Ingemar Fredriksson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ingemar Fredriksson has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Marcus Larsson
Department of Biomedical Engineering, Linköping University, Linköping, Sweden
36 shared publications Tomas Strömberg
Linköping University, Department of Biomedical Engineering, Linköping, Sweden
24 shared publications- Tomas Strömberg
Department of Biomedical Engineering, Linköping University, Linköping, Sweden
13 shared publications - Hanna Jonasson
Department of Biomedical Engineering, Linköping University, Linköping, Sweden
7 shared publications - Martin Hultman
Department of Biomedical Engineering, Linköping University, Linköping, Sweden; Perimed AB, Datavägen 9A, Järfälla, Stockholm, Sweden
7 shared publications - Fredrik Iredahl
Wallenberg Center for Molecular Medicine, Linköping University, Linköping, Sweden
4 shared publications
Latest Publications
- Open Access
- 13 July 2026
- Published by Elsevier in Microvascular Research
- Vol. 167, 104987
Cutaneous microvascular reactivity in the foot evaluated by optical multimodal pointwise and imaging techniques and different stimuli
- 13 July 2026
- Published by Elsevier in Microvascular Research
- Vol. 167, 104987
Open AccessCutaneous microvascular reactivity in the foot evaluated by optical multimodal pointwise and imaging techniques and different stimuli
- 7 July 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 331 (2) , H552-H561
Microcirculatory Perfusion Pulsatility in Foot Sole Skin is a Marker of Treatment Response in Chronic Limb Threatening Ischemia
The aim of this study was to evaluate microcirculatory perfusion and oxygen saturation in the foot sole of patients with chronic limb-threatening ischemia (CLTI) before and after endovascular intervention using a novel multimodal imaging system. This single-centre observational cohort study included patients with CLTI due to infrainguinal arterial disease, scheduled for endovascular intervention over an 11-month period. Inclusion required a CLTI diagnosis and at least one of: hemodynamic transcutaneous partial pressure of oxygen (TcPO 2 ) <30 mmHg, toe pressure (TP) <30 mmHg, ankle-brachial index (ABI) <0.4, or ankle pressure <50 mmHg. For patients with diabetes, the TP threshold was adjusted to <50 mmHg. Measurements were performed preoperatively, early postoperatively, and at 1-month follow-up using a multimodal optical system combining multi-exposure laser speckle contrast imaging and multispectral imaging to assess real-time microvascular perfusion and oxygen saturation. Conventional measures (toe pressure, TcPO₂, ABI) were used for comparison. Twenty-five patients were included: 20 successfully revascularized and five serving as a comparison group. Early postoperative results in the revascularized group showed significant increases in TcPO₂ (p=0.004) and – in the combined region of interest – microcirculatory median perfusion (p=0.004), perfusion pulsatility (p<0.001), and oxygen saturation (p=0.01). At 1 month, TcPO₂ (p=0.006), TP (p=0.002) and perfusion pulsatility (p=0.002) remained significantly elevated, whereas median perfusion (p=0.642) and oxygen saturation (p=0.397) returned to baseline levels. No significant changes were observed in the comparison group. The multimodal imaging system detected early microcirculatory improvements after endovascular intervention. While perfusion and oxygen saturation average levels increased early but transiently, sustained increases in perfusion pulsatility suggest it being a marker of improved and lasting microvascular recovery.
- 7 July 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 331 (2) , H552-H561
Microcirculatory Perfusion Pulsatility in Foot Sole Skin is a Marker of Treatment Response in Chronic Limb Threatening Ischemia
The aim of this study was to evaluate microcirculatory perfusion and oxygen saturation in the foot sole of patients with chronic limb-threatening ischemia (CLTI) before and after endovascular intervention using a novel multimodal imaging system. This single-centre observational cohort study included patients with CLTI due to infrainguinal arterial disease, scheduled for endovascular intervention over an 11-month period. Inclusion required a CLTI diagnosis and at least one of: hemodynamic transcutaneous partial pressure of oxygen (TcPO 2 ) <30 mmHg, toe pressure (TP) <30 mmHg, ankle-brachial index (ABI) <0.4, or ankle pressure <50 mmHg. For patients with diabetes, the TP threshold was adjusted to <50 mmHg. Measurements were performed preoperatively, early postoperatively, and at 1-month follow-up using a multimodal optical system combining multi-exposure laser speckle contrast imaging and multispectral imaging to assess real-time microvascular perfusion and oxygen saturation. Conventional measures (toe pressure, TcPO₂, ABI) were used for comparison. Twenty-five patients were included: 20 successfully revascularized and five serving as a comparison group. Early postoperative results in the revascularized group showed significant increases in TcPO₂ (p=0.004) and – in the combined region of interest – microcirculatory median perfusion (p=0.004), perfusion pulsatility (p<0.001), and oxygen saturation (p=0.01). At 1 month, TcPO₂ (p=0.006), TP (p=0.002) and perfusion pulsatility (p=0.002) remained significantly elevated, whereas median perfusion (p=0.642) and oxygen saturation (p=0.397) returned to baseline levels. No significant changes were observed in the comparison group. The multimodal imaging system detected early microcirculatory improvements after endovascular intervention. While perfusion and oxygen saturation average levels increased early but transiently, sustained increases in perfusion pulsatility suggest it being a marker of improved and lasting microvascular recovery.
- 1 December 2025
- Published by Wolters Kluwer Health in Stroke
- Vol. 56 (12) , 3484-3499
SIN-1 Improves Cerebral Blood Flow and Reduces Deviation From Brain Homeostasis During Ischemia and Reperfusion in Rats
BACKGROUND: Overall, 75% of patients with acute stroke have elevated mean arterial pressure (MAP). In randomized stroke trials, the indirect NO donor glyceryl trinitrate lowered MAP but improved neither regional cerebral blood flow (rCBF) nor functional outcomes. One probable reason is that the microcirculation cannot bioactivate glyceryl trinitrate. In contrast, the direct NO donor 3-morpholinosydnonimine (SIN-1), not requiring bioactivation, should also release NO in small vessels, where it supports eNOS (endothelial NO synthase)–derived NO in maintaining rCBF in the hypotensive portion of Lassen autoregulatory curve. In a meta-analysis, SIN-1 reduced infarct volume in ischemia models, but the effects of SIN-1 on early pathophysiology are unknown. METHODS: Here, we investigated SIN-1 during a 60-minute bilateral common carotid artery occlusion and reperfusion in forty-eight 12- to 14-week-old Wistar-Kyoto rat (WKY) controls and 48 stroke-prone spontaneously hypertensive rats. We calculated the difference between the median values of each variable in the last 5 minutes of bilateral common carotid artery occlusion and baseline and compared them between treatment (SIN-1/control) and strain (stroke-prone spontaneously hypertensive rat/WKY) using 2-way ANOVA. We proceeded in the same way regarding reperfusion. RESULTS: Strain×intervention interaction was only found for MAP during bilateral common carotid artery occlusion. SIN-1 lowered MAP within stroke-prone spontaneously hypertensive rats ( P P P =0.038). Across stroke-prone spontaneously hypertensive rat and WKY, SIN-1 increased rCBF ( P P =0.002), lowered extracellular potassium concentration ( P =0.009) and area under the curve of potassium ( P =0.025), and reduced the direct current–amplitude ( P =0.028) and cumulative direct current–shift duration ( P =0.001), consistent with milder ischemia and less severe spreading depolarization load in SIN-1–treated animals. During reperfusion, SIN-1 lowered MAP ( P P =0.002), increased rCBF ( P P P =0.008) and direct current potential ( P =0.022) in both strains, consistent with less no-reflow and better recovery in SIN-1–treated animals. CONCLUSIONS: SIN-1 emerges as a promising antihypertensive in acute stroke as it paradoxically increases rCBF in ischemic tissue and reduces no-reflow.
- 1 December 2025
- Published by Wolters Kluwer Health in Stroke
- Vol. 56 (12) , 3484-3499
SIN-1 Improves Cerebral Blood Flow and Reduces Deviation From Brain Homeostasis During Ischemia and Reperfusion in Rats
BACKGROUND: Overall, 75% of patients with acute stroke have elevated mean arterial pressure (MAP). In randomized stroke trials, the indirect NO donor glyceryl trinitrate lowered MAP but improved neither regional cerebral blood flow (rCBF) nor functional outcomes. One probable reason is that the microcirculation cannot bioactivate glyceryl trinitrate. In contrast, the direct NO donor 3-morpholinosydnonimine (SIN-1), not requiring bioactivation, should also release NO in small vessels, where it supports eNOS (endothelial NO synthase)–derived NO in maintaining rCBF in the hypotensive portion of Lassen autoregulatory curve. In a meta-analysis, SIN-1 reduced infarct volume in ischemia models, but the effects of SIN-1 on early pathophysiology are unknown. METHODS: Here, we investigated SIN-1 during a 60-minute bilateral common carotid artery occlusion and reperfusion in forty-eight 12- to 14-week-old Wistar-Kyoto rat (WKY) controls and 48 stroke-prone spontaneously hypertensive rats. We calculated the difference between the median values of each variable in the last 5 minutes of bilateral common carotid artery occlusion and baseline and compared them between treatment (SIN-1/control) and strain (stroke-prone spontaneously hypertensive rat/WKY) using 2-way ANOVA. We proceeded in the same way regarding reperfusion. RESULTS: Strain×intervention interaction was only found for MAP during bilateral common carotid artery occlusion. SIN-1 lowered MAP within stroke-prone spontaneously hypertensive rats ( P P P =0.038). Across stroke-prone spontaneously hypertensive rat and WKY, SIN-1 increased rCBF ( P P =0.002), lowered extracellular potassium concentration ( P =0.009) and area under the curve of potassium ( P =0.025), and reduced the direct current–amplitude ( P =0.028) and cumulative direct current–shift duration ( P =0.001), consistent with milder ischemia and less severe spreading depolarization load in SIN-1–treated animals. During reperfusion, SIN-1 lowered MAP ( P P =0.002), increased rCBF ( P P P =0.008) and direct current potential ( P =0.022) in both strains, consistent with less no-reflow and better recovery in SIN-1–treated animals. CONCLUSIONS: SIN-1 emerges as a promising antihypertensive in acute stroke as it paradoxically increases rCBF in ischemic tissue and reduces no-reflow.
- Open Access
- 14 May 2025
- Published by Elsevier in Microvascular Research
- Vol. 160, 104819
Day-to-day variability in cutaneous microcirculation measured with multi-exposure laser speckle contrast imaging and multispectral imaging
- 14 May 2025
- Published by Elsevier in Microvascular Research
- Vol. 160, 104819
Open AccessDay-to-day variability in cutaneous microcirculation measured with multi-exposure laser speckle contrast imaging and multispectral imaging
- Open Access
- 19 January 2025
- Published by Elsevier in Microvascular Research
- Vol. 159, 104783
Sex and age-related day-to-day variability in the skin microcirculation during post-occlusive reactive hyperemia
- 19 January 2025
- Published by Elsevier in Microvascular Research
- Vol. 159, 104783
Open AccessSex and age-related day-to-day variability in the skin microcirculation during post-occlusive reactive hyperemia
- Open Access
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33304-18
Artificial neural networks trained on simulated multispectral data for real-time imaging of skin microcirculatory blood oxygen saturation
Blood oxygen saturation () is defined as the fraction of oxygen-saturated hemoglobin. Arterial can be monitored through pulse oximetry (PO) and provides information on how well the lungs oxygenate blood.1 Peripherally, the lack of significant blood pulsations makes PO insensitive to microvascular . Instead, transcutaneous oximetry () can be used to measure the locally available free oxygen that has diffused from the microvascular blood.2 The is a technique that only measures slow changes in one point. Spectroscopic optical techniques, including near-infrared spectroscopy3 (NIRS) and diffuse reflectance spectroscopy4,5 (DRS), allow for the fast and direct assessment of local levels in the microcirculation and smaller vessels. Due to a superficial sampling depth for DRS in the visible wavelength range, compared with NIRS, DRS mainly monitors capillary and upper dermis microvascular vessels, whereas NIRS includes deeper and larger vessels when measuring skin tissue.6- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33304-18
Open AccessArtificial neural networks trained on simulated multispectral data for real-time imaging of skin microcirculatory blood oxygen saturation
Blood oxygen saturation () is defined as the fraction of oxygen-saturated hemoglobin. Arterial can be monitored through pulse oximetry (PO) and provides information on how well the lungs oxygenate blood.1 Peripherally, the lack of significant blood pulsations makes PO insensitive to microvascular . Instead, transcutaneous oximetry () can be used to measure the locally available free oxygen that has diffused from the microvascular blood.2 The is a technique that only measures slow changes in one point. Spectroscopic optical techniques, including near-infrared spectroscopy3 (NIRS) and diffuse reflectance spectroscopy4,5 (DRS), allow for the fast and direct assessment of local levels in the microcirculation and smaller vessels. Due to a superficial sampling depth for DRS in the visible wavelength range, compared with NIRS, DRS mainly monitors capillary and upper dermis microvascular vessels, whereas NIRS includes deeper and larger vessels when measuring skin tissue.6 - Open Access
- 30 January 2024
- Published by Elsevier in Microvascular Research
- Vol. 153, 104666
Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols
- 30 January 2024
- Published by Elsevier in Microvascular Research
- Vol. 153, 104666
Open AccessReproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols
- Open Access
- 1 November 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (11) , 115001-14
Absorption and reduced scattering coefficients in epidermis and dermis from a Swedish cohort study
Knowing the optical properties of tissue is of central importance in accurately modeling light propagation.1 These optical properties describe photon scattering and absorption in tissue and can be used to simulate the amount of backscattered light from an illuminated tissue surface using diffusion theory or the Monte Carlo technique. In in vivo bio-optical applications, it is common to design instruments that make use of inverse modeling for estimating these properties from spatially, temporarily, and/or spectrally resolved diffusely backscattered light intensities. One such instrument is the PeriFlux 6000 EPOS (enhanced perfusion and oxygen saturation) system in which inverse Monte Carlo is used to analyze spatially and spectrally resolved data to estimate parameters of direct clinical values including hemoglobin tissue fraction and oxygen saturation.2 – 4
- 1 November 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (11) , 115001-14
Open AccessAbsorption and reduced scattering coefficients in epidermis and dermis from a Swedish cohort study
Knowing the optical properties of tissue is of central importance in accurately modeling light propagation.1 These optical properties describe photon scattering and absorption in tissue and can be used to simulate the amount of backscattered light from an illuminated tissue surface using diffusion theory or the Monte Carlo technique. In in vivo bio-optical applications, it is common to design instruments that make use of inverse modeling for estimating these properties from spatially, temporarily, and/or spectrally resolved diffusely backscattered light intensities. One such instrument is the PeriFlux 6000 EPOS (enhanced perfusion and oxygen saturation) system in which inverse Monte Carlo is used to analyze spatially and spectrally resolved data to estimate parameters of direct clinical values including hemoglobin tissue fraction and oxygen saturation.2 – 4
- Open Access
- 15 May 2023
- Published by Elsevier in Microvascular Research
- Vol. 148, 104547
Workload and sex effects in comprehensive assessment of cutaneous microcirculation
- 15 May 2023
- Published by Elsevier in Microvascular Research
- Vol. 148, 104547
Open AccessWorkload and sex effects in comprehensive assessment of cutaneous microcirculation
- 14 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12352, 37-62
Absorption and reduced scattering coefficients in epidermis and dermis from a Swedish cohort study
We present in vivo optical properties of skin tissue assessed using spatially resolved diffuse reflectance spectroscopy. Data was collected in a sub-study of the Swedish CArdioPulmonary bioImage Study (SCAPIS). Measurements were performed on 3,809 subjects, 50-65 years, on the volar side of the forearm with the PeriFlux 6000 EPOS system. The analysis consisted of an inverse Monte Carlo method where modeled spectra were non-linearly fitted to measured diffuse reflectance spectra at 0.4 and 1.2-mm source-detector fiber separations, respectively, between 475 and 850 nm. The model consisted of one epidermis layer with adaptable thickness and absorption caused by melanin, and two dermis layers. The upper dermis had a fixed thickness of 0.2 mm and the lower an infinite thickness. The absorption in the dermis layers depended on varying amounts of hemoglobin and its oxygen saturation. The reduced scattering coefficient, with three adaptable parameters, was equal in all layers in the model. Absorption coefficient in epidermis times epidermis thickness, reflecting the total amount of melanin, was 0.19±0.16 [-] at 570 nm with a significant difference between winter (0.12±0.10) and summer (0.26±0.19). Melanin absorption implies an average of 3.9% tissue fraction of melanosomes in epidermis. Absorption coefficient at the 570 nm isosbestic point was 0.19±0.11 mm-1 in the upper dermis layer and 0.10±0.05 mm-1 in the lower. The reduced scattering coefficient was 2.3±0.5 mm-1 at 570 nm. Average sampling depth for all wavelengths and both separations was 0.43±0.03 mm.
- 14 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12352, 37-62
Absorption and reduced scattering coefficients in epidermis and dermis from a Swedish cohort study
We present in vivo optical properties of skin tissue assessed using spatially resolved diffuse reflectance spectroscopy. Data was collected in a sub-study of the Swedish CArdioPulmonary bioImage Study (SCAPIS). Measurements were performed on 3,809 subjects, 50-65 years, on the volar side of the forearm with the PeriFlux 6000 EPOS system. The analysis consisted of an inverse Monte Carlo method where modeled spectra were non-linearly fitted to measured diffuse reflectance spectra at 0.4 and 1.2-mm source-detector fiber separations, respectively, between 475 and 850 nm. The model consisted of one epidermis layer with adaptable thickness and absorption caused by melanin, and two dermis layers. The upper dermis had a fixed thickness of 0.2 mm and the lower an infinite thickness. The absorption in the dermis layers depended on varying amounts of hemoglobin and its oxygen saturation. The reduced scattering coefficient, with three adaptable parameters, was equal in all layers in the model. Absorption coefficient in epidermis times epidermis thickness, reflecting the total amount of melanin, was 0.19±0.16 [-] at 570 nm with a significant difference between winter (0.12±0.10) and summer (0.26±0.19). Melanin absorption implies an average of 3.9% tissue fraction of melanosomes in epidermis. Absorption coefficient at the 570 nm isosbestic point was 0.19±0.11 mm-1 in the upper dermis layer and 0.10±0.05 mm-1 in the lower. The reduced scattering coefficient was 2.3±0.5 mm-1 at 570 nm. Average sampling depth for all wavelengths and both separations was 0.43±0.03 mm.