HMHiroshi Murata

Hiroshi Murata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroshi Murata has a total of 157 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The influence of nanoporous silica on the evolution of prosthetic dental applications

    by Sirus Safaee, Mahdis Nesabi, Shigeaki Abe, Kae Harada, Hitomi Okazaki, Kazuhiro Yoshida, Tomoyasu Mori, Ikuya Watanabe, Hiroshi Murata


  • Open Access

    The Influence of Nanoporous Silica on the Evolution of Prosthetic Dental Applications

    by Sirus Safaee, Mahdis Nesabi, Shigeaki Abe, Kae Harada, Hitomi Okazaki, Kazuhiro Yoshida, Tomoyasu Mori, Ikuya Watanabe, Hiroshi Murata

    The field of prosthetic dentistry has witnessed significant advancements in recent decades, largely driven by innovations in materials science. Among these innovations, nanoporous silica has emerged as a transformative material with the potential to revolutionize dental applications. This manuscript explores the multifaceted effects of nanoporous silica on prosthetic dental applications, focusing on its mechanical properties, biocompatibility, and its promising role in drug delivery systems. By examining these influences, we can gain insights into the future of dental prosthetics and the integration of innovative materials to enhance patient outcomes.

  • Open Access

    Dennd2c Negatively Controls Multinucleation and Differentiation in Osteoclasts by Regulating Actin Polymerization and Protrusion Formation

    by Yu Koyanagi, Eiko Sakai, Yu Yamaguchi, Fatima Farhana, Yohsuke Taira, Kuniaki Okamoto, Hiroshi Murata, Takayuki Tsukuba

    Osteoclasts are bone-resorbing multinucleated giant cells formed by the fusion of monocyte/macrophage lineages. Various small GTPases are involved in the multinucleation and differentiation of osteoclasts. However, the roles of small GTPases regulatory molecules in osteoclast differentiation remain unclear. In the present study, we examined the role of Dennd2c, a putative guanine nucleotide exchange factor for Rab GTPases, in osteoclast differentiation. Knockdown of Dennd2c promoted osteoclast differentiation, resorption, and expression of osteoclast markers. Morphologically, Dennd2c knockdown induced the formation of larger osteoclasts with several protrusions. In contrast, overexpression of Dennd2c inhibited the multinucleation and differentiation of osteoclasts, bone resorption, and the expression of osteoclast markers. Dennd2c-overexpressing macrophages exhibited spindle-shaped mononuclear cells and long thin protrusions. Treatment of Dennd2c-overexpressing cells with the Cdc42 inhibitor ML-141 or the Rac1 inhibitor 6-thio-GTP prevented protrusion formation. Moreover, treatment of Dennd2c-overexpressing cells with the actin polymerization inhibitor latrunculin B restored multinucleated and TRAP-positive osteoclast formation. These results indicate that Dennd2c negatively regulates osteoclast differentiation and multinucleation by modulating protrusion formation in macrophages.


  • Open Access

    Rab44 Deficiency Induces Impaired Immune Responses to Nickel Allergy

    by Mayuko Noguromi, Yu Yamaguchi, Keiko Sato, Shun Oyakawa, Kuniaki Okamoto, Hiroshi Murata, Takayuki Tsukuba, Tomoko Kadowaki

    Rab44 was recently identified as an atypical Rab GTPase that possesses EF-hand and coiled-coil domains at the N-terminus, and a Rab-GTPase domain at the C-terminus. Rab44 is highly expressed in immune-related cells such as mast cells, macrophages, osteoclasts, and granulocyte-lineage cells in the bone marrow. Therefore, it is speculated that Rab44 is involved in the inflammation and differentiation of immune cells. However, little is known about the role of Rab44 in inflammation. In this study, we showed that Rab44 was upregulated during the early phase of differentiation of M1- and M2-type macrophages. Rab44-deficient mice exhibited impaired tumor necrosis factor alpha and interleukin-10 production after lipopolysaccharide (LPS) stimulation. The number of granulocytes in Rab44-deficient mice was lower, but the lymphocyte count in Rab44-deficient mice was significantly higher than that in wild-type mice after LPS stimulation. Moreover, Rab44-deficient macrophages showed impaired nickel-induced toxicity, and Rab44-deficient mice showed impaired nickel-induced hypersensitivity. Upon nickel hypersensitivity induction, Rab44-deficient mice showed different frequencies of immune cells in the blood and ears. Thus, it is likely that Rab44 is implicated in immune cell differentiation and inflammation, and Rab44 deficiency induces impaired immune responses to nickel allergies.


  • Open Access

    Effects of denture adhesives on denture retention and occlusal forces in complete denture wearers: A multicenter, randomized controlled trial

    by Tadafumi Kurogi, Hiroshi Murata, Erika Yamaguchi, Yasuhiko Kawai, Asako Suzuki, Yasuyo Koide, Suguru Kimoto, Hisatomo Kondo, Taro Nomura, Akito Tsuboi, et al.

    Purpose: This study aimed to determine the effects of denture adhesives on denture retention and occlusal force in complete denture wearers in a multicenter, randomized, parallel-group controlled trial.Methods: Two hundred edentulous patients wearing complete dentures were allocated to three groups: powder-type denture adhesive, cream-type denture adhesive, and control (saline solution). Denture adhesives and saline solution were applied to the dentures for 4 days. The retentive force of the dentures and occlusal force were measured using a force transducer occlusal force meter at baseline and after 4 days of intervention. In addition to between-group comparisons, subgroup analyses of denture retention and occlusal force were performed based on the level of difficulty of the edentulism treatment. The levels were ranked as I (easy), II, III, and IV (difficult).Results: Cream-type denture adhesives significantly improved the retentive force of the dentures (P<0.01) and occlusal force (P<0.05), with no significant differences between baseline and post-intervention forces in the powder-type denture adhesive and control groups. In within-group comparisons, cream-type denture adhesives improved both the retentive and occlusal forces at Level II (P<0.05), and powder-type denture adhesives improved the occlusal force at Level II (P<0.01).Conclusions: Application of cream-type denture adhesives effectively improves the denture retention and occlusal force in complete denture wearers with a moderate degree of difficulty during edentulism treatment.


  • Open Access

    The potential effect of ethyl alcohol elution from liner type denture adhesives on breath alcohol concentration and determination of drunk driving

    by Kazuhiro Yoshida, Hitomi Okazaki, Ryouga Osatomi, Shun Oyakawa, Mayuko Noguromi, Hiroshi Murata

  • Open Access

    Clinical efficacy of mandibular complete dentures with a resilient liner: study protocol for a multicenter randomized controlled trial

    by Katsuhiko Kimoto, Suguru Kimoto, Noriyuki Hoshi, Yusuke Sato, Yoshikazu Yoneyama, Jun Takebe, Tetsuo Ichikawa, Hiroshi Murata, Masahiro Nishimura, Shunsuke Minakuchi, et al.

    Background: During restoration of poorly fitting complete dentures (CDs) in edentulous patients, liners are used to reconstruct the concave surfaces of CDs with a new base material. These relining materials are classified into resilient liners (RLs) and non-resilient liners (NRLs), but the clinical effects of these liners and their selection criteria remain unclear. The purpose of this study is to evaluate the clinical efficacy of relining mandibular CDs using RL and NRL and to conduct a follow-up study. Methods: The study is currently being conducted at eight centers, and a parallel-group randomized controlled trial (RCT) is underway. One hundred thirty-two edentulous patients with poorly fitting mandibular CDs will be assigned to two groups based on whether they will receive RL or NRL. Participants will have an RL or NRL applied for relining their CDs using an indirect method of dynamic impressions. Data will be recorded at 1 week and 3, 6, and 12 months after denture delivery. The primary outcome will be assessment of the patients’ general satisfaction by using a 100-mm visual analog scale (VAS). Secondary outcomes will be measured as patient-reported outcomes, including food intake status and oral hygiene-related quality of life. Masticatory performance and the number of sore spots on the oral mucosa will also be recorded. Comparisons between the two groups and within-subject comparisons of pre- and post-intervention measurements will be conducted. Discussion: For dentists and prosthetic researchers in Japan, this RCT will provide information on the clinical efficacy of RL materials in comparison to RNL in CD wearers. The new evidence regarding the use of RL materials in an aging population will also be useful to dentists in other countries in their routine clinical practice. Trial registration: This clinical trial has been registered at the University Hospital Medical Information Network (UMIN) Center (UMIN000041950).

  • Effect of denture adhesives on oral moisture: A multicenter randomized controlled trial

    by Yasuhiro Nishi, Taro Nomura, Mamoru Murakami, Yasuhiko Kawai, Masahiro Nishimura, Hisatomo Kondo, Yoshihiko Ito, Akito Tsuboi, Guang Hong, Suguru Kimoto, et al.

    The purpose of this study was to investigate the effect of denture adhesives on oral moisture in a 10-center parallel randomized clinical trial. Two hundred edentulous subjects wearing complete dentures were allocated into three groups: cream-type adhesive, powder-type adhesive and control groups. The adhesives (and saline solution in the control group) were applied to the mucosal surface of the dentures for 4 days, and baseline data and data after the intervention for eight meals over 4 days were obtained. For the main outcome, oral moisture was measured with a moisture checking device. Secondary outcomes were denture satisfaction, masticatory performance, denture retention, and occlusal force. In addition to between-group and within-group comparisons of oral moisture, investigations for secondary outcomes were undertaken in subgroups classified according to the degree of oral moisture at baseline (normal subgroup and dry mouth subgroup). Intention-to-treat analysis was also performed. Between-group and within-group comparisons of oral moisture showed no significant differences. The cream-type and powder-type denture adhesives were significantly effective in the dry mouth group for denture satisfaction ratings of ability to masticate, stability, retention, and comfort of mandibular dentures (p<0.05). The masticatory performance and retentive force of the dry mouth denture adhesive using groups were significantly improved after intervention (p<0.05). The oral moisture of complete denture wearers was not influenced by the use of denture adhesives. Our findings showed that denture adhesives improved subjective denture satisfaction, masticatory performance, and retention for complete denture patients with oral dryness.


  • Pain sensitivity after low-level clenching is influenced by preloading eccentric exercise

    by Yuichi Tanabe, Tetsurou Torisu, Hiroaki Tada, Erika Yamaguchi, Hiroshi Murata, Antoon De Laat, Peter Svensson

    Purpose To examine the effect of preloading eccentric exercise on pain sensitivity in healthy volunteers. Methods In 20 healthy volunteers, pain-related sensations (6 items: pain, unpleasantness, fatigue, stiffness, tension, and soreness during maximum biting), and pain intensities induced by repeated electrical stimuli on the masseter and the hand palm were evaluated using a visual analog scale (VAS) of 0–100 mm. Eccentric exercise (6 min—test) or gum chewing (6 min—control) was used as preloading exercise to evaluate the effect on pain sensitivities before and after low-level clenching (15 min) performed 2 days after the preloading exercise. Results Eccentric exercise induced only low levels of pain-related sensations 2 days later. However, the time course of temporal summation induced by four repeated electrical stimuli on the masseter was influenced by the type of preloading exercise, i.e., temporal summation increased after the low-level clenching (P = 0.016) when preloading was done by the eccentric exercise, while no significant change was observed when preloading was done by the gum chewing. Conclusions Eccentric exercise may facilitate pain sensitivity induced by subsequent low-level clenching via the central nervous system. In addition, it was demonstrated that pain sensitivity after the low-level clenching could be influenced by the type of preloading exercise. These experimental results may suggest that eccentric exercise could act as one of the triggering factors in the mechanism by which tooth clenching leads to a chronic pain condition in susceptible individuals.


  • Evaluation of viscoelastic properties, hardness, and glass transition temperature of soft denture liners and tissue conditioner

    by Yukiro Kitagawa, Kazuhiro Yoshida, Kazuma Takase, Alireza Valanezhad, Ikuya Watanabe, Ken Kojio, Hiroshi Murata

    Soft denture liners and tissue conditioners are widely used for the denture patients to cushion masticatory force and condition abused tissues, respectively. This study assessed methods for the evaluation of the viscoelasticity and glass transition temperature (Tg) of the silicone permanent soft liner, acrylic permanent soft liner, and tissue conditioner. Three rheological parameters of storage modulus (E′), loss modulus (E′′), and loss tangent (\(\tan \delta\)), Tg, and hardness were determined using dynamic mechanical analysis (DMA), differential scanning calorimetry (DSC), and the Shore A0 hardness test. Five specimens were measured for each material. The time–temperature superposition principle was applied to produce master curves of E′, E′′, and \(\tan \delta\) for the tested materials at a reference temperature of 37 °C. The acrylic permanent soft liner and tissue conditioner exhibited viscoelastic behavior and sensitivity to frequency, especially at lower frequencies. The silicone permanent soft liner showed elastic behavior and was frequency-independent. Tg for the acrylic permanent soft liner was higher than that for the tissue conditioner, which in turn was higher than that for the silicone permanent soft liner for both DMA and DSC. In DMA, a higher frequency led to higher Tg values. A positive linear relationship was found between Shore A0 hardness and E′ values, but not E′′ and \(\tan \delta\) values. Shore hardness reflects elasticity, but not viscosity. The results of the present study can be used to improve methods for evaluating the viscoelasticity and Tg of soft denture liners and tissue conditioners.