Lorenzo Reyes-Chamorro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lorenzo Reyes-Chamorro has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Mario Paolone
Distributed Electrical Systems Laboratory, cole Polytechnique Fdrale de Lausanne, Lausanne, Switzerland
16 shared publications Jean-Yves Le Boudec
EPFL, Switzerland
9 shared publicationsAndrey Bernstein
Laboratory for Communications and Applications 2, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
7 shared publications- Rodrigo Palma-Behnke
Department of Electrical Engineering, Faculty of Physical and Mathematical Sciences, University of Chile, Santiago, Chile
5 shared publications - Wajeb Saab
EPFL, Switzerland
4 shared publications - Andreas Martin Kettner
Sales Key Account Management, PSI NEPLAN AG, Ksnacht, Switzerland
3 shared publications
Latest Publications
- 25 December 2024
- Published by Springer Nature
- p. 401-408
Symbiosis Between Urban and Industrial Metabolism
- 25 December 2024
- Published by Springer Nature
- p. 401-408
Symbiosis Between Urban and Industrial Metabolism
- Open Access
- 26 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 85, 427-439
Distributed hydrogen systems: A literature review
- 26 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 85, 427-439
Open AccessDistributed hydrogen systems: A literature review
- Top Cited Papers
- 24 April 2023
- Published by Elsevier in Applied Energy
- Vol. 342
Hierarchical energy management system for multi-microgrid coordination with demand-side management
- 24 April 2023
- Published by Elsevier in Applied Energy
- Vol. 342
Top Cited PapersHierarchical energy management system for multi-microgrid coordination with demand-side management
- Open Access
- 7 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 4650
Identification of Impact Frequency for Down-the-Hole Drills Using Motor Current Signature Analysis
In rotary-percussion drilling, the impact frequency is a crucial variable that is closely linked to operational factors that determine the efficacy of the drilling process, such as the rate of penetration, bit wear, and rock mass characteristics. Typical identification methods rely on complex simulation models or the analysis of different sensor signals installed on specially adapted setups, which are difficult to be implemented in the field. This paper presents a novel study where the impact frequency is identified by motor current signature analysis (MCSA) applied to an induction motor driving a DTH drilling setup. The analysis of the case study begins with the definition of characteristic drilling stages where the pressure and sound signals allow the detection of an impact frequency of 14.10 Hz, which is then used as a reference to validate three MCSA identification approaches. As a result of the analysis, the envelope approach is the most robust for nearly real-time implementations considering its simplicity and range of coverage. Experimental results provide evidence about the feasibility of the proposed MCSA methods to be integrated into Measurement-While-Drilling (MWD) systems to improve drilling condition monitoring and rock mass characterization.
- 7 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 4650
Open AccessIdentification of Impact Frequency for Down-the-Hole Drills Using Motor Current Signature Analysis
In rotary-percussion drilling, the impact frequency is a crucial variable that is closely linked to operational factors that determine the efficacy of the drilling process, such as the rate of penetration, bit wear, and rock mass characteristics. Typical identification methods rely on complex simulation models or the analysis of different sensor signals installed on specially adapted setups, which are difficult to be implemented in the field. This paper presents a novel study where the impact frequency is identified by motor current signature analysis (MCSA) applied to an induction motor driving a DTH drilling setup. The analysis of the case study begins with the definition of characteristic drilling stages where the pressure and sound signals allow the detection of an impact frequency of 14.10 Hz, which is then used as a reference to validate three MCSA identification approaches. As a result of the analysis, the envelope approach is the most robust for nearly real-time implementations considering its simplicity and range of coverage. Experimental results provide evidence about the feasibility of the proposed MCSA methods to be integrated into Measurement-While-Drilling (MWD) systems to improve drilling condition monitoring and rock mass characterization.
- 8 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Flexible Power Point Tracking for Active Power Regulation in String-Inverter PV Plants with Power Optimizers
Large integration of variable renewable resources into modern power grids, has forced grid operators to look for maximizing the available flexibility that can be provided by generators, storage, and loads. In particular, PV plants can provide flexibility by decreasing their active-power injection, following a grid requirement, by using a Flexible Power Point Tracking (FPPT) method. These methods are capable of tracking an external active-power setpoint, that is usually sent by the grid operator, or of tracking the maximum available PV power when the setpoint is larger than what is capable to inject due to the current irradiance. On the other hand, power optimizers (POs) have been proposed as an alternative to minimize the effects of non-uniform conditions in PV systems, by maximizing the power extraction of each PV module. However, FPPT methods have not been implemented on PV plants with POs, where a portion of the active-power requested by the grid must be allocated to each PO. In this paper, we consider a string-inverter PV configuration where the active-power request is distributed among the POs on each PV module. We propose a power-distribution technique that accounts for the individual restrictions of each PV module and PO, while being capable of following the grid's active-power setpoint. We show the results of this proposal through simulations using PLECS ® .
- 8 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Flexible Power Point Tracking for Active Power Regulation in String-Inverter PV Plants with Power Optimizers
Large integration of variable renewable resources into modern power grids, has forced grid operators to look for maximizing the available flexibility that can be provided by generators, storage, and loads. In particular, PV plants can provide flexibility by decreasing their active-power injection, following a grid requirement, by using a Flexible Power Point Tracking (FPPT) method. These methods are capable of tracking an external active-power setpoint, that is usually sent by the grid operator, or of tracking the maximum available PV power when the setpoint is larger than what is capable to inject due to the current irradiance. On the other hand, power optimizers (POs) have been proposed as an alternative to minimize the effects of non-uniform conditions in PV systems, by maximizing the power extraction of each PV module. However, FPPT methods have not been implemented on PV plants with POs, where a portion of the active-power requested by the grid must be allocated to each PO. In this paper, we consider a string-inverter PV configuration where the active-power request is distributed among the POs on each PV module. We propose a power-distribution technique that accounts for the individual restrictions of each PV module and PO, while being capable of following the grid's active-power setpoint. We show the results of this proposal through simulations using PLECS ® .
- Open Access
The Impact of Aging-Preventive Algorithms on BESS Sizing under AGC Performance Standards
It is normally accepted that Battery Energy Storage Systems improve frequency regulation by providing fast response to the Automatic Generation Control. However, currently available control strategies may lead to early Energy Storage Systems aging given that Automatic Generation Control requirements are increasing due to zero carbon power generation integration. In this sense, it is important to analyze the aging phenomena in order to assess the technical–economical usefulness of Battery Energy Storage Systems towards zero carbon power systems. In order to avoid early aging, various proposals on aging-reducing algorithms can be found; however, it is unclear if those aging-reducing algorithms affect the performance of Battery Energy Storage Systems. It is also unclear whether those effects must be internalized to properly dimension the capacity of Battery Energy Storage Systems to both comply with performance standards and to prevent early aging. Thus, this paper estimates the storage capacity of a Battery Energy Storage Systems to comply with Automatic Generation Control performance standard under aging-reducing operating algorithms by dynamics simulations of a reduced-order, empirically-validated model of the Electric Reliability Council of Texas. The results show the relationship between the required performance of Automatic Generation Control and Battery Energy Storage System capacity, considering a 1-year simulation of Automatic Generation Control dynamics. It can be concluded that the compliance with performance standards is strongly related to the storage capacity, regardless of how fast the device can inject or withdraw power from the grid. Previous results in the state-of-the-art overlook the quantification of this relationship between compliance with performance standards and storage capacity.
Open AccessThe Impact of Aging-Preventive Algorithms on BESS Sizing under AGC Performance Standards
It is normally accepted that Battery Energy Storage Systems improve frequency regulation by providing fast response to the Automatic Generation Control. However, currently available control strategies may lead to early Energy Storage Systems aging given that Automatic Generation Control requirements are increasing due to zero carbon power generation integration. In this sense, it is important to analyze the aging phenomena in order to assess the technical–economical usefulness of Battery Energy Storage Systems towards zero carbon power systems. In order to avoid early aging, various proposals on aging-reducing algorithms can be found; however, it is unclear if those aging-reducing algorithms affect the performance of Battery Energy Storage Systems. It is also unclear whether those effects must be internalized to properly dimension the capacity of Battery Energy Storage Systems to both comply with performance standards and to prevent early aging. Thus, this paper estimates the storage capacity of a Battery Energy Storage Systems to comply with Automatic Generation Control performance standard under aging-reducing operating algorithms by dynamics simulations of a reduced-order, empirically-validated model of the Electric Reliability Council of Texas. The results show the relationship between the required performance of Automatic Generation Control and Battery Energy Storage System capacity, considering a 1-year simulation of Automatic Generation Control dynamics. It can be concluded that the compliance with performance standards is strongly related to the storage capacity, regardless of how fast the device can inject or withdraw power from the grid. Previous results in the state-of-the-art overlook the quantification of this relationship between compliance with performance standards and storage capacity.
- Open Access
Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part II: Model Library and Validation
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in Matlab and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGR\'E low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order ($\leqslant$25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.
Open AccessHarmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part II: Model Library and Validation
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in Matlab and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGR\'E low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order ($\leqslant$25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.
- Open Access
Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part I: Modelling Framework and Algorithm
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF) in three-phase grids with CIDERs is proposed. The distinguishing feature of this HPF method is the generic and modular representation of the system components. Notably, as opposed to most of the existing approaches, the coupling between harmonics is explicitly considered. The HPF problem is formulated by combining the hybrid nodal equations of the grid with the closed-loop transfer functions of the CIDERs, and solved using the Newton-Raphson method. The grid components are characterized by compound electrical parameters, which allow to represent both transposed or non-transposed lines. The CIDERs are represented by modular linear time-periodic systems, which allows to treat both grid-forming and grid-following control laws. The method's accuracy and computational efficiency are confirmed via time-domain simulations of the CIGR\'E low-voltage benchmark microgrid. This paper is divided in two parts, which focus on the development (Part I) and the validation (Part II) of the proposed method.
Open AccessHarmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part I: Modelling Framework and Algorithm
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF) in three-phase grids with CIDERs is proposed. The distinguishing feature of this HPF method is the generic and modular representation of the system components. Notably, as opposed to most of the existing approaches, the coupling between harmonics is explicitly considered. The HPF problem is formulated by combining the hybrid nodal equations of the grid with the closed-loop transfer functions of the CIDERs, and solved using the Newton-Raphson method. The grid components are characterized by compound electrical parameters, which allow to represent both transposed or non-transposed lines. The CIDERs are represented by modular linear time-periodic systems, which allows to treat both grid-forming and grid-following control laws. The method's accuracy and computational efficiency are confirmed via time-domain simulations of the CIGR\'E low-voltage benchmark microgrid. This paper is divided in two parts, which focus on the development (Part I) and the validation (Part II) of the proposed method.
- 14 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 458-469
Harmonic Power-Flow Study of Polyphase Grids With Converter-Interfaced Distributed Energy Resources—Part I: Modeling Framework and Algorithm
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF) in three-phase grids with CIDERs is proposed. The distinguishing feature of this HPF method is the generic and modular representation of the system components. Notably, as opposed to most of the existing approaches, the coupling between harmonics is explicitly considered. The HPF problem is formulated by combining the hybrid nodal equations of the grid with the closed-loop transfer functions of the CIDERs, and solved using the Newton-Raphson method. The grid components are characterized by compound electrical parameters, which allow to represent both transposed or non-transposed lines. The CIDERs are represented by modular linear time-periodic systems, which allows to treat both grid-forming and grid-following control laws. The method’s accuracy and computational efficiency are confirmed via time-domain simulations of the CIGRÉ low-voltage benchmark microgrid. This paper is divided in two parts, which focus on the development (Part I) and the validation (Part II) of the proposed method.
- 14 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 458-469
Harmonic Power-Flow Study of Polyphase Grids With Converter-Interfaced Distributed Energy Resources—Part I: Modeling Framework and Algorithm
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF) in three-phase grids with CIDERs is proposed. The distinguishing feature of this HPF method is the generic and modular representation of the system components. Notably, as opposed to most of the existing approaches, the coupling between harmonics is explicitly considered. The HPF problem is formulated by combining the hybrid nodal equations of the grid with the closed-loop transfer functions of the CIDERs, and solved using the Newton-Raphson method. The grid components are characterized by compound electrical parameters, which allow to represent both transposed or non-transposed lines. The CIDERs are represented by modular linear time-periodic systems, which allows to treat both grid-forming and grid-following control laws. The method’s accuracy and computational efficiency are confirmed via time-domain simulations of the CIGRÉ low-voltage benchmark microgrid. This paper is divided in two parts, which focus on the development (Part I) and the validation (Part II) of the proposed method.
- 14 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 470-481
Harmonic Power-Flow Study of Polyphase Grids With Converter-Interfaced Distributed Energy Resources—Part II: Model Library and Validation
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in MATLAB and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGRÉ low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order (≤25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.
- 14 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 470-481
Harmonic Power-Flow Study of Polyphase Grids With Converter-Interfaced Distributed Energy Resources—Part II: Model Library and Validation
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in MATLAB and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGRÉ low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order (≤25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.