Shahryar Malekie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shahryar Malekie has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Sedigheh Kashian
Radiation Application Research School, Nuclear Science and Technology Research Institute, Karaj, Iran
9 shared publicationsSuffian Mohamad Tajudin
School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin (UniSZA), Terengganu, Malaysia
5 shared publicationsAmir Veiskarami
Department of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
4 shared publicationsArmin Mosayebi
4 shared publicationsDariush Sardari
Tehran University of Medical Sciences, Tehran, Iran
4 shared publications- Mohammad Amin Hosseini
Shiraz University of Medical Sciences
4 shared publications
Latest Publications
- Open Access
- 18 October 2026
- Published by Springer Nature in Scientific Reports
Investigation of the dosimetric characteristics of real-time silicone/Bi2O3 nanocomposites for the diagnostic level X-rays
This study presents the development of high-sensitivity real-time X-ray dosimeters based on room-temperature-vulcanized (RTV-2) silicone nanocomposites incorporating 0–60 wt% Bi 2 O 3 nanoparticles, fabricated via solution casting. Structural and morphological characterization using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) with elemental mapping, and elemental analysis confirmed the uniform dispersion of monoclinic Bi 2 O 3 nanorods within the amorphous RTV-2 matrix. Complementary Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, and thermogravimetric analysis (TGA) validated the chemical integrity, thermal stability, and mechanical robustness of the resulting nanocomposites. Dosimetric performance was investigated under diagnostic-range X-ray exposure using a COMET MXR 320/26 source (dose rates: 2.8–12 mGy/min). The I-V characteristics at 4.8 mGy/min exhibited a highly linear response over ± 400 V. At 400 V, the photocurrent increased from ~ 0.56 nA (pure RTV-2) to ~ 1.66 nA (60 wt% Bi 2 O 3 ), corresponding to a ~ 3-fold enhancement in photocurrent. The devices demonstrated good short-term repeatability (standard deviation of 2.3% over ten consecutive measurements) and a signal-to-noise ratio (SNR) of up to ~ 1900 at 400 V. Compared with reported values for commercial MOSFET dosimeters (~ 0.1–1 nA/mGy) and previously reported Bi 2 O 3 -polymer systems, the developed nanocomposites exhibit a higher competitive normalized sensitivity (~ 0.35 nA/(mGy/min), or 878 nC·mGy⁻ 1 ·cm⁻ 3 on a volumetric basis), demonstrating their suitability as lead-free alternatives for low-dose, real-time diagnostic X-ray dosimetry; further evaluation of long-term stability and mechanical durability is needed to establish clinical applicability.
- 18 October 2026
- Published by Springer Nature in Scientific Reports
Open AccessInvestigation of the dosimetric characteristics of real-time silicone/Bi2O3 nanocomposites for the diagnostic level X-rays
This study presents the development of high-sensitivity real-time X-ray dosimeters based on room-temperature-vulcanized (RTV-2) silicone nanocomposites incorporating 0–60 wt% Bi 2 O 3 nanoparticles, fabricated via solution casting. Structural and morphological characterization using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) with elemental mapping, and elemental analysis confirmed the uniform dispersion of monoclinic Bi 2 O 3 nanorods within the amorphous RTV-2 matrix. Complementary Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, and thermogravimetric analysis (TGA) validated the chemical integrity, thermal stability, and mechanical robustness of the resulting nanocomposites. Dosimetric performance was investigated under diagnostic-range X-ray exposure using a COMET MXR 320/26 source (dose rates: 2.8–12 mGy/min). The I-V characteristics at 4.8 mGy/min exhibited a highly linear response over ± 400 V. At 400 V, the photocurrent increased from ~ 0.56 nA (pure RTV-2) to ~ 1.66 nA (60 wt% Bi 2 O 3 ), corresponding to a ~ 3-fold enhancement in photocurrent. The devices demonstrated good short-term repeatability (standard deviation of 2.3% over ten consecutive measurements) and a signal-to-noise ratio (SNR) of up to ~ 1900 at 400 V. Compared with reported values for commercial MOSFET dosimeters (~ 0.1–1 nA/mGy) and previously reported Bi 2 O 3 -polymer systems, the developed nanocomposites exhibit a higher competitive normalized sensitivity (~ 0.35 nA/(mGy/min), or 878 nC·mGy⁻ 1 ·cm⁻ 3 on a volumetric basis), demonstrating their suitability as lead-free alternatives for low-dose, real-time diagnostic X-ray dosimetry; further evaluation of long-term stability and mechanical durability is needed to establish clinical applicability.
- 18 June 2026
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (7) , 1-12
Dose assessment in eye lens and larynx for periapical and OPG imaging using a bismuth based thyroid collar and Rando phantom
- 18 June 2026
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (7) , 1-12
Dose assessment in eye lens and larynx for periapical and OPG imaging using a bismuth based thyroid collar and Rando phantom
- Open Access
- 29 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Evaluation of a flexible thyroid shield in dental panoramic radiography utilizing bismuth oxide silicone rubber composite and Rando phantom
Initially, micro and nano bismuth oxide/ silicone rubber (Bi2O3/SR) composites at concentration of 70 wt% were fabricated. Analyses including XRD, SEM, EDS-Map, and TGA were performed on the samples, which indicated the dispersion of bismuth oxide micro and nano particles in the polymer matrix. Subsequently, the initial irradiation tests of the samples were performed by X-ray tube 60 kV at the SSDL of Iran. Results showed that there was no significant difference between the shielding effectiveness of micro and nano composites at 70 wt%. Therefore, in the final phase, considering economic considerations, a thyroid shield with a strap length of 58 cm, width of 23 cm, strap width of 6.4 cm, and length of 14 cm with thickness of 4 mm was manufactured using micro particles of Bi2O3 in the SR matrix. Then, radiation tests of the composite thyroid shield were conducted in an Orthopantomogram (OPG) radiology using the TLD-GR200 dosimeters and head-neck part of an adult male Rando phantom at 75 kV, 13 mA, with exposure time of 14.1 s. Results reveal that the thyroid gland received an absorbed dose of 386.6 ± 219.8 µSv, 19.0 ± 12.4 µSv, and 37.9 ± 18.7 µSv for unshielded, composite shield, and commercial thyroid collar (equivalent to 0.5 mm Pb), respectively. This shows a 95.1% reduction in dose with composite shielding, which is 5.4% more effective than commercial thyroid collar.
- 29 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessEvaluation of a flexible thyroid shield in dental panoramic radiography utilizing bismuth oxide silicone rubber composite and Rando phantom
Initially, micro and nano bismuth oxide/ silicone rubber (Bi2O3/SR) composites at concentration of 70 wt% were fabricated. Analyses including XRD, SEM, EDS-Map, and TGA were performed on the samples, which indicated the dispersion of bismuth oxide micro and nano particles in the polymer matrix. Subsequently, the initial irradiation tests of the samples were performed by X-ray tube 60 kV at the SSDL of Iran. Results showed that there was no significant difference between the shielding effectiveness of micro and nano composites at 70 wt%. Therefore, in the final phase, considering economic considerations, a thyroid shield with a strap length of 58 cm, width of 23 cm, strap width of 6.4 cm, and length of 14 cm with thickness of 4 mm was manufactured using micro particles of Bi2O3 in the SR matrix. Then, radiation tests of the composite thyroid shield were conducted in an Orthopantomogram (OPG) radiology using the TLD-GR200 dosimeters and head-neck part of an adult male Rando phantom at 75 kV, 13 mA, with exposure time of 14.1 s. Results reveal that the thyroid gland received an absorbed dose of 386.6 ± 219.8 µSv, 19.0 ± 12.4 µSv, and 37.9 ± 18.7 µSv for unshielded, composite shield, and commercial thyroid collar (equivalent to 0.5 mm Pb), respectively. This shows a 95.1% reduction in dose with composite shielding, which is 5.4% more effective than commercial thyroid collar.
- Open Access
- 30 April 2025
- Published by SCI AND TECH UNIVERSAL INC in Journal of Nuclear Research and Applications
- p. e1730
A comparative study on electrical parameters of a Si/63Ni betavoltaic battery using the MCNP code, analytical and experimental data
Betavoltaic batteries offer a promising alternative to conventional energy sources, ensuring a continuous power supply in various environments. In this simulation, the transport of beta particles of Nickel-63 (63Ni) was studied in silicon, at average energy of 17.4 keV. Assessment of energy deposition in silicon at varying depths was conducted with the MCNP code, resulting in the determination of the electron-hole pair generation rate. Subsequently, the output performance of the battery including short-circuit current (Isc), open-circuit voltage (Voc), fill factor (FF), maximum electrical power (Pmax), and efficiency (η) were assessed for two levels of activity, namely 0.25, and 1 mCi. For beta particles with energy of 17.4 keV, in depth of 2 μm, the highest energy deposition was achieved, however there was a notable probability of energy deposition in the initial layers of silicon up to 3 μm. Results of this simulation were compared with other findings both analytical and experimental data, in which exhibited the discrepancy less than 10%, and 14% with the analytical data related to Isc and Voc, respectively, and around 15% discrepancy with experimental one. However, there was a notable difference between the simulations and experimental data, particularly for Voc attributing to self-absorption phenomenon for 63Ni beta emitter source.
- 30 April 2025
- Published by SCI AND TECH UNIVERSAL INC in Journal of Nuclear Research and Applications
- p. e1730
Open AccessA comparative study on electrical parameters of a Si/63Ni betavoltaic battery using the MCNP code, analytical and experimental data
Betavoltaic batteries offer a promising alternative to conventional energy sources, ensuring a continuous power supply in various environments. In this simulation, the transport of beta particles of Nickel-63 (63Ni) was studied in silicon, at average energy of 17.4 keV. Assessment of energy deposition in silicon at varying depths was conducted with the MCNP code, resulting in the determination of the electron-hole pair generation rate. Subsequently, the output performance of the battery including short-circuit current (Isc), open-circuit voltage (Voc), fill factor (FF), maximum electrical power (Pmax), and efficiency (η) were assessed for two levels of activity, namely 0.25, and 1 mCi. For beta particles with energy of 17.4 keV, in depth of 2 μm, the highest energy deposition was achieved, however there was a notable probability of energy deposition in the initial layers of silicon up to 3 μm. Results of this simulation were compared with other findings both analytical and experimental data, in which exhibited the discrepancy less than 10%, and 14% with the analytical data related to Isc and Voc, respectively, and around 15% discrepancy with experimental one. However, there was a notable difference between the simulations and experimental data, particularly for Voc attributing to self-absorption phenomenon for 63Ni beta emitter source.
- 6 February 2025
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 27 (2) , 1-13
Analysis of the electromagnetic interference shielding effectiveness of polystyrene-SWCNT nanocomposite in X-band frequencies
- 6 February 2025
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 27 (2) , 1-13
Analysis of the electromagnetic interference shielding effectiveness of polystyrene-SWCNT nanocomposite in X-band frequencies
- 18 November 2024
- Published by Elsevier in Radiation Measurements
- Vol. 180
Exploration of dosimetry characteristics of PVA/MWCNT-OH nanocomposite for intraoperative electron radiotherapy
- 18 November 2024
- Published by Elsevier in Radiation Measurements
- Vol. 180
Exploration of dosimetry characteristics of PVA/MWCNT-OH nanocomposite for intraoperative electron radiotherapy
- Open Access
- 3 October 2024
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 29 (4) , 413-425
Dosimetry characteristics of polycarbonate/bismuth oxide nanocomposite for real-time application in the field of gamma-rays
Background: Polymer-carbon nanostructures have previously been introduced for dosimetry of gamma rays with potential application in radiotherapy. In this research work, bismuth oxide (Bi2O3) nanoparticles were added into the amorphous polycarbonate (PC) matrix to enhance the probability of the photoelectric effect and dosimetry response in parallel. Materials and methods: PC/Bi2O3 nanocomposites at concentrations of 0, 5, 20, 40, and 50 Bi2O3 wt% were fabricated via a solution method. Afterward, the samples were irradiated by gamma rays of cobalt-60 (60Co) related to Picker V-9, and Therarton-780 machines at 30–254 mGy/min. Dosimetric characteristics were carried out including linearity, angular dependency, energy, bias-polarity, field size, and repeatability. Results: Field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) analyses exhibited an appropriate dispersion state. The dosimeter response was linear at 30–254 mGy/min for the all samples. The 50 wt% sample exhibited the highest sensitivity at 4.61 nC/mGy. A maximum angular variation of approximately 15% was recorded in normal beam incidence. The energy dependence at two energies of 662 and 1250 keV was obtained as 0.7%. Bias-polarity for the 40, and 50 wt% samples at 400 V were measured as 15.9% and 9.0%, respectively. The dosimetry response was significantly dependent on the radiation field size. Also, the repeatability of the dosimeter response was measured as 0.4%. Conclusions: Considering the dosimetry characteristics of PC-Bi2O3 nanocomposites, and appropriate correction factors, this material can be used as a real-time dosimeter for the photon fields at therapy level. Keywords: dosimetry gamma rays PC/Bi2O3 nanocomposite dose rate therapy level
- 3 October 2024
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 29 (4) , 413-425
Open AccessDosimetry characteristics of polycarbonate/bismuth oxide nanocomposite for real-time application in the field of gamma-rays
Background: Polymer-carbon nanostructures have previously been introduced for dosimetry of gamma rays with potential application in radiotherapy. In this research work, bismuth oxide (Bi2O3) nanoparticles were added into the amorphous polycarbonate (PC) matrix to enhance the probability of the photoelectric effect and dosimetry response in parallel. Materials and methods: PC/Bi2O3 nanocomposites at concentrations of 0, 5, 20, 40, and 50 Bi2O3 wt% were fabricated via a solution method. Afterward, the samples were irradiated by gamma rays of cobalt-60 (60Co) related to Picker V-9, and Therarton-780 machines at 30–254 mGy/min. Dosimetric characteristics were carried out including linearity, angular dependency, energy, bias-polarity, field size, and repeatability. Results: Field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) analyses exhibited an appropriate dispersion state. The dosimeter response was linear at 30–254 mGy/min for the all samples. The 50 wt% sample exhibited the highest sensitivity at 4.61 nC/mGy. A maximum angular variation of approximately 15% was recorded in normal beam incidence. The energy dependence at two energies of 662 and 1250 keV was obtained as 0.7%. Bias-polarity for the 40, and 50 wt% samples at 400 V were measured as 15.9% and 9.0%, respectively. The dosimetry response was significantly dependent on the radiation field size. Also, the repeatability of the dosimeter response was measured as 0.4%. Conclusions: Considering the dosimetry characteristics of PC-Bi2O3 nanocomposites, and appropriate correction factors, this material can be used as a real-time dosimeter for the photon fields at therapy level. Keywords: dosimetry gamma rays PC/Bi2O3 nanocomposite dose rate therapy level
- 22 June 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 223
Physicochemical characterization of 10W-40 engine oil irradiated with gamma-rays
- 22 June 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 223
Physicochemical characterization of 10W-40 engine oil irradiated with gamma-rays
- 23 February 2024
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 112 (4) , 255-259
Investigation of the dose-response linearity of guar gum for gamma-ray dosimetry at radiation processing levels using Raman spectroscopy
In this experimental work, guar gum powder was exposed to gamma radiation from a 60Co source at absorbed doses of 0, 10, 30, 50, 80, 100, 150 kGy at dose rate of 1.62 Gy/s. Raman spectroscopy was applied to measure the intensity of the samples ranging from of 500–4600 cm−1. The intensity versus Raman shift was evaluated at 3800–4000 cm−1. Then the curve was fitted linearly. The slope of the lines was determined in each absorbed dose. Results indicated that the absolute values of the slope of each line were enhanced with increasing the absorbed dose. This trend was linear within the absorbed dose ranging from of 0–50 kGy, in which was saturated after 80 kGy. Results showed that guar gum can be applied as a passive dosimeter at radiation processing level.
- 23 February 2024
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 112 (4) , 255-259
Investigation of the dose-response linearity of guar gum for gamma-ray dosimetry at radiation processing levels using Raman spectroscopy
In this experimental work, guar gum powder was exposed to gamma radiation from a 60Co source at absorbed doses of 0, 10, 30, 50, 80, 100, 150 kGy at dose rate of 1.62 Gy/s. Raman spectroscopy was applied to measure the intensity of the samples ranging from of 500–4600 cm−1. The intensity versus Raman shift was evaluated at 3800–4000 cm−1. Then the curve was fitted linearly. The slope of the lines was determined in each absorbed dose. Results indicated that the absolute values of the slope of each line were enhanced with increasing the absorbed dose. This trend was linear within the absorbed dose ranging from of 0–50 kGy, in which was saturated after 80 kGy. Results showed that guar gum can be applied as a passive dosimeter at radiation processing level.