Fatemeh Salemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fatemeh Salemi has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Maryam Farhadian
Department of Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
5 shared publications - Abbas Shokri
Department of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
4 shared publications Abbas Shokri
3 shared publications- Samira Saati
Department of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
3 shared publications Maryam Farhadian
Department of Oral and Maxillofacial Radiology, Dental School
2 shared publications- Nika Nafisi
Department of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
2 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by XMLink in Imaging Science in Dentistry
- Vol. 55 (1) , 11-21
Comparative accuracy of artificial intelligence-based AudaxCeph software, Dolphin software, and the manual technique for orthodontic landmark identification and tracing of lateral cephalograms
Foroozandeh M, et al. Imaging Sci Dent. 2024 Dec;54:e46. https://doi.org/10.5624/isd.20240089
- 1 January 2024
- Published by XMLink in Imaging Science in Dentistry
- Vol. 55 (1) , 11-21
Open AccessComparative accuracy of artificial intelligence-based AudaxCeph software, Dolphin software, and the manual technique for orthodontic landmark identification and tracing of lateral cephalograms
Foroozandeh M, et al. Imaging Sci Dent. 2024 Dec;54:e46. https://doi.org/10.5624/isd.20240089
- Open Access
- 1 July 2021
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 11 (3) , 305-314
Efficacy of Metal Artifact Reduction Algorithm of Cone-Beam Computed Tomography for Detection of Fenestration and Dehiscence around Dental Implants
Background: Beam hardening and scattering artifacts from high-density objects such as dental implants adversely affect the image quality and subsequently the detection of fenestration or dehiscence around dental implants. Objective: This study aimed to assess the efficacy of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) systems for detection of peri-implant fenestration and dehiscence.Material and Methods: In this experimental study, thirty-six titanium implants were placed in bone blocks of bovine ribs. Fenestration and dehiscence were created in the buccal bone around implants. CBCT images were obtained using Cranex 3D and ProMax 3D CBCT systems with and without MAR algorithm. Two experienced radiologists observed the images. Data were analyzed using SPSS software. The Kappa coefficient of agreement, the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, and accuracy of different imaging modalities were calculated and analyzed. Results: In both CBCT systems, the use of MAR algorithm decreased the area under the ROC curve and subsequently the diagnostic accuracy for the detection of fenestration and dehiscence. The sensitivity, specificity and accuracy of both CBCT systems were higher in absence of the MAR algorithm. The specificity of ProMax 3D for detection of fenestration was equal with/without the MAR algorithm. Conclusion: Although CBCT is suitable for detection of peri-implant defects, the application of the MAR algorithm does not enhance the detection of peri-implant fenestration and dehiscence.
- 1 July 2021
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 11 (3) , 305-314
Open AccessEfficacy of Metal Artifact Reduction Algorithm of Cone-Beam Computed Tomography for Detection of Fenestration and Dehiscence around Dental Implants
Background: Beam hardening and scattering artifacts from high-density objects such as dental implants adversely affect the image quality and subsequently the detection of fenestration or dehiscence around dental implants. Objective: This study aimed to assess the efficacy of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) systems for detection of peri-implant fenestration and dehiscence.Material and Methods: In this experimental study, thirty-six titanium implants were placed in bone blocks of bovine ribs. Fenestration and dehiscence were created in the buccal bone around implants. CBCT images were obtained using Cranex 3D and ProMax 3D CBCT systems with and without MAR algorithm. Two experienced radiologists observed the images. Data were analyzed using SPSS software. The Kappa coefficient of agreement, the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, and accuracy of different imaging modalities were calculated and analyzed. Results: In both CBCT systems, the use of MAR algorithm decreased the area under the ROC curve and subsequently the diagnostic accuracy for the detection of fenestration and dehiscence. The sensitivity, specificity and accuracy of both CBCT systems were higher in absence of the MAR algorithm. The specificity of ProMax 3D for detection of fenestration was equal with/without the MAR algorithm. Conclusion: Although CBCT is suitable for detection of peri-implant defects, the application of the MAR algorithm does not enhance the detection of peri-implant fenestration and dehiscence.
- Open Access
- 1 January 2021
- Published by Korean Academy of Oral and Maxillofacial Radiology in Imaging Science in Dentistry
- Vol. 51 (2) , 167-174
Morphometric analysis of the inter-mastoid triangle for sex determination: Application of statistical shape analysis
Sobhani F, et al. Imaging Sci Dent. 2021 Jan;51:e22. https://doi.org/10.5624/isd.20200297
- 1 January 2021
- Published by Korean Academy of Oral and Maxillofacial Radiology in Imaging Science in Dentistry
- Vol. 51 (2) , 167-174
Open AccessMorphometric analysis of the inter-mastoid triangle for sex determination: Application of statistical shape analysis
Sobhani F, et al. Imaging Sci Dent. 2021 Jan;51:e22. https://doi.org/10.5624/isd.20200297
- Open Access
- 22 December 2020
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 24 (1) , 9 P
Sex determination by osteometric assessment of the mastoid process using Cone Beam Computed Tomography
Objective: Sex determination is one of the most important parameters to identify in forensic science. Because the mastoid process is the most resistant to damage due to its position in the skull base, it can be used for sex determination. The purpose of this study was to measure the dimensions and convexity and internal angles of the mastoid process to present a model of sex determination in Iranian population. Material and methods: This study was performed on three-dimensional images of 190 Cone Beam Computed Tomography (CBCT) of 105 women and 85 men. On each CBCT the distance between the porion and the mastoid (PM), mastoid length (ML), the distance between the mastoidale and the mastoid incision (M-I), the mastoid height (MH), the mastoid width (MW), intermastoidale distance (IMD) the lateral surfaces of the left and right mastoids (IMLSD) and the Mastoid medial convergence angle (MMCA) was measured on both the right and the left. The data were analyzed by descriptive statistics, t-test, and discriminant function analysis. Results: Significant differences were found for all variables except MMCA and MF in both sex. All measured variables except MW were greater for men than women. The discriminant model achieved a total accuracy of 93.7%. Among the measured factors IMD and IMSLD had the most influence on sex determination. Conclusion: Measuring the dimensions of the mastoid process is a very good method for sex determination with high accuracy of 90%. KEYWORDS Discriminant model; Cone beam computed tomography (CBCT); Sex determination; Mastoid process.
- 22 December 2020
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 24 (1) , 9 P
Open AccessSex determination by osteometric assessment of the mastoid process using Cone Beam Computed Tomography
Objective: Sex determination is one of the most important parameters to identify in forensic science. Because the mastoid process is the most resistant to damage due to its position in the skull base, it can be used for sex determination. The purpose of this study was to measure the dimensions and convexity and internal angles of the mastoid process to present a model of sex determination in Iranian population. Material and methods: This study was performed on three-dimensional images of 190 Cone Beam Computed Tomography (CBCT) of 105 women and 85 men. On each CBCT the distance between the porion and the mastoid (PM), mastoid length (ML), the distance between the mastoidale and the mastoid incision (M-I), the mastoid height (MH), the mastoid width (MW), intermastoidale distance (IMD) the lateral surfaces of the left and right mastoids (IMLSD) and the Mastoid medial convergence angle (MMCA) was measured on both the right and the left. The data were analyzed by descriptive statistics, t-test, and discriminant function analysis. Results: Significant differences were found for all variables except MMCA and MF in both sex. All measured variables except MW were greater for men than women. The discriminant model achieved a total accuracy of 93.7%. Among the measured factors IMD and IMSLD had the most influence on sex determination. Conclusion: Measuring the dimensions of the mastoid process is a very good method for sex determination with high accuracy of 90%. KEYWORDS Discriminant model; Cone beam computed tomography (CBCT); Sex determination; Mastoid process.
- Open Access
- 15 January 2020
- Published by Springer Nature in Egyptian Journal of Forensic Sciences
- Vol. 10 (1) , 1-8
Age estimation by pulp to tooth area ratio in canine teeth using cone-beam computed tomography
Background: This study aimed to estimate the chronological age of individuals according to the correlation of age with morphological variables of the maxillary canine teeth using cone-beam computed tomography (CBCT) based on Kvaal’s method.Method: This study was conducted on CBCT scans of 300 patients in Hamadan city, including 142 females and 158 males between 14 and 60 years of age. To measure the morphological variables, cross-sectional views of the maxillary right canine tooth were studied. The pulp to tooth area ratio (AR), the pulp to tooth length ratio (P), the mesiodistal and the buccolingual pulp to tooth width ratio at the cementoenamel junction (CEJ) (A1, A2), the mesiodistal and buccolingual pulp to tooth width ratio at the mid-root (C1, C2), and the mesiodistal and buccolingual pulp to tooth width ratio at the midpoint between the CEJ and the mid-root (B1, B2) were measured on CBCT scans.Results: A significant inverse correlation was noted between age and all measured variables. No significant difference was found in the mean variables between males and females. The correlation between the actual age and estimated age in the regression model was 0.88. The mean square error (MSE) of prediction was 5.89 years; also, the mean absolute error (MAE) was 4.46 years.Conclusion: The fitted regression model suggested in this study can estimate the age of individuals with acceptable accuracy and mean absolute error of lower than 5 years.
- 15 January 2020
- Published by Springer Nature in Egyptian Journal of Forensic Sciences
- Vol. 10 (1) , 1-8
Open AccessAge estimation by pulp to tooth area ratio in canine teeth using cone-beam computed tomography
Background: This study aimed to estimate the chronological age of individuals according to the correlation of age with morphological variables of the maxillary canine teeth using cone-beam computed tomography (CBCT) based on Kvaal’s method.Method: This study was conducted on CBCT scans of 300 patients in Hamadan city, including 142 females and 158 males between 14 and 60 years of age. To measure the morphological variables, cross-sectional views of the maxillary right canine tooth were studied. The pulp to tooth area ratio (AR), the pulp to tooth length ratio (P), the mesiodistal and the buccolingual pulp to tooth width ratio at the cementoenamel junction (CEJ) (A1, A2), the mesiodistal and buccolingual pulp to tooth width ratio at the mid-root (C1, C2), and the mesiodistal and buccolingual pulp to tooth width ratio at the midpoint between the CEJ and the mid-root (B1, B2) were measured on CBCT scans.Results: A significant inverse correlation was noted between age and all measured variables. No significant difference was found in the mean variables between males and females. The correlation between the actual age and estimated age in the regression model was 0.88. The mean square error (MSE) of prediction was 5.89 years; also, the mean absolute error (MAE) was 4.46 years.Conclusion: The fitted regression model suggested in this study can estimate the age of individuals with acceptable accuracy and mean absolute error of lower than 5 years.
- Open Access
- 1 January 2020
- Published by XMLink in Imaging Science in Dentistry
- Vol. 50 (4) , 323-330
Comparison of data mining algorithms for sex determination based on mastoid process measurements using cone-beam computed tomography
Farhadian M, et al. Imaging Sci Dent. 2020 Dec;50(4):323-330. https://doi.org/10.5624/isd.2020.50.4.323
- 1 January 2020
- Published by XMLink in Imaging Science in Dentistry
- Vol. 50 (4) , 323-330
Open AccessComparison of data mining algorithms for sex determination based on mastoid process measurements using cone-beam computed tomography
Farhadian M, et al. Imaging Sci Dent. 2020 Dec;50(4):323-330. https://doi.org/10.5624/isd.2020.50.4.323
- Open Access
- 1 January 2019
- Published by XMLink in Imaging Science in Dentistry
- Vol. 49 (1) , 19-26
Dental age estimation using the pulp-to-tooth ratio in canines by neural networks
Farhadian M, et al. Imaging Sci Dent. 2019 Mar;49(1):19-26. https://doi.org/10.5624/isd.2019.49.1.19
- 1 January 2019
- Published by XMLink in Imaging Science in Dentistry
- Vol. 49 (1) , 19-26
Open AccessDental age estimation using the pulp-to-tooth ratio in canines by neural networks
Farhadian M, et al. Imaging Sci Dent. 2019 Mar;49(1):19-26. https://doi.org/10.5624/isd.2019.49.1.19
- Open Access
- 30 June 2016
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 53 (2) , 186-192
A Comparative Study of the Diagnostic Accuracy of Cone Beam Computed Tomography and Phosphor Storage Plate for Detection of Noncavitated Occlusal Caries
- 30 June 2016
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 53 (2) , 186-192
Open AccessA Comparative Study of the Diagnostic Accuracy of Cone Beam Computed Tomography and Phosphor Storage Plate for Detection of Noncavitated Occlusal Caries
- 1 May 2016
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 27 (3) , 644-648
Effect of Field of View on Detection of Condyle Bone Defects Using Cone Beam Computed Tomography
In maxillofacial imaging, cone beam computed tomography (CBCT) is currently the modality of choice for assessment of bony structures of the temporomandibular joint (TMJ). Factors affecting the quality of CBCT images can change its diagnostic accuracy. This study aimed to assess the effect of field of view (FOV) and defect size on the accuracy of CBCT scans for detection of bone defects of the TMJs. This study was conducted on 12 sound TMJs of 6 human dry skulls. Erosions and osteophytes were artificially induced in 0.5, 1, and 1.5-mm sizes on the anterior-superior part of the condyle; CBCT scans were obtained with 6, 9, and 12-inch FOVs by NewTom 3G CBCT system. Two maxillofacial radiologists evaluated the presence/absence and type of defects on CBCT scans. The Cohen kappa was calculated to assess intra- and interobserver reliability. The Mann–Whitney U test was applied to compare the diagnostic accuracy of different FOVs. In comparison of 6- and 12-inch, 9- and 12-inch FOVs in detection of different sizes of erosive lesions, difference was significant (P P = 0.04). In comparison of 6- and 12-inch FOVs in detection of different sizes of osteophyte lesion, difference was significant (P < 0.05), whereas between 6- and 9-inch FOVs statistically significant difference was not observed (P > 0.05). The highest and the lowest diagnostic accuracy of CBCT scans for condyle defects were obtained with 6-inch and 12-inch FOVs, respectively. Diagnostic accuracy of CBCT scans increased with an increase in size of bone defects.
- 1 May 2016
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 27 (3) , 644-648
Effect of Field of View on Detection of Condyle Bone Defects Using Cone Beam Computed Tomography
In maxillofacial imaging, cone beam computed tomography (CBCT) is currently the modality of choice for assessment of bony structures of the temporomandibular joint (TMJ). Factors affecting the quality of CBCT images can change its diagnostic accuracy. This study aimed to assess the effect of field of view (FOV) and defect size on the accuracy of CBCT scans for detection of bone defects of the TMJs. This study was conducted on 12 sound TMJs of 6 human dry skulls. Erosions and osteophytes were artificially induced in 0.5, 1, and 1.5-mm sizes on the anterior-superior part of the condyle; CBCT scans were obtained with 6, 9, and 12-inch FOVs by NewTom 3G CBCT system. Two maxillofacial radiologists evaluated the presence/absence and type of defects on CBCT scans. The Cohen kappa was calculated to assess intra- and interobserver reliability. The Mann–Whitney U test was applied to compare the diagnostic accuracy of different FOVs. In comparison of 6- and 12-inch, 9- and 12-inch FOVs in detection of different sizes of erosive lesions, difference was significant (P P = 0.04). In comparison of 6- and 12-inch FOVs in detection of different sizes of osteophyte lesion, difference was significant (P < 0.05), whereas between 6- and 9-inch FOVs statistically significant difference was not observed (P > 0.05). The highest and the lowest diagnostic accuracy of CBCT scans for condyle defects were obtained with 6-inch and 12-inch FOVs, respectively. Diagnostic accuracy of CBCT scans increased with an increase in size of bone defects.