SAStefan Asbach

Stefan Asbach

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Asbach has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Christoph Bode

    Cardiology and Angiology I Heart Center Freiburg University Freiburg Germany

    10 shared publications
  • Fabienne Schluermann

    Cardiology and Angiology I Heart Center Freiburg University Freiburg Germany

    5 shared publications
  • Juergen Biermann

    Cardiology and Angiology I, Heart Center, Freiburg University, Freiburg, Germany

    4 shared publications
  • Luca Trolese

    Department of Cardiology and Angiology I, University Heart Center, Hugstetter Str. 55, 79106, Freiburg, Germany

    4 shared publications
  • Maximilian Hartmann

    Cardiology and Angiology I, Heart Center, Freiburg University, Freiburg, Germany

    4 shared publications
  • Corinna Lang

    Cardiology and Angiology I Heart Center Freiburg University Freiburg Germany

    2 shared publications

Latest Publications

  • Open Access

    Apparent pacemaker dysfunction during peptide receptor radionuclide therapy for neuroendocrine tumor

    by Stefan Asbach, Fabienne Schluermann, Juri Ruf, Christoph Bode, Corinna Lang

    Key Clinical Message: This case is a reminder not to overlook rare causes of electrolyte shifts, which may cause reversible changes in pacemaker pacing thresholds.


  • Automated lesion annotation during pulmonary vein isolation: influence on acute isolation rates and lesion characteristics

    by Stefan Asbach, Corinna Lang, Luca Trolese, Christoph Bode, Fabienne Schluermann

    Recovery of pulmonary vein (PV) conduction is a common mechanism of atrial fibrillation recurrence after PV isolation (PVI), underscoring the need for durable lesion formation. We aimed to evaluate the utility of an automated lesion annotation algorithm (ALAA) on acute isolation rates and resulting lesion characteristics. Fifty patients underwent PVI using a contact force (CF) sensing catheter and ALAA. Single antral circles around ipsilateral PVs were performed with ALAA-1 settings including catheter stability (range of motion ≤2 mm, duration >10 s). Target CF was 10–20 g but not part of ALAA-1 settings. If PV conduction persisted after circle completion, force over time was added to automated settings (ALAA-2). Emerging gaps were subsequently ablated, followed by re-assessment for PVI. ALAA-1 isolated 70 % of the left and 78 % of the right PVs using 756.3 ± 212.3 s (left) and 737.1 ± 145.9 s (right) of energy delivery. ALAA-2 settings identified 29 gaps in previously unisolated PVs, closure significantly increased isolation rates to 88 % of the left and 96 % of the right PVs with additional 325.4 ± 354.1 s (left) and 266.8 ± 279.5 s (right) of energy delivery (p = 0.001). Lesion characteristics significantly differed between ALAA-1 (n = 3521 lesions) and ALAA-2 (n = 3037 lesions) settings, and between isolated and non-isolated PV segments, particularly with respect to CF. Interlesion distances with ALAA-2 were significantly longer in the left superior, left superior-anterior, and right superior-posterior segments when compared to ALAA-1. Settings of an ALAA affect lesion characteristics reveal areas of insufficient lesion formation and influence acute effectiveness of PVI. Combination of CF and stability shows superior performance over stability alone.


  • Impact of the Right Ventricular Lead Position on Clinical End Points in CRT Recipients—A Subanalysis of the Multicenter Randomized SPICE Trial

    by Stefan Asbach, Carsten Lennerz, Verena Semmler, Christian Grebmer, Ulrich Solzbach, Axel Kloppe, Norbert Klein, Istvan Szendey, George Andrikopoulos, Stylianos Tzeis, et al.

    Background: The impact of right ventricular (RV) lead location on clinical end points in patients undergoing cardiac resynchronization therapy (CRT) is unclear. We evaluated the impact of different RV lead locations on clinical outcome in CRT patients enrolled in the Septal Positioning of ventricular implantable cardioverter‐defibrillator (ICD) Electrodes (SPICE) trial, which randomized recipients of implantable cardioverter defibrillators to apical versus midseptal RV lead positioning.Methods: Ninety‐eight CRT recipients were included in the multicenter SPICE trial and followed for 12 months: Fifty‐three patients were randomized to receive an apical (A) and 45 to receive a midseptal (S) lead position. We compared echocardiographical and electrocardiographical parameters and outcome.Results: Echocardiographic response with respect to improvement of left ventricular ejection fraction (A: +15.8 ± 14.6%, S: +9.7 ± 12.6%, P = 0.156) and reduction of left ventricular end‐diastolic diameter (A: −4.2 ± 10.7 mm, S: −7.5 ± 10.7 mm, P = 0.141) was comparable in apical and midseptal groups. Paced QRS width neither differed at prehospital discharge (A: 129 ± 21 ms, S: 135 ± 21 ms, P = 0.133) nor at 12‐month follow‐up (A: 131 ± 23 ms, S: 134 ± 28 ms, P = 0.620). No differences were found with respect to the risk of ventricular tachyarrhythmia or ICD therapy. Septal RV lead position, however, was associated with a significant longer time to a first heart failure event (P = 0.040) and a longer survival time (P = 0.019).Conclusions: In CRT recipients, midseptal RV lead position was not superior with respect to improvement of echocardiographic parameters or paced QRS width. It did not predispose to ventricular arrhythmias or ICD therapy. The finding that midseptal lead position was associated with a longer time to first heart failure event and a longer survival time deserves further investigation.


  • Pulmonary vein stenosis after pulmonary vein isolation using duty-cycled unipolar/bipolar radiofrequency ablation guided by intracardiac echocardiography

    by Stefan Asbach, Fabienne Schluermann, Luca Trolese, Mathias Langer, Christoph Bode, Tobias Krauss

    Concerning rates of pulmonary vein (PV) stenosis were reported following PV isolation (PVI) with a circular pulmonary vein ablation catheter (PVAC). As this may depend on intraprocedural imaging, we evaluated the incidence of PV stenosis in patients undergoing PVAC-PVI with continuous surveillance by intracardiac echocardiography (ICE).


  • Open Access

    In vivocontact force measurements and correlation with left atrial anatomy during catheter ablation of atrial fibrillation

    by Fabienne Schluermann, Tobias Krauss, Juergen Biermann, Maximilian Hartmann, Luca Trolese, Gregor Pache, Christoph Bode, Stefan Asbach

    Lesion formation during catheter ablation crucially depends on catheter-tissue contact. We sought to evaluate the impact of anatomical characteristics of the left atrium (LA) and the pulmonary veins (PVs) on contact force (CF) measurements. An anatomical map of the LA was obtained in 25 patients prior to catheter ablation of atrial fibrillation. Contact force (operator blinded) and local bipolar electrogram amplitudes (EGM) were measured in eight pre-defined segments around the PVs. After unblinding, points with low CF (≤5 g) were corrected to CF >5 g, and the distance between points was measured. In a pre-procedural computed tomography of the heart, LA volume as well as sizes and circumferences of the PV ostia were measured and correlated to CF measurements. Four hundred and twenty-six points in eight pre-defined LA locations were assessed. Low CF (P = ns). The mean CF at the left PVs was significantly lower than at the right PVs (7.91 ± 3.74 vs. 13.95 ± 6.34 g, P < 0.001), with the lowest CF anterior to the left PVs (5.2 ± 3.6 g). Contact force measurements did not correlate to LA volume, size, and circumference of the PVs. Contact force during LA mapping significantly differs according to the location within the LA. These differences are independent of LA volume and anatomy of the PV ostia.


  • Author's reply

    by Luca Trolese, Christoph Bode, Stefan Asbach

    We very much appreciate the interest in our studies1,2 performed on haemodynamic effects of vector selection of quadripolar electrodes in cardiac resynchronization therapy (CRT). Currently,3 vector selection in clinical practice is mainly based on technical issues, i.e. optimization of pacing thresholds and avoidance of phrenic nerve capture. Solely based on this, with more options to effectively deliver biventricularpacing,4 incremental benefits of CRT may be expected. The variety of available left ventricular pacing configurations (LVPCs) however also prompts the search for the optimal LVPC from a haemodynamic viewpoint. After we could show that selection …


  • Haemodynamic vector personalization of a quadripolar left ventricular lead used for cardiac resynchronization therapy: use of surface electrocardiogram and interventricular time delays

    by Luca Trolese, Juergen Biermann, Maximilian Hartmann, Fabienne Schluermann, Thomas S. Faber, Christoph Bode, Stefan Asbach

    Aims The choice of left ventricular pacing configurations (LVPCs) of quadripolar leads used for cardiac resynchronization therapy (CRT) affects haemodynamic response and thus may be a tool for device optimization. The value of surface electrocardiograms and interventricular time delays (IVDs) for optimization is unknown. Methods and results Sixteen patients implanted with a CRT device with a quadripolar LV lead underwent invasive testing of LV d P /d t . QRS durations at baseline (bl) and during biventricular pacing (biv) were measured using different LVPCs (total of 141 LVPCs; 8.8 per patient). Variations in QRS duration during biv were calculated for each patient (ΔQRS) and, when compared with intrinsic QRS duration, for all LVPCs (ΔQRSLVPC). Interventricular time delays between the poles of the LV lead were obtained from intracardiac electrograms. ΔIVD was calculated as IVDmax − IVDmin. Parameters were correlated with LV d P /d t . ΔQRS and ΔQRSLVPC both significantly correlated with LV d P /d t ( P < 0.01). Correlation was found for patients with ischaemic ( P < 0.001) and non-ischaemic cardiomyopathy ( P < 0.05), and for patients with bl QRS duration >168 ms ( P < 0.001), but not <168 ms ( P = ns). The LVPC with shortest QRS duration also yielded maximal LV d P /d t in 6 of 16 patients (37.5%), and was equal or better in LV d P /d t in 12 of 16 patients (75%). ΔIVD neither correlated with ΔQRS nor ΔLV d P /d t . Conclusion ΔQRS predicts the maximal value of vector personalization in the individual. Reductions in QRS width, but not IVDs, correlate with acute haemodynamic response. Intraindividually, in 75% of patients, the LVPC with the shortest QRS duration gives equal or superior haemodynamic results when compared with the LVPC with longest QRS duration.


  • Remote ICD-monitoring in detection and follow-up of triggers of idiopathic ventricular fibrillation: Implications for the clinical management of IVF patients

    by Johannes Steinfurt, Jürgen Biermann, Maximilian Hartmann, Fabienne Schlürmann, Katja E. Odening, Christoph Bode, Stefan Asbach


  • Open Access

    Vector Selection of a Quadripolar Left Ventricular Pacing Lead Affects Acute Hemodynamic Response to Cardiac Resynchronization Therapy: A Randomized Cross-Over Trial

    by Stefan Asbach, Maximilian Hartmann, Tobias Wengenmayer, Erika Graf, Christoph Bode, Juergen Biermann

    A suboptimal left ventricular (LV) pacing site may account for non-responsiveness of patients to cardiac resynchronization therapy (CRT). The vector selection of a novel quadripolar LV pacing lead, which was mainly developed to overcome technical issues with stimulation thresholds and phrenic nerve capture, may affect hemodynamic response, and was therefore assessed in this study. (German Clinical Trials Register DRKS00000573). Hemodynamic effects of a total of 145 LVPCs (9.1 per patient) of CRT devices with a quadripolar LV lead (Quartet™, St. Jude Medical) were assessed in 16/20 consecutive patients by invasive measurement of LV+dP/dtmax at an invasively optimized AV-interval in random order. Optimal (worst) LVPCs per patient were identified as those with maximal (minimal) %change in LV+dP/dtmax (%ΔLV+dP/dtmax) as compared to a preceding baseline. LV+dP/dtmax significantly increased in all 145 LVPCs (pmax by 31.3% (95% CI 24%–39%) in the optimal, by 21.3% (95% CI: 15%–27%) in the worst and by 28.2% (95% CI: 21%–36%) in a default distal LVPC. This resulted in an absolute additional acute increase in %ΔLV+dP/dtmax of 10.0% (95% CI: 7%–13%) of the optimal when compared to the worst (pmax when comparing optimal and worst vectors.


  • Open Access

    European survey on efficacy and safety of duty-cycled radiofrequency ablation for atrial fibrillation

    by C. Scharf, G.A. Ng, M. Wieczorek, T. Deneke, S.S. Furniss, St. Murray, Ph. Debruyne, N. Hobson, R.F. Berntsen, M.A. Schneider, et al.

    Duty-cycled radiofrequency ablation (RFA) has been used for atrial fibrillation (AF) for around 5 years, but large-scale data are scarce. The purpose of this survey was to report the outcome of the technique. A survey was conducted among 20 centres from seven European countries including 2748 patients (2128 with paroxysmal and 620 with persistent AF). In paroxysmal AF an overall success rate of 82% [median 80%, interquartile range (IQR) 74–90%], a first procedure success rate of 72% [median 74% (IQR 59–83%)], and a success of antiarrhythmic medication of 59% [median 60% (IQR 39–72%)] was reported. In persistent AF, success rates were significantly lower with 70% [median 74% (IQR 60–92%)]; P = 0.05) as well as the first procedure success rate of 58% [median 55% (IQR 47–81%)]; P = 0.001). The overall success rate was similar among higher and lower volume centres and were not dependent on the duration of experience with duty-cycled RFA (r = −0.08, P = 0.72). Complications were observed in 108 (3.9%) patients, including 31 (1.1%) with symptomatic transient ischaemic attack or stroke, which had the same incidence in paroxysmal and persistent AF (1.1 vs. 1.1%) and was unrelated to the case load (r = 0.24, P = 0.15), bridging anticoagulation to low molecular heparin, routine administration of heparin over the long sheath, whether a transoesophageal echocardiogram was performed in every patient or not and average procedure times. Duty-cycled RFA has a self-reported success and complication rate similar to conventional RFA. After technical modifications a prospective registry with controlled data monitoring should be conducted to assess outcome.