Margarida Eiras
Research Subjects
Margarida Eiras has a total of 133 co-authors. Here are the top co-authors by number of shared publications:
- Ana Escoval
Universidade Nova de Lisboa
11 shared publications A. Depaigne-Loth
9 shared publicationsA. Livio
9 shared publicationsE. Klaus
9 shared publicationsF. Almeman
9 shared publicationsF. Saillour-Glenisson
9 shared publications
Latest Publications
- Open Access
- 10 February 2023
- Published by MDPI AG in Education Sciences
- Vol. 13 (2) , 189
Determinants Influencing Distance Learning at Health Technology Higher Education Institutions in Portugal
Introducing distance learning within higher education institutions (HEIs) is a key societal issue, especially in the health sector, due to its in vivo learning nature. Public policies play an important role in these digital environments. This study aims to identify the determinants influencing national public policies that foster digital learning transformation in Health HEIs in Portugal. A prospective survey, using the structural analysis of Godet’s method, is conducted, and data are gathered from different health sector stakeholders. Despite the efforts to increase digital literacy and funding toward digital learning in HEIs, a weak strategy and implementation of a national plan for distance learning in Health HEIs are still prevalent. The driver to success is grounded on national and international cooperation between health professionals, hospitals, and HEIs through transferability processes of innovative practices.
- 10 February 2023
- Published by MDPI AG in Education Sciences
- Vol. 13 (2) , 189
Open AccessDeterminants Influencing Distance Learning at Health Technology Higher Education Institutions in Portugal
Introducing distance learning within higher education institutions (HEIs) is a key societal issue, especially in the health sector, due to its in vivo learning nature. Public policies play an important role in these digital environments. This study aims to identify the determinants influencing national public policies that foster digital learning transformation in Health HEIs in Portugal. A prospective survey, using the structural analysis of Godet’s method, is conducted, and data are gathered from different health sector stakeholders. Despite the efforts to increase digital literacy and funding toward digital learning in HEIs, a weak strategy and implementation of a national plan for distance learning in Health HEIs are still prevalent. The driver to success is grounded on national and international cooperation between health professionals, hospitals, and HEIs through transferability processes of innovative practices.
- Open Access
- 1 November 2021
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 28 (6) , 332-352
Documento de consenso SEDAR/SECCE sobre el manejo de ECMO
- 1 November 2021
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 28 (6) , 332-352
Open AccessDocumento de consenso SEDAR/SECCE sobre el manejo de ECMO
- Open Access
- 1 January 2020
- Published by Taylor & Francis in Therapeutics and Clinical Risk Management
- Vol. 16, 1175-1183
Translation, Cross-Cultural Adaptation, and Measurement Properties of the Portuguese Version of the Global Trigger Tool for Adverse Events
Purpose: To adapt and validate the Global Trigger Tool (IHI-GTT), which identifies and analyzes adverse events (AE) in hospitalized patients and their measurement properties in the Portuguese context. Methods: A retrospective cross-sectional study was based on a random sample of 90 medical records. The stages of translation and cross-cultural adaptation of the IHI-GTT were based on the Cross-Cultural Adaptation Protocol that originated from the Portuguese version, GTT-PT, for the hospital context in medical-surgical departments. Internal consistency, reliability, reproducibility, diagnostic tests, and discriminatory predictive value were investigated. Results: The final phase of the GTT-PT showed insignificant inconsistencies. The pre-test phase confirmed translation accuracy, easy administration, effectiveness in identifying AEs, and relevance of integrating it into hospital risk management. It had a sensitivity of 97.8% and specificity of 74.8%, with a cutoff point of 0.5, an accuracy of 83%, and a positive predictive value of 69.8% and a negative predictive value of 0.98%. Conclusion: The GTT-PT is a reliable, accurate, and valid tool to identify AE, with robust measurement properties.
- 1 January 2020
- Published by Taylor & Francis in Therapeutics and Clinical Risk Management
- Vol. 16, 1175-1183
Open AccessTranslation, Cross-Cultural Adaptation, and Measurement Properties of the Portuguese Version of the Global Trigger Tool for Adverse Events
Purpose: To adapt and validate the Global Trigger Tool (IHI-GTT), which identifies and analyzes adverse events (AE) in hospitalized patients and their measurement properties in the Portuguese context. Methods: A retrospective cross-sectional study was based on a random sample of 90 medical records. The stages of translation and cross-cultural adaptation of the IHI-GTT were based on the Cross-Cultural Adaptation Protocol that originated from the Portuguese version, GTT-PT, for the hospital context in medical-surgical departments. Internal consistency, reliability, reproducibility, diagnostic tests, and discriminatory predictive value were investigated. Results: The final phase of the GTT-PT showed insignificant inconsistencies. The pre-test phase confirmed translation accuracy, easy administration, effectiveness in identifying AEs, and relevance of integrating it into hospital risk management. It had a sensitivity of 97.8% and specificity of 74.8%, with a cutoff point of 0.5, an accuracy of 83%, and a positive predictive value of 69.8% and a negative predictive value of 0.98%. Conclusion: The GTT-PT is a reliable, accurate, and valid tool to identify AE, with robust measurement properties.
- Open Access
- 1 December 2019
- Published by FapUNIFESP (SciELO) in Ciencia & Saude Coletiva
- Vol. 24 (12) , 4605-4620
Participação dos pacientes na segurança dos cuidados de saúde: revisão sistemática
Resumo O artigo objetiva identificar as estratégias utilizadas, para participação do paciente na segurança do cuidado de saúde. Revisão sistemática, norteada pelas recomendações do modelo PRISMA, nos bancos de dados: Scopus, WOS e Medline. Limitou-se a busca a estudos realizados entre janeiro de 2001 e julho de 2016, redigidos em português, inglês ou espanhol. Foram incluídos estudos observacionais, descritivos, qualitativos e/ou epidemiológicos, que descrevessem a metodologia de elaboração e/ou aplicação de, pelo menos, uma estratégia de inclusão dos pacientes na melhoria da segurança dos cuidados. A qualidade metodológica dos artigos foi avaliada usando a ferramenta Cochrane. Para analisar os resultados se fez uma análise temática. Após leitura de títulos, resumos e aplicação de critérios de exclusão, 19 artigos foram selecionados. Nestes se identificam estratégias de mobilização dos pacientes para a segurança dos cuidados, estratégias para promover a participação ativa dos pacientes na segurança dos cuidados e estratégias de solicitação de informação ao paciente sobre a segurança dos cuidados. Há na literatura diversas estratégias que promovem a participação do paciente na segurança dos cuidados, que têm formas e métodos concretos de implementação, bem como objetivos distintos para o seu uso.
- 1 December 2019
- Published by FapUNIFESP (SciELO) in Ciencia & Saude Coletiva
- Vol. 24 (12) , 4605-4620
Open AccessParticipação dos pacientes na segurança dos cuidados de saúde: revisão sistemática
Resumo O artigo objetiva identificar as estratégias utilizadas, para participação do paciente na segurança do cuidado de saúde. Revisão sistemática, norteada pelas recomendações do modelo PRISMA, nos bancos de dados: Scopus, WOS e Medline. Limitou-se a busca a estudos realizados entre janeiro de 2001 e julho de 2016, redigidos em português, inglês ou espanhol. Foram incluídos estudos observacionais, descritivos, qualitativos e/ou epidemiológicos, que descrevessem a metodologia de elaboração e/ou aplicação de, pelo menos, uma estratégia de inclusão dos pacientes na melhoria da segurança dos cuidados. A qualidade metodológica dos artigos foi avaliada usando a ferramenta Cochrane. Para analisar os resultados se fez uma análise temática. Após leitura de títulos, resumos e aplicação de critérios de exclusão, 19 artigos foram selecionados. Nestes se identificam estratégias de mobilização dos pacientes para a segurança dos cuidados, estratégias para promover a participação ativa dos pacientes na segurança dos cuidados e estratégias de solicitação de informação ao paciente sobre a segurança dos cuidados. Há na literatura diversas estratégias que promovem a participação do paciente na segurança dos cuidados, que têm formas e métodos concretos de implementação, bem como objetivos distintos para o seu uso.
- Open Access
- 5 November 2018
- Published by IntechOpen
Patient Safety Culture in Portuguese Primary Care: Validation of the Portuguese Version of the Medical Office Survey
Background: Assessing patient safety culture is a strategic priority worldwide, and Portugal is no exception.
- 5 November 2018
- Published by IntechOpen
Open AccessPatient Safety Culture in Portuguese Primary Care: Validation of the Portuguese Version of the Medical Office Survey
Background: Assessing patient safety culture is a strategic priority worldwide, and Portugal is no exception.
- Open Access
- 29 September 2017
- Published by S. Karger AG in Portuguese Journal of Public Health
- Vol. 35 (2) , 69-76
Trigger Tool na Segurança do Doente: Uma Revisão Sistemática de Literatura
Introdução: A elevada incidência de eventos adversos (EA) é uma das situações preocupantes descritas na literatura sendo relacionada diretamente com o aumento dos custos com a prestação de cuidados de saúde e com o aumento do número de dias de internamento. A metodologia Global Trigger Tool (GTT) é relativamente nova mas tem-se mostrado promissora, em contextos internacionais, em ações de rastreio dos EA. Objetivo: Obter um corpo de evidência, reunindo um conjunto de informações acerca da utilização desta metodologia em contexto hospitalar. Metodologia: Trata-se de uma revisão sistemática da literatura, baseada em estudos primários relacionados com esta temática, publicados entre o ano 2009 e 2014. Resultados: O estudo incluiu 8 estudos primários e os resultados evidenciam dados relevantes acerca da utilidade da ferramenta GTT no âmbito hospitalar. Conclusão: A evidência científica mostra que a aplicação do método GTT, como estratégia de monitorização dos EA, é uma ferramenta viável, uma vez que permite acompanhar a implementação de mudanças orientadas para a redução da ocorrência dos EA.
- 29 September 2017
- Published by S. Karger AG in Portuguese Journal of Public Health
- Vol. 35 (2) , 69-76
Open AccessTrigger Tool na Segurança do Doente: Uma Revisão Sistemática de Literatura
Introdução: A elevada incidência de eventos adversos (EA) é uma das situações preocupantes descritas na literatura sendo relacionada diretamente com o aumento dos custos com a prestação de cuidados de saúde e com o aumento do número de dias de internamento. A metodologia Global Trigger Tool (GTT) é relativamente nova mas tem-se mostrado promissora, em contextos internacionais, em ações de rastreio dos EA. Objetivo: Obter um corpo de evidência, reunindo um conjunto de informações acerca da utilização desta metodologia em contexto hospitalar. Metodologia: Trata-se de uma revisão sistemática da literatura, baseada em estudos primários relacionados com esta temática, publicados entre o ano 2009 e 2014. Resultados: O estudo incluiu 8 estudos primários e os resultados evidenciam dados relevantes acerca da utilidade da ferramenta GTT no âmbito hospitalar. Conclusão: A evidência científica mostra que a aplicação do método GTT, como estratégia de monitorização dos EA, é uma ferramenta viável, uma vez que permite acompanhar a implementação de mudanças orientadas para a redução da ocorrência dos EA.
- 25 July 2016
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 15 (4) , 346-353
Radiotherapy couches: is kevlar an obstacle? Attenuation study of three different tabletops
Introduction: Treatment tabletops are usually made of carbon fibre due to its high mechanical strength and rigidity, low specific density, extremely light and regularly considered radiotranslucent. Our clinic acquired a Calypso 4D Localization System where electromagnetic (EM) frequencies to detect implanted transponders in the patient are used. Carbon fibre is an electrical conductive material which interferes with EM frequencies. Therefore, in order to be able to use the Calypso System the carbon fibre tabletop in the treatment room must be replaced. It is our goal to determine the attenuation of the new, non-carbon fibre, tabletop in treatment delivery.Materials and Methods: Measurements were performed using an ionisation chamber inserted in a slab phantom positioned at the isocenter for 6, 10 MV, 6 and 10 flattening filter free (FFF) MV photon beams. These measurements were performed with and without tabletop for 0°, 30° and 60° beam angle for a True Beam STx linac, for 5×5 cm2 and 10×10 cm2 field size beams. The attenuation was calculated for each measurement for each tabletop.Results: At 0° incidence on the Exact IGRT Couch, the measured attenuation for 10×10 cm2 was 2·8 and 2·1% for 6 and 10 MV beams, respectively. For the same field size was measured 3·3 and 2·6% attenuation for 6 and 10 FFF MV beams, respectively. At the same incidence and regarding the other tabletops, the calculated attenuation is lower. For 10×10 cm2 field, there is 2·0, 1·4, 2·1 and 2·6% attenuation for 6, 10 MV, 6 and 10 FFF MV energy beams on the kVueTM Universal Couch. For the KvueTM Calypso® Couch 10×10 cm2 irradiation field, the measurements were 1·6, 1·3, 1·9 and 1·5%, respectively. This tendency is observed for all gantry angles.Discussion: The attenuation outputs were definitely higher for the Varian Exact IGRT Couch when compared with the kVue tabletops. The attenuation measurements for the kVue tabletops were closer to each other. Nevertheless kVueTM Calypso® Varian tabletop showed smaller mean attenuation of the beams than kVueTM Universal Tip Insert for all measurements.Conclusions: There was no loss in treatment quality administration due to beam attenuation in the tabletop when tabletops were exchanged because of Calypso system integration. There is no need to change between kVue tabletops whenever there is a regular treatment or a Calypso System guided treatment.
- 25 July 2016
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 15 (4) , 346-353
Radiotherapy couches: is kevlar an obstacle? Attenuation study of three different tabletops
Introduction: Treatment tabletops are usually made of carbon fibre due to its high mechanical strength and rigidity, low specific density, extremely light and regularly considered radiotranslucent. Our clinic acquired a Calypso 4D Localization System where electromagnetic (EM) frequencies to detect implanted transponders in the patient are used. Carbon fibre is an electrical conductive material which interferes with EM frequencies. Therefore, in order to be able to use the Calypso System the carbon fibre tabletop in the treatment room must be replaced. It is our goal to determine the attenuation of the new, non-carbon fibre, tabletop in treatment delivery.Materials and Methods: Measurements were performed using an ionisation chamber inserted in a slab phantom positioned at the isocenter for 6, 10 MV, 6 and 10 flattening filter free (FFF) MV photon beams. These measurements were performed with and without tabletop for 0°, 30° and 60° beam angle for a True Beam STx linac, for 5×5 cm2 and 10×10 cm2 field size beams. The attenuation was calculated for each measurement for each tabletop.Results: At 0° incidence on the Exact IGRT Couch, the measured attenuation for 10×10 cm2 was 2·8 and 2·1% for 6 and 10 MV beams, respectively. For the same field size was measured 3·3 and 2·6% attenuation for 6 and 10 FFF MV beams, respectively. At the same incidence and regarding the other tabletops, the calculated attenuation is lower. For 10×10 cm2 field, there is 2·0, 1·4, 2·1 and 2·6% attenuation for 6, 10 MV, 6 and 10 FFF MV energy beams on the kVueTM Universal Couch. For the KvueTM Calypso® Couch 10×10 cm2 irradiation field, the measurements were 1·6, 1·3, 1·9 and 1·5%, respectively. This tendency is observed for all gantry angles.Discussion: The attenuation outputs were definitely higher for the Varian Exact IGRT Couch when compared with the kVue tabletops. The attenuation measurements for the kVue tabletops were closer to each other. Nevertheless kVueTM Calypso® Varian tabletop showed smaller mean attenuation of the beams than kVueTM Universal Tip Insert for all measurements.Conclusions: There was no loss in treatment quality administration due to beam attenuation in the tabletop when tabletops were exchanged because of Calypso system integration. There is no need to change between kVue tabletops whenever there is a regular treatment or a Calypso System guided treatment.
- Open Access
- 27 May 2016
- Published by Health Sciences Research Unit: Nursing in Revista de Enfermagem Referência
- Vol. IV Série (Nº 9) , 97-106
An experience with the Global Trigger Tool for the study of adverse events in a medical ward
- 27 May 2016
- Published by Health Sciences Research Unit: Nursing in Revista de Enfermagem Referência
- Vol. IV Série (Nº 9) , 97-106
Open AccessAn experience with the Global Trigger Tool for the study of adverse events in a medical ward
- 5 March 2015
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 14 (2) , 202-207
Calypso’s array attenuation
Introduction: The Calypso 4D Localization System gives the possibility to track the tumour during treatment, with no additional ionising radiation delivered. To monitor the patient continuously an array is positioned above the patient during the treatment. We intend to study, for various gantry angles, the attenuation effect of the array for 6- and 10 MV and flattening filter free (FFF) 6- and FFF 10 MV photon beams.Materials and methods: Measurements were performed using an ion chamber placed in a slab phantom positioned at the linac isocenter for 6 MV, 10 MV, FFF 6 MV and FFF 10 MV photon beams. Measurements were performed with and without array above the phantom for 0°, 10°, 20°, 40° and 50° beam angle for a True Beam STx linac, for 5×5 and 10×10 and 15×15 cm2 field size beams to evaluate the attenuation of the array. A VMAT treatment plan was measured using an ArcCheck with and without the array in the beam path.Results and discussion: Attenuation measured values were up to 3%. Attenuation values were between 1 and 2% with the exception of the 30°–50° gantry angles which were up to 3.3%. The ratio values calculated in the ArcCheck for relative dose and absolute dose 10 were both 1·00.Conclusion: Attenuation of the treatment beam by the Calypso array is within acceptable limits.
- 5 March 2015
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 14 (2) , 202-207
Calypso’s array attenuation
Introduction: The Calypso 4D Localization System gives the possibility to track the tumour during treatment, with no additional ionising radiation delivered. To monitor the patient continuously an array is positioned above the patient during the treatment. We intend to study, for various gantry angles, the attenuation effect of the array for 6- and 10 MV and flattening filter free (FFF) 6- and FFF 10 MV photon beams.Materials and methods: Measurements were performed using an ion chamber placed in a slab phantom positioned at the linac isocenter for 6 MV, 10 MV, FFF 6 MV and FFF 10 MV photon beams. Measurements were performed with and without array above the phantom for 0°, 10°, 20°, 40° and 50° beam angle for a True Beam STx linac, for 5×5 and 10×10 and 15×15 cm2 field size beams to evaluate the attenuation of the array. A VMAT treatment plan was measured using an ArcCheck with and without the array in the beam path.Results and discussion: Attenuation measured values were up to 3%. Attenuation values were between 1 and 2% with the exception of the 30°–50° gantry angles which were up to 3.3%. The ratio values calculated in the ArcCheck for relative dose and absolute dose 10 were both 1·00.Conclusion: Attenuation of the treatment beam by the Calypso array is within acceptable limits.
- 5 August 2014
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 13 (4) , 473-483
Calypso® 4D Localization System: a review
Purpose: Calypso® 4D Localization System is a system based on electromagnetic transponders detection enabling precise 3D localisation and continuous tracking of tumour target. This review intended to provide information in order to (1) show how Calypso® 4D Localization System works, (2) to present advantages and disadvantages of this system, (3) to gather information from several clinical studies and, finally, (4) to refer Calypso® System as a tool in dynamic multileaf collimator studies for target motion compensation.Methods: A structured search was carried out on B-On platform. The key words used in this research were ‘Calypso’, ‘Transponder’, ‘Electromagnetic Localization’, ‘Electromagnetic Tracking’, ‘Target Localization’, ‘Intrafraction Motion’ and ‘DMLC’.Review: Treatment the implanted transponders are excited by an electromagnetic field and resonate back. These frequencies are detected and Calypso® software calculates the position of the transponders. If the movement detected is larger than the limits previously defined, irradiation can be stopped. The system has been proven to be submillimetre accurate.Discussion: Calypso® System has been presented as an accurate tool in prostate radiotherapy treatments. The application of this system to other clinical sites is being developed.Conclusion: The Calypso® System allows real-time localisation and monitoring of the target, without additional ionising radiation administration. It has been a very useful tool in prostate cancer treatment.
- 5 August 2014
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 13 (4) , 473-483
Calypso® 4D Localization System: a review
Purpose: Calypso® 4D Localization System is a system based on electromagnetic transponders detection enabling precise 3D localisation and continuous tracking of tumour target. This review intended to provide information in order to (1) show how Calypso® 4D Localization System works, (2) to present advantages and disadvantages of this system, (3) to gather information from several clinical studies and, finally, (4) to refer Calypso® System as a tool in dynamic multileaf collimator studies for target motion compensation.Methods: A structured search was carried out on B-On platform. The key words used in this research were ‘Calypso’, ‘Transponder’, ‘Electromagnetic Localization’, ‘Electromagnetic Tracking’, ‘Target Localization’, ‘Intrafraction Motion’ and ‘DMLC’.Review: Treatment the implanted transponders are excited by an electromagnetic field and resonate back. These frequencies are detected and Calypso® software calculates the position of the transponders. If the movement detected is larger than the limits previously defined, irradiation can be stopped. The system has been proven to be submillimetre accurate.Discussion: Calypso® System has been presented as an accurate tool in prostate radiotherapy treatments. The application of this system to other clinical sites is being developed.Conclusion: The Calypso® System allows real-time localisation and monitoring of the target, without additional ionising radiation administration. It has been a very useful tool in prostate cancer treatment.