Yongming Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yongming Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Lin Tang
2 shared publications- Yin Ding
State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shanxxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an, People’s Republic of China
2 shared publications - Zexu Gu
State key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an, China
2 shared publications Zhenhua Yang
State Key Laboratory of Military Stomatology, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China
2 shared publicationsBaolong Song
State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, P.R. China
1 shared publicationDong Li
1 shared publication
Latest Publications
- Open Access
- 13 November 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (11) , e0219642
Computational fluid dynamics simulation of changes in the morphology and airflow dynamics of the upper airways in OSAHS patients after treatment with oral appliances
To explore the changes of morphology and internal airflow in upper airways (UA) after the use of oral appliances (OAs) in patients with obstructive sleep apnea hypopnea syndrome (OSAHS), and investigate the mechanisms by which OAs function as a therapy for OSAHS. Eight OSAHS patients (all male, aged 37–58, mean age 46.25) underwent CT scans before and after OA use. Then, computational fluid dynamics(CFD) models were built on the base of the CT scans using Mimics and ANSYS ICEM CFD software. The internal airflow of the upper airways was simulated using ANSYS-FLUENT and the results were analyzed using ANSYS-CFD-Post. The data were analyzed to identify the most important changes of biomechanical properties between patients with and without OA intervention. Upper airway morphology and the internal airflow changes were compared using t-tests and Spearman correlation coefficient analysis. The narrowest area of upper airways was found to be located in the lower bound of velopharynx, where the volume and pressure were statistically significantly increased (P<0.05) and the air velocity was statistically significantly decreased (P<0.05) in the presence of the OA(P<0.05). After wearing OA, pharyngeal resistance was significantly decreased (P<0.05), from 290.63 to 186.25Pa/L, and the airflow resistance of the pharynx has reduced by 35.9%. The enlargement of the upper airway after wearing the OA changed its airflow dynamics, which decreased the negative pressure and resistance in narrow areas of the upper airways. Thus, the collapsibility of the upper airways was reduced and patency was sustained.
- 13 November 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (11) , e0219642
Open AccessComputational fluid dynamics simulation of changes in the morphology and airflow dynamics of the upper airways in OSAHS patients after treatment with oral appliances
To explore the changes of morphology and internal airflow in upper airways (UA) after the use of oral appliances (OAs) in patients with obstructive sleep apnea hypopnea syndrome (OSAHS), and investigate the mechanisms by which OAs function as a therapy for OSAHS. Eight OSAHS patients (all male, aged 37–58, mean age 46.25) underwent CT scans before and after OA use. Then, computational fluid dynamics(CFD) models were built on the base of the CT scans using Mimics and ANSYS ICEM CFD software. The internal airflow of the upper airways was simulated using ANSYS-FLUENT and the results were analyzed using ANSYS-CFD-Post. The data were analyzed to identify the most important changes of biomechanical properties between patients with and without OA intervention. Upper airway morphology and the internal airflow changes were compared using t-tests and Spearman correlation coefficient analysis. The narrowest area of upper airways was found to be located in the lower bound of velopharynx, where the volume and pressure were statistically significantly increased (P<0.05) and the air velocity was statistically significantly decreased (P<0.05) in the presence of the OA(P<0.05). After wearing OA, pharyngeal resistance was significantly decreased (P<0.05), from 290.63 to 186.25Pa/L, and the airflow resistance of the pharynx has reduced by 35.9%. The enlargement of the upper airway after wearing the OA changed its airflow dynamics, which decreased the negative pressure and resistance in narrow areas of the upper airways. Thus, the collapsibility of the upper airways was reduced and patency was sustained.
- Open Access
Computational fluid dynamics simulation of changes in the morphology and airflow dynamics of the upper airways in OSAHS patients after treatment with oral appliances
Objectives: To explore the changes of morphology and internal airflow in upper airways (UA) after the use of oral appliances (OAs) in patients with obstructive sleep apnea hypopnea syndrome (OSAHS), and investigate the mechanisms by which OAs function as a therapy for OSAHS. Methods: Eight OSAHS patients (all male, aged 37-58, mean age 46.25) underwent CT scans before and after OA use. Then, computational fluid dynamics(CFD) models were built on the base of the CT scans using Mimics and ANSYS ICEM CFD software. The internal airflow of the upper airways was simulated using ANSYS-FLUENT and the results were analyzed using ANSYS-CFD-Post. The data were analyzed to identify the most important changes of biomechanical properties between patients with and without OA intervention. Upper airway morphology and the internal airflow changes were compared using t -tests and Spearman correlation coefficient analysis. Results: The narrowest area of upper airways was found to be located in the lower bound of velopharynx, where the volume and pressure were statistically significantly increased (P<0.05) and the air velocity was statistically significantly decreased (P<0.05) in the presence of the OA(P<0.05). After wearing OA, pharyngeal resistance was significantly decreased (P<0.05), from 290.63 to 186.25Pa/L, and the airflow resistance of the pharynx has reduced by 35.9%. Conclusion: The enlargement of the upper airway after wearing the OA changed its airflow dynamics, which decreased the negative pressure and resistance in narrow areas of the upper airways. Thus, the collapsibility of the upper airways was reduced and patency was sustained.
Open AccessComputational fluid dynamics simulation of changes in the morphology and airflow dynamics of the upper airways in OSAHS patients after treatment with oral appliances
Objectives: To explore the changes of morphology and internal airflow in upper airways (UA) after the use of oral appliances (OAs) in patients with obstructive sleep apnea hypopnea syndrome (OSAHS), and investigate the mechanisms by which OAs function as a therapy for OSAHS. Methods: Eight OSAHS patients (all male, aged 37-58, mean age 46.25) underwent CT scans before and after OA use. Then, computational fluid dynamics(CFD) models were built on the base of the CT scans using Mimics and ANSYS ICEM CFD software. The internal airflow of the upper airways was simulated using ANSYS-FLUENT and the results were analyzed using ANSYS-CFD-Post. The data were analyzed to identify the most important changes of biomechanical properties between patients with and without OA intervention. Upper airway morphology and the internal airflow changes were compared using t -tests and Spearman correlation coefficient analysis. Results: The narrowest area of upper airways was found to be located in the lower bound of velopharynx, where the volume and pressure were statistically significantly increased (P<0.05) and the air velocity was statistically significantly decreased (P<0.05) in the presence of the OA(P<0.05). After wearing OA, pharyngeal resistance was significantly decreased (P<0.05), from 290.63 to 186.25Pa/L, and the airflow resistance of the pharynx has reduced by 35.9%. Conclusion: The enlargement of the upper airway after wearing the OA changed its airflow dynamics, which decreased the negative pressure and resistance in narrow areas of the upper airways. Thus, the collapsibility of the upper airways was reduced and patency was sustained.
- Open Access
- 22 April 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (4) , e95544
A Three Dimensional Study of Upper Airway in Adult Skeletal Class II Patients with Different Vertical Growth Patterns
The study was performed to compare the 3D pharyngeal airway dimensions in adult skeletal Class II patients with different vertical growth patterns (low, normal, and high angle) and to investigate whether the upper airway dimensions of untreated skeletal Class II adults were affected by vertical skeletal variables. Cone-beam computed tomography (CBCT) records of 64 untreated adult skeletal Class II patients (34 male and 30 female) were collected to evaluate the pharyngeal airway dimensions. Subjects were divided into three subgroups according to the GoGn-SN angle (low angle, normal angle or high angle). All subgroups were matched for sex. ANOVA and SNK - q tests were used to identify differences within and among groups (p<0.05). Coefficient of product-moment correlation (Pearson correlation coefficient) was used to analyze the association between pharyngeal airway dimensions and vertical growth patterns. The results showed that pharyngeal airway measurements were statistically significantly less (p<0.05) in high angle group as compared to normal angle or low angle group. Adult skeletal Class II subjects with vertical growth patterns have significantly narrower pharyngeal airways than those with normal or horizontal growth patterns, confirming an association between pharyngeal airway measurements and a vertical skeletal pattern.
- 22 April 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (4) , e95544
Open AccessA Three Dimensional Study of Upper Airway in Adult Skeletal Class II Patients with Different Vertical Growth Patterns
The study was performed to compare the 3D pharyngeal airway dimensions in adult skeletal Class II patients with different vertical growth patterns (low, normal, and high angle) and to investigate whether the upper airway dimensions of untreated skeletal Class II adults were affected by vertical skeletal variables. Cone-beam computed tomography (CBCT) records of 64 untreated adult skeletal Class II patients (34 male and 30 female) were collected to evaluate the pharyngeal airway dimensions. Subjects were divided into three subgroups according to the GoGn-SN angle (low angle, normal angle or high angle). All subgroups were matched for sex. ANOVA and SNK - q tests were used to identify differences within and among groups (p<0.05). Coefficient of product-moment correlation (Pearson correlation coefficient) was used to analyze the association between pharyngeal airway dimensions and vertical growth patterns. The results showed that pharyngeal airway measurements were statistically significantly less (p<0.05) in high angle group as compared to normal angle or low angle group. Adult skeletal Class II subjects with vertical growth patterns have significantly narrower pharyngeal airways than those with normal or horizontal growth patterns, confirming an association between pharyngeal airway measurements and a vertical skeletal pattern.
- 1 February 2012
- Vol. 29 (1) , 93-6
[Establishment and application of mechanical strain loading system of multi-channel cells].
Based on single-chip microcomputer, we have established a mechanical strain loading system with multi-channel to study the biological behavior of cultured cells in vitro under mechanical strain. We developed a multi-channel cell strain loading device controlled by single-chip microcomputer. We controlled the vacuum pump with vacuum chamber to make negative pressure changing periodically in the vacuum chamber. The tested cells were seeded on the surface of an elastic membrane mounted on the vacuum chamber, and could be strained or relaxed by cyclic pressure. Since the cells are attached to the surface of the membrane, they presumably experience the same deformation as that was applied to the membrane. The system was easy to carry and to operate, with deformation rate (1%-21%) and frequency (0-0. 5Hz) which could be adjusted correctly according to experimental requirement, and could compare different deformation rate of three channels at the same time. The system ran stably and completely achieved design aims, and provided a method to study the biological behavior of cultured cells attached to the surface of the elastic membrane under mechanical strain in vitro.
- 1 February 2012
- Vol. 29 (1) , 93-6
[Establishment and application of mechanical strain loading system of multi-channel cells].
Based on single-chip microcomputer, we have established a mechanical strain loading system with multi-channel to study the biological behavior of cultured cells in vitro under mechanical strain. We developed a multi-channel cell strain loading device controlled by single-chip microcomputer. We controlled the vacuum pump with vacuum chamber to make negative pressure changing periodically in the vacuum chamber. The tested cells were seeded on the surface of an elastic membrane mounted on the vacuum chamber, and could be strained or relaxed by cyclic pressure. Since the cells are attached to the surface of the membrane, they presumably experience the same deformation as that was applied to the membrane. The system was easy to carry and to operate, with deformation rate (1%-21%) and frequency (0-0. 5Hz) which could be adjusted correctly according to experimental requirement, and could compare different deformation rate of three channels at the same time. The system ran stably and completely achieved design aims, and provided a method to study the biological behavior of cultured cells attached to the surface of the elastic membrane under mechanical strain in vitro.
- Open Access
- 17 November 2010
- Published by Springer Nature in BMC Research Notes
- Vol. 3 (1) , 309
Upregulation of MMP-13 and TIMP-1 expression in response to mechanical strain in MC3T3-E1 osteoblastic cells
Mechanical strain plays a significant role in the regulation of bone matrix turnover, which is mediated in part by matrix metalloproteinase (MMP)-13 and tissue inhibitors of matrix metalloproteinase (TIMP)-1. However, little is known about the correlation between mechanical strain and osteoblastic cell activities, including extracellular matrix (ECM) metabolism. Herein, we determined the effect of different magnitudes of cyclic tensile strain (0%, 6%, 12%, and 18%) on MMP-13 and TIMP-1 mRNA and protein expression in MC3T3-E1 osteoblasts. Furthermore, we employed specific inhibitors to examine the role of distinct signal transduction pathways known to mediate cellular responses to mechanical strain.
- 17 November 2010
- Published by Springer Nature in BMC Research Notes
- Vol. 3 (1) , 309
Open AccessUpregulation of MMP-13 and TIMP-1 expression in response to mechanical strain in MC3T3-E1 osteoblastic cells
Mechanical strain plays a significant role in the regulation of bone matrix turnover, which is mediated in part by matrix metalloproteinase (MMP)-13 and tissue inhibitors of matrix metalloproteinase (TIMP)-1. However, little is known about the correlation between mechanical strain and osteoblastic cell activities, including extracellular matrix (ECM) metabolism. Herein, we determined the effect of different magnitudes of cyclic tensile strain (0%, 6%, 12%, and 18%) on MMP-13 and TIMP-1 mRNA and protein expression in MC3T3-E1 osteoblasts. Furthermore, we employed specific inhibitors to examine the role of distinct signal transduction pathways known to mediate cellular responses to mechanical strain.
- Open Access
- 29 June 2009
- Published by Elsevier in Medical Hypotheses
- Vol. 73 (4) , 594-595
Early orthodontic treatment of skeletal Class II malocclusion may be effective to prevent the potential for OSAHS and snoring
- 29 June 2009
- Published by Elsevier in Medical Hypotheses
- Vol. 73 (4) , 594-595
Open AccessEarly orthodontic treatment of skeletal Class II malocclusion may be effective to prevent the potential for OSAHS and snoring
- 1 November 2008
- Published by Elsevier in Medical Hypotheses
- Vol. 71 (5) , 762-764
Sodium β-aescin may be an effective therapeutic agent for Bell’s palsy
- 1 November 2008
- Published by Elsevier in Medical Hypotheses
- Vol. 71 (5) , 762-764
Sodium β-aescin may be an effective therapeutic agent for Bell’s palsy
- 31 October 2008
- Published by Elsevier in Medical Hypotheses
- Vol. 72 (2) , 178-179
Local delivery of osteoprotegerin may be a way of reinforcing orthodontic anchorage
- 31 October 2008
- Published by Elsevier in Medical Hypotheses
- Vol. 72 (2) , 178-179
Local delivery of osteoprotegerin may be a way of reinforcing orthodontic anchorage
- 1 June 2007
- Vol. 42 (6) , 368-72
[Effect of cyclic-tension force on the expression of osteogenesis genes in human periodontal ligament cells].
To investigate the effect of cyclic-tension force on the expression of osteogenesis genes in human periodontal ligament cells (HPDLC). HPDLC were cultured on flexible-bottomed plates and subjected to 12% elongation by strain unit at 6 cycles/min (i.e.5-s elongation and 5-s relaxation) for 48 hours in the experimental groups. GEArray Q series Human Osteogenesis Gene Array was used to identify the genes expressed in HPDLC, including growth factors and associated molecules, extracellular matrix and its associated proteins, cell adhesion molecules and housekeeping genes. The changes in the expression of 96 representative transcripts were determined by arrayed cDNA hybridization. After application of tension force, 21 genes were significantly upregulated, including 10 growth factors and associated molecules, 10 extracellular matrix and its associated protein and 1 cell adhesion molecules. Two genes were significantly downregulated, including 1 growth factors and associated molecules and 1 cell adhesion molecules. The HPDLC can differentiate into osteoblast-like cells by mechanical stretch induction through the activation of some osteogenesis genes.
- 1 June 2007
- Vol. 42 (6) , 368-72
[Effect of cyclic-tension force on the expression of osteogenesis genes in human periodontal ligament cells].
To investigate the effect of cyclic-tension force on the expression of osteogenesis genes in human periodontal ligament cells (HPDLC). HPDLC were cultured on flexible-bottomed plates and subjected to 12% elongation by strain unit at 6 cycles/min (i.e.5-s elongation and 5-s relaxation) for 48 hours in the experimental groups. GEArray Q series Human Osteogenesis Gene Array was used to identify the genes expressed in HPDLC, including growth factors and associated molecules, extracellular matrix and its associated proteins, cell adhesion molecules and housekeeping genes. The changes in the expression of 96 representative transcripts were determined by arrayed cDNA hybridization. After application of tension force, 21 genes were significantly upregulated, including 10 growth factors and associated molecules, 10 extracellular matrix and its associated protein and 1 cell adhesion molecules. Two genes were significantly downregulated, including 1 growth factors and associated molecules and 1 cell adhesion molecules. The HPDLC can differentiate into osteoblast-like cells by mechanical stretch induction through the activation of some osteogenesis genes.