SLShenpeng Li

Shenpeng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shenpeng Li has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Centiloid harmonisation across PET cameras without using paired scan

    by Shenpeng Li, Pierrick Bourgeat, Leo Lebrat, Graeme O'KEefe, Jurgen Fripp, Victor L Villemagne, Christopher C. Rowe, Vincent Dore

    Background: The Centiloid (CL) scale allows quantification of amyloid‐b accumulation across multiple PET tracers for the diagnosis of Alzheimer’s disease. The CL quantification on different PET cameras may result in significant quantification bias when merging cohorts acquired from multiple cameras or in the longitudinal studies when change of camera occurs. In this study, we propose a harmonisation method, based on the non‐negative matrix factorisation (NMF), to reduce the quantification bias between different cameras without using paired scans.Method: Three hundred and forty‐eight 18F‐NAV4694 scans from Australian Imaging Biomarkers and Lifestyle study acquired on three PET cameras (N = 116 each), Siemens Biograph mCT, Philips Allegro and Philips Gemini TF64 were used to train the model. Participants who switched camera between two consecutive timepoints were selected as the validation data. Seventeen participants imaged on the Biograph mCT and Gemini (2.63±0.51 years scan interval), and fifty‐two participants imaged on the Gemini and Allegro (2.73±0.73 years). One hundred participants who have two scans (2.26±0.82 years) on Gemini were used to define a reference rate of change (CL/year). Figure 1 illustrates the harmonisation workflow.Result: Figure 2 compares the curves of CL change rate against baseline CL for mCT to Gemini compared to the reference. The harmonised fitting is closer to the reference than the one without harmonisation in the low to middle CL range. The fitting in high CL range (CL>80) deviates from the reference probably because of the lack of subjects in this range. Figure 3 compares the results between Phillips Allegro and Gemini TF 64. The harmonised fitting in Figure 3 is nearly parallel to the reference for the entire CL range. In contrast, the fitting on the unharmonized data shows negative rate of change for the very negative subjects and much higher CL change rate for the very positive subjects, which are strongly different compared to the reference.Conclusion: We propose a practical and economical CL harmonisation for different PET cameras without using paired data. The NMF based method shows promising results for scanner harmonisation, though more validation are needed in future for different PET models.

  • Open Access

    Estimation of simultaneous BOLD and dynamic FDG metabolic brain activations using a multimodality concatenated ICA (mcICA) method

    by Shenpeng Li, Sharna D Jamadar, Phillip G D Ward, Gary F Egan, Zhaolin Chen


  • Open Access

    Improved temporal resolution for mapping brain metabolism using functional PET and anatomical MRI knowledge

    by Viswanath P. Sudarshan, Shenpeng Li, Sharna D. Jamadar, Gary F. Egan, Suyash P. Awate, Zhaolin Chen

    Functional positron emission tomography (fPET) imaging using continuous infusion of [18F]-fluorodeoxyglucose (FDG) is a novel neuroimaging technique to track dynamic glucose utilization in the brain. In comparison to conventional static PET, fPET maintains a sustained supply of glucose in the blood plasma which improves sensitivity to measure dynamic glucose changes in the brain, and enables mapping of dynamic brain activity in task-based and resting-state fPET studies. However, there is a trade-off between temporal resolution and spatial noise due to the low concentration of FDG and the limited sensitivity of multi-ring PET scanners. Images from fPET studies suffer from partial volume errors and residual scatter noise that may cause the cerebral metabolic functional maps to be biased. Gaussian smoothing filters used to denoise the fPET images are suboptimal, as they introduce additional partial volume errors. In this work, a post-processing framework based on a magnetic resonance (MR) Bowsher-like prior was used to improve the spatial and temporal signal to noise characteristics of the fPET images. The performance of the MR guided method was compared with conventional Gaussian filtering using both simulated and in vivo task fPET datasets. The results demonstrate that the MR guided fPET framework reduces the partial volume errors, enhances the sensitivity of identifying brain activation, and improves the anatomical accuracy for mapping changes of brain metabolism in response to a visual stimulation task. The framework extends the use of functional PET to investigate the dynamics of brain metabolic responses for faster presentation of brain activation tasks, and for applications in low dose PET imaging.


  • Open Access

    Analysis of continuous infusion functional PET (fPET) in the human brain

    by Shenpeng Li, Sharna D. Jamadar, Phillip G.D. Ward, Malin Premaratne, Gary F. Egan, Zhaolin Chen


  • Open Access

    Analysis of continuous infusion functional PET (fPET) in the human brain

    by Shenpeng Li, Sharna D. Jamadar, Phillip G.D. Ward, Malin Premaratne, Gary F. Egan, Zhaolin Chen

    Functional positron emission tomography (fPET) is a neuroimaging method involving continuous infusion of 18-F-fluorodeoxyglucose (FDG) radiotracer during the course of the PET examination. Compared with the conventional bolus administered static FDG PET which provides only a snapshot of the averaged glucose uptake into the brain in a limited dynamic time window, fPET offers a significantly wider time window to study the dynamics of glucose uptake. Several earlier studies have applied fPET to investigate brain FDG uptake and study its relationship with functional magnetic resonance imaging (fMRI). However, due to the unique characteristics of fPET signals, modelling of the fPET signal is a complex task and poses challenges for accurate interpretation of the results. This study applies independent component analysis (ICA) to analyze resting state fPET data, and to compare the performance of ICA and general linear modelling (GLM) for estimation of brain activation in response to tasks. The fPET signal characteristics were compared using GLM and ICA methods to model the fPET visual activation data. Our aim was to evaluate GLM and ICA methods for analyzing task fPET datasets and present ICA method in the analysis of resting state fPET datasets. Using both simulation and in-vivo experimental datasets, we show that both methods can successfully identify task related brain activation. We report fPET metabolic resting state brain networks analyzed using the fPET ICA method in a cohort of healthy subjects. Functional PET provides a unique method to map dynamic changes of glucose uptake in the resting human brain and in response to extrinsic stimulation.


  • Open Access

    Constant Infusion Radiotracer Administration for High Temporal Resolution Positron Emission Tomography (PET) of the Human Brain: Application to [18F]-Fluorodexoyglucose PET (FDG-PET)

    by Sharna D Jamadar, Phillip Gd Ward, Alexandra Carey, Richard McIntyre, Linden Parkes, Disha Sasan, John Fallon, Shenpeng Li, Zhaolin Chen, Gary F Egan

    Functional Positron Emission Tomography (fPET) provides a method to track molecular dynamics in the human brain. With a radioactively labelled glucose-analogue, [18F]-flurodeoxyglucose (FDG-fPET), it is now possible to index the dynamics of glucose metabolism with temporal resolutions approaching those of functional magnetic resonance imaging (fMRI). This direct measure of glucose uptake has enormous potential for understanding normal and abnormal brain function, and probing the effects of metabolic and neurodegenerative diseases. Further, new advances in hybrid MR-PET hardware makes it possible to capture fluctuations in glucose and blood oxygenation simultaneously using fMRI and FDG-fPET. The temporal resolution and signal-to-noise of the FDG-fPET images is critically dependent upon the administration of the radioactive tracer. In this work we present two alternative continuous infusion protocols and compare them to a traditional bolus approach. We detail a method for acquiring blood samples, time-locking PET, MRI and experimental stimulus, and administrating the non-traditional tracer delivery. By applying a visual stimulus, we demonstrate cortical maps of the glucose-response to external stimuli on an individual level with a temporal resolution of 16-seconds. Summary Radiotracer infusion protocols for positron emission tomography (PET) provide improved temporal resolution over bolus administration. Here, we describe radiotracer administration for two protocols, constant infusion and bolus plus infusion protocol. We compare this to the standard bolus administration protocol. Using [18-F] fluorodeoxyglucose PET (FDG-PET) as an example, we show that temporal resolutions of approximately 16sec are achievable using these protocols.


  • Simultaneous task-based BOLD-fMRI and [18-F] FDG functional PET for measurement of neuronal metabolism in the human visual cortex

    by Sharna D. Jamadar, Phillip Gd. Ward, Shenpeng Li, Francesco Sforazzini, Jakub Baran, Zhaolin Chen, Gary F. Egan


  • Open Access

    Simultaneous task-based BOLD-fMRI and [18-F] FDG functional PET for measurement of neuronal metabolism in the human visual cortex

    by Sharna D Jamadar, Phillip G D Ward, Shenpeng Li, Francesco Sforazzini, Jakub Baran, Zhaolin Chen, Gary F Egan

    Studies of task-evoked brain activity are the cornerstone of cognitive neuroscience, and unravel the spatial and temporal brain dynamics of cognition in health and disease. Blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI) is one of the most common methods of studying brain function in humans. BOLD-fMRI indirectly infers neuronal activity from regional changes in blood oxygenation and is not a quantitative metric of brain function. Regional variation in glucose metabolism, measured using [18-F] fluorodeoxyglucose positron emission tomography (FDG-PET), provides a more direct and interpretable measure of neuronal activity. However, while the temporal resolution of BOLD-fMRI is in the order of seconds, standard FDG-PET protocols provide a static snapshot of glucose metabolism. Here, we develop a novel experimental design for measurement of task-evoked changes in regional blood oxygenation and glucose metabolism with high temporal resolution. Over a 90-min simultaneous BOLD-fMRI/FDG-PET scan, [18F] FDG was constantly infused to 10 healthy volunteers, who viewed a flickering checkerboard presented in a hierarchical block design. Dynamic task-related changes in blood oxygenation and glucose metabolism were examined with temporal resolution of 2.5sec and 1-min, respectively. Task-related, temporally coherent brain networks of haemodynamic and metabolic connectivity were maximally related in the visual cortex, as expected. Results demonstrate that the hierarchical block design, together with the infusion FDG-PET technique, enabled both modalities to track task-related neural responses with high temporal resolution. The simultaneous MR-PET approach has the potential to provide unique insights into the dynamic haemodynamic and metabolic interactions that underlie cognition in health and disease.


  • From simultaneous to synergistic MR‐PET brain imaging: A review of hybrid MR‐PET imaging methodologies

    by Zhaolin Chen, Sharna D. Jamadar, Shenpeng Li, Francesco Sforazzini, Jakub Baran, Nicholas Ferris, Nadim Jon Shah, Gary F. Egan

    Simultaneous Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) scanning is a recent major development in biomedical imaging. The full integration of the PET detector ring and electronics within the MR system has been a technologically challenging design to develop but provides capacity for simultaneous imaging and the potential for new diagnostic and research capability. This article reviews state‐of‐the‐art MR‐PET hardware and software, and discusses future developments focusing on neuroimaging methodologies for MR‐PET scanning. We particularly focus on the methodologies that lead to an improved synergy between MRI and PET, including optimal data acquisition, PET attenuation and motion correction, and joint image reconstruction and processing methods based on the underlying complementary and mutual information. We further review the current and potential future applications of simultaneous MR‐PET in both systems neuroscience and clinical neuroimaging research. We demonstrate a simultaneous data acquisition protocol to highlight new applications of MR‐PET neuroimaging research studies.


  • FB analysis of PMRI and its application to H∞ optimal sense reconstruction

    by Zhaolin Chen, Jingxin Zhang, Shenpeng Li, Li Chai

    This paper presents a filter bank (FB) analysis of parallel magnetic resonance imaging (PMRI). The underlying image reconstruction strategies of the most widely used PMRI reconstruction methods are unified within the framework and their fundamental perfect reconstruction (PR) constraints are analyzed. Based on this analysis, an improved reconstruction method, called H ∞ optimal sense, is developed and its advantage is demonstrated by an example.