Joseph Ocheje Okeme
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joseph Ocheje Okeme has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Miriam L. Diamond
University of Toronto
6 shared publications - Anya Guo
McMaster University
5 shared publications - Liisa M. Jantunen
Department of Earth Sciences, University of Toronto, 22 Ursula Franklin Street, Toronto, Ontario M5S 3B1, Canada
4 shared publications - Timothy F. M. Rodgers
Department of Civil Engineering, University of British Columbia, Vancouver, British Columbia, V6T 1Z4, Canada
4 shared publications Parshawn Amini
Department of Chemistry & Chemical Biology
3 shared publications- Parshawn Amini
Department of Chemistry & Chemical Biology, McMaster University, Hamilton, Canada
3 shared publications
Latest Publications
- 2 November 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (45) , 32440-32454
Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure
Calibrated wearable passive air samplers are critical tools for accessibly quantifying individualized and population exposures to airborne pollution, a leading cause of chronic disease. Our lab recently introduced passive sampling eyewear (PSE) to address gaps in tools tailored for measuring and mitigating risks from inhalation exposure. The PSE, like most existing designs of wearable samplers, is largely uncalibrated. An exception is the polydimethylsiloxane (PDMS) brooch, and mini-polyurethane foam (PUF) samplers, which have been calibrated for only 27 compounds. Here, we calibrate PSE against active air samplers codeployed in both stationary and wearable forms in office and home environments to capture a wide range of exposure scenarios. We report sampling rates (RS) and inhalation exposure for over 200 features covering diverse physical-chemical properties measured using the Orbitrap gas chromatography coupled to mass spectrometry (GC–MS) system in both targeted and nontargeted modes. RS were 0.70 ± 0.62 m3 day–1 dm–2 for stationary and 0.85 ± 0.68 m3 day–1 dm–2 for wearable deployments, with no significant difference (p = 0.06) between the deployment types. Wearable calibration captured higher RS and variability, as expected for personal sampling, because participants’ movement and daily activity can alter airflow and disrupt the stagnant air-boundary layer around the sampler. In terms of analysis mode, RS derived from targeted and nontargeted analysis (NTA) were reasonably comparable for a given compound, differing by ∼1.5-fold, boosting confidence in using NTA approaches for expanding databases of RS. Applying the wearable RS, the profiles and levels of inhalation exposure varied widely between participants when at home versus in offices, reflecting differences in exposure sources and dynamics between the two environments. Overall, the findings from both the calibration and field studies represent a significant step toward quantitatively assessing inhalation exposure using PSE.
- 2 November 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (45) , 32440-32454
Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure
Calibrated wearable passive air samplers are critical tools for accessibly quantifying individualized and population exposures to airborne pollution, a leading cause of chronic disease. Our lab recently introduced passive sampling eyewear (PSE) to address gaps in tools tailored for measuring and mitigating risks from inhalation exposure. The PSE, like most existing designs of wearable samplers, is largely uncalibrated. An exception is the polydimethylsiloxane (PDMS) brooch, and mini-polyurethane foam (PUF) samplers, which have been calibrated for only 27 compounds. Here, we calibrate PSE against active air samplers codeployed in both stationary and wearable forms in office and home environments to capture a wide range of exposure scenarios. We report sampling rates (RS) and inhalation exposure for over 200 features covering diverse physical-chemical properties measured using the Orbitrap gas chromatography coupled to mass spectrometry (GC–MS) system in both targeted and nontargeted modes. RS were 0.70 ± 0.62 m3 day–1 dm–2 for stationary and 0.85 ± 0.68 m3 day–1 dm–2 for wearable deployments, with no significant difference (p = 0.06) between the deployment types. Wearable calibration captured higher RS and variability, as expected for personal sampling, because participants’ movement and daily activity can alter airflow and disrupt the stagnant air-boundary layer around the sampler. In terms of analysis mode, RS derived from targeted and nontargeted analysis (NTA) were reasonably comparable for a given compound, differing by ∼1.5-fold, boosting confidence in using NTA approaches for expanding databases of RS. Applying the wearable RS, the profiles and levels of inhalation exposure varied widely between participants when at home versus in offices, reflecting differences in exposure sources and dynamics between the two environments. Overall, the findings from both the calibration and field studies represent a significant step toward quantitatively assessing inhalation exposure using PSE.
- 18 June 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (7) , 1935-1948
Nontargeted Calibration: A Novel Method for Understanding Uptake Kinetics of Diverse Compounds Using Passive Air Samplers
- 18 June 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (7) , 1935-1948
Nontargeted Calibration: A Novel Method for Understanding Uptake Kinetics of Diverse Compounds Using Passive Air Samplers
- Open Access
- 13 January 2026
- Published by Royal Society of Chemistry (RSC) in Digital Discovery
- Vol. 5 (2) , 835-843
LivePyxel: accelerating image annotations with a Python-integrated webcam live streaming
LivePyxel is a pixel-level annotation editor designed for the development of image segmentation models. Inspired by popular graphics editors, it supports precise annotations through Bézier spline–based tools and live-feed webcam integration.
- 13 January 2026
- Published by Royal Society of Chemistry (RSC) in Digital Discovery
- Vol. 5 (2) , 835-843
Open AccessLivePyxel: accelerating image annotations with a Python-integrated webcam live streaming
LivePyxel is a pixel-level annotation editor designed for the development of image segmentation models. Inspired by popular graphics editors, it supports precise annotations through Bézier spline–based tools and live-feed webcam integration.
- 18 December 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (1) , 1321-1333
Unexpected Mobility and Bioaccumulation of Effluent- and Biosolids-Borne PBDEs and Chlorinated Paraffins in an Organic-Rich Soil System
Land application of wastewater residuals introduces hydrophobic contaminants into soils, where high organic matter (OM) is widely assumed to ensure contaminant immobilization. We tested this assumption in greenhouse mesocosms using an organic-rich soil (50% OM, 50% sand) receiving selected polybrominated diphenyl ethers (PBDEs) and chlorinated paraffins (CPs) from biosolids or effluent. The soil's composition allowed us to test the conflict between high potential for contaminant sorption (to OM) and high hydraulic conductivity (from sand). Despite high soil retention of contaminants (>70%), response curves indicated significant leaching from both sources with up to 11.5% of a short-chain CP (SCCP) being mobilized. While phytoaccumulation was minimal (BAFdw < 1), earthworms accumulated high loads (BAFdw up to 23), suggesting a potent trophic transfer pathway. Both mobility and bioaccumulation were source-dependent. For instance, effluent-irrigated soils showed more than 6-fold greater medium-chain CPs (MCCPs) leaching (6.7% vs ∼1%) and higher bioavailability than biosolids-amended soils. These findings suggest hydraulic flux can override the sequestration capacity of organic-rich soils, highlighting the limitations of OM's role as an effective sink under dynamic, nonequilibrium conditions. The study provides critical data urging a re-evaluation of risk assessment models for land-applied wastes.
- 18 December 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (1) , 1321-1333
Unexpected Mobility and Bioaccumulation of Effluent- and Biosolids-Borne PBDEs and Chlorinated Paraffins in an Organic-Rich Soil System
Land application of wastewater residuals introduces hydrophobic contaminants into soils, where high organic matter (OM) is widely assumed to ensure contaminant immobilization. We tested this assumption in greenhouse mesocosms using an organic-rich soil (50% OM, 50% sand) receiving selected polybrominated diphenyl ethers (PBDEs) and chlorinated paraffins (CPs) from biosolids or effluent. The soil's composition allowed us to test the conflict between high potential for contaminant sorption (to OM) and high hydraulic conductivity (from sand). Despite high soil retention of contaminants (>70%), response curves indicated significant leaching from both sources with up to 11.5% of a short-chain CP (SCCP) being mobilized. While phytoaccumulation was minimal (BAFdw < 1), earthworms accumulated high loads (BAFdw up to 23), suggesting a potent trophic transfer pathway. Both mobility and bioaccumulation were source-dependent. For instance, effluent-irrigated soils showed more than 6-fold greater medium-chain CPs (MCCPs) leaching (6.7% vs ∼1%) and higher bioavailability than biosolids-amended soils. These findings suggest hydraulic flux can override the sequestration capacity of organic-rich soils, highlighting the limitations of OM's role as an effective sink under dynamic, nonequilibrium conditions. The study provides critical data urging a re-evaluation of risk assessment models for land-applied wastes.
- 4 December 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (49) , 26384-26395
Introducing Eyewear Lenses as Passive Samplers for Assessing Inhalation Exposure to Airborne Chemicals
Wearable passive samplers are inexpensive tools for assessing personal exposure to diverse contaminants through a combination of exposure pathways. This versatility, however, can be a disadvantage when it is critical to assess a specific pathway. Here, we aim to develop eyewear lenses as passive samplers that can capture inhalation exposure as a primary pathway for airborne contaminants. We designed polycarbonate lens samplers with and without a polydimethylsiloxane (PDMS) coating and compared their surface properties and chemical uptake. We compared the chemical profiles they sampled from indoor lab and office environments using solvent-soaked wipes to extract the chemicals by wiping the lens surfaces and analyzing the wipe extracts using non-targeted screening on LC-QTOF-MS. Compared to the comparably transparent uncoated lenses, the PDMS-coated lenses were up to six times rougher in morphology. This difference, unexpectedly, did not yield significant differences in the chemical profiles measured between the PDMS-coated and uncoated polycarbonate lenses. Combined, both lens types sampled over 900 features, with diverse physico-chemical properties, annotated at varying levels of confidence. Level 2 features include phthalates and organophosphate esters commonly used as plasticizers. These promising results form the foundation for further developing the lenses as passive sampling eyewear for easily assessing inhalation exposure at the population level.
- 4 December 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (49) , 26384-26395
Introducing Eyewear Lenses as Passive Samplers for Assessing Inhalation Exposure to Airborne Chemicals
Wearable passive samplers are inexpensive tools for assessing personal exposure to diverse contaminants through a combination of exposure pathways. This versatility, however, can be a disadvantage when it is critical to assess a specific pathway. Here, we aim to develop eyewear lenses as passive samplers that can capture inhalation exposure as a primary pathway for airborne contaminants. We designed polycarbonate lens samplers with and without a polydimethylsiloxane (PDMS) coating and compared their surface properties and chemical uptake. We compared the chemical profiles they sampled from indoor lab and office environments using solvent-soaked wipes to extract the chemicals by wiping the lens surfaces and analyzing the wipe extracts using non-targeted screening on LC-QTOF-MS. Compared to the comparably transparent uncoated lenses, the PDMS-coated lenses were up to six times rougher in morphology. This difference, unexpectedly, did not yield significant differences in the chemical profiles measured between the PDMS-coated and uncoated polycarbonate lenses. Combined, both lens types sampled over 900 features, with diverse physico-chemical properties, annotated at varying levels of confidence. Level 2 features include phthalates and organophosphate esters commonly used as plasticizers. These promising results form the foundation for further developing the lenses as passive sampling eyewear for easily assessing inhalation exposure at the population level.
- Open Access
- 17 November 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (47) , 25296-25308
Shedding Light on PFAS Dark Matter Using a Novel GC-HRMS Approach
With thousands of documented perfluoroalkyl and polyfluoroalkyl substances (PFAS), novel methods are needed to comprehensively characterize these fluorinated compounds in the environment, biota, and humans. Despite being the most common approach, liquid chromatography high-resolution mass spectrometry (LC-HRMS) only covers a fraction of PFAS. To address this gap, we developed a nontargeted gas chromatography high-resolution mass spectrometry (GC-HRMS) workflow to extend coverage of the PFAS chemical space, developing and incorporating the most extensive GC HRMS PFAS libraries to date covering over 1,900 electron ionization (EI) and positive chemical ionization (PCI) predicted and experimental spectra. Five environmental and biological matrices were assessed: aqueous film forming foam (AFFF), industrial outfall, municipal leachate, residential floor dust, and human blood. A novel compound was identified (2-(perfluorohexyl)ethanethiol) in multiple AFFF formulations. A rarely monitored PFAS was additionally detected (N-methyl-N-(2-hydroxyethyl)perfluorooctanesulfonamide, N-MeFOSE) in human blood, industrial outfall, municipal leachate, and residential floor dust at high frequency and abundance. A comparison to LC-HRMS approaches for leachate and blood showed no overlap between annotated PFAS. The nontargeted workflow presented here provides essential tools to expand PFAS monitoring capabilities and identify previously undetected compounds that may pose significant health and environmental risks.
- 17 November 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (47) , 25296-25308
Open AccessShedding Light on PFAS Dark Matter Using a Novel GC-HRMS Approach
With thousands of documented perfluoroalkyl and polyfluoroalkyl substances (PFAS), novel methods are needed to comprehensively characterize these fluorinated compounds in the environment, biota, and humans. Despite being the most common approach, liquid chromatography high-resolution mass spectrometry (LC-HRMS) only covers a fraction of PFAS. To address this gap, we developed a nontargeted gas chromatography high-resolution mass spectrometry (GC-HRMS) workflow to extend coverage of the PFAS chemical space, developing and incorporating the most extensive GC HRMS PFAS libraries to date covering over 1,900 electron ionization (EI) and positive chemical ionization (PCI) predicted and experimental spectra. Five environmental and biological matrices were assessed: aqueous film forming foam (AFFF), industrial outfall, municipal leachate, residential floor dust, and human blood. A novel compound was identified (2-(perfluorohexyl)ethanethiol) in multiple AFFF formulations. A rarely monitored PFAS was additionally detected (N-methyl-N-(2-hydroxyethyl)perfluorooctanesulfonamide, N-MeFOSE) in human blood, industrial outfall, municipal leachate, and residential floor dust at high frequency and abundance. A comparison to LC-HRMS approaches for leachate and blood showed no overlap between annotated PFAS. The nontargeted workflow presented here provides essential tools to expand PFAS monitoring capabilities and identify previously undetected compounds that may pose significant health and environmental risks.
- Open Access
- 29 April 2025
- Published by Elsevier in Environmental Pollution
- Vol. 375, 126342
Assessing analyte recovery values and reporting standards for monitoring exposure to airborne semi-volatile organic compounds
- 29 April 2025
- Published by Elsevier in Environmental Pollution
- Vol. 375, 126342
Open AccessAssessing analyte recovery values and reporting standards for monitoring exposure to airborne semi-volatile organic compounds
- 20 December 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (1) , 119-131
Expanding PFAS Identification with Transformation Product Libraries: Nontargeted Analysis Reveals Biotransformation Products in Mice
Per- and polyfluoroalkyl substances (PFAS) are widely used persistent synthetic chemicals that have been linked to adverse health effects. While the behavior of PFAS has been evaluated in the environment, our understanding of reaction products in mammalian systems is limited. This study identified biological PFAS transformation products and generated mass spectral libraries to facilitate an automated search and identification. The biological transformation products of 27 PFAS, spanning 5 chemical subclasses (alcohols, sulfonamides, carboxylic acids, ethers, and esters), were evaluated following enzymatic reaction with mouse liver S9 fractions. Four major pathways were identified by liquid chromatography-high-resolution mass spectrometry: glucuronidation, sulfation, dealkylation, and oxidation. Class-based fragmentation rules and associated PFAS transformation product libraries were generated and integrated into an automated nontargeted PFAS data analysis software (FluoroMatch). Fragmentation was additionally predicted for the potential transformation products of more than 2,500 PFAS in the EPA CompTox Chemicals Dashboard PFASSTRUCTv4. Generated mass spectral libraries were validated by applying FluoroMatch to a data set of urine from aqueous film-forming foam (AFFF)-dosed mice. Toxicity predictions showed identified PFAS transformation products to be potential developmental and mutagenic toxicants. This research enables more comprehensive PFAS characterization in biological systems, which will improve the assessment of exposures and evaluation of the associated health impacts.
- 20 December 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (1) , 119-131
Expanding PFAS Identification with Transformation Product Libraries: Nontargeted Analysis Reveals Biotransformation Products in Mice
Per- and polyfluoroalkyl substances (PFAS) are widely used persistent synthetic chemicals that have been linked to adverse health effects. While the behavior of PFAS has been evaluated in the environment, our understanding of reaction products in mammalian systems is limited. This study identified biological PFAS transformation products and generated mass spectral libraries to facilitate an automated search and identification. The biological transformation products of 27 PFAS, spanning 5 chemical subclasses (alcohols, sulfonamides, carboxylic acids, ethers, and esters), were evaluated following enzymatic reaction with mouse liver S9 fractions. Four major pathways were identified by liquid chromatography-high-resolution mass spectrometry: glucuronidation, sulfation, dealkylation, and oxidation. Class-based fragmentation rules and associated PFAS transformation product libraries were generated and integrated into an automated nontargeted PFAS data analysis software (FluoroMatch). Fragmentation was additionally predicted for the potential transformation products of more than 2,500 PFAS in the EPA CompTox Chemicals Dashboard PFASSTRUCTv4. Generated mass spectral libraries were validated by applying FluoroMatch to a data set of urine from aqueous film-forming foam (AFFF)-dosed mice. Toxicity predictions showed identified PFAS transformation products to be potential developmental and mutagenic toxicants. This research enables more comprehensive PFAS characterization in biological systems, which will improve the assessment of exposures and evaluation of the associated health impacts.
- 15 October 2024
- Published by Elsevier in Chemosphere
- Vol. 366, 143544
Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method
- 15 October 2024
- Published by Elsevier in Chemosphere
- Vol. 366, 143544
Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method