Lin Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lin Wu has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Qu-Ming Zhao
Cardiovascular Center, Children's Hospital of Fudan University , Shanghai, 201102
3 shared publicationsFeng Wang
Department of Cardiology, Cardiovascular Center, Children's Hospital of Fudan University, Shanghai 201102, P.R. China
2 shared publications- Feng Wang
Department of Cardiology, Children’s Hospital of Fudan University
2 shared publications Haosheng Yang
The Graduate School of Biomedical Sciences, Icahn School of Medicine at Mount Sinai, New York, New York
2 shared publications- Laishuan Wang
Department of Neonatology, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
2 shared publications Lan He
Cardiovascular Center, Children's Hospital of Fudan University , Shanghai, 201102
2 shared publications
Latest Publications
- 28 September 2023
- Published by Elsevier in Cytokine & Growth Factor Reviews
- Vol. 74, 40-55
Extracellular vesicles in cardiovascular diseases: From pathophysiology to diagnosis and therapy
- 28 September 2023
- Published by Elsevier in Cytokine & Growth Factor Reviews
- Vol. 74, 40-55
Extracellular vesicles in cardiovascular diseases: From pathophysiology to diagnosis and therapy
- Open Access
- 11 July 2022
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (5) , 3619-3624
Mid-Aortic Syndrome: A Rare Cause of Heart Failure in Infants
This case reports describe a rare disease, mid-aortic syndrome (MAS), that can cause severe heart failure and hypertension in infancy. The typical images, key points of diagnosis, and therapy methods of the disease have also been presented. We report two critical thoracoabdominal aortic coarctation cases in infants aged 2 and 11 months with severe heart failure. The patients were initially misdiagnosed as dilated myocardiopathy, with the correct diagnosis confirmed through imaging. Both patients underwent balloon angioplasty; one patient also had bare-metal stents implanted. The patient treated with balloon angioplasty alone died after the procedure, whereas the other patient recovered well. In conclusion, careful physical examinations, especially upper and lower extremity blood pressure differences and palpation of upper and lower limb pulses, are critical in unexplained infant heart failure cases. Stent implantation may be a safer and more effective treatment than simple balloon angioplasty in infants with MAS.
- 11 July 2022
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (5) , 3619-3624
Open AccessMid-Aortic Syndrome: A Rare Cause of Heart Failure in Infants
This case reports describe a rare disease, mid-aortic syndrome (MAS), that can cause severe heart failure and hypertension in infancy. The typical images, key points of diagnosis, and therapy methods of the disease have also been presented. We report two critical thoracoabdominal aortic coarctation cases in infants aged 2 and 11 months with severe heart failure. The patients were initially misdiagnosed as dilated myocardiopathy, with the correct diagnosis confirmed through imaging. Both patients underwent balloon angioplasty; one patient also had bare-metal stents implanted. The patient treated with balloon angioplasty alone died after the procedure, whereas the other patient recovered well. In conclusion, careful physical examinations, especially upper and lower extremity blood pressure differences and palpation of upper and lower limb pulses, are critical in unexplained infant heart failure cases. Stent implantation may be a safer and more effective treatment than simple balloon angioplasty in infants with MAS.
- 1 April 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (4) , 399-407
Midterm Outcomes of Angioplasty for Pediatric Renovascular Hypertension
- 1 April 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (4) , 399-407
Midterm Outcomes of Angioplasty for Pediatric Renovascular Hypertension
- Open Access
- 5 August 2021
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 9
Case Report: Recurrent Left Posterior Fascicular Ventricular Tachycardia in a Newborn
Left posterior fascicular ventricular tachycardia (LPFVT) is extremely rare in neonates. We described a 17-day-old girl with LPFVT who was initially misdiagnosed as supraventricular tachycardia (SVT). Eventually, she was successfully treated by amiodarone infusion followed by oral amiodarone with propranolol for 9 months, and LPFVT spontaneously resolved after a 1-year follow-up. This case report illustrated the basic principles and caveats in differential diagnosis of LPFVT in the neonatal age group. With proper diagnosis and therapy, neonatal LPFVT might regress in the first year of life.
- 5 August 2021
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 9
Open AccessCase Report: Recurrent Left Posterior Fascicular Ventricular Tachycardia in a Newborn
Left posterior fascicular ventricular tachycardia (LPFVT) is extremely rare in neonates. We described a 17-day-old girl with LPFVT who was initially misdiagnosed as supraventricular tachycardia (SVT). Eventually, she was successfully treated by amiodarone infusion followed by oral amiodarone with propranolol for 9 months, and LPFVT spontaneously resolved after a 1-year follow-up. This case report illustrated the basic principles and caveats in differential diagnosis of LPFVT in the neonatal age group. With proper diagnosis and therapy, neonatal LPFVT might regress in the first year of life.
- Open Access
- 13 March 2021
- Published by Springer Nature in Health and Technology
- Vol. 11 (3) , 563-574
Optimizing the innovation and development process of medical devices - a study based on angiographic equipment
Cardiovascular diseases are the leading cause of death. The gold standard for their diagnosis and treatment are angiographic procedures, which require specialized equipment. The speed of their continued development is important as better technology enables progress in clinical outcomes. This article proposes a new process model for the innovation and development and shows how to optimize it such that it takes minimal time. The conducted literature research identifies this closed loop process model as being unique in comparison to the well-established models proposed by Brockhoff, Cooper, Crawford, Durfee, Ebert, Eppinger, Hughes, Pleschak, Thom, Ulrich, Vahs and Witt. During a long-term observation of the innovation and development process of angiographic systems 672 data sets on 302 topics were collected over 47 months to validate this process model. The data collected is equivalent to efforts worth 30 man-years. This input was used to calculate key process parameters, analyse key process roles, evaluate the use of problem-solving methods and identify key technologies. We recommend to apply a continuous loop process in the context of innovation and development of medical devices. In the analysed datasets a potential of an up to 20% shorter process time was identified. Our results can be used for an Activity Based Costing Approach or be applied to bring new or upgraded angiography systems faster to market benefitting patient outcome due to improved diagnosis and treatment. According to the best knowledge of the authors no comparable data collection relating to angiography systems has been performed and presented anywhere else yet.
- 13 March 2021
- Published by Springer Nature in Health and Technology
- Vol. 11 (3) , 563-574
Open AccessOptimizing the innovation and development process of medical devices - a study based on angiographic equipment
Cardiovascular diseases are the leading cause of death. The gold standard for their diagnosis and treatment are angiographic procedures, which require specialized equipment. The speed of their continued development is important as better technology enables progress in clinical outcomes. This article proposes a new process model for the innovation and development and shows how to optimize it such that it takes minimal time. The conducted literature research identifies this closed loop process model as being unique in comparison to the well-established models proposed by Brockhoff, Cooper, Crawford, Durfee, Ebert, Eppinger, Hughes, Pleschak, Thom, Ulrich, Vahs and Witt. During a long-term observation of the innovation and development process of angiographic systems 672 data sets on 302 topics were collected over 47 months to validate this process model. The data collected is equivalent to efforts worth 30 man-years. This input was used to calculate key process parameters, analyse key process roles, evaluate the use of problem-solving methods and identify key technologies. We recommend to apply a continuous loop process in the context of innovation and development of medical devices. In the analysed datasets a potential of an up to 20% shorter process time was identified. Our results can be used for an Activity Based Costing Approach or be applied to bring new or upgraded angiography systems faster to market benefitting patient outcome due to improved diagnosis and treatment. According to the best knowledge of the authors no comparable data collection relating to angiography systems has been performed and presented anywhere else yet.
- 2 September 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (10) , 1297-1299
Late effects of radiofrequency ablation lesions resulting in a progressive mitral valve perforation in a 2-month-old infant
There has been great concern with the use of radiofrequency ablation in infants since radiofrequency ablation lesions were shown to have a progressing nature in immature myocardium of animals. In this report, we present a 2-month-old infant with life-threatening medically refractory supraventricular tachycardia. Radiofrequency ablation successfully cured arrhythmia; however, late effects of radiofrequency ablation lesions resulted in a progressive mitral valve perforation requiring surgical repair.
- 2 September 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (10) , 1297-1299
Late effects of radiofrequency ablation lesions resulting in a progressive mitral valve perforation in a 2-month-old infant
There has been great concern with the use of radiofrequency ablation in infants since radiofrequency ablation lesions were shown to have a progressing nature in immature myocardium of animals. In this report, we present a 2-month-old infant with life-threatening medically refractory supraventricular tachycardia. Radiofrequency ablation successfully cured arrhythmia; however, late effects of radiofrequency ablation lesions resulted in a progressive mitral valve perforation requiring surgical repair.
- 9 July 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (7) , 967-971
Reducing radiation dose in paediatric interventional cardiac catheterisation
Objective:Radiation exposure during paediatric cardiac catheterisation procedures should be minimised to “as low as reasonably achievable”. The aim of this study was to evaluate the effectiveness of a modified radiation safety protocol in reducing patient dose during paediatric interventional cardiac catheterisation.Methods:Radiation dose data were retrospectively extracted from January 2014 to December 2015 (Standard group) and prospectively collected from January 2016 to December 2017 (Low-dose group) after implementation of a modified radiation safety protocol. Both groups included five most common procedures: atrial septal defect closure, patent ductus arteriosus closure, perimembranous ventricular septal defect closure, pulmonary valvuloplasty, and supraventricular tachycardia ablation.Results:Median air Kerma was 48.4, 50.5, 29.75, 149, 218, and 12.9 mGy for atrial septal defect closure, pulmonary valvuloplasty, patent ductus arteriosus closure <20 kg, ventricular septal defect closure <20 kg, ventricular septal defect closure ≧20 kg, and supraventricular tachycardia ablation in Standard group, respectively, which significantly decreased to 18.75, 20.7, 11.5, 41.9, 117, and 3.3 mGy in Low-dose group (p < 0.05). This represents a reduction in dose to each patient between 46 and 74%. Among five procedural types in Low-dose group, dose of ventricular septal defect closure was the highest with median air Kerma of 62.5 mGy, dose area product of 364.7 μGy.m2, and dose area product per body weight of 21.5 μGy.m2/kg, respectively, along with the longest fluoroscopy time of 9.9 minutes.Conclusion:We provided a feasible radiation safety protocol with specific settings on a case-by-case basis. Increasing awareness and adequate training of a practical radiation dose reduction program are essential to improve radiation protection for children.
- 9 July 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (7) , 967-971
Reducing radiation dose in paediatric interventional cardiac catheterisation
Objective:Radiation exposure during paediatric cardiac catheterisation procedures should be minimised to “as low as reasonably achievable”. The aim of this study was to evaluate the effectiveness of a modified radiation safety protocol in reducing patient dose during paediatric interventional cardiac catheterisation.Methods:Radiation dose data were retrospectively extracted from January 2014 to December 2015 (Standard group) and prospectively collected from January 2016 to December 2017 (Low-dose group) after implementation of a modified radiation safety protocol. Both groups included five most common procedures: atrial septal defect closure, patent ductus arteriosus closure, perimembranous ventricular septal defect closure, pulmonary valvuloplasty, and supraventricular tachycardia ablation.Results:Median air Kerma was 48.4, 50.5, 29.75, 149, 218, and 12.9 mGy for atrial septal defect closure, pulmonary valvuloplasty, patent ductus arteriosus closure <20 kg, ventricular septal defect closure <20 kg, ventricular septal defect closure ≧20 kg, and supraventricular tachycardia ablation in Standard group, respectively, which significantly decreased to 18.75, 20.7, 11.5, 41.9, 117, and 3.3 mGy in Low-dose group (p < 0.05). This represents a reduction in dose to each patient between 46 and 74%. Among five procedural types in Low-dose group, dose of ventricular septal defect closure was the highest with median air Kerma of 62.5 mGy, dose area product of 364.7 μGy.m2, and dose area product per body weight of 21.5 μGy.m2/kg, respectively, along with the longest fluoroscopy time of 9.9 minutes.Conclusion:We provided a feasible radiation safety protocol with specific settings on a case-by-case basis. Increasing awareness and adequate training of a practical radiation dose reduction program are essential to improve radiation protection for children.
- 4 June 2019
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 55 (1) , 135-137
Rare vascular ring of right aortic arch and aberrant left subclavian artery in association with bilateral ductus arteriosus
- 4 June 2019
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 55 (1) , 135-137
Rare vascular ring of right aortic arch and aberrant left subclavian artery in association with bilateral ductus arteriosus
- 23 April 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (5) , 679-683
Accuracy of cardiac auscultation in detection of neonatal congenital heart disease by general paediatricians
Background: Challenges remain in the judgement of pathological murmurs in newborns at maternity hospitals, and there are still many simple major CHD patients in developing countries who are not diagnosed in a timely fashion. This study aimed to evaluate the accuracy of cardiac auscultation on neonatal CHD by general paediatricians.Methods: We conducted a prospective study at three hospitals. All asymptomatic newborns underwent auscultation, pulse oximetry monitoring, and echocardiography. Major CHD was classified and confirmed through follow-up. We evaluated the accuracy of various degrees of murmurs for detecting major CHD to determine the most appropriate standards and time of auscultation.Results: A total of 6750 newborns were included. The median age of auscultation was 43 hours. Cardiac murmurs were identified in 6.6% of newborns. For all CHD, 44.4% had varying degrees of murmurs. A murmur of grade ≥2 used as a reference standard for major CHD had a sensitivity of 89.58%. The false positive rate of murmurs of grade ≥2 for detecting major CHD was significantly negatively related to auscultation time, with 84.4% of false positives requiring follow-up for non-major CHD cardiac issues. Auscultation after 27 hours of life could reduce the false positive rate of major CHD from 2.7 to 0.9%.Conclusions: With appropriate training, maternity hospital’s paediatricians can detect major CHD with high detection rates with an acceptable false positive rate.
- 23 April 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (5) , 679-683
Accuracy of cardiac auscultation in detection of neonatal congenital heart disease by general paediatricians
Background: Challenges remain in the judgement of pathological murmurs in newborns at maternity hospitals, and there are still many simple major CHD patients in developing countries who are not diagnosed in a timely fashion. This study aimed to evaluate the accuracy of cardiac auscultation on neonatal CHD by general paediatricians.Methods: We conducted a prospective study at three hospitals. All asymptomatic newborns underwent auscultation, pulse oximetry monitoring, and echocardiography. Major CHD was classified and confirmed through follow-up. We evaluated the accuracy of various degrees of murmurs for detecting major CHD to determine the most appropriate standards and time of auscultation.Results: A total of 6750 newborns were included. The median age of auscultation was 43 hours. Cardiac murmurs were identified in 6.6% of newborns. For all CHD, 44.4% had varying degrees of murmurs. A murmur of grade ≥2 used as a reference standard for major CHD had a sensitivity of 89.58%. The false positive rate of murmurs of grade ≥2 for detecting major CHD was significantly negatively related to auscultation time, with 84.4% of false positives requiring follow-up for non-major CHD cardiac issues. Auscultation after 27 hours of life could reduce the false positive rate of major CHD from 2.7 to 0.9%.Conclusions: With appropriate training, maternity hospital’s paediatricians can detect major CHD with high detection rates with an acceptable false positive rate.
- 13 August 2018
- Published by Springer Nature in Lung
- Vol. 196 (5) , 631-632
Esophageal Lung in Association with Pulmonary Vascular Anomalies
We present a 7.8-month-old girl with recurrent pneumonia, growth retardation, and tachypnea. Computed tomography revealed a particularly unusual esophageal lung, in association with pulmonary vascular anomalies of right pulmonary veins atresia and right pulmonary artery hypoplasia.
- 13 August 2018
- Published by Springer Nature in Lung
- Vol. 196 (5) , 631-632
Esophageal Lung in Association with Pulmonary Vascular Anomalies
We present a 7.8-month-old girl with recurrent pneumonia, growth retardation, and tachypnea. Computed tomography revealed a particularly unusual esophageal lung, in association with pulmonary vascular anomalies of right pulmonary veins atresia and right pulmonary artery hypoplasia.