Takaharu Kudoh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takaharu Kudoh has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
Hitoshi Ikushima
Department of Therapeutic Radiology, Tokushima University Graduate School of Biomedical Sciences, Tokushima, Japan
6 shared publicationsShunsuke Furutani
Department of Radiology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
5 shared publications- Youji Miyamoto
Department of Oral Surgery, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
5 shared publications Hiromu Nishitani
Department of Radiology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
4 shared publications- Kunio Ishikawa
Department of Biomaterials, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
4 shared publications Takashi Kawanaka
Department of Radiology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
4 shared publications
Latest Publications
- 21 July 2026
- Published by Springer Nature in Oral Radiology
- Vol. 42 (4) , 1295-1303
Multiple myeloma diagnosed after contrast-enhanced computed tomography without renal complications: a case report with literature review
- 21 July 2026
- Published by Springer Nature in Oral Radiology
- Vol. 42 (4) , 1295-1303
Multiple myeloma diagnosed after contrast-enhanced computed tomography without renal complications: a case report with literature review
- Open Access
- 17 June 2025
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 36 (1) , 1-9
Fabrication and evaluation of carbonate apatite granule sponges using fish-derived collagen for advanced synthetic bone substitutes
Carbonate apatite (CO3Ap) granules have been employed as advanced bone substitutes owing to their capacity to remodel into new natural bone, aligning with the bone remodeling process. Their application spans dental clinical fields in both Japan and the US. Nonetheless, owing to the granular nature of CO3Ap, certain challenges in the application of these materials can arise, such as intraoperative scattering and postoperative migration. To address these issues, we integrated CO3Ap granules with collagen to generate a sponge-like composite. Collagen, typically derived from bovine or porcine sources, is commonly utilized in clinical settings despite the potential for infections, including parasitic zoonosis. For the purposes of this study, we selected fish-derived collagen (FC), which minimizes the risk of zoonotic complications. Compared with CO3Ap-G, the CO3Ap granule/FC composites (CO3Ap-G/FCs) fabricated in this study were characterized by an enhanced handling performance. Bone regeneration ability was assessed by implanting these composites into critical-size defects in rat calvarial bones for 2–4 weeks using CO3Ap-G and FC as controls. Radiographic and histological examinations revealed that the bone-regenerative capacity of CO3Ap-G/FCs was equivalent to that of CO3Ap-G. We accordingly conclude that sponge-like CO3Ap-G/FC composites have potential utility as ideal bone substitutes, in that they can be manipulated with forceps, bent, and cut with scissors, without losing the bone-regenerative properties of CO3Ap-G. Graphical Abstract
- 17 June 2025
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 36 (1) , 1-9
Open AccessFabrication and evaluation of carbonate apatite granule sponges using fish-derived collagen for advanced synthetic bone substitutes
Carbonate apatite (CO3Ap) granules have been employed as advanced bone substitutes owing to their capacity to remodel into new natural bone, aligning with the bone remodeling process. Their application spans dental clinical fields in both Japan and the US. Nonetheless, owing to the granular nature of CO3Ap, certain challenges in the application of these materials can arise, such as intraoperative scattering and postoperative migration. To address these issues, we integrated CO3Ap granules with collagen to generate a sponge-like composite. Collagen, typically derived from bovine or porcine sources, is commonly utilized in clinical settings despite the potential for infections, including parasitic zoonosis. For the purposes of this study, we selected fish-derived collagen (FC), which minimizes the risk of zoonotic complications. Compared with CO3Ap-G, the CO3Ap granule/FC composites (CO3Ap-G/FCs) fabricated in this study were characterized by an enhanced handling performance. Bone regeneration ability was assessed by implanting these composites into critical-size defects in rat calvarial bones for 2–4 weeks using CO3Ap-G and FC as controls. Radiographic and histological examinations revealed that the bone-regenerative capacity of CO3Ap-G/FCs was equivalent to that of CO3Ap-G. We accordingly conclude that sponge-like CO3Ap-G/FC composites have potential utility as ideal bone substitutes, in that they can be manipulated with forceps, bent, and cut with scissors, without losing the bone-regenerative properties of CO3Ap-G. Graphical Abstract
- Open Access
- 31 December 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (1) , 1-11
Reconstruction of rabbit mandibular bone defects using carbonate apatite honeycomb blocks with an interconnected porous structure
Carbonate apatite (CO3Ap) granules are useful as a bone substitute because they can be remodeled to new natural bone in a manner that conforms to the bone remodeling process. However, reconstructing large bone defects using CO3Ap granules is difficult because of their granular shape. Therefore, we fabricated CO3Ap honeycomb blocks (HCBs) with continuous unidirectional pores. We aimed to elucidate the tissue response and availability of CO3Ap HCBs in the reconstruction of rabbit mandibular bone defects after marginal mandibulectomy. The percentages of the remaining CO3Ap area and calcified bone area (newly formed bone) were estimated from the histological images. CO3Ap area was 49.1 ± 4.9%, 30.3 ± 3.5%, and 25.5 ± 8.8%, whereas newly formed bone area was 3.0 ± 0.6%, 24.3 ± 3.3%, and 34.7 ± 4.8% at 4, 8, and 12 weeks, respectively, after implantation. Thus, CO3Ap HCBs were gradually resorbed and replaced by new bone. The newly formed bone penetrated most of the pores in the CO3Ap HCBs at 12 weeks after implantation. By contrast, the granulation tissue scarcely invaded the CO3Ap HCBs. Some osteoclasts invaded the wall of CO3Ap HCBs, making resorption pits. Furthermore, many osteoblasts were found on the newly formed bone, indicating ongoing bone remodeling. Blood vessels were also formed inside most of the pores in the CO3Ap HCBs. These findings suggest that CO3Ap HCBs have good osteoconductivity and can be used for the reconstruction of large mandibular bone defects. Graphical Abstract
- 31 December 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (1) , 1-11
Open AccessReconstruction of rabbit mandibular bone defects using carbonate apatite honeycomb blocks with an interconnected porous structure
Carbonate apatite (CO3Ap) granules are useful as a bone substitute because they can be remodeled to new natural bone in a manner that conforms to the bone remodeling process. However, reconstructing large bone defects using CO3Ap granules is difficult because of their granular shape. Therefore, we fabricated CO3Ap honeycomb blocks (HCBs) with continuous unidirectional pores. We aimed to elucidate the tissue response and availability of CO3Ap HCBs in the reconstruction of rabbit mandibular bone defects after marginal mandibulectomy. The percentages of the remaining CO3Ap area and calcified bone area (newly formed bone) were estimated from the histological images. CO3Ap area was 49.1 ± 4.9%, 30.3 ± 3.5%, and 25.5 ± 8.8%, whereas newly formed bone area was 3.0 ± 0.6%, 24.3 ± 3.3%, and 34.7 ± 4.8% at 4, 8, and 12 weeks, respectively, after implantation. Thus, CO3Ap HCBs were gradually resorbed and replaced by new bone. The newly formed bone penetrated most of the pores in the CO3Ap HCBs at 12 weeks after implantation. By contrast, the granulation tissue scarcely invaded the CO3Ap HCBs. Some osteoclasts invaded the wall of CO3Ap HCBs, making resorption pits. Furthermore, many osteoblasts were found on the newly formed bone, indicating ongoing bone remodeling. Blood vessels were also formed inside most of the pores in the CO3Ap HCBs. These findings suggest that CO3Ap HCBs have good osteoconductivity and can be used for the reconstruction of large mandibular bone defects. Graphical Abstract
- 7 March 2022
- Published by Springer Nature in Oral Radiology
- Vol. 39 (1) , 41-50
Radiomics analysis of [18F]-fluoro-2-deoxyglucose positron emission tomography for the prediction of cervical lymph node metastasis in tongue squamous cell carcinoma
Objectives This study aimed to create a predictive model for cervical lymph node metastasis (CLNM) in patients with tongue squamous cell carcinoma (SCC) based on radiomics features detected by [18F]-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography (PET). Methods A total of 40 patients with tongue SCC who underwent 18F-FDG PET imaging during their first medical examination were enrolled. During the follow-up period (mean 28 months), 20 patients had CLNM, including six with late CLNM, whereas the remaining 20 patients did not have CLNM. Radiomics features were extracted from 18F-FDG PET images of all patients irrespective of metal artifact, and clinicopathological factors were obtained from the medical records. Late CLNM was defined as the CLNM that occurred after major treatment. The least absolute shrinkage and selection operator (LASSO) model was used for radiomics feature selection and sequential data fitting. The receiver operating characteristic curve analysis was used to assess the predictive performance of the 18F-FDG PET-based model and clinicopathological factors model (CFM) for CLNM. Results Six radiomics features were selected from LASSO analysis. The average values of the area under the curve (AUC), accuracy, sensitivity, and specificity of radiomics analysis for predicting CLNM from 18F-FDG PET images were 0.79, 0.68, 0.65, and 0.70, respectively. In contrast, those of the CFM were 0.54, 0.60, 0.60, and 0.60, respectively. The 18F-FDG PET-based model showed significantly higher AUC than that of the CFM. Conclusions The 18F-FDG PET-based model has better potential for diagnosing CLNM and predicting late CLNM in patients with tongue SCC than the CFM.
- 7 March 2022
- Published by Springer Nature in Oral Radiology
- Vol. 39 (1) , 41-50
Radiomics analysis of [18F]-fluoro-2-deoxyglucose positron emission tomography for the prediction of cervical lymph node metastasis in tongue squamous cell carcinoma
Objectives This study aimed to create a predictive model for cervical lymph node metastasis (CLNM) in patients with tongue squamous cell carcinoma (SCC) based on radiomics features detected by [18F]-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography (PET). Methods A total of 40 patients with tongue SCC who underwent 18F-FDG PET imaging during their first medical examination were enrolled. During the follow-up period (mean 28 months), 20 patients had CLNM, including six with late CLNM, whereas the remaining 20 patients did not have CLNM. Radiomics features were extracted from 18F-FDG PET images of all patients irrespective of metal artifact, and clinicopathological factors were obtained from the medical records. Late CLNM was defined as the CLNM that occurred after major treatment. The least absolute shrinkage and selection operator (LASSO) model was used for radiomics feature selection and sequential data fitting. The receiver operating characteristic curve analysis was used to assess the predictive performance of the 18F-FDG PET-based model and clinicopathological factors model (CFM) for CLNM. Results Six radiomics features were selected from LASSO analysis. The average values of the area under the curve (AUC), accuracy, sensitivity, and specificity of radiomics analysis for predicting CLNM from 18F-FDG PET images were 0.79, 0.68, 0.65, and 0.70, respectively. In contrast, those of the CFM were 0.54, 0.60, 0.60, and 0.60, respectively. The 18F-FDG PET-based model showed significantly higher AUC than that of the CFM. Conclusions The 18F-FDG PET-based model has better potential for diagnosing CLNM and predicting late CLNM in patients with tongue SCC than the CFM.
- Open Access
- 29 August 2018
- Published by Wiley in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 12 (10) , 2077-2087
Fabrication and evaluation of carbonate apatite-coated calcium carbonate bone substitutes for bone tissue engineering
Carbonate apatite‐coated calcium carbonate (CO3Ap/CaCO3) was fabricated through a dissolution–precipitation reaction using CaCO3 granules as a precursor to accelerate bone replacement based on superior osteoconductivity of the CO3Ap shell, along with Ca2+ release from the CaCO3 core and quicker resorption of the CaCO3 core. In the present study, CaCO3, 10% CO3Ap/CaCO3, 30% CO3Ap/CaCO3, and CO3Ap granules were fabricated and examined histologically to evaluate their potential as bone substitutes. Larger contents of CaCO3 in the granules resulted in higher Ca2+ release and promoted cell proliferation of murine preosteoblasts at 6 days compared with CO3Ap. Interestingly, in a rabbit femur defect model, 10% CO3Ap/CaCO3 induced significantly higher new bone formation and higher material resorption compared with CO3Ap at 8 weeks. Nevertheless, CO3Ap showed a superior osteoconductive potential compared with 10% CO3Ap/CaCO3 at 8 weeks. All tested granules were most likely resorbed by cell mediation including multinucleated giant cell functions. Therefore, we conclude that CO3Ap/CaCO3 has a positive potential for bone tissue engineering based on well‐controlled calcium release, bone formation, and material resorption.
- 29 August 2018
- Published by Wiley in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 12 (10) , 2077-2087
Open AccessFabrication and evaluation of carbonate apatite-coated calcium carbonate bone substitutes for bone tissue engineering
Carbonate apatite‐coated calcium carbonate (CO3Ap/CaCO3) was fabricated through a dissolution–precipitation reaction using CaCO3 granules as a precursor to accelerate bone replacement based on superior osteoconductivity of the CO3Ap shell, along with Ca2+ release from the CaCO3 core and quicker resorption of the CaCO3 core. In the present study, CaCO3, 10% CO3Ap/CaCO3, 30% CO3Ap/CaCO3, and CO3Ap granules were fabricated and examined histologically to evaluate their potential as bone substitutes. Larger contents of CaCO3 in the granules resulted in higher Ca2+ release and promoted cell proliferation of murine preosteoblasts at 6 days compared with CO3Ap. Interestingly, in a rabbit femur defect model, 10% CO3Ap/CaCO3 induced significantly higher new bone formation and higher material resorption compared with CO3Ap at 8 weeks. Nevertheless, CO3Ap showed a superior osteoconductive potential compared with 10% CO3Ap/CaCO3 at 8 weeks. All tested granules were most likely resorbed by cell mediation including multinucleated giant cell functions. Therefore, we conclude that CO3Ap/CaCO3 has a positive potential for bone tissue engineering based on well‐controlled calcium release, bone formation, and material resorption.
- 21 July 2018
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 29 (8) , 1-11
Compositional and histological comparison of carbonate apatite fabricated by dissolution–precipitation reaction and Bio-Oss®
Carbonate apatite (CO3Ap) is an inorganic component of bone. This study aimed to compare the composition and tissue response to of CO3Ap (CO3Ap-DP) fabricated by the dissolution–precipitation reaction using calcite as a precursor and Bio-Oss®, which is widely used in orthopedic and dental fields as a synthetic bone substitute. X-ray diffraction and Fourier transform infrared results showed that CO3Ap-DP and Bio-Oss® were both B-type carbonate apatite with low crystallinity. The average sizes of CO3Ap-DP and Bio-Oss® granules were 450 ± 58 and 667 ± 168μ m, respectively, and their carbonate contents were 12.1 ± 0.6 and 5.6 ± 0.1 wt%, respectively. CO3Ap-DP had a larger amount of CO3 than Bio-Oss® but higher crystallinity than Bio-Oss®. When a bone defect made at the femur of rabbits was reconstructed with CO3Ap-DP and Bio-Oss®, CO3Ap-DP granules were partially replaced with bone, whereas Bio-Oss® remained at 8 weeks after implantation. CO3Ap-DP granules elicited a significantly larger amount of new bone formation at the cortical bone portion than Bio-Oss® at 4 weeks after the implantation. The results obtained in the present study demonstrated that CO3Ap-DP and Bio-Oss® showed different behavior even though they were both classified as CO3Ap. The CO3 content in CO3Ap played a more important role than the crystallinity of CO3Ap for replacement to bone and high osteoconductivity.
- 21 July 2018
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 29 (8) , 1-11
Compositional and histological comparison of carbonate apatite fabricated by dissolution–precipitation reaction and Bio-Oss®
Carbonate apatite (CO3Ap) is an inorganic component of bone. This study aimed to compare the composition and tissue response to of CO3Ap (CO3Ap-DP) fabricated by the dissolution–precipitation reaction using calcite as a precursor and Bio-Oss®, which is widely used in orthopedic and dental fields as a synthetic bone substitute. X-ray diffraction and Fourier transform infrared results showed that CO3Ap-DP and Bio-Oss® were both B-type carbonate apatite with low crystallinity. The average sizes of CO3Ap-DP and Bio-Oss® granules were 450 ± 58 and 667 ± 168μ m, respectively, and their carbonate contents were 12.1 ± 0.6 and 5.6 ± 0.1 wt%, respectively. CO3Ap-DP had a larger amount of CO3 than Bio-Oss® but higher crystallinity than Bio-Oss®. When a bone defect made at the femur of rabbits was reconstructed with CO3Ap-DP and Bio-Oss®, CO3Ap-DP granules were partially replaced with bone, whereas Bio-Oss® remained at 8 weeks after implantation. CO3Ap-DP granules elicited a significantly larger amount of new bone formation at the cortical bone portion than Bio-Oss® at 4 weeks after the implantation. The results obtained in the present study demonstrated that CO3Ap-DP and Bio-Oss® showed different behavior even though they were both classified as CO3Ap. The CO3 content in CO3Ap played a more important role than the crystallinity of CO3Ap for replacement to bone and high osteoconductivity.
- 1 January 2015
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 119 (1) , e41-e48
Neuroendocrine tumor in the mandible: a case report with imaging and histopathologic findings
- 1 January 2015
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 119 (1) , e41-e48
Neuroendocrine tumor in the mandible: a case report with imaging and histopathologic findings
- Open Access
- 16 October 2014
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2014, 1-4
Prevalence and Imaging Characteristics of Palatine Tonsilloliths Detected by CT in 2,873 Consecutive Patients
Aim. Tonsilloliths are calcified structures that develop in tonsillar crypts. They are commonly detected in daily clinical practice. The prevalence of tonsilloliths was 16 to 24% in previous reports, but it is inconsistent with clinical experience. The aim of this study is to clarify the prevalence, number, and size distribution of tonsilloliths using computed tomography (CT) in a relatively large number of patients. Materials and Methods. We retrospectively reviewed the scans of 2,873 patients referred for CT examinations with regard to tonsilloliths. Results. Palatine tonsilloliths were found in 1,145 out of 2,873 patients (39.9%). The prevalence of tonsilloliths increased with age, and most commonly in patients of ages 50–69. The prevalence in the 30s and younger was statistically lower than in the 40s and older (P < 0.05). The number of tonsilloliths per palatine tonsil ranged from one to 18. The size of the tonsilloliths ranged from 1 to 10 mm. For the patients with multiple CT examinations, the number of tonsilloliths increased in 51 (3.9%) and decreased in 84 (6.5%) of the tonsils. Conclusions. As palatine tonsilloliths are common conditions, screenings for tonsilloliths during the diagnosis of soft tissue calcifications should be included in routine diagnostic imaging.
- 16 October 2014
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2014, 1-4
Open AccessPrevalence and Imaging Characteristics of Palatine Tonsilloliths Detected by CT in 2,873 Consecutive Patients
Aim. Tonsilloliths are calcified structures that develop in tonsillar crypts. They are commonly detected in daily clinical practice. The prevalence of tonsilloliths was 16 to 24% in previous reports, but it is inconsistent with clinical experience. The aim of this study is to clarify the prevalence, number, and size distribution of tonsilloliths using computed tomography (CT) in a relatively large number of patients. Materials and Methods. We retrospectively reviewed the scans of 2,873 patients referred for CT examinations with regard to tonsilloliths. Results. Palatine tonsilloliths were found in 1,145 out of 2,873 patients (39.9%). The prevalence of tonsilloliths increased with age, and most commonly in patients of ages 50–69. The prevalence in the 30s and younger was statistically lower than in the 40s and older (P < 0.05). The number of tonsilloliths per palatine tonsil ranged from one to 18. The size of the tonsilloliths ranged from 1 to 10 mm. For the patients with multiple CT examinations, the number of tonsilloliths increased in 51 (3.9%) and decreased in 84 (6.5%) of the tonsils. Conclusions. As palatine tonsilloliths are common conditions, screenings for tonsilloliths during the diagnosis of soft tissue calcifications should be included in routine diagnostic imaging.
- Open Access
- 1 January 2012
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 53 (1) , 130-137
Shielding Effect of a Customized Intraoral Mold Including Lead Material in High-dose-rate 192-Ir Brachytherapy for Oral Cavity Cancer
A high-dose-rate (HDR) 192-Ir brachytherapy using a customized intraoral mold is effective for superficial oral cavity cancer, and the surrounding normal tissue is kept away from the radioactive source with gauze pads and/or mouth piece for reducing the dose on the normal tissues. In the Tokushima university hospital, the mold has a lead shield which utilizes the space prepared with sufficient border-molding by a specific dental technique using modeling compound. In HDR 192-Ir brachytherapy using a lead shielded customized intraoral mold, there are no reports measuring the absorbed dose. The purpose of the present study is to measure the absorbed dose and discuss the optimum thickness of lead in HDR 192-Ir brachytherapy using a customized intraoral mold with lead shield using a 1 cm thickness mimic mold. The thickness of lead in the mold could be changed by varying the arrangement of 0.1 cm thickness sheet of the acrylic resin plate and lead. The measured doses at the lateral surface of the mold with thermoluminescence dosimeter were reduced to 1.12, 0.79, 0.57, 0.41, 0.31, 0.24 and 0.19 Gy and the ratios to the prescription dose were reduced to 56, 40, 29, 21, 16, 12 and 10 percent as lead thickness increased from 0 to 0.6 cm in 0.1 cm increments, respectively. A 0.3 cm thickness lead was considered to be required for a 1 cm thickness mold, and it was necessary to thicken the lead as much as possible with the constraint of limited space in the oral cavity, especially at the fornix vestibule.
- 1 January 2012
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 53 (1) , 130-137
Open AccessShielding Effect of a Customized Intraoral Mold Including Lead Material in High-dose-rate 192-Ir Brachytherapy for Oral Cavity Cancer
A high-dose-rate (HDR) 192-Ir brachytherapy using a customized intraoral mold is effective for superficial oral cavity cancer, and the surrounding normal tissue is kept away from the radioactive source with gauze pads and/or mouth piece for reducing the dose on the normal tissues. In the Tokushima university hospital, the mold has a lead shield which utilizes the space prepared with sufficient border-molding by a specific dental technique using modeling compound. In HDR 192-Ir brachytherapy using a lead shielded customized intraoral mold, there are no reports measuring the absorbed dose. The purpose of the present study is to measure the absorbed dose and discuss the optimum thickness of lead in HDR 192-Ir brachytherapy using a customized intraoral mold with lead shield using a 1 cm thickness mimic mold. The thickness of lead in the mold could be changed by varying the arrangement of 0.1 cm thickness sheet of the acrylic resin plate and lead. The measured doses at the lateral surface of the mold with thermoluminescence dosimeter were reduced to 1.12, 0.79, 0.57, 0.41, 0.31, 0.24 and 0.19 Gy and the ratios to the prescription dose were reduced to 56, 40, 29, 21, 16, 12 and 10 percent as lead thickness increased from 0 to 0.6 cm in 0.1 cm increments, respectively. A 0.3 cm thickness lead was considered to be required for a 1 cm thickness mold, and it was necessary to thicken the lead as much as possible with the constraint of limited space in the oral cavity, especially at the fornix vestibule.