Yuan Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuan Ren has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Zi Qiang Zhu
University of Sheffield
4 shared publications - Nattapong Pothi
University of Phayao
2 shared publications - Atheer H. Abosh
Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield, U.K.
1 shared publication - Heyun Lin
Southeast University
1 shared publication - Hui Yang
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication - James E. Green
Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield, U.K.
1 shared publication
Latest Publications
- 24 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 6 (3) , 1157-1166
A Magnetization State Initialization Control Scheme for Variable Flux Memory Machines Without Requiring Position Sensor Information
Variable flux memory machines (VFMMs) normally suffer from excessively low initial magnetization state (MS), which will cause a large starting current or even start-up failure. This paper proposes an MS initialization control scheme for VFMMs equipped with incremental encoders, in which the required rotor position is estimated by injecting high-frequency square-wave voltage. Based on the estimated initial rotor position, the MS initialization can be accurately and smoothly achieved by applying a d-axis current pulse. The general framework of the proposed scheme is demonstrated firstly. The voltage pulse magnitude determination of the bipolar injection method is then particularly discussed to realize the polarity detection within a full flux regulation range. The implementation of the d-axis current pulse injection method for the MS initialization based on the estimated rotor position is subsequently introduced. Finally, the feasibility and effectiveness of the proposed MS initialization control scheme are experimentally verified on a manufactured VFMM prototype.
- 24 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 6 (3) , 1157-1166
A Magnetization State Initialization Control Scheme for Variable Flux Memory Machines Without Requiring Position Sensor Information
Variable flux memory machines (VFMMs) normally suffer from excessively low initial magnetization state (MS), which will cause a large starting current or even start-up failure. This paper proposes an MS initialization control scheme for VFMMs equipped with incremental encoders, in which the required rotor position is estimated by injecting high-frequency square-wave voltage. Based on the estimated initial rotor position, the MS initialization can be accurately and smoothly achieved by applying a d-axis current pulse. The general framework of the proposed scheme is demonstrated firstly. The voltage pulse magnitude determination of the bipolar injection method is then particularly discussed to realize the polarity detection within a full flux regulation range. The implementation of the d-axis current pulse injection method for the MS initialization based on the estimated rotor position is subsequently introduced. Finally, the feasibility and effectiveness of the proposed MS initialization control scheme are experimentally verified on a manufactured VFMM prototype.
- 29 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 5843-5853
Improved Duty-Ratio-Based Direct Torque Control for Dual Three-Phase Permanent Magnet Synchronous Machine Drives
This article investigates the duty-ratio-based direct torque control strategies for dual three-phase permanent magnet synchronous machine (PMSM) drives. The classical switching-table-based direct torque control (ST-DTC) for the dual three-phase drives usually suffers from significant harmonic currents and a large torque ripple. To reduce the harmonic currents, 12 combined voltage vectors are generated and employed as active vectors. Then, the duty-ratio-based ST-DTC is introduced to reduce the torque ripple. Considering that the typical duty-ratio-based ST-DTC exhibits the drawbacks of machine parameter dependent and a certain degree of failure rate in the duty ratio regulation, a simple and effective method taking into account the effect of the machine speed is employed to obtain the duty ratio. Afterward, to prevent the issue of the inverter thermal imbalance caused by using only one type of zero vectors, two types of zero vectors are employed in the switching sequences. With the proposed method, not only the harmonic currents have been suppressed, but also the torque ripple can be considerably reduced, while the merits of the classical ST-DTC such as simple structure and excellent dynamic performance are preserved. The experimental results validate the effectiveness of the proposed strategy.
- 29 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 5843-5853
Improved Duty-Ratio-Based Direct Torque Control for Dual Three-Phase Permanent Magnet Synchronous Machine Drives
This article investigates the duty-ratio-based direct torque control strategies for dual three-phase permanent magnet synchronous machine (PMSM) drives. The classical switching-table-based direct torque control (ST-DTC) for the dual three-phase drives usually suffers from significant harmonic currents and a large torque ripple. To reduce the harmonic currents, 12 combined voltage vectors are generated and employed as active vectors. Then, the duty-ratio-based ST-DTC is introduced to reduce the torque ripple. Considering that the typical duty-ratio-based ST-DTC exhibits the drawbacks of machine parameter dependent and a certain degree of failure rate in the duty ratio regulation, a simple and effective method taking into account the effect of the machine speed is employed to obtain the duty ratio. Afterward, to prevent the issue of the inverter thermal imbalance caused by using only one type of zero vectors, two types of zero vectors are employed in the switching sequences. With the proposed method, not only the harmonic currents have been suppressed, but also the torque ripple can be considerably reduced, while the merits of the classical ST-DTC such as simple structure and excellent dynamic performance are preserved. The experimental results validate the effectiveness of the proposed strategy.
- 4 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (4) , 3598-3606
Uncontrolled Generator Fault Protection of Novel Hybrid-Excited Doubly Salient Synchronous Machines With Field Excitation Current Control
In the safe-critical applications such as electric/hybrid electric vehicles, reliability of the machine drive system is vital. Among the various machine fault types, the uncontrolled generator fault (UCGF) at high speed is one of the most serious faults that could damage the machine drive system. In this paper, the fault protection capability of a novel hybrid-excited doubly salient synchronous machine is examined to illustrate its great capability to prevent the dangerous overvoltage issue from the UCGF. PM flux of the novel hybrid-excited doubly salient synchronous machine is inherently short-circuited when the field excitation current is not fed into the excitation windings. Therefore, when the UCGF is detected in the high speed region, the DC-link overvoltage issue can be effectively reduced by forcing the field excitation current to zero. Since only the field excitation current is utilized to protect the machine and power inverter from the UCGF, it is easy to implement and the concept of proposed control strategy can also be applied to other hybrid-excited machines. Finally, the proposed control strategy is verified by both simulation and experimental results on the hybrid-excited doubly salient synchronous machine.
- 4 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (4) , 3598-3606
Uncontrolled Generator Fault Protection of Novel Hybrid-Excited Doubly Salient Synchronous Machines With Field Excitation Current Control
In the safe-critical applications such as electric/hybrid electric vehicles, reliability of the machine drive system is vital. Among the various machine fault types, the uncontrolled generator fault (UCGF) at high speed is one of the most serious faults that could damage the machine drive system. In this paper, the fault protection capability of a novel hybrid-excited doubly salient synchronous machine is examined to illustrate its great capability to prevent the dangerous overvoltage issue from the UCGF. PM flux of the novel hybrid-excited doubly salient synchronous machine is inherently short-circuited when the field excitation current is not fed into the excitation windings. Therefore, when the UCGF is detected in the high speed region, the DC-link overvoltage issue can be effectively reduced by forcing the field excitation current to zero. Since only the field excitation current is utilized to protect the machine and power inverter from the UCGF, it is easy to implement and the concept of proposed control strategy can also be applied to other hybrid-excited machines. Finally, the proposed control strategy is verified by both simulation and experimental results on the hybrid-excited doubly salient synchronous machine.
- Open Access
- 4 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (4) , 3589-3597
Comparison of Flux-Weakening Control Strategies of Novel Hybrid-Excited Doubly Salient Synchronous Machines
For hybrid-excited doubly salient synchronous machine, both the field excitation current and the d-axis current can be utilized to adjust the flux-linkage, which provides more flexible control parameters for flux-weakening operation. In this paper, three flux-weakening control methods, i.e. utilizing field excitation current alone (Method-I), utilizing armature current alone (Method-II), and optimal method (Method-III), are proposed and compared. All three methods can achieve similar torque performance in the constant-torque region. In the flux-weakening region, Method-I exhibits low torque and limited operating speed range. The operating speed range can be further extended by Method-II and Method-III. In addition, Method-III can provide a higher efficiency in flux-weakening region than Method-II since the copper loss of field winding can be decreased in proportion to the reduction of field excitation current. Those flux-weakening control methods are verified by experimental results.
- 4 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (4) , 3589-3597
Open AccessComparison of Flux-Weakening Control Strategies of Novel Hybrid-Excited Doubly Salient Synchronous Machines
For hybrid-excited doubly salient synchronous machine, both the field excitation current and the d-axis current can be utilized to adjust the flux-linkage, which provides more flexible control parameters for flux-weakening operation. In this paper, three flux-weakening control methods, i.e. utilizing field excitation current alone (Method-I), utilizing armature current alone (Method-II), and optimal method (Method-III), are proposed and compared. All three methods can achieve similar torque performance in the constant-torque region. In the flux-weakening region, Method-I exhibits low torque and limited operating speed range. The operating speed range can be further extended by Method-II and Method-III. In addition, Method-III can provide a higher efficiency in flux-weakening region than Method-II since the copper loss of field winding can be decreased in proportion to the reduction of field excitation current. Those flux-weakening control methods are verified by experimental results.
- 16 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (2) , 1740-1749
Cascaded Direct Torque Control of Unbalanced PMSM With Low Torque and Flux Ripples
During operation or manufacturing, the electrical machines are often exposed to parasitic impedance in the phases, causing unbalanced three-phase currents and increased torque and flux ripples. To mitigate the undesired torque and flux ripples, this paper presents a modified cascaded direct torque control strategy for three-phase PMSMs, having asymmetric phase impedances. The proposed method aims to generate the positive and negative reference voltage vectors by extracting the sequential components of the stator flux and current in the stationary αβ frame. Then, these two vectors are combined to produce the modified reference voltage vector for space vector modulation. Moreover, for further torque ripple suppression, a standard proportional-integral regulator has been enhanced by a resonant controller tuning at twice of the fundamental frequency. Various experimental results verify the feasibility of the proposed strategy under dynamic and steady-state conditions.
- 16 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (2) , 1740-1749
Cascaded Direct Torque Control of Unbalanced PMSM With Low Torque and Flux Ripples
During operation or manufacturing, the electrical machines are often exposed to parasitic impedance in the phases, causing unbalanced three-phase currents and increased torque and flux ripples. To mitigate the undesired torque and flux ripples, this paper presents a modified cascaded direct torque control strategy for three-phase PMSMs, having asymmetric phase impedances. The proposed method aims to generate the positive and negative reference voltage vectors by extracting the sequential components of the stator flux and current in the stationary αβ frame. Then, these two vectors are combined to produce the modified reference voltage vector for space vector modulation. Moreover, for further torque ripple suppression, a standard proportional-integral regulator has been enhanced by a resonant controller tuning at twice of the fundamental frequency. Various experimental results verify the feasibility of the proposed strategy under dynamic and steady-state conditions.
- 1 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (21571473) , 474-477
Study on Grey Relation Analysis Based on Entropy Method in Evaluation of Logistics Center Location
Based on establishing an evaluation index system of logistics center location, an integrated decision model is constructed by using the entropy method and grey related analysis. The weights of the evaluation indexes are defined by the entropy method. The quantitative process and comparison of the qualitative information are made by grey relation Analysis. This will reduce the subjective elements and improve the accuracy of the evaluation conclusion. A new method for the evaluation of logistics center location is set up. And an example is applied.
- 1 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (21571473) , 474-477
Study on Grey Relation Analysis Based on Entropy Method in Evaluation of Logistics Center Location
Based on establishing an evaluation index system of logistics center location, an integrated decision model is constructed by using the entropy method and grey related analysis. The weights of the evaluation indexes are defined by the entropy method. The quantitative process and comparison of the qualitative information are made by grey relation Analysis. This will reduce the subjective elements and improve the accuracy of the evaluation conclusion. A new method for the evaluation of logistics center location is set up. And an example is applied.