Andrea Muraro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrea Muraro has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Marica Rebai
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
12 shared publications - Giuseppe Gorini
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
10 shared publications - Marco Tardocchi
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
8 shared publications - Massimo Nocente
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
8 shared publications - Davide Rigamonti
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
7 shared publications - Enrico Perelli Cippo
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
7 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 4891-4900
Simulations of Vacuum Discharge Dynamics at the High-Voltage Padova Test Facility
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 4891-4900
Open AccessSimulations of Vacuum Discharge Dynamics at the High-Voltage Padova Test Facility
- Open Access
- 1 May 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5) , 055032
Operational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITER
ITER will be equipped with two types of diagnostics for fusion power measurement in deuterium–tritium plasmas: neutron flux monitors and neutron cameras, both absolutely counting the 14 MeV neutrons emitted by the D(T, 4 He)n reaction. The radial gamma-ray spectrometer (RGRS), though, has recently been considered as an additional fusion power diagnostic, detecting 17 MeV gamma-rays emitted by the radiative D(T, 5 He) γ channel of the DT reaction. This work describes the RGRS performance by determining the upper limit of its operational domain, strictly correlated with the expected background intensity and resulting between 2.6 ⋅ 10 17 neutrons per second and 3.2 ⋅ 10 18 neutrons per second. Based on this assessment, design optimization are introduced to fit the RGRS performances to the ITER requirements for safety-relevant fusion power measurements, for which the required operational range is between 2.4 ⋅ 10 19 neutrons per second and 3.2 ⋅ 10 20 neutrons per second. The expected different energy ranges covered by signal and background are exploited with the employment of a proper gamma-ray attenuator, allowing to widen and shift the RGRS operational domain toward the most relevant, high power plasma scenarios.
- 1 May 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5) , 055032
Open AccessOperational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITER
ITER will be equipped with two types of diagnostics for fusion power measurement in deuterium–tritium plasmas: neutron flux monitors and neutron cameras, both absolutely counting the 14 MeV neutrons emitted by the D(T, 4 He)n reaction. The radial gamma-ray spectrometer (RGRS), though, has recently been considered as an additional fusion power diagnostic, detecting 17 MeV gamma-rays emitted by the radiative D(T, 5 He) γ channel of the DT reaction. This work describes the RGRS performance by determining the upper limit of its operational domain, strictly correlated with the expected background intensity and resulting between 2.6 ⋅ 10 17 neutrons per second and 3.2 ⋅ 10 18 neutrons per second. Based on this assessment, design optimization are introduced to fit the RGRS performances to the ITER requirements for safety-relevant fusion power measurements, for which the required operational range is between 2.4 ⋅ 10 19 neutrons per second and 3.2 ⋅ 10 20 neutrons per second. The expected different energy ranges covered by signal and background are exploited with the employment of a proper gamma-ray attenuator, allowing to widen and shift the RGRS operational domain toward the most relevant, high power plasma scenarios.
- Open Access
- 20 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (6)
Particle discrimination capabilities of lanthanum halide scintillators
In the last few decades, lanthanum halide scintillators such as LaBr3(Ce), LaBr3(Ce+Sr) and LaCl3(Ce) have been extensively used for gamma ray spectroscopy measurements. They offer excellent energy resolution (about 3-4 % at 662keV) and fast scintillation time, allowing high counting rate measurements. These scintillators find applications in many research fields such as nuclear physics, astrophysics, nuclear fusion and nuclear medicine. More recently, thanks to the exploitation of the n-35Cl nuclear reaction channel, LaCl3(Ce) crystals have been used as neutron spectrometers. This opened up the opportunity to explore pulse shape discrimination algorithms for enabling the neutron/gamma discrimination. In this work, an innovative algorithm for particle discrimination applied to lanthanum halide scintillators is presented. The effectiveness of the algorithm has been demonstrated first on the intrinsic radioactivity measurement of the crystals, which is characterized by gamma ray emissions from 138La decay and alpha decays due to actinides contamination, and then with fast neutrons. The particle discrimination feature allows for a better description of the intrinsic activity of the crystal and improved background suppression when performing gamma ray spectroscopy measurements in low cross-section measurements or in a mixed gamma-neutron radiation field.
- 20 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (6)
Open AccessParticle discrimination capabilities of lanthanum halide scintillators
In the last few decades, lanthanum halide scintillators such as LaBr3(Ce), LaBr3(Ce+Sr) and LaCl3(Ce) have been extensively used for gamma ray spectroscopy measurements. They offer excellent energy resolution (about 3-4 % at 662keV) and fast scintillation time, allowing high counting rate measurements. These scintillators find applications in many research fields such as nuclear physics, astrophysics, nuclear fusion and nuclear medicine. More recently, thanks to the exploitation of the n-35Cl nuclear reaction channel, LaCl3(Ce) crystals have been used as neutron spectrometers. This opened up the opportunity to explore pulse shape discrimination algorithms for enabling the neutron/gamma discrimination. In this work, an innovative algorithm for particle discrimination applied to lanthanum halide scintillators is presented. The effectiveness of the algorithm has been demonstrated first on the intrinsic radioactivity measurement of the crystals, which is characterized by gamma ray emissions from 138La decay and alpha decays due to actinides contamination, and then with fast neutrons. The particle discrimination feature allows for a better description of the intrinsic activity of the crystal and improved background suppression when performing gamma ray spectroscopy measurements in low cross-section measurements or in a mixed gamma-neutron radiation field.
- Open Access
- 24 July 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (8) , 086036
Absolute measurement of the deuterium–tritium reaction gamma-ray emission in magnetic confinement fusion plasmas
The Joint European Torus performed its second deuterium–tritium (DT) campaign at the end of 2021. This unique opportunity was exploited to carry out the first absolute measurement in a magnetic confinement plasma of the total gamma-ray emission from the DT fusion reaction, namely the less probable (branching ratio = 2.4 ⋅ 10 − 5 ) electromagnetic counterpart of the main neutronic decay channel. A single line of sight gamma-ray spectrometer was employed for this purpose. Numerous challenges had to be addressed in order to pursue the goal: (1) characterise the detector beamline and its detection efficiency in absolute terms, (2) dealing with an extended and non-uniform source, (3) suppress the intense neutron background, (4) handle the high event rate at the detector and (5) discriminate between signal and background in the acquired energy spectrum. This paper describes the procedure adopted for measuring the total DT gamma-ray yield of 96 DT plasma discharges with event rates below hundred kHz. The results were validated through a comparison with the neutron yields provided by the Joint European Torus neutron monitors, revealing an outstanding 0.983 linear correlation. This work proves the feasibility to employ the gamma-ray emission of the DT fusion reaction as a secondary indicator for measuring the fusion power in magnetically confined DT plasmas.
- 24 July 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (8) , 086036
Open AccessAbsolute measurement of the deuterium–tritium reaction gamma-ray emission in magnetic confinement fusion plasmas
The Joint European Torus performed its second deuterium–tritium (DT) campaign at the end of 2021. This unique opportunity was exploited to carry out the first absolute measurement in a magnetic confinement plasma of the total gamma-ray emission from the DT fusion reaction, namely the less probable (branching ratio = 2.4 ⋅ 10 − 5 ) electromagnetic counterpart of the main neutronic decay channel. A single line of sight gamma-ray spectrometer was employed for this purpose. Numerous challenges had to be addressed in order to pursue the goal: (1) characterise the detector beamline and its detection efficiency in absolute terms, (2) dealing with an extended and non-uniform source, (3) suppress the intense neutron background, (4) handle the high event rate at the detector and (5) discriminate between signal and background in the acquired energy spectrum. This paper describes the procedure adopted for measuring the total DT gamma-ray yield of 96 DT plasma discharges with event rates below hundred kHz. The results were validated through a comparison with the neutron yields provided by the Joint European Torus neutron monitors, revealing an outstanding 0.983 linear correlation. This work proves the feasibility to employ the gamma-ray emission of the DT fusion reaction as a secondary indicator for measuring the fusion power in magnetically confined DT plasmas.
- 26 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075501
REVOLT-Upgrade: a software tool for fast, energy-resolved simulations of soft x-ray detectors in nuclear fusion experiments
The design of x-ray diagnostics for nuclear fusion (NF) experiments often requires a simulation tool that balances accuracy, speed, and computational efficiency; especially when several simulations are needed to investigate different experimental conditions, plasma scenarios, optimize diagnostic components and lines of sight configurations and test the feasibility of experimental measurements and analyses. Although Monte Carlo simulation tools (like GEANT4 and MCNP) offer high accuracy, they are often too computationally heavy for NF applications. For this reason, a software tool (written in C and Python) called ‘REVOLT’ was developed, trading a small degree of accuracy for significant gains in simulation speed and resource demands. This paper presents the enhanced capabilities of REVOLT: initially designed to compute transport matrices and shading effects, REVOLT has been upgraded specifically for x-ray pixelated-detector applications on NF experiments. Starting from the emissivity of the x-ray source (for example, a NF plasma), REVOLT-U calculates counts and energy spectra at each detector pixel, accounting for the detector efficiency and the x-ray attenuation through various gases and experimental components. The emissivity of the source can either be derived from independent simulations or directly computed by REVOLT-U using experimental data from different diagnostics. The upgrade is not only useful to improve the simulation of detector data, but also plays a crucial role in enabling tomographic reconstruction algorithms that offer both spatial and energy resolution. This paper focuses on the application of REVOLT-U to NF experiments equipped with gas electron multiplier (GEM) detectors. REVOLT-U has been validated using two different x-ray sources and geometries, with GEANT4 simulations serving as a reference standard. In addition, an example application of REVOLT-U is presented for two NF experiments: RFX-mod2 (Padova, Italy) and MAST-U (Culham, UK). For the MAST-U case, a comparison with experimental data is also included.
- 26 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075501
REVOLT-Upgrade: a software tool for fast, energy-resolved simulations of soft x-ray detectors in nuclear fusion experiments
The design of x-ray diagnostics for nuclear fusion (NF) experiments often requires a simulation tool that balances accuracy, speed, and computational efficiency; especially when several simulations are needed to investigate different experimental conditions, plasma scenarios, optimize diagnostic components and lines of sight configurations and test the feasibility of experimental measurements and analyses. Although Monte Carlo simulation tools (like GEANT4 and MCNP) offer high accuracy, they are often too computationally heavy for NF applications. For this reason, a software tool (written in C and Python) called ‘REVOLT’ was developed, trading a small degree of accuracy for significant gains in simulation speed and resource demands. This paper presents the enhanced capabilities of REVOLT: initially designed to compute transport matrices and shading effects, REVOLT has been upgraded specifically for x-ray pixelated-detector applications on NF experiments. Starting from the emissivity of the x-ray source (for example, a NF plasma), REVOLT-U calculates counts and energy spectra at each detector pixel, accounting for the detector efficiency and the x-ray attenuation through various gases and experimental components. The emissivity of the source can either be derived from independent simulations or directly computed by REVOLT-U using experimental data from different diagnostics. The upgrade is not only useful to improve the simulation of detector data, but also plays a crucial role in enabling tomographic reconstruction algorithms that offer both spatial and energy resolution. This paper focuses on the application of REVOLT-U to NF experiments equipped with gas electron multiplier (GEM) detectors. REVOLT-U has been validated using two different x-ray sources and geometries, with GEANT4 simulations serving as a reference standard. In addition, an example application of REVOLT-U is presented for two NF experiments: RFX-mod2 (Padova, Italy) and MAST-U (Culham, UK). For the MAST-U case, a comparison with experimental data is also included.
- Open Access
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of a measuring technique based on JET second D-T campaign (DTE2) experience for assessing fusion power at ITER during D-T operation using the radial gamma-ray spectrometer
The ITER Radial Gamma-Ray Spectrometer (RGRS) consists of three gamma-ray detectors observing the plasma through three collimated, coplanar, radial lines of sight (LoS). The system was initially designed to monitor the runaway electron emission and the alpha-particle density profile [Nocente et al., Nucl. Fusion 57, 076016 (2017)]. This work presents a novel technique for measuring the fusion power during D-T operation using the RGRS. This method is based on the absolute measurement of the 17 MeV fusion gamma-rays and a semi-analytical computation of their transport from the plasma source to the detectors. This approach was initially developed and tested at JET during the second D-T campaign (DTE2) on a single LoS diagnostic [Dal Molin et al., Phys. Rev. Lett. (submitted) (2024); Rebai et al., Phys. Rev. C (submitted) (2024); and Marcer et al., Nucl. Fusion (unpublished) (2024)]. This work exploits the multiple LoS of the RGRS to create a combined virtual diagnostic whose detected fraction of the total plasma emission is less affected by variations in the plasma emission profile, reducing systematic uncertainties on the estimated total emission, compared to the individual detectors.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Open AccessDevelopment of a measuring technique based on JET second D-T campaign (DTE2) experience for assessing fusion power at ITER during D-T operation using the radial gamma-ray spectrometer
The ITER Radial Gamma-Ray Spectrometer (RGRS) consists of three gamma-ray detectors observing the plasma through three collimated, coplanar, radial lines of sight (LoS). The system was initially designed to monitor the runaway electron emission and the alpha-particle density profile [Nocente et al., Nucl. Fusion 57, 076016 (2017)]. This work presents a novel technique for measuring the fusion power during D-T operation using the RGRS. This method is based on the absolute measurement of the 17 MeV fusion gamma-rays and a semi-analytical computation of their transport from the plasma source to the detectors. This approach was initially developed and tested at JET during the second D-T campaign (DTE2) on a single LoS diagnostic [Dal Molin et al., Phys. Rev. Lett. (submitted) (2024); Rebai et al., Phys. Rev. C (submitted) (2024); and Marcer et al., Nucl. Fusion (unpublished) (2024)]. This work exploits the multiple LoS of the RGRS to create a combined virtual diagnostic whose detected fraction of the total plasma emission is less affected by variations in the plasma emission profile, reducing systematic uncertainties on the estimated total emission, compared to the individual detectors.
- 30 July 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (5) , 055102
Measurement of the Gamma-Ray-to-Neutron Branching Ratio for the Deuterium-Tritium Reaction in Magnetic Confinement Fusion Plasmas
At present, magnetic confinement fusion devices rely solely on absolute neutron counting as a direct way of measuring fusion power. Absolute counting of deuterium-tritium gamma rays could provide the secondary neutron-independent technique required for the validation of scientific results and as a licensing tool for future power plants. However, this approach necessitates an accurate determination of the gamma-ray-to-neutron branching ratio. The gamma-ray-to-neutron branching ratio for the deuterium-tritium reaction was determined in magnetic confinement fusion plasmas at the Joint European Torus in predominantly deuterium beam heated plasmas. The branching ratio was found to be equal to over the deuterium energy range of . This accurate determination of the deuterium-tritium branching ratio paves the way for a direct and neutron-independent measurement of fusion power in magnetic confinement fusion reactors, based on the absolute counting of deuterium-tritium gamma rays.- 30 July 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (5) , 055102
Measurement of the Gamma-Ray-to-Neutron Branching Ratio for the Deuterium-Tritium Reaction in Magnetic Confinement Fusion Plasmas
At present, magnetic confinement fusion devices rely solely on absolute neutron counting as a direct way of measuring fusion power. Absolute counting of deuterium-tritium gamma rays could provide the secondary neutron-independent technique required for the validation of scientific results and as a licensing tool for future power plants. However, this approach necessitates an accurate determination of the gamma-ray-to-neutron branching ratio. The gamma-ray-to-neutron branching ratio for the deuterium-tritium reaction was determined in magnetic confinement fusion plasmas at the Joint European Torus in predominantly deuterium beam heated plasmas. The branching ratio was found to be equal to over the deuterium energy range of . This accurate determination of the deuterium-tritium branching ratio paves the way for a direct and neutron-independent measurement of fusion power in magnetic confinement fusion reactors, based on the absolute counting of deuterium-tritium gamma rays.- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 660-665
The CNESM neutron imaging diagnostic for SPIDER beam source
- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 660-665
The CNESM neutron imaging diagnostic for SPIDER beam source
- 1 August 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (08) , C08012
Development and characterization of a new soft x-ray diagnostic concept for tokamaks
- 1 August 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (08) , C08012
Development and characterization of a new soft x-ray diagnostic concept for tokamaks
- 1 December 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 912, 36-38
Response of a telescope proton recoil spectrometer based on a YAP: Ce scintillator to 5–80 MeV protons for applications to measurements of the fast neutron spectrum at the ChipIr irradiation facility
- 1 December 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 912, 36-38
Response of a telescope proton recoil spectrometer based on a YAP: Ce scintillator to 5–80 MeV protons for applications to measurements of the fast neutron spectrum at the ChipIr irradiation facility