AKAsif Khalid

Asif Khalid

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Asif Khalid has a total of 151 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Natural history of spontaneous pancreatic portal vein fistulae: A systematic review of the literature

    by Natalie E. Griffin, Morgan Ferrell, Robert Feldman, Anil K. Dasyam, Adam Slivka, Asif Khalid, Harkirat Singh, Charles Gabbert, Rohit Das, Sultan Mahmood, et al.


  • Open Access

    External nasal dilator decreases N95 respirator-related respiratory effort and symptoms in gastrointestinal endoscopy unit staff

    by Asif Khalid, Christopher Thomas, Michael Kingsley, Kishore Vipperla, Jeffrey Dueker, Christianna Kreiss, Anna Evans Phillips, Rohit Das, Kenneth Fasanella, James Ibinson, et al.

    Background and study aims N95-filtering facepiece respirators (FFR) use is associated with physiological changes and symptoms due to impaired nasal airflow and increased breathing resistance. We prospectively studied the effect of using an external nasal dilator (END) in gastroenterology laboratory (gastrointestinal lab) staff using N95FFR. Patients and methods N95FFR qualitative saccharine fit testing was performed on study participants with and without an END. Prospective data collection and comparisons included: 1) survey of perceived symptoms and difficulty of performing one day of gastrointestinal procedures with N95FFR and 1 day of gastrointestinal procedures with END plus N95FFR in random sequence; and 2) vitals and respiratory belt plethysmography in ten gastroenterologists performing simulated colonoscopy while wearing a surgical mask (SM), N95FFR plus SM, END plus N95FFR plus SM for 20 minutes each in random sequence and rapid succession. Results Twenty-nine of 31 participants passed the N95FFR and the END plus N95FFR fit test. Twenty-two participants (12 physicians; 11 males; mean age 44.1 years, range 31–61) performed 1 day of gastrointestinal procedures with an N95FFR and 1 day of gastrointestinal procedures with an END plus N95FFR. Significantly less difficulty with nasal breathing and severity of symptoms including breathing difficulty, headache, fatigue and frustration, occurred while using an END plus N95FFR. Respiratory plethysmography peak-to-trough measurement showed an increase during the N95FFR stage compared to the END plus N95FFR stage and the SM stage. Conclusions N95FFR related respiratory changes and symptom development may be mitigated by END use.

  • High Rate of Inappropriate Fecal Immunochemical Testing at a Large Veterans Affairs Health Care System

    by Asif Khalid

    Colonoscopies and annual fecal immunochemical tests (FITs), are 2 of the preferred modalities for colorectal cancer (CRC) screening endorsed by the US Preventiv


  • Open Access

    Safety and efficacy of band ligation and auto-amputation as adjunct to EMR of colonic large laterally spreading tumors, and polyps not amenable to routine polypectomy

    by Stephanie Romutis, Bassem Matta, Jonathan Ibinson, John Hileman, Smiljana Istvanic, Asif Khalid

    The safety and efficacy of colonic band ligation and auto-amputation (1) as adjunct to endoscopic mucosal resection of large laterally spreading tumors and (2) for polyps not amenable to routine polypectomy due to polyp burden or difficult location remain unknown. An institutional review board–approved retrospective single-institution study was undertaken of patients undergoing colonic band ligation and auto-amputation from 2014 to date. Patients with indications of ‘endoscopic mucosal resection for laterally spreading tumors’ and ‘polyp not amenable to snare polypectomy’ were included in the study. Data were collected on patient demographics, colonoscopy details (laterally spreading tumors/polyp characteristics, therapies applied, complications), pathology results, and follow-up (polyp eradication based on endoscopic appearance and biopsy results). Patients undergoing endoscopic mucosal resection for laterally spreading tumors: Thirty-two patients (31 males, aged 68 ± 9.17 years) underwent endoscopic mucosal resection-band ligation and auto-amputation of 34 laterally spreading tumors (40 ± 10.9 mm). A median of 2 ± 1.09 bands were placed. Follow-up colonoscopy and biopsy results confirmed complete eradication in 21 laterally spreading tumors (70%). Nine (30%) laterally spreading tumors required additional endoscopic therapy to achieve complete eradication. Four (13%) patients underwent surgery for cancer, and two of them had resection specimens negative for cancer or residual adenoma. One patient suffered post-polypectomy syndrome. Patients undergoing band ligation and auto-amputation for polyps not amenable to snare polypectomy: Seven patients underwent band ligation and auto-amputation due to serrated polyposis syndrome (one patient) and innumerable polyps, or polyps in difficult locations (extension into diverticula: two patients; terminal ileum: two patients; appendiceal orifice: one patient; anal canal: one patient). The patient with serrated polyposis syndrome achieved dramatic decrease in polyp burden, but not eradication. Follow-up in five of the six remaining patients documented polyp eradication. The patient with serrated polyposis syndrome suffered from rectal pain and tenesmus following placement of 18 bands. Band ligation and auto-amputation in the colon may be a safe and effective adjunct to current endoscopic mucosal resection and polypectomy methods and warrants further study. Colonoscopy with rubber band placement to aid in complete removal of large polyps and polyps in technically challenging locations Colonoscopy is a commonly performed procedure for the early detection of colon and rectal cancer, and prevention through polyp removal.During colonoscopy, sometimes situations are encountered making polyp removal difficult. These can include the presence of larger polyps or the location of a polyp in an area that makes removal technically challenging or high risk.A particularly challenging situation arises when after extensive effort there is still polyp tissue remaining that cannot be removed using routine techniques. We are interested in exploring a technique which involves the placement of a rubber band after sucking a small area of the colon lining into a cap loaded onto the tip of the colonoscope. With time the rubber band strangulates the tissue and falls off along with captured tissue and passes out of the colon naturally.To assess the effectives of this technique we studied patients that have undergone this procedure at our GI unit. We identified 32 patients with 34 large polyps between 4cm to 6cm that we placed rubber bands on polyp tissue after we were unable to completely remove the polyp. On their follow up colonoscopy, complete polyp removal was successful in 21 polyps. We were also able to achieve complete polyp removal in 9 of the remaining large polyps after additional treatment. Four patients underwent surgery because cancer was found in analysis of polyp tissue.In 5 of 6 patients with polyps in difficult locations (e.g. partly within the lumen of the appendix), placement of a rubber band led to complete removal of polyp tissue.Two patients in our study population had mild adverse events that were managed with simple measures.We believe our results show promise for our described technique and this technique should be tested in larger studies.


  • Mo1294 UNIQUE DELETERIOUS GENE MUTATIONS EXCLUSIVELY ASSOCIATED WITH PREMALIGNANT AND MALIGNANT IPMN

    by Asif Khalid, Kevin McGrath, Georgios I. Papachristou, Kenneth Fasanella, Jennifer Chennat, Aatur Singhi, Adam Slivka, Maureen Lyons, Chris Drescher, James Hirmas, et al.

  • Sa1037 RISK OF UNRECOGNIZED ENDOSCOPIST FACIAL SPLASH DURING ENDOSCOPY

    by Elyse Johnston, Nadia F. HabibBein, Jeffrey Dueker, Barbara Quiroz, Enrico Corsaro, Megan Ambrogio, Michael Kingsley, Georgios I. Papachristou, Christianna Kreiss, Asif Khalid

  • Sa1380 - A Decrease in T-Stage from Eus Guided Diagnosis to Time of Resection is Predictive of Overall Survival in Patients with Pancreatic Ductal Adenocarcinoma

    by Rohit Das, Natalie Seiser, Kevin McGrath, Randall Brand, Jennifer S. Chennat, Kenneth Fasanella, Asif Khalid, Georgios I. Papachristou, Adam Slivka, Nathan Bahary, et al.

  • THE DIAGNOSTIC ACCURACY OF CARCINOEMBRYONIC ANTIGEN IN DIFFERENTIATING MUCINOUS AND NON-MUCINOUS PANCREATIC CYSTIC NEOPLASMS – A SYSTEMATIC REVIEW AND INDIVIDUAL PATIENT DATA META-ANALYSIS

    by Ncm van Huijgevoort, Sa Hoogenboom, Sj Lekkerkerker, Topazian, V Chandrasekhara, G Morris-Stiff, Ma Al-Haddad, Kw Oppong, A Khalid, M del Chiaro, et al.

    Aims: Distinction between the different types of pancreatic cystic neoplasms (PCNs) is essential, since non-mucinous cysts are benign without need for surveillance, whereas mucinous cysts are considered premalignant and require either surveillance or surgical resection. We aimed to systematically review the diagnostic accuracy of CEA> 192 ng/mL in differentiating mucinous and non-mucinous PCNs and to determine the optimal cut-off value of CEA using individual patient data meta-analysis. Methods: A systematic literature search was performed in PubMed, EMBASE and the Cochrane Library for studies investigating the diagnostic accuracy of CEA> 192 ng/mL in differentiating mucinous and non-mucinous PCNs. Individual data of patients with (surgical) histological confirmation of the type of PCNs were extracted from the included studies to determine the optimal cut-off value of CEA. Results: Fourteen studies were included, with a total of 1088 patients. Meta-analysis showed that the pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of CEA> 192 ng/mL for the differentiation between mucinous and non-mucinous PCNs were: 67% (95% confidence interval (CI), 63%-70%); 76% (95% CI 71%-80%); 2.80 (95% CI 1.68 – 4.68); and 0.45 (95% CI 0.35 – 0.58), respectively. Individual data from seven studies with a total of 365 patients were extracted to determine the optimal cut-off value of CEA. A cut-off value of 20 ng/mL achieved the highest diagnostic accuracy for differentiating between mucinous and non-mucinous PCNs with pooled sensitivity of 91% (95% CI 88%-94%) and specificity of 85% (95% CI 72%-93%). With CEA> 20 ng/mL, 27 (7.4%) mucinous cysts would have been missed, whereas with a CEA> 192 ng/mL, 108 (29.6%) mucinous cyst would have been missed. Conclusions: Pancreatic cyst fluid CEA can accurately differentiate histologically verified mucinous from non-mucinous PCNs with an optimal cut-off value of 20 ng/mL