YTYukichi Tanahashi

Yukichi Tanahashi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yukichi Tanahashi has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radiomic Analysis Applied to Pretreatment Gd-EOB-DTPA-enhanced MR Imaging Predicts Response to Selective Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    by Yukichi Tanahashi, Takanobu Ikeda, Koh Kubota, Masaya Kutsuna, Tatsunori Kobayashi, Satoshi Funayama, Kumi Ozaki, Shintaro Ichikawa, Satoshi Goshima

    To evaluate the efficacy of radiomic analysis applied to pretreatment gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI (Gd-EOB-DTPA-MRI) for predicting the response to transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma. Data and images from 40 consecutive patients (28 men, 12 women) who underwent pretreatment Gd-EOB-DTPA-MRI and a total of 52 TACE procedures for 75 non-treated hepatocellular carcinomas were retrospectively analyzed. Two radiologists manually outlined lesions on pretreatment arterial- and hepatobiliary-phase hepatic images to extract radiomic features. The radiomics data from one observer were randomly divided into a training dataset and a validation dataset in the ratio of 7:3. Radiomic features extracted using least absolute shrinkage and selection operator (LASSO) binomial regression applied to the training dataset and that showed intraclass correlation coefficients (ICC) >0.7 were used to construct a radiomic model. The predictive performance of the model was evaluated using receiver operating characteristics curves. Lesions classified as showing a complete or partial response according to the modified RECIST criteria were allocated to a response group. There was no significant difference in Child-Pugh score, tumor marker values, or TACE procedure between response and non-response groups. Six radiomic features were selected using the LASSO binomial regression and 5 of them showing an ICC >0.7 were used to establish the radiomic model. The area under the curve of the radiomic model was 0.89 for the training dataset, 0.83 for the validation dataset, and 0.83 for the other observer's data. The sensitivity and specificity for the prediction of tumor response to TACE were 78% and 92% for the training dataset; 71% and 50% for the validation dataset; and 75% and 79% for the other observer's data. The pretreatment Gd-EOB-DTPA-MRI-based radiomic model is useful for predicting the response to TACE of hepatocellular carcinoma.


  • Open Access

    Improved vascular depiction and image quality through deep learning reconstruction of CT hepatic arteriography during transcatheter arterial chemoembolization

    by Yukichi Tanahashi, Koh Kubota, Takayuki Nomura, Takanobu Ikeda, Masaya Kutsuna, Satoshi Funayama, Tatsunori Kobayashi, Kumi Ozaki, Shintaro Ichikawa, Satoshi Goshima

    Purpose: To evaluate the effect of deep learning reconstruction (DLR) on vascular depiction, tumor enhancement, and image quality of computed tomography hepatic arteriography (CTHA) images acquired during transcatheter arterial chemoembolization (TACE). Methods: Institutional review board approval was obtained. Twenty-seven patients (18 men and 9 women, mean age, 75.7 years) who underwent CTHA immediately before TACE were enrolled. All images were reconstructed using three reconstruction algorithms: hybrid-iterative reconstruction (hybrid-IR), DLR with mild strength (DLR-M), and DLR with strong strength (DLR-S). Vascular depiction, tumor enhancement, feeder visualization, and image quality of CTHA were quantitatively and qualitatively assessed by two radiologists and compared between the three reconstruction algorithms. Results: The mean signal-to-noise ratios (SNR) of sub-segmental arteries and sub-sub-segmental arteries, and the contrast-to-noise ratio (CNR) of tumors, were significantly higher on DLR-S than on DLR-M and hybrid-IR (P < 0.001). The mean qualitative score for sharpness of sub-segmental and sub-sub-segmental arteries was significantly better on DLR-S than on DLR-M and hybrid-IR (P < 0.001). There was no significant difference in the feeder artery detection rate of automated feeder artery detection software among three reconstruction algorithms (P = 0.102). The contrast, continuity, and confidence level of feeder artery detection was significantly better on DLR-S than on DLR-M (P = 0.013, 0.005, and 0.001) and hybrid-IR (P < 0.001, P = 0.002, and P < 0.001). The weighted kappa values between two readers for qualitative scores of feeder artery visualization were 0.807–0.874. The mean qualitative scores for sharpness, granulation, and diagnostic acceptability of CTHA were better on DLR-S than on DLR-M and hybrid-IR (P < 0.001). Conclusions: DLR significantly improved the SNR of small hepatic arteries, the CNR of tumor, and feeder artery visualization on CTHA images. DLR-S seems to be better suited to routine CTHA in TACE than does hybrid-IR.


  • Intranodal dynamic contrast-enhanced CT lymphangiography and dynamic contrast-enhanced MR lymphangiography in microminipig

    by Yukichi Tanahashi, Shinichi Shoda, Hiroshi Kawada, Tomohiro Ando, Shoma Nagata, Masaki Takasu, Fuminori Hyodo, Satoshi Goshima, Takashi Mori, Masayuki Matsuo

    Objectives To evaluate the feasibility and image quality of intranodal dynamic contrast-enhanced CT lymphangiography (DCCTL) and dynamic contrast-enhanced MR lymphangiography (DCMRL) in microminipigs. Methods Our institution’s committee for animal research and welfare provided approval. Three microminipigs underwent DCCTL and DCMRL after inguinal lymph node injection of 0.1 mL/kg contrast media. Mean CT values on DCCTL and signal intensity (SI) on DCMRL were measured at the venous angle and thoracic duct (TD). The contrast enhancement index (CEI; increase in CT values pre- to post-contrast) and signal intensity ratio (SIR; SI of lymph divided by SI of muscle) were evaluated. The morphologic legibility, visibility, and continuity of lymphatics were qualitatively evaluated using a 4-point scale. Two microminipigs underwent DCCTL and DCMRL after lymphatic disruption and the detectability of lymphatic leakage was evaluated. Results The CEI peaked at 5–10 min in all microminipigs. The SIR peaked at 2–4 min in two microminipigs and at 4–10 min in one microminipig. The peak CEI and SIR values were 235.6 HU and 4.8 for venous angle, 239.4 HU and 2.1 for upper TD, and 387.3 HU and 2.1 for middle TD. The visibility and continuity of upper–middle TD scores were 4.0 and 3.3–3.7 for DCCTL, and 4.0 and 4.0 for DCMRL. In the injured lymphatic model, both DCCTL and DCMRL demonstrated lymphatic leakage. Conclusions DCCTL and DCMRL in a microminipig model enabled excellent visualization of central lymphatic ducts and lymphatic leakage, indicating the research and clinical potential of both modalities. Key Points • Intranodal dynamic contrast-enhanced computed tomography lymphangiography showed a contrast enhancement peak at 5–10 min in all microminipigs. • Intranodal dynamic contrast-enhanced magnetic resonance lymphangiography showed a contrast enhancement peak at 2–4 min in two microminipigs and at 4–10 min in one microminipig. • Both intranodal dynamic contrast-enhanced computed tomography lymphangiography and dynamic contrast-enhanced magnetic resonance lymphangiography demonstrated the central lymphatic ducts and lymphatic leakage.


  • Open Access

    Utility of Noncontrast Magnetic Resonance Angiography for Aneurysm Follow-Up and Detection of Endoleaks after Endovascular Aortic Repair

    by Hiroshi Kawada, Satoshi Goshima, Kota Sakurai, Yoshifumi Noda, Kimihiro Kajita, Yukichi Tanahashi, Nobuyuki Kawai, Narihiro Ishida, Katsuya Shimabukuro, Kiyoshi Doi, et al.

    Kawada H, et al. Korean J Radiol. 2020 Jul;21:e190. https://doi.org/10.3348/kjr.2020.0001


  • Intranodal Popliteal Lymphangiography for Postoperative Lymphorrhea after Inguinal Node Dissection

    by Yukichi Tanahashi, Hiroshi Kawada, Satoshi Goshima, Takao Takahashi, Kazuhiro Yoshida, Masayuki Matsuo


  • Dynamic contrast-enhanced computed tomography lymphangiography with intranodal injection of water-soluble iodine contrast media in microminipig: imaging protocol and feasibility

    by Yukichi Tanahashi, Ryota Iwasaki, Shinichi Shoda, Hiroshi Kawada, Tomohiro Ando, Masaki Takasu, Fuminori Hyodo, Satoshi Goshima, Takashi Mori, Masayuki Matsuo

    Objectives To evaluate the optimal imaging protocol and the feasibility of intranodal dynamic contrast-enhanced computed tomography lymphangiography (DCCTL) in microminipigs. Methods The Committee for Animal Research and Welfare provided university approval. Five female microminipigs underwent DCCTL after inguinal lymph node injection of 0.1 mL/kg of iodine contrast media at a rate of 0.3 mL/min with three different iodine concentrations: group 1, 75 mgI/mL; group 2, 150 mgI/mL; and group 3, 300 mgI/mL. The CT values of the venous angle, thoracic duct (TD), cisterna chyli, iliac lymphatic duct, and iliac lymph node were measured; increases in CT values pre- to post-contrast were assessed as the contrast-enhanced index (CEI). Multi-detector row CT (MDCT) and volume rendering images showing the highest CEI were qualitatively evaluated. Results The CEI of all lymphatics peaked at 5–10 min. The mean CEI of TD at 10 min of group 2 (193.0 HU) and group 3 (201.5 HU) were significantly higher than that of group 1 (70.7 HU) (p = 0.024). The continuity and overall diagnostic acceptability of all lymphatic system components were better in group 3 (3.6 and 3.0, respectively) than group 1 (2.6 and 1.6) and group 2 (3.0 and 2.6) (p = 0.249 and 0.204). Conclusions The optimal imaging protocol for intranodal DCCTL could be dual-phase imaging at 5 and 10 min after the injection of 300 mgI/mL iodinated contrast media. DCCTL provided good images of lymphatics and is potentially feasible in clinical settings. Key Points • Dynamic contrast-enhanced computed tomography lymphangiography with intranodal injection of water-soluble iodine contrast media showed the highest enhancement of all lymphatics at scan delays of 5 and 10 min. • The optimal iodine concentration for intranodal dynamic contrast-enhanced computed tomography lymphangiography might be 300 mgI/mL. • Intranodal dynamic contrast-enhanced computed tomography lymphangiography provided good images of all the lymphatic system components and is potentially feasible in clinical settings.


  • Utility of microcatheter in adrenal venous sampling for primary aldosteronism

    by Yoshifumi Noda, Satoshi Goshima, Shoma Nagata, Hiroshi Kawada, Yukichi Tanahashi, Takehiro Kato, Tetsuya Suwa, Nobuyuki Kawai, Daisuke Yabe, Masayuki Matsuo

    Objective: To evaluate the utility of microcatheter in adrenal venous sampling (AVS) for assessing aldosterone hypersecretion and the laterality in patients with primary aldosteronism. Methods: This retrospective study was approved by the institutional review board of Gifu University Hospital, and written informed consent was waived. A total of 37 consecutive patients with primary aldosteronism underwent AVS by inserting a microcatheter into the right adrenal central vein (RCV), left adrenal central vein (LCV), and left adrenal common trunk (CT) followed by AVS with 5-French (5-Fr) catheter. The diagnosis of aldosterone hypersecretion was confirmed if the plasma aldosterone level after the administration of cosyntropin injection was ≥14,000 pg/ml. The laterality of aldosterone hypersecretion was determined based on the lateralized and contralateral ratios. Aldosterone hypersecretion and the laterality were diagnosed and compared based on the results obtained using 5-Fr catheter and microcatheter. Results: Plasma aldosterone levels were significantly higher in the RCV, LCV, and CT selected using microcatheter than in the right and left adrenal veins (LAVs) selected using 5-Fr catheter (p < 0.0001–0.029). More aldosterone hypersecretion from the left adrenal gland was observed in the LCV (n = 28) and CT (n = 25) selected using microcatheter compared to the LAV selected using 5-Fr catheter (n = 6) (p < 0.0001). Diagnostic changes in the laterality from unilateral to bilateral were noted in 3 (8%) patients using microcatheter. Conclusion: Microcatheter can effectively assess aldosterone hypersecretion and the laterality, especially in the LAV. Advances in knowledge: Especially for the left adrenal venous sampling, the tip of microcatheter could certainly reach the left adrenal vein orifice compared with 5-Fr catheter, therefore correct diagnosis is made and this leads to appropriate treatment.


  • Prognostic evaluation of pancreatic ductal adenocarcinoma: Associations between molecular biomarkers and CT imaging findings

    by Yoshifumi Noda, Satoshi Goshima, Yusuke Tsuji, Hiroyuki Tomita, Akira Hara, Masaya Kawaguchi, Hiroshi Kawada, Nobuyuki Kawai, Yukichi Tanahashi, Masayuki Matsuo


  • Atraumatic tension hemothorax associated with ruptured aneurysm of intercostal artery–azygous fistula: a case report

    by Takashi Nakayama, Hirofumi Uehara, Marie Osawa, Yukichi Tanahashi, Hiroshi Kondo, Masafumi Kawamura

    Atraumatic tension hemothorax is extremely rare. We report a case of 62-year-old woman presented with obstructive and hypovolemic shock status by tension hemothorax due to ruptured aneurysm of congenital intercostal artery–azygous fistula. Contrast-enhanced computed tomography and aortography revealed an aberrant 12th intercostal artery flowing into the aneurysm with a fistula draining into the azygous vein and the rupture of aneurysm. Our experience indicates that the rupture of congenital arteriovenous fistulas (AVFs) of systemic circulation in the thoracic cavity might cause not only hypovolemic shock but also atraumatic tension hemothorax. Surgery following preoperative endovascular embolization offers a feasible treatment strategy for ruptured aneurysms associated with AVFs.


  • Additional value of venous phase added to aortic CT angiography in patients with aortic aneurysm

    by Yukichi Tanahashi, Satoshi Goshima, Hiroshi Kondo, Yoshifumi Noda, Kota Sakurai, Hiroshi Kawada, Nobuyuki Kawai, Shigeru Furui, Masayuki Matsuo