Adam Tan Mohd Amin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adam Tan Mohd Amin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ashrani Aizzuddin Abdul Rahni
Universiti Kebangsaan Malaysia
4 shared publications Rozilawati Ahmad
Faculty of Health Science, Universiti Kebangsaan Malaysia (UKM) Medical Center, Cheras, Kuala Lumpur, Malaysia
3 shared publicationsSiti Salasiah Mokri
Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia
3 shared publicationsCheng Yee Low
2 shared publicationsAbdul Hakim Ab Rahim
1 shared publicationAbdul Hakim Ab. Rahim
Universiti Teknologi MARA (UiTM)
1 shared publication
Latest Publications
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 451-456
Development of a 4D phantom for respiratory motion modeling during Cone-Beam CT (CBCT) imaging on the Varian On-Board Imager (OBI)
Cone-beam computed tomography (CBCT) imaging is widely used in image guided radiotherapy. Current protocols assume the patient to be static during imaging but, respiratory motion can affect the reconstructed CBCT images. The objective of this study is to simulate respiratory motion effects on a CBCT image using a digital phantom constructed from actual 4D Magnetic Resonance Imaging (MRI) data. Firstly, the length of the 4D MR data was extended to 1-minute, mimicking a typical CBCT imaging acquisition period over a 360-degree scan. The MR images are then segmented and converted to CT attenuation values. The Varian On-Board Imager geometry was used in the simulation where Poisson noise was added to realistically model imaging noise. Simulated projections were reconstructed using the standard Feldkamp-Davis-Kress algorithm. The images were then compared against the developed phantom at two respiratory positions: end-inspiration, and end-expiration, using normalized root mean squared error (NRMSE) and difference images. The results were encouraging with a NRMSE increment of 0.59% when noise was added into the phantom, whilst a -0.51% decrease when an additional Hann filter was used during reconstruction. The respiratory motion effects were successfully modeled when the results showed a 0.55\% difference between the different positions. This is also observed from the difference images by selecting a region-of-interest with NRMSE values evaluated as 33.84% and 51.26% respectively, constituting a significant 17.42% difference. Therefore, it is evident that respiratory motion affects image reconstruction quality. This indicates the currently practiced protocol and reconstruction algorithm must consider respiratory motion to ensure accuracy.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 451-456
Development of a 4D phantom for respiratory motion modeling during Cone-Beam CT (CBCT) imaging on the Varian On-Board Imager (OBI)
Cone-beam computed tomography (CBCT) imaging is widely used in image guided radiotherapy. Current protocols assume the patient to be static during imaging but, respiratory motion can affect the reconstructed CBCT images. The objective of this study is to simulate respiratory motion effects on a CBCT image using a digital phantom constructed from actual 4D Magnetic Resonance Imaging (MRI) data. Firstly, the length of the 4D MR data was extended to 1-minute, mimicking a typical CBCT imaging acquisition period over a 360-degree scan. The MR images are then segmented and converted to CT attenuation values. The Varian On-Board Imager geometry was used in the simulation where Poisson noise was added to realistically model imaging noise. Simulated projections were reconstructed using the standard Feldkamp-Davis-Kress algorithm. The images were then compared against the developed phantom at two respiratory positions: end-inspiration, and end-expiration, using normalized root mean squared error (NRMSE) and difference images. The results were encouraging with a NRMSE increment of 0.59% when noise was added into the phantom, whilst a -0.51% decrease when an additional Hann filter was used during reconstruction. The respiratory motion effects were successfully modeled when the results showed a 0.55\% difference between the different positions. This is also observed from the difference images by selecting a region-of-interest with NRMSE values evaluated as 33.84% and 51.26% respectively, constituting a significant 17.42% difference. Therefore, it is evident that respiratory motion affects image reconstruction quality. This indicates the currently practiced protocol and reconstruction algorithm must consider respiratory motion to ensure accuracy.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 33-36
Comparison Between Projection Weighting and Rebinning Approaches in Analytical Image Reconstruction in Off-Center Flat Panel Cone-Beam CT Imaging
In cone-beam CT (CBCT) imaging, a half-fan (HF) mode acquisition can be used to obtain a larger field-of-view (FOV) without physically increasing the detector size. However, this leads to an asymmetric sinogram with a truncated set of projection that needs to be considered during image reconstruction., especially when using analytical methods such as the filtered backprojection (FBP) and its 3D approximation, the Feldkamp-Davis-Kress (FDK) algorithm. Various approaches have been suggested in literature, which can be roughly categorized as weighting based and projection rebinning approaches. In this paper, a comparison between the two approaches are made using the XCAT phantom, based on the geometry of the Varian On-Board Imager (OBI) as the CBCT acquisition device that is usually used for image guided radiotherapy (IGRT) during treatment delivery. It is found that analytical reconstruction alone will produce a percent normalized root mean squared error (NRMSE) of 36.81% in the reconstructed image, whereas using the weighting based and rebinning approaches reduces this error to 22.86% and 4.68% respectively. Apart from that, the weighting based approach is also found to be on average biased and produces an overall lower intensity in the reconstructed image whereas the rebinning approach does not have this problem, as well as having a smaller standard deviation of the intensity deviations from the original phantom image as the ground truth.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 33-36
Comparison Between Projection Weighting and Rebinning Approaches in Analytical Image Reconstruction in Off-Center Flat Panel Cone-Beam CT Imaging
In cone-beam CT (CBCT) imaging, a half-fan (HF) mode acquisition can be used to obtain a larger field-of-view (FOV) without physically increasing the detector size. However, this leads to an asymmetric sinogram with a truncated set of projection that needs to be considered during image reconstruction., especially when using analytical methods such as the filtered backprojection (FBP) and its 3D approximation, the Feldkamp-Davis-Kress (FDK) algorithm. Various approaches have been suggested in literature, which can be roughly categorized as weighting based and projection rebinning approaches. In this paper, a comparison between the two approaches are made using the XCAT phantom, based on the geometry of the Varian On-Board Imager (OBI) as the CBCT acquisition device that is usually used for image guided radiotherapy (IGRT) during treatment delivery. It is found that analytical reconstruction alone will produce a percent normalized root mean squared error (NRMSE) of 36.81% in the reconstructed image, whereas using the weighting based and rebinning approaches reduces this error to 22.86% and 4.68% respectively. Apart from that, the weighting based approach is also found to be on average biased and produces an overall lower intensity in the reconstructed image whereas the rebinning approach does not have this problem, as well as having a smaller standard deviation of the intensity deviations from the original phantom image as the ground truth.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 117-122
Modeling the Varian On-Board Imager (OBI): Cone-beam CT (CBCT) operating modes
Cone-beam CT (CBCT) imaging is heavily being utilized in radiotherapy treatment as means of treating cancer patients. One of the platforms is the Varian On-Board Imager (oBI) where kilo-volts (kV) CBCT imaging is used. In this study, a model of the OBI is developed to simulate the two scan modes that are available, namely: Full-Fan (FF) and Half-Fan (HF) modes. By shifting the same set of 1024×768 detector panels laterally, a larger field-of-view (FOV) is achieved in the HF scan mode. Using a realistic XCAT phantom, the different FOVs are simulated using analytical Feldkamp-Davis-Kress (FDK) and iterative Simultaneous Algebraic Reconstruction Technique (SART) reconstruction methods. As suggested in literatures, ring and radiant artifacts can occur in the HF mode due to its geometry. To implement fast analytical method, an adequate weight factor needs to be applied on the projection data prior to reconstruction. The percentage normalized root mean squared error (NRMSE) value for FF and HF using analytical FDK reconstruction are 7.12% and 16.63% respectively. Using the iterative SART, the respective values are and 2.69% and 4.65%. The simulation model of the Varian OBI: CBCT operating mode is expected to encourage and enhance further studies on image guided radiation therapy (IGRT) during radiotherapy treatment delivery.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 117-122
Modeling the Varian On-Board Imager (OBI): Cone-beam CT (CBCT) operating modes
Cone-beam CT (CBCT) imaging is heavily being utilized in radiotherapy treatment as means of treating cancer patients. One of the platforms is the Varian On-Board Imager (oBI) where kilo-volts (kV) CBCT imaging is used. In this study, a model of the OBI is developed to simulate the two scan modes that are available, namely: Full-Fan (FF) and Half-Fan (HF) modes. By shifting the same set of 1024×768 detector panels laterally, a larger field-of-view (FOV) is achieved in the HF scan mode. Using a realistic XCAT phantom, the different FOVs are simulated using analytical Feldkamp-Davis-Kress (FDK) and iterative Simultaneous Algebraic Reconstruction Technique (SART) reconstruction methods. As suggested in literatures, ring and radiant artifacts can occur in the HF mode due to its geometry. To implement fast analytical method, an adequate weight factor needs to be applied on the projection data prior to reconstruction. The percentage normalized root mean squared error (NRMSE) value for FF and HF using analytical FDK reconstruction are 7.12% and 16.63% respectively. Using the iterative SART, the respective values are and 2.69% and 4.65%. The simulation model of the Varian OBI: CBCT operating mode is expected to encourage and enhance further studies on image guided radiation therapy (IGRT) during radiotherapy treatment delivery.
- Open Access
- 31 May 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 851 (1) , 012012
Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner
Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner, which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon's algorithm to generate the system matrix, H. This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H I; where S is the projections produced from the image, I. Due to the 'cone-beam geometry' along the z-axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods.
- 31 May 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 851 (1) , 012012
Open AccessModelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner
Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner, which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon's algorithm to generate the system matrix, H. This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H I; where S is the projections produced from the image, I. Due to the 'cone-beam geometry' along the z-axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods.
- Open Access
- 1 July 2015
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 773-774, 883-887
SMA Actuated Finger Exoskeleton Device for Rehabilitation of Acute Paresis Patient
Functional recovery of upper limb after stroke is crucial to restore the ability to perform activities of daily living (ADL). This paper presents a robotic rehabilitation approach based on repetitive exercise aimed to help stroke survivors relearn the skills of finger flexion and extension at the comfort of their home. The finger rehabilitation device deploysShape Memory Alloy(SMA) wires as an actuation approach to deliver three degrees of freedom per finger module. The advantages and challenges of using SMA wires rather than conventional actuators are discussed. A prototype of the finger rehabilitation device was built using PLA material and experiments have been conducted for the purposes of feasibility study. Tests conducted on the wires suggest that it has to have sufficient weight and also has to be stretching at high temperature rather than room temperature in order to have an optimum range of recovery.
- 1 July 2015
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 773-774, 883-887
Open AccessSMA Actuated Finger Exoskeleton Device for Rehabilitation of Acute Paresis Patient
Functional recovery of upper limb after stroke is crucial to restore the ability to perform activities of daily living (ADL). This paper presents a robotic rehabilitation approach based on repetitive exercise aimed to help stroke survivors relearn the skills of finger flexion and extension at the comfort of their home. The finger rehabilitation device deploysShape Memory Alloy(SMA) wires as an actuation approach to deliver three degrees of freedom per finger module. The advantages and challenges of using SMA wires rather than conventional actuators are discussed. A prototype of the finger rehabilitation device was built using PLA material and experiments have been conducted for the purposes of feasibility study. Tests conducted on the wires suggest that it has to have sufficient weight and also has to be stretching at high temperature rather than room temperature in order to have an optimum range of recovery.
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Computer Science
- Vol. 76, 474-479
Sensor Based Mobile Navigation Using Humanoid Robot Nao
- 1 January 2015
- Published by Elsevier in Procedia Computer Science
- Vol. 76, 474-479
Open AccessSensor Based Mobile Navigation Using Humanoid Robot Nao
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Evaluation of hand direction for stroke patient based on 3R under-actuated robot manipulator
This paper presents a simplified version of hand exoskeleton design for stroke patient. The proposed powered exoskeleton concentrates at the hand of the human body. The simplified design is made using aluminum. The whole system is built with the cost in mind to make it more affordable as the current exoskeleton projects required heavy funding. Rotary Digital Encoder is used as sensors and the data from the sensors transferred out to the computer for keeping the position angle. The control is done using the MATLAB software. The 3R under-actuated robot manipulator consists of three links with three joining (First and Second joints as Active, attached motor and rotary digital encoder to theirself and Third joint as Passive, attach with rotary digital encoder and without motor to itself). A hand movement algorithm has been investigate by two methods; Simulation and Real-time. By using these methods, the hand algorithm has being evaluated in order to control the movement of passive joint according to the instruction during experiment.
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Evaluation of hand direction for stroke patient based on 3R under-actuated robot manipulator
This paper presents a simplified version of hand exoskeleton design for stroke patient. The proposed powered exoskeleton concentrates at the hand of the human body. The simplified design is made using aluminum. The whole system is built with the cost in mind to make it more affordable as the current exoskeleton projects required heavy funding. Rotary Digital Encoder is used as sensors and the data from the sensors transferred out to the computer for keeping the position angle. The control is done using the MATLAB software. The 3R under-actuated robot manipulator consists of three links with three joining (First and Second joints as Active, attached motor and rotary digital encoder to theirself and Third joint as Passive, attach with rotary digital encoder and without motor to itself). A hand movement algorithm has been investigate by two methods; Simulation and Real-time. By using these methods, the hand algorithm has being evaluated in order to control the movement of passive joint according to the instruction during experiment.
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Technology
- Vol. 15, 775-782
Terrain Classification for Track-driven Agricultural Robots
- 1 January 2014
- Published by Elsevier in Procedia Technology
- Vol. 15, 775-782
Open AccessTerrain Classification for Track-driven Agricultural Robots
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Technology
- Vol. 15, 765-774
Adaptive Controller Algorithm for 2-DOF Humanoid Robot Arm
- 1 January 2014
- Published by Elsevier in Procedia Technology
- Vol. 15, 765-774
Open AccessAdaptive Controller Algorithm for 2-DOF Humanoid Robot Arm
- 3 September 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 393, 604-610
The Development of Finger Rehabilitation Device for Stroke Patients
Most stroke patients who have lost the ability to use their fingers do not recover the functions of the fingers in their activity of daily living (ADL). This paper presents a novel approach in finger rehabilitation for acute paralysed stroke survivors. Based on repetitive exercise concept, the device is designed to provide support for fingers to do flexion and extension movements according to the patients range of motion. A conceptual design of the device is proposed after considering the current mechanism and control from similar current devices published and commercialised. A comparison between 4 existing main working mechanisms: (1) Pneumatic Cylinders, (2) Artificial Rubber Muscles, (3) Linkage Mechanism, (4) Cable-Driven Mechanism is also provided in this paper. The key for designing the device is home-based practice, easy to use and affordable. Further investigation and experiments on the proposed: Cable Actuated Finger Exoskeleton (CAFEx) are currently still in progress.
- 3 September 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 393, 604-610
The Development of Finger Rehabilitation Device for Stroke Patients
Most stroke patients who have lost the ability to use their fingers do not recover the functions of the fingers in their activity of daily living (ADL). This paper presents a novel approach in finger rehabilitation for acute paralysed stroke survivors. Based on repetitive exercise concept, the device is designed to provide support for fingers to do flexion and extension movements according to the patients range of motion. A conceptual design of the device is proposed after considering the current mechanism and control from similar current devices published and commercialised. A comparison between 4 existing main working mechanisms: (1) Pneumatic Cylinders, (2) Artificial Rubber Muscles, (3) Linkage Mechanism, (4) Cable-Driven Mechanism is also provided in this paper. The key for designing the device is home-based practice, easy to use and affordable. Further investigation and experiments on the proposed: Cable Actuated Finger Exoskeleton (CAFEx) are currently still in progress.