed a technique that automatically estimates common peak structures from multiple spectral data sets. Specifically, we developed a peak separation method that considers both common peak parameters and measurement-derived fluctuations. The proposed method can uniquely estimate the common peak structure of multiple XPS spectral data sets. For example, we applied the proposed approach to Ti 2p XPS results for TiO2 from 15 previous reports. In this way, we confirmed that estimated structure has high interpret-ability. Graphical Abstract


  • Open Access

    Development of spectral decomposition based on Bayesian information criterion with estimation of confidence interval

    by Hiroshi Shinotsuka, Kenji Nagata, Hideki Yoshikawa, Yoh-Ichi Mototake, Hayaru Shouno, Masato Okada

    We develop an automatic peak fitting algorithm using the Bayesian information criterion (BIC) fitting method with confidence-interval estimation in spectral decomposition. First, spectral decomposition is carried out by adopting the Bayesian exchange Monte Carlo method for various artificial spectral data, and the confidence interval of fitting parameters is evaluated. From the results, an approximated model formula that expresses the confidence interval of parameters and the relationship between the peak-to-peak distance and the signal-to-noise ratio is derived. Next, for real spectral data, we compare the confidence interval of each peak parameter obtained using the Bayesian exchange Monte Carlo method with the confidence interval obtained from the BIC-fitting with the model selection function and the proposed approximated formula. We thus confirm that the parameter confidence intervals obtained using the two methods agree well. It is therefore possible to not only simply estimate the appropriate number of peaks by BIC-fitting but also obtain the confidence interval of fitting parameters. Graphical abstract