Yuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuan Wang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Nan Xiao
Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
3 shared publications - Shuxiang Guo
Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China
2 shared publications Youxiang Li
Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, No.6 Tiantan Xili, Chongwen District, Beijing, China
2 shared publicationsYuhua Jiang
Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, No.6 Tiantan Xili, Chongwen District, Beijing, China
2 shared publications- Dongmei Li
Key Laboratory of Quantum Precision Measurement of Zhejiang Province, Center for Optics & Optoelectronics Research, Collaborative Innovation Center for Information Technology in Biological and Medical Physics, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
1 shared publication - Duli Yu
College of Information Science and Technology, Beijing University of Chemical and Technology, Beijing, China
1 shared publication
Latest Publications
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 876-879
Microfluidic Device Integrated with Deformable 3D Agpdms Beam For Blood Coagulation Monitoring
This work for the first time demonstrates blood coagulation measurement by electrical resistance sensing of a three-dimensional (3D) elastic beam deformed by flowing blood undergoing coagulation process, as enabled by a novel microfluidic strain sensor with 3D AgPDMS beam fabricated using low-cost molding process. The chip has been showcased here for the electric current change when the chip is infused with glycerol solutions at different flow rates and varied viscosities by adjusting glycerol concentrations in water. Primary testing on blood coagulation using the chip are conducted by measuring the current change when injecting the blood at increased time intervals post initiation of coagulation.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 876-879
Microfluidic Device Integrated with Deformable 3D Agpdms Beam For Blood Coagulation Monitoring
This work for the first time demonstrates blood coagulation measurement by electrical resistance sensing of a three-dimensional (3D) elastic beam deformed by flowing blood undergoing coagulation process, as enabled by a novel microfluidic strain sensor with 3D AgPDMS beam fabricated using low-cost molding process. The chip has been showcased here for the electric current change when the chip is infused with glycerol solutions at different flow rates and varied viscosities by adjusting glycerol concentrations in water. Primary testing on blood coagulation using the chip are conducted by measuring the current change when injecting the blood at increased time intervals post initiation of coagulation.
- 27 October 2018
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 39 (5) , 653-664
Surgeons’ Operation Skill-Based Control Strategy and Preliminary Evaluation for a Vascular Interventional Surgical Robot
- 27 October 2018
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 39 (5) , 653-664
Surgeons’ Operation Skill-Based Control Strategy and Preliminary Evaluation for a Vascular Interventional Surgical Robot
- 13 April 2018
- Published by Springer Nature in Biomedical Microdevices
- Vol. 20 (2) , 37
Study on real-time force feedback for a master–slave interventional surgical robotic system
In robot-assisted catheterization, haptic feedback is important, but is currently lacking. In addition, conventional interventional surgical robotic systems typically employ a master–slave architecture with an open-loop force feedback, which results in inaccurate control. We develop herein a novel real-time master–slave (RTMS) interventional surgical robotic system with a closed-loop force feedback that allows a surgeon to sense the true force during remote operation, provide adequate haptic feedback, and improve control accuracy in robot-assisted catheterization. As part of this system, we also design a unique master control handle that measures the true force felt by a surgeon, providing the basis for the closed-loop control of the entire system. We use theoretical and empirical methods to demonstrate that the proposed RTMS system provides a surgeon (using the master control handle) with a more accurate and realistic force sensation, which subsequently improves the precision of the master–slave manipulation. The experimental results show a substantial increase in the control accuracy of the force feedback and an increase in operational efficiency during surgery.
- 13 April 2018
- Published by Springer Nature in Biomedical Microdevices
- Vol. 20 (2) , 37
Study on real-time force feedback for a master–slave interventional surgical robotic system
In robot-assisted catheterization, haptic feedback is important, but is currently lacking. In addition, conventional interventional surgical robotic systems typically employ a master–slave architecture with an open-loop force feedback, which results in inaccurate control. We develop herein a novel real-time master–slave (RTMS) interventional surgical robotic system with a closed-loop force feedback that allows a surgeon to sense the true force during remote operation, provide adequate haptic feedback, and improve control accuracy in robot-assisted catheterization. As part of this system, we also design a unique master control handle that measures the true force felt by a surgeon, providing the basis for the closed-loop control of the entire system. We use theoretical and empirical methods to demonstrate that the proposed RTMS system provides a surgeon (using the master control handle) with a more accurate and realistic force sensation, which subsequently improves the precision of the master–slave manipulation. The experimental results show a substantial increase in the control accuracy of the force feedback and an increase in operational efficiency during surgery.
- 3 February 2018
- Published by Springer Nature in Microsystem Technologies
- Vol. 24 (8) , 3467-3477
Online measuring and evaluation of guidewire inserting resistance for robotic interventional surgery systems
- 3 February 2018
- Published by Springer Nature in Microsystem Technologies
- Vol. 24 (8) , 3467-3477
Online measuring and evaluation of guidewire inserting resistance for robotic interventional surgery systems
- 9 June 2015
- Published by Wiley in Rare Metals
- Vol. 40 (3) , 714-719
Microstructure, wetting property of Sn–Ag–Cu–Bi– x Ce solder and IMC growth at solder/Cu interface during thermal cycling
The effects of adding small amounts of cerium (Ce) to Sn–3.3Ag–0.2Cu–4.7Bi solder on microstructure, wettability characteristic, interfacial morphology and the growth of interfacial intermetallic compound (IMC) during thermal cycling were investigated by optical microscopy (OM), scanning electron microscopy (SEM) and solderability tester. It is found that the β‐Sn phase, Ag 3 Sn phase and Cu 6 Sn 5 phase in the solder are refined and the wetting force increases. Ce is an active element; it more easily accumulates at the solder/flux interface in the molten state, which decreases the interfacial surface energy and reduces the driving force for IMC formation on Cu substrate; therefore, the thickness of IMC at the solder/Cu interface decreases when appropriate Ce was added into the solder. Moreover, the Ce‐containing solders have lower growth rate of interfacial IMC than solders without Ce during the thermal cycling between −55 and 125 °C. When the Ce content is 0.03 wt% in the Sn–3.3Ag–0.2Cu–4.7Bi solder, the solder has the best wettability and the minimum growth rate of interfacial IMC layer.
- 9 June 2015
- Published by Wiley in Rare Metals
- Vol. 40 (3) , 714-719
Microstructure, wetting property of Sn–Ag–Cu–Bi– x Ce solder and IMC growth at solder/Cu interface during thermal cycling
The effects of adding small amounts of cerium (Ce) to Sn–3.3Ag–0.2Cu–4.7Bi solder on microstructure, wettability characteristic, interfacial morphology and the growth of interfacial intermetallic compound (IMC) during thermal cycling were investigated by optical microscopy (OM), scanning electron microscopy (SEM) and solderability tester. It is found that the β‐Sn phase, Ag 3 Sn phase and Cu 6 Sn 5 phase in the solder are refined and the wetting force increases. Ce is an active element; it more easily accumulates at the solder/flux interface in the molten state, which decreases the interfacial surface energy and reduces the driving force for IMC formation on Cu substrate; therefore, the thickness of IMC at the solder/Cu interface decreases when appropriate Ce was added into the solder. Moreover, the Ce‐containing solders have lower growth rate of interfacial IMC than solders without Ce during the thermal cycling between −55 and 125 °C. When the Ce content is 0.03 wt% in the Sn–3.3Ag–0.2Cu–4.7Bi solder, the solder has the best wettability and the minimum growth rate of interfacial IMC layer.