Mohamed Bouazaoui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohamed Bouazaoui has a total of 155 co-authors. Here are the top co-authors by number of shared publications:
- Hicham El Hamzaoui
CNRS, UMR 8523-PhLAM-Physique des Lasers Atomes et Molcules, Univ. Lille, Lille, France
22 shared publications - Bruno Capoen
CNRS, UMR 8523 Physique des Laser Atomes et Molcules (PhLAM), Universit de Lille, Lille, France
18 shared publications - Adriana Morana
Université Jean Monnet Saint-Etienne
11 shared publications - Sylvain Girard
Université Jean Monnet Saint-Etienne
11 shared publications - Aziz Boukenter
Laboratoire Hubert Curien, UMR CNRS 5516, Université Jean Monnet, 42000 Saint-Etienne, France
10 shared publications - Youcef Ouerdane
Laboratoire Hubert Curien, UMR CNRS 5516, Université Jean Monnet, 42000 Saint-Etienne, France
10 shared publications
Latest Publications
- 12 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
Toward Accurate Monitoring of 14 MeV Neutron Flux: Investigating a 6 Lithium Glass Scintillator
We tested the capability of a cerium activated lithium silicate glass scintillator, typically employed for thermal neutron monitoring, to act as a 14 MeV neutrons flux and fluence monitor. A flux correlation of a fibered online sensor based on radioluminescence phenomenon is obtained from a first irradiation run and subsequently validated on a second dataset, within a 17% agreement. Cumulative dose effects are investigated under X-rays, revealing a significant contribution from radiation-induced attenuation, which reduces radiation sensitivity in preirradiated sensors, unlike what has been observed in cerium-doped fibers. Geant4 simulations provide an overview of potential applications in choosing between a Ce-doped fiber or a lithium-based scintillator as dosimeter. Finally, a preliminary spectroscopic study highlights a characteristic photoluminescence lifetime of 38 ns associated with the emission peak centered at 395 nm. The comparison of emission spectra under different excitations further suggests the involvement of additional ionization processes requiring deeper investigation.
- 12 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
Toward Accurate Monitoring of 14 MeV Neutron Flux: Investigating a 6 Lithium Glass Scintillator
We tested the capability of a cerium activated lithium silicate glass scintillator, typically employed for thermal neutron monitoring, to act as a 14 MeV neutrons flux and fluence monitor. A flux correlation of a fibered online sensor based on radioluminescence phenomenon is obtained from a first irradiation run and subsequently validated on a second dataset, within a 17% agreement. Cumulative dose effects are investigated under X-rays, revealing a significant contribution from radiation-induced attenuation, which reduces radiation sensitivity in preirradiated sensors, unlike what has been observed in cerium-doped fibers. Geant4 simulations provide an overview of potential applications in choosing between a Ce-doped fiber or a lithium-based scintillator as dosimeter. Finally, a preliminary spectroscopic study highlights a characteristic photoluminescence lifetime of 38 ns associated with the emission peak centered at 395 nm. The comparison of emission spectra under different excitations further suggests the involvement of additional ionization processes requiring deeper investigation.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2306-2312
Optimization of Radioluminescent Fiber Dosimeter for Space Missions
This study investigates the impact of pre-irradiation on radiation-induced luminescence (RIL) based optical fiber dosimeters and compares the performances of Copper (Cu)-, Cerium (Ce)- and Cu/Ce-co-doped silica optical fibers under ionizing radiations. A total of 112 optical fiber probes were tested under 40 keV mean energy fluence X-rays over a wide dose rate range (5 mGy/s to 1.5 Gy/s) after different levels of pre-irradiation treatments (up to 2 MGy). Spectral analyses were also conducted to study the impact of total ionizing dose (TID) on spectral emission profiles. Results show that the pre-irradiation improves the RIL linearity with the dose rate, particularly for Cu-doped optical fibers. Cu/Ce-co-doped optical fibers show higher radiation sensitivity but also a greater probe-to-probe dispersion. However, this latter remains below 30% for all the investigated samples. Normalized RIL spectra show that Ce-doped optical fibers maintain a stable emission spectrum with increasing dose, while Cu- and Cu/Ce-co-doped optical fibers show spectral changes, through a blue shift of the RIL peak. These results underline the benefit of pre-irradiating the radioluminescent optical fibers to optimize their RIL dosimetry performances. For the most challenging applications, an individual calibration remains today needed for accurate dosimetry.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2306-2312
Optimization of Radioluminescent Fiber Dosimeter for Space Missions
This study investigates the impact of pre-irradiation on radiation-induced luminescence (RIL) based optical fiber dosimeters and compares the performances of Copper (Cu)-, Cerium (Ce)- and Cu/Ce-co-doped silica optical fibers under ionizing radiations. A total of 112 optical fiber probes were tested under 40 keV mean energy fluence X-rays over a wide dose rate range (5 mGy/s to 1.5 Gy/s) after different levels of pre-irradiation treatments (up to 2 MGy). Spectral analyses were also conducted to study the impact of total ionizing dose (TID) on spectral emission profiles. Results show that the pre-irradiation improves the RIL linearity with the dose rate, particularly for Cu-doped optical fibers. Cu/Ce-co-doped optical fibers show higher radiation sensitivity but also a greater probe-to-probe dispersion. However, this latter remains below 30% for all the investigated samples. Normalized RIL spectra show that Ce-doped optical fibers maintain a stable emission spectrum with increasing dose, while Cu- and Cu/Ce-co-doped optical fibers show spectral changes, through a blue shift of the RIL peak. These results underline the benefit of pre-irradiating the radioluminescent optical fibers to optimize their RIL dosimetry performances. For the most challenging applications, an individual calibration remains today needed for accurate dosimetry.
- 4 February 2026
- Published by Wiley in Physica Status Solidi (a)
- Vol. 223 (3)
Impact of the Numerical Aperture on the Dosimetry Performances of Low‐OH Pure Silica‐Core Optical Fibers
This study investigates the influence of pre‐irradiation and numerical aperture (NA) on radiation‐induced luminescence (RIL) and radiation‐induced attenuation (RIA) of pure silica core (PSC) multimode (MM) optical fibers (OFs) under steady state X‐rays (40 keV mean energy‐fluence). The RIL properties of MM PSC OFs with identical core compositions and geometries but having different NAs (0.12, 0.15, and 0.22) have been characterized as well as the influence of pre‐irradiation doses at 250 kGy, 1 and 2 MGy. RIL were measured under dose rates varying from 40 mGy(SiO 2 )/s to 1.1 Gy/s. RIL spectral analysis shows two main emission bands correlated to Oxygen Deficient Centers (ODC(II), ∼460 nm) and NonBridging Oxygen Hole Centers (NBOHC, ∼650 nm). The spatial distribution of NBOHC, confined in the fiber core, has been measured through confocal photoluminescence microscopy. RIA was carried out up to a total ionizing dose (TID) up to 200 kGy and no major effect of NAs was observed. RIL intensity increases with both NA and pre‐irradiation dose due to defect generation within the PSC MM optical fiber. Based on these results, the potential of these PSC MM fibers to serve as radiation sensitive probes or as transport fibers for dosimetry systems is discussed.
- 4 February 2026
- Published by Wiley in Physica Status Solidi (a)
- Vol. 223 (3)
Impact of the Numerical Aperture on the Dosimetry Performances of Low‐OH Pure Silica‐Core Optical Fibers
This study investigates the influence of pre‐irradiation and numerical aperture (NA) on radiation‐induced luminescence (RIL) and radiation‐induced attenuation (RIA) of pure silica core (PSC) multimode (MM) optical fibers (OFs) under steady state X‐rays (40 keV mean energy‐fluence). The RIL properties of MM PSC OFs with identical core compositions and geometries but having different NAs (0.12, 0.15, and 0.22) have been characterized as well as the influence of pre‐irradiation doses at 250 kGy, 1 and 2 MGy. RIL were measured under dose rates varying from 40 mGy(SiO 2 )/s to 1.1 Gy/s. RIL spectral analysis shows two main emission bands correlated to Oxygen Deficient Centers (ODC(II), ∼460 nm) and NonBridging Oxygen Hole Centers (NBOHC, ∼650 nm). The spatial distribution of NBOHC, confined in the fiber core, has been measured through confocal photoluminescence microscopy. RIA was carried out up to a total ionizing dose (TID) up to 200 kGy and no major effect of NAs was observed. RIL intensity increases with both NA and pre‐irradiation dose due to defect generation within the PSC MM optical fiber. Based on these results, the potential of these PSC MM fibers to serve as radiation sensitive probes or as transport fibers for dosimetry systems is discussed.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (7) , 2059-2065
Pre-Irradiation Influence on Proton Radioluminescence Responses of Sol-Gel Optical Fibers
We measured the radiation induced luminescence (RIL) of sol-gel made silica-based optical fibers under protons with energy varying between ~27 and 63 MeV. We compared simultaneously the responses of a pristine (i.e. not irradiated) sample and one pre-irradiated under X-rays up to 250 kGy of the different fiber types (cerium, copper, cerium/terbium co-doped fibers). The obtained results highlight better performances for pre-irradiated samples thanks to the progressive deep traps filling and reduction of the Bright Burn Effect. The dose deposited by the protons and the dose rate range within the fiber sensitive volumes are obtained through Monte Carlo simulations. We observed a good linearity of the RIL versus the dose rate in the 1.5-12 Gy(SiO2)/s range and for the different tested proton energies. In particular, no energy dependence is noticed regarding the RIL, within a 5% maximum. All these characteristics are especially important for proton therapy, where the linear energy transfer changes along the Bragg peak during the tumor treatment. Sol-gel silica-based optical fibers constitute promising solutions for proton flux (or dose rate) monitoring during treatments, providing high spatial resolution.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (7) , 2059-2065
Pre-Irradiation Influence on Proton Radioluminescence Responses of Sol-Gel Optical Fibers
We measured the radiation induced luminescence (RIL) of sol-gel made silica-based optical fibers under protons with energy varying between ~27 and 63 MeV. We compared simultaneously the responses of a pristine (i.e. not irradiated) sample and one pre-irradiated under X-rays up to 250 kGy of the different fiber types (cerium, copper, cerium/terbium co-doped fibers). The obtained results highlight better performances for pre-irradiated samples thanks to the progressive deep traps filling and reduction of the Bright Burn Effect. The dose deposited by the protons and the dose rate range within the fiber sensitive volumes are obtained through Monte Carlo simulations. We observed a good linearity of the RIL versus the dose rate in the 1.5-12 Gy(SiO2)/s range and for the different tested proton energies. In particular, no energy dependence is noticed regarding the RIL, within a 5% maximum. All these characteristics are especially important for proton therapy, where the linear energy transfer changes along the Bragg peak during the tumor treatment. Sol-gel silica-based optical fibers constitute promising solutions for proton flux (or dose rate) monitoring during treatments, providing high spatial resolution.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 15065-15070
Temperature Impact on a Radioluminescent Silica-Based Optical Fiber Dosimeter for Space Applications
Dosimetry holds significant importance across various applications such as radiotherapy, nuclear power plants, accelerators, and space research domains. Indeed, ensuring accurate dosimetry calibration is crucial for radioprotection or operations. In the context of challenging environments such as space, temperature calibration of radiation sensors plays an important role in ensuring their performances. This article discusses the temperature calibration of a cerium (Ce)-doped silica (SiO2)-based Optical Fiber (OF). The calibration covers a temperature range, during 40 keV X-rays irradiation, varying from - 80 °C to +100 °C, meeting the requirements for space applications and allowing for the determination of the temperature dependence of the Radiation Induced Luminescence (RIL). The tests were repeated on three identical 1 cm-long Ce-doped OFs. Our experiments reveal a temperature dependence of the RIL, particularly noticeable at low temperatures, where RIL decreases significantly as the temperature drops. Consequently, a temperature sensitivity curve for RIL is proposed, to calibrate the variations in RIL responses across the investigated temperature range. However, in complex operation conditions, with varying dose rates and temperatures, other phenomena could alter the detector performances, in particular the thermoluminescence observed during strong positive temperature gradients. This work contributes to highlight the potential of RIL-based sensors under varying temperature conditions, crucial for improving the reliability and accuracy, especially in a harsh environment as space.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 15065-15070
Temperature Impact on a Radioluminescent Silica-Based Optical Fiber Dosimeter for Space Applications
Dosimetry holds significant importance across various applications such as radiotherapy, nuclear power plants, accelerators, and space research domains. Indeed, ensuring accurate dosimetry calibration is crucial for radioprotection or operations. In the context of challenging environments such as space, temperature calibration of radiation sensors plays an important role in ensuring their performances. This article discusses the temperature calibration of a cerium (Ce)-doped silica (SiO2)-based Optical Fiber (OF). The calibration covers a temperature range, during 40 keV X-rays irradiation, varying from - 80 °C to +100 °C, meeting the requirements for space applications and allowing for the determination of the temperature dependence of the Radiation Induced Luminescence (RIL). The tests were repeated on three identical 1 cm-long Ce-doped OFs. Our experiments reveal a temperature dependence of the RIL, particularly noticeable at low temperatures, where RIL decreases significantly as the temperature drops. Consequently, a temperature sensitivity curve for RIL is proposed, to calibrate the variations in RIL responses across the investigated temperature range. However, in complex operation conditions, with varying dose rates and temperatures, other phenomena could alter the detector performances, in particular the thermoluminescence observed during strong positive temperature gradients. This work contributes to highlight the potential of RIL-based sensors under varying temperature conditions, crucial for improving the reliability and accuracy, especially in a harsh environment as space.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1130-1136
Sensitivity Enhancement of Tapered Cerium-Doped Optical Fibers for Dosimetry Applications
We compared the 40 keV X-ray radiation-induced luminescence of a Cerium-doped sol-gel optical fiber (doped core diameter of 52 μm) and that of its tapered versions at differently reduced sensitive volumes, with the doped core diameter ranging from 25 μm down to 4.2 μm. Our results showed that the material radiation sensitivity, normalized to the sensitive volume, increases when decreasing the core size through the tapering process. This opens the way to advanced microscale fiber-based dosimetry, as it becomes possible to design very small tapered optical fibers with still sufficiently large sensitivity to monitor dose rates from 0.5 to 170 mGy(SiO2)/s. The combined effects of pre-irradiation and fiber tapering processes on its radiation induced luminescence properties were also investigated, providing useful information for the physical explanation of the increased radioluminescence resulting from the tapering process.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1130-1136
Sensitivity Enhancement of Tapered Cerium-Doped Optical Fibers for Dosimetry Applications
We compared the 40 keV X-ray radiation-induced luminescence of a Cerium-doped sol-gel optical fiber (doped core diameter of 52 μm) and that of its tapered versions at differently reduced sensitive volumes, with the doped core diameter ranging from 25 μm down to 4.2 μm. Our results showed that the material radiation sensitivity, normalized to the sensitive volume, increases when decreasing the core size through the tapering process. This opens the way to advanced microscale fiber-based dosimetry, as it becomes possible to design very small tapered optical fibers with still sufficiently large sensitivity to monitor dose rates from 0.5 to 170 mGy(SiO2)/s. The combined effects of pre-irradiation and fiber tapering processes on its radiation induced luminescence properties were also investigated, providing useful information for the physical explanation of the increased radioluminescence resulting from the tapering process.
- 12 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (10) , 2280-2286
Temperature Effect on the Radioluminescence of Differently Doped Silica-Based Optical Fibers
We evaluate the temperature effect on the X-ray Radiation Induced Luminescence (RIL) of differently doped silica fibres obtained via the sol-gel route. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. However, several radiation environments, such as space and particle accelerators, require also a careful assessment of the temperature effect on these properties exploited for dosimetry. With this aim, we characterize their RIL efficiency and spectral dependence at several irradiation temperatures. We demonstrate that all the investigated materials present a non-negligible temperature dependence of the RIL in the range -120 °C to 80 °C. The temperature effect on the RIL signal is still compensable via calibration and temperature monitoring.
- 12 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (10) , 2280-2286
Temperature Effect on the Radioluminescence of Differently Doped Silica-Based Optical Fibers
We evaluate the temperature effect on the X-ray Radiation Induced Luminescence (RIL) of differently doped silica fibres obtained via the sol-gel route. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. However, several radiation environments, such as space and particle accelerators, require also a careful assessment of the temperature effect on these properties exploited for dosimetry. With this aim, we characterize their RIL efficiency and spectral dependence at several irradiation temperatures. We demonstrate that all the investigated materials present a non-negligible temperature dependence of the RIL in the range -120 °C to 80 °C. The temperature effect on the RIL signal is still compensable via calibration and temperature monitoring.
- 22 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (5) , 1168-1174
63-MeV Proton Beam Profile Monitoring With Radioluminescent Ce-Doped Optical Fiber Sensor
We investigated the potential of an optical material (Ce-doped silica rod of ~0.5 mm in diameter and ~1 cm in length) developed by sol-gel process to perform in situ proton beam profile measurement through the monitoring of its visible radioluminescence features peaking around 480 nm. Various test configurations (collimator sizes and varying distances from the collimators) have been performed to assess the sensor performances at the TRIUMF facility in Vancouver offering a 63 MeV proton beam. The obtained results are promising, showing their potential to characterize the flux and beam profile at this facility offering radiation testing capabilities or medical treatments. The reported performances could be improved by pre-irradiating the probe sample to reduce the observed slight Bright Burn effect on the quality of the profile measurements. These results open the way to most advanced sensors architecture such as ribbons of optical fibers drawn from this sol-gel rod, to acquire in one step the complete beam profile.
- 22 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (5) , 1168-1174
63-MeV Proton Beam Profile Monitoring With Radioluminescent Ce-Doped Optical Fiber Sensor
We investigated the potential of an optical material (Ce-doped silica rod of ~0.5 mm in diameter and ~1 cm in length) developed by sol-gel process to perform in situ proton beam profile measurement through the monitoring of its visible radioluminescence features peaking around 480 nm. Various test configurations (collimator sizes and varying distances from the collimators) have been performed to assess the sensor performances at the TRIUMF facility in Vancouver offering a 63 MeV proton beam. The obtained results are promising, showing their potential to characterize the flux and beam profile at this facility offering radiation testing capabilities or medical treatments. The reported performances could be improved by pre-irradiating the probe sample to reduce the observed slight Bright Burn effect on the quality of the profile measurements. These results open the way to most advanced sensors architecture such as ribbons of optical fibers drawn from this sol-gel rod, to acquire in one step the complete beam profile.