Paola Tellaroli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paola Tellaroli has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Tarantini
Department of Cardiac, Thoracic and Vascular Sciences and Public Health University of Padua Padua Italy
6 shared publications Giuseppe Tarantini
Department of Cardiac, Thoracic and Vascular Sciences, University of Padua Medical School, Padua
5 shared publications- Luca Nai Fovino
Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
5 shared publications - Bernardo Cortese
Harrington Heart & Vascular Institute University Hospitals Cleveland USA
4 shared publications Giuseppe Steffenino
USD Emodinamica, A.S.O. S.Croce e Carle, Cuneo, Italy
4 shared publications- Marco Mojoli
Division of Cardiology, Santa Maria degli Angeli Hospital, Azienda Ospedaliera Friuli Occidentale (ASFO), 33170 Pordenone, Italy
4 shared publications
Latest Publications
- Open Access
Implicit Memory and Anesthesia: A Systematic Review and Meta-Analysis
General anesthesia should induce unconsciousness and provide amnesia. Amnesia refers to the absence of explicit and implicit memories. Unlike explicit memory, implicit memory is not consciously recalled, and it can affect behavior/performance at a later time. The impact of general anesthesia in preventing implicit memory formation is not well-established. We performed a systematic review with meta-analysis of studies reporting implicit memory occurrence in adult patients after deep sedation (Observer’s Assessment of Alertness/Sedation of 0–1 with spontaneous breathing) or general anesthesia. We also evaluated the impact of different anesthetic/analgesic regimens and the time point of auditory task delivery on implicit memory formation. The meta-analysis included the estimation of odds ratios (ORs) and 95% confidence intervals (CIs). We included a total of 61 studies with 3906 patients and 119 different cohorts. For 43 cohorts (36.1%), implicit memory events were reported. The American Society of Anesthesiologists (ASA) physical status III–IV was associated with a higher likelihood of implicit memory formation (OR:3.48; 95%CI:1.18–10.25, p < 0.05) than ASA physical status I–II. Further, there was a lower likelihood of implicit memory formation for deep sedation cases, compared to general anesthesia (OR:0.10; 95%CI:0.01–0.76, p < 0.05) and for patients receiving premedication with benzodiazepines compared to not premedicated patients before general anesthesia (OR:0.35; 95%CI:0.13–0.93, p = 0.05).
Open AccessImplicit Memory and Anesthesia: A Systematic Review and Meta-Analysis
General anesthesia should induce unconsciousness and provide amnesia. Amnesia refers to the absence of explicit and implicit memories. Unlike explicit memory, implicit memory is not consciously recalled, and it can affect behavior/performance at a later time. The impact of general anesthesia in preventing implicit memory formation is not well-established. We performed a systematic review with meta-analysis of studies reporting implicit memory occurrence in adult patients after deep sedation (Observer’s Assessment of Alertness/Sedation of 0–1 with spontaneous breathing) or general anesthesia. We also evaluated the impact of different anesthetic/analgesic regimens and the time point of auditory task delivery on implicit memory formation. The meta-analysis included the estimation of odds ratios (ORs) and 95% confidence intervals (CIs). We included a total of 61 studies with 3906 patients and 119 different cohorts. For 43 cohorts (36.1%), implicit memory events were reported. The American Society of Anesthesiologists (ASA) physical status III–IV was associated with a higher likelihood of implicit memory formation (OR:3.48; 95%CI:1.18–10.25, p < 0.05) than ASA physical status I–II. Further, there was a lower likelihood of implicit memory formation for deep sedation cases, compared to general anesthesia (OR:0.10; 95%CI:0.01–0.76, p < 0.05) and for patients receiving premedication with benzodiazepines compared to not premedicated patients before general anesthesia (OR:0.35; 95%CI:0.13–0.93, p = 0.05).
- 3 November 2020
- Published by Elsevier in Environmental Research
- Vol. 191, 110233
Cancerogenic effects of radiofrequency radiation: A statistical reappraisal
- 3 November 2020
- Published by Elsevier in Environmental Research
- Vol. 191, 110233
Cancerogenic effects of radiofrequency radiation: A statistical reappraisal
- 12 December 2019
- Published by Taylor & Francis in Communications in Statistics - Simulation and Computation
- Vol. 51 (5) , 2412-2428
SingleCross-clustering: an algorithm for finding elongated clusters with automatic estimation of outliers and number of clusters
Many clustering methods perform well with spherical clusters but poorly with elongated clusters. The Single-linkage method is suitable for finding such type of long clusters, but it can be sensitive to outliers and noise in the data, causing the so-called chain-effect. This work proposes a modification of Cross-Clustering algorithm, the SingleCross-Clustering (SCC), a partial clustering algorithm that estimates the number of clusters, recognizes outliers and that is useful for the identification of elongated clusters. SCC has been validated by comparing it with a number of existing clustering methods, showing on both simulated and real datasets that SCC is a reliable solution for the identification of the correct number of clusters and of the number of clusters memberships. The algorithm has been implemented in the R package CrossClustering, which can be downloaded for free from the CRAN contributed package repository.
- 12 December 2019
- Published by Taylor & Francis in Communications in Statistics - Simulation and Computation
- Vol. 51 (5) , 2412-2428
SingleCross-clustering: an algorithm for finding elongated clusters with automatic estimation of outliers and number of clusters
Many clustering methods perform well with spherical clusters but poorly with elongated clusters. The Single-linkage method is suitable for finding such type of long clusters, but it can be sensitive to outliers and noise in the data, causing the so-called chain-effect. This work proposes a modification of Cross-Clustering algorithm, the SingleCross-Clustering (SCC), a partial clustering algorithm that estimates the number of clusters, recognizes outliers and that is useful for the identification of elongated clusters. SCC has been validated by comparing it with a number of existing clustering methods, showing on both simulated and real datasets that SCC is a reliable solution for the identification of the correct number of clusters and of the number of clusters memberships. The algorithm has been implemented in the R package CrossClustering, which can be downloaded for free from the CRAN contributed package repository.
- 1 November 2019
- Published by University of Chicago Press in The American Naturalist
- Vol. 194 (5) , E134-E139
Information about Predators Varies across an Amazonian Rain Forest as a Result of Sentinel Species Distribution
Information about predation risk is of fundamental value in biological communities. Because many prey species have shared predators, eavesdropping on other species' alarms is a widely recognized mechanism underlying the formation of mixed-species groups. However, information transfer may vary both across and within groups because some species provide higher-quality information about predators than others. We tested this phenomenon in Amazonian understory mixed-species flocks of birds in which two sentinel species-the bluish-slate antshrike (Thamnomanes schistogynus) and the dusky-throated antshrike (Thamnomanes ardesiacus)-occupy different habitats and provide alarm calls that are used by eavesdropping flock mates. In a playback experiment, two associate species responded significantly more strongly to alarm calls from the same sentinel species, reflecting the greater reliability of information about predator threats that could affect survival and habitat choice. Our work provides evidence of a repeated asymmetry across space in the available information about threats.
- 1 November 2019
- Published by University of Chicago Press in The American Naturalist
- Vol. 194 (5) , E134-E139
Information about Predators Varies across an Amazonian Rain Forest as a Result of Sentinel Species Distribution
Information about predation risk is of fundamental value in biological communities. Because many prey species have shared predators, eavesdropping on other species' alarms is a widely recognized mechanism underlying the formation of mixed-species groups. However, information transfer may vary both across and within groups because some species provide higher-quality information about predators than others. We tested this phenomenon in Amazonian understory mixed-species flocks of birds in which two sentinel species-the bluish-slate antshrike (Thamnomanes schistogynus) and the dusky-throated antshrike (Thamnomanes ardesiacus)-occupy different habitats and provide alarm calls that are used by eavesdropping flock mates. In a playback experiment, two associate species responded significantly more strongly to alarm calls from the same sentinel species, reflecting the greater reliability of information about predator threats that could affect survival and habitat choice. Our work provides evidence of a repeated asymmetry across space in the available information about threats.
- Open Access
- 1 November 2018
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 19 (11) , 655-663
Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve
Background: New-generation transcatheter heart valves have been developed to reduce complications of transcatheter aortic valve implantation (TAVI). With this study we sought to compare procedural and 30-day outcomes of the new-generation repositionable Boston Scientific Lotus (Lotus) and the balloon-expandable Edwards Sapien 3 (ES3) transcatheter heart valves. Methods: A total of 315 patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI with Lotus or ES3 included in two large Italian registries were considered for this analysis. After propensity matching, 93 matched pairs of patients were included. Outcomes were evaluated according to Valve Academic Research Consortium-2 definition at discharge and 30 days. Results: There were no differences in baseline characteristics, except for lower mean aortic gradient and larger mean aortic annulus in the ES3-treated patients. Valve Academic Research Consortium-2 defined device success was high and comparable between groups (97.8 for Lotus vs. 98.9% for ES3, P = 0.09). The frequency of moderate/severe paravalvular leak was low and similar for both devices (2.2 vs. 1.1%, P = 0.10). At 30 days, both groups showed low all-cause mortality (5.4 vs. 1.1%, P = 0.10) and rates of disabling stroke (3.2 vs. 1.1%, P = 0.31). New pacemaker implantation was more common after Lotus deployment (31.7 vs. 10.5%, P < 0.001). Conclusion: Transfemoral TAVI with both Lotus and ES3 resulted in favorable clinical and hemodynamic procedural and 30-day outcomes. Rates of significant paravalvular leak were low with both devices. The Lotus valve was associated with higher risk of pacemaker implantation.
- 1 November 2018
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 19 (11) , 655-663
Open AccessTransfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve
Background: New-generation transcatheter heart valves have been developed to reduce complications of transcatheter aortic valve implantation (TAVI). With this study we sought to compare procedural and 30-day outcomes of the new-generation repositionable Boston Scientific Lotus (Lotus) and the balloon-expandable Edwards Sapien 3 (ES3) transcatheter heart valves. Methods: A total of 315 patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI with Lotus or ES3 included in two large Italian registries were considered for this analysis. After propensity matching, 93 matched pairs of patients were included. Outcomes were evaluated according to Valve Academic Research Consortium-2 definition at discharge and 30 days. Results: There were no differences in baseline characteristics, except for lower mean aortic gradient and larger mean aortic annulus in the ES3-treated patients. Valve Academic Research Consortium-2 defined device success was high and comparable between groups (97.8 for Lotus vs. 98.9% for ES3, P = 0.09). The frequency of moderate/severe paravalvular leak was low and similar for both devices (2.2 vs. 1.1%, P = 0.10). At 30 days, both groups showed low all-cause mortality (5.4 vs. 1.1%, P = 0.10) and rates of disabling stroke (3.2 vs. 1.1%, P = 0.31). New pacemaker implantation was more common after Lotus deployment (31.7 vs. 10.5%, P < 0.001). Conclusion: Transfemoral TAVI with both Lotus and ES3 resulted in favorable clinical and hemodynamic procedural and 30-day outcomes. Rates of significant paravalvular leak were low with both devices. The Lotus valve was associated with higher risk of pacemaker implantation.
- 1 July 2018
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 121 (1) , 198-209
Isolated forearm technique: a meta-analysis of connected consciousness during different general anaesthesia regimens
- 1 July 2018
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 121 (1) , 198-209
Isolated forearm technique: a meta-analysis of connected consciousness during different general anaesthesia regimens
- 7 March 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (2) , E115-E124
Absorb bioresorbable vascular scaffold vs. everolimus‐eluting metallic stent in small vessel disease: A propensity matched analysis of COMPARE II, RAI, and MAASSTAD‐ABSORB studies
Background: Patients with small vessel disease (SVD) are at higher risk of adverse events after PCI compared to non‐SVD patients. In this subset, the use of bioresorbable vascular scaffolds (BVS) has raised particular concern.Objective: We aimed to compare outcomes of Absorb BVS versus a 2nd‐generation metallic everolimus‐eluting stents (EES) in the SVD setting, by pooling patients from three large, prospective studies.Methods: Patients with SVD (reference vessel diameter ≤2.75 mm by QCA) and treated with Absorb BVS were identified in the Italian RAI and the MAASSTAD‐Absorb registries. EES controls were identified in the COMPARE II Trial. We performed a propensity‐score matching using several clinical and angiographic variables. Implantation technique was not object of matching, being device‐specific.Results: Out of 4635 enrolled subjects, 1147 belonged to the SVD population. After matching, we obtained 337 pairs of patients. High clinical and angiographic complexity was found in both groups. Predilation and postdilation rates were significantly higher in BVS patients. No differences were found in terms of the device‐oriented composite end‐point at 1‐year (HR = 1.08, 95%CI 0.5–2.3, P = .8) and 2‐years (HR = 1.28, 95% CI: 0.68–2.43, P = .5). Notwithstanding, higher incidence of definite/probable stent thrombosis was observed in the BVS group at 1 year (HR 4.7, 95%CI 0.8–31.4, P = .08) and 2‐years (HR = 8.34 95%CI 1.1–60.2, P = .04).Conclusion: In this propensity‐matched analysis pooling SVD patients of three large prospective studies, incidence of composite device‐related events was comparable between BVS and EES up to 2 years follow‐up. However, higher rates of stent thrombosis were found in the BVS group.
- 7 March 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (2) , E115-E124
Absorb bioresorbable vascular scaffold vs. everolimus‐eluting metallic stent in small vessel disease: A propensity matched analysis of COMPARE II, RAI, and MAASSTAD‐ABSORB studies
Background: Patients with small vessel disease (SVD) are at higher risk of adverse events after PCI compared to non‐SVD patients. In this subset, the use of bioresorbable vascular scaffolds (BVS) has raised particular concern.Objective: We aimed to compare outcomes of Absorb BVS versus a 2nd‐generation metallic everolimus‐eluting stents (EES) in the SVD setting, by pooling patients from three large, prospective studies.Methods: Patients with SVD (reference vessel diameter ≤2.75 mm by QCA) and treated with Absorb BVS were identified in the Italian RAI and the MAASSTAD‐Absorb registries. EES controls were identified in the COMPARE II Trial. We performed a propensity‐score matching using several clinical and angiographic variables. Implantation technique was not object of matching, being device‐specific.Results: Out of 4635 enrolled subjects, 1147 belonged to the SVD population. After matching, we obtained 337 pairs of patients. High clinical and angiographic complexity was found in both groups. Predilation and postdilation rates were significantly higher in BVS patients. No differences were found in terms of the device‐oriented composite end‐point at 1‐year (HR = 1.08, 95%CI 0.5–2.3, P = .8) and 2‐years (HR = 1.28, 95% CI: 0.68–2.43, P = .5). Notwithstanding, higher incidence of definite/probable stent thrombosis was observed in the BVS group at 1 year (HR 4.7, 95%CI 0.8–31.4, P = .08) and 2‐years (HR = 8.34 95%CI 1.1–60.2, P = .04).Conclusion: In this propensity‐matched analysis pooling SVD patients of three large prospective studies, incidence of composite device‐related events was comparable between BVS and EES up to 2 years follow‐up. However, higher rates of stent thrombosis were found in the BVS group.
- 1 November 2017
- Published by Elsevier in International Journal of Cardiology
- Vol. 246, 37-40
TAVR with mechanically expandable prostheses: Is balloon aortic valvuloplasty really necessary?
- 1 November 2017
- Published by Elsevier in International Journal of Cardiology
- Vol. 246, 37-40
TAVR with mechanically expandable prostheses: Is balloon aortic valvuloplasty really necessary?
- 1 October 2017
- Published by Elsevier in American Heart Journal
- Vol. 192, 64-75
Impact of atrial fibrillation on outcomes of patients treated by transcatheter aortic valve implantation: A systematic review and meta-analysis
- 1 October 2017
- Published by Elsevier in American Heart Journal
- Vol. 192, 64-75
Impact of atrial fibrillation on outcomes of patients treated by transcatheter aortic valve implantation: A systematic review and meta-analysis