Sebastian C. Bürgel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sebastian C. Bürgel has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Hierlemann
Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland
3 shared publications - Ketki Chawla
Bio Engineering Laboratory, Dept. of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland
2 shared publications - Carlos Escobedo
Department of Chemical Engineering, Queen's University, Kingston, Ontario, K7L 3N6, Canada
1 shared publication Fabian Rudolf
ETH Zurich, Department of Biosystems Science and Engineering, Computational Systems Biology Group, Basel, Switzerland
1 shared publicationFlavio C. Lombardo
Department of Medical Parasitology and Infection Biology, Swiss Tropical and Public Health Institute, Basel, Switzerland
1 shared publication- Gordana Panic
Department of Medical Parasitology and Infection Biology, Swiss Tropical and Public Health Institute, Basel, Switzerland
1 shared publication
Latest Publications
- 14 November 2018
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 3 (12) , 2613-2620
Impedance-Based Microfluidic Assay for Automated Antischistosomal Drug Screening
Schistosomiasis is a neglected tropical disease, caused by parasitic worms, which affects almost 200 million people worldwide. For over 40 years, chemotherapeutic treatment has relied on the administration of praziquantel, an efficacious drug against schistosomiasis. However, concerns about developing drug resistance require the discovery of novel drug compounds. Currently, the drug-screening process is mostly based on the visual evaluation of drug effects on worm larvae in vitro by a trained operator. This manual process is extremely labor-intensive, has limited throughput, and may be affected by subjectivity of the operator evaluation. In this paper, we introduce a microfluidic platform with integrated electrodes for the automated detection of worm larvae viability using an impedance-based approach. The microfluidic analysis unit consists of two sets of electrodes and a channel of variable geometry to enable counting and size detection of single parasite larvae and the collective evaluation of the motility of the larvae as an unbiased estimator for their viability. The current platform also allows for multiplexing of the analysis units resulting in increased throughput. We used our platform to record size and motility variations of Schistosoma mansoni larvae exposed to different concentrations of mefloquine, a drug with established in vitro antischistosomal properties. The developed platform demonstrates the potential of integrated microfluidic platforms for high-throughput antischistosomal drug screening.
- 14 November 2018
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 3 (12) , 2613-2620
Impedance-Based Microfluidic Assay for Automated Antischistosomal Drug Screening
Schistosomiasis is a neglected tropical disease, caused by parasitic worms, which affects almost 200 million people worldwide. For over 40 years, chemotherapeutic treatment has relied on the administration of praziquantel, an efficacious drug against schistosomiasis. However, concerns about developing drug resistance require the discovery of novel drug compounds. Currently, the drug-screening process is mostly based on the visual evaluation of drug effects on worm larvae in vitro by a trained operator. This manual process is extremely labor-intensive, has limited throughput, and may be affected by subjectivity of the operator evaluation. In this paper, we introduce a microfluidic platform with integrated electrodes for the automated detection of worm larvae viability using an impedance-based approach. The microfluidic analysis unit consists of two sets of electrodes and a channel of variable geometry to enable counting and size detection of single parasite larvae and the collective evaluation of the motility of the larvae as an unbiased estimator for their viability. The current platform also allows for multiplexing of the analysis units resulting in increased throughput. We used our platform to record size and motility variations of Schistosoma mansoni larvae exposed to different concentrations of mefloquine, a drug with established in vitro antischistosomal properties. The developed platform demonstrates the potential of integrated microfluidic platforms for high-throughput antischistosomal drug screening.
- Open Access
- 24 May 2018
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 4 (1) , 1-12
Integrating impedance-based growth-rate monitoring into a microfluidic cell culture platform for live-cell microscopy
Growth rate is a widely studied parameter for various cell-based biological studies. Growth rates of cell populations can be monitored in chemostats and micro-chemostats, where nutrients are continuously replenished. Here, we present an integrated microfluidic platform that enables long-term culturing of non-adherent cells as well as parallel and mutually independent continuous monitoring of (i) growth rates of cells by means of impedance measurements and of (ii) specific other cellular events by means of high-resolution optical or fluorescence microscopy. Yeast colonies were grown in a monolayer under culturing pads, which enabled high-resolution microscopy, as all cells were in the same focal plane. Upon cell growth and division, cells leaving the culturing area passed over a pair of electrodes and were counted through impedance measurements. The impedance data could then be used to directly determine the growth rates of the cells in the culturing area. The integration of multiple culturing chambers with sensing electrodes enabled multiplexed long-term monitoring of growth rates of different yeast strains in parallel. As a demonstration, we modulated the growth rates of engineered yeast strains using calcium. The results indicated that impedance measurements provide a label-free readout method to continuously monitor the changes in the growth rates of the cells without compromising high-resolution optical imaging of single cells.
- 24 May 2018
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 4 (1) , 1-12
Open AccessIntegrating impedance-based growth-rate monitoring into a microfluidic cell culture platform for live-cell microscopy
Growth rate is a widely studied parameter for various cell-based biological studies. Growth rates of cell populations can be monitored in chemostats and micro-chemostats, where nutrients are continuously replenished. Here, we present an integrated microfluidic platform that enables long-term culturing of non-adherent cells as well as parallel and mutually independent continuous monitoring of (i) growth rates of cells by means of impedance measurements and of (ii) specific other cellular events by means of high-resolution optical or fluorescence microscopy. Yeast colonies were grown in a monolayer under culturing pads, which enabled high-resolution microscopy, as all cells were in the same focal plane. Upon cell growth and division, cells leaving the culturing area passed over a pair of electrodes and were counted through impedance measurements. The impedance data could then be used to directly determine the growth rates of the cells in the culturing area. The integration of multiple culturing chambers with sensing electrodes enabled multiplexed long-term monitoring of growth rates of different yeast strains in parallel. As a demonstration, we modulated the growth rates of engineered yeast strains using calcium. The results indicated that impedance measurements provide a label-free readout method to continuously monitor the changes in the growth rates of the cells without compromising high-resolution optical imaging of single cells.
- 1 April 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 210, 82-90
On-chip electroporation and impedance spectroscopy of single-cells
- 1 April 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 210, 82-90
On-chip electroporation and impedance spectroscopy of single-cells