Ilaria Mattei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ilaria Mattei has a total of 382 co-authors. Here are the top co-authors by number of shared publications:
- Michela Marafini
Museo Storico della Fisica e Centro Studi e Ricerche “Enrico Fermi”, Piazza del Viminale 1, 00184 Roma, Italy
37 shared publications - Vincenzo Patera
Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma, Roma, Italy
35 shared publications - Cecilia Voena
Department of Physics, University of Rome, La Sapienza, Piazzale A. Moro, 2, 00185, Rome, Italy
25 shared publications - Alessandra Sarti
Sapienza, University of Rome, Department of Scienze di Base e Applicate all'Ingegneria, Rome, Italy; National Institute of Nuclear Physics, INFN, Section of Rome I, Rome, Italy
20 shared publications - Riccardo Faccini
Universita degli Studi di Roma La Sapienza Dipartimento di Fisica
16 shared publications - Adalberto Sciubba
Sezione INFN di Roma La Sapienza, Roma, Italy
15 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 2 December 2024
- Published by EDP Sciences in EPJ Nuclear Sciences & Technologies
- Vol. 10, 16
The FLUKA code: Overview and new developments
The FLUKA Monte Carlo Radiation Transport and Interaction code package is widely used to simulate the interaction of particles with matter in a variety of fields, including high energy physics, space radiation, medical applications, radiation protection and shielding assessments, accelerator studies, astrophysical studies and well logging. This paper gives a brief overview of the FLUKA program and describes recent developments, in particular, improvements in the modelling of particle interactions and transport are described in detail. In addition, an overview of selected applications is given.
- 2 December 2024
- Published by EDP Sciences in EPJ Nuclear Sciences & Technologies
- Vol. 10, 16
Top Cited PapersOpen AccessThe FLUKA code: Overview and new developments
The FLUKA Monte Carlo Radiation Transport and Interaction code package is widely used to simulate the interaction of particles with matter in a variety of fields, including high energy physics, space radiation, medical applications, radiation protection and shielding assessments, accelerator studies, astrophysical studies and well logging. This paper gives a brief overview of the FLUKA program and describes recent developments, in particular, improvements in the modelling of particle interactions and transport are described in detail. In addition, an overview of selected applications is given.
- 6 August 2021
- Published by IOP Publishing in Physica Scripta
- Vol. 96 (11) , 114013
Enhancing the understanding of fragmentation processes in hadrontherapy and radioprotection in space with the FOOT experiment
During proton and carbon ions cancer treatment, nuclear interactions of the beam nuclei with the patient tissues always occur: the former leads to target fragmentation only, the latter to both projectile and target fragments production. In proton therapy the low-energy, high-charge and therefore short-range fragments produced along the beam path in the target fragmentation process may have higher biological effectiveness compared to protons, resulting in a not negligible effect on the delivered dose in a region before the tumor site. In carbon treatments the long range of projectile fragments results in a dose deposition in the healthy tissues behind the tumor site. Therefore, precise fragmentation cross section data would be of great importance to further optimize treatments. At the same time, such data would help improving the design of the shielding of spaceships, especially in view of long distance travels (i.e. Mars human exploration). In fact, nuclear fragmentation occurring between the space background radiation and spacecrafts materials changes the composition of the radiation field and thus the dose received by the astronauts. The FOOT (FragmentatiOn Of Target) experiment has been designed to investigate nuclear fragmentation processes of interest for particle therapy and space radiation protection with a precision in the cross section measurements around 5%. In this work the physics motivations of FOOT and the final design of the experiment will be presented. A performances study of the electronic setup based on FLUKA Monte Carlo simulations and a preliminary analysis of experimental data are reported as well.
- 6 August 2021
- Published by IOP Publishing in Physica Scripta
- Vol. 96 (11) , 114013
Enhancing the understanding of fragmentation processes in hadrontherapy and radioprotection in space with the FOOT experiment
During proton and carbon ions cancer treatment, nuclear interactions of the beam nuclei with the patient tissues always occur: the former leads to target fragmentation only, the latter to both projectile and target fragments production. In proton therapy the low-energy, high-charge and therefore short-range fragments produced along the beam path in the target fragmentation process may have higher biological effectiveness compared to protons, resulting in a not negligible effect on the delivered dose in a region before the tumor site. In carbon treatments the long range of projectile fragments results in a dose deposition in the healthy tissues behind the tumor site. Therefore, precise fragmentation cross section data would be of great importance to further optimize treatments. At the same time, such data would help improving the design of the shielding of spaceships, especially in view of long distance travels (i.e. Mars human exploration). In fact, nuclear fragmentation occurring between the space background radiation and spacecrafts materials changes the composition of the radiation field and thus the dose received by the astronauts. The FOOT (FragmentatiOn Of Target) experiment has been designed to investigate nuclear fragmentation processes of interest for particle therapy and space radiation protection with a precision in the cross section measurements around 5%. In this work the physics motivations of FOOT and the final design of the experiment will be presented. A performances study of the electronic setup based on FLUKA Monte Carlo simulations and a preliminary analysis of experimental data are reported as well.
- 11 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (2) , 269-282
Measurement of 12C Fragmentation Cross Sections on C, O, and H in the Energy Range of Interest for Particle Therapy Applications
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumour and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene (plastic scintillator, CbHa) allowed to measure fragments production cross sections, exploiting a Time of Flight (ToF) technique. Plastic scintillator detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 and 60 degrees with respect to the beam direction. The measured proton, deuteron and triton differential production cross sections on C, O and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.
- 11 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (2) , 269-282
Measurement of 12C Fragmentation Cross Sections on C, O, and H in the Energy Range of Interest for Particle Therapy Applications
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumour and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene (plastic scintillator, CbHa) allowed to measure fragments production cross sections, exploiting a Time of Flight (ToF) technique. Plastic scintillator detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 and 60 degrees with respect to the beam direction. The measured proton, deuteron and triton differential production cross sections on C, O and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.
- 1 August 2019
- Published by Elsevier in Physica Medica
- Vol. 64, 45-53
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles
- 1 August 2019
- Published by Elsevier in Physica Medica
- Vol. 64, 45-53
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles
- 1 December 2018
- Published by Elsevier in Radiation Measurements
- Vol. 119, 144-149
Characterisation of the MONDO detector response to neutrons by means of a FLUKA Monte Carlo simulation
- 1 December 2018
- Published by Elsevier in Radiation Measurements
- Vol. 119, 144-149
Characterisation of the MONDO detector response to neutrons by means of a FLUKA Monte Carlo simulation
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2054-2060
Scintillating Fiber Devices for Particle Therapy Applications
Particle therapy (PT) is a radiation therapy technique in which solid tumors are treated with charged ions and exploits the achievable highly localized dose delivery, allowing to spare healthy tissues and organs at risk. The development of a range monitoring technique to be used online, during the treatment, capable to reach millimetric precision is considered one of the important steps toward an optimization of the PT efficacy and of the treatment quality. To this aim, charged secondary particles produced in the nuclear interactions between the beam particles and the patient tissues can be exploited. Besides charged secondaries, neutrons are also produced in nuclear interactions. The secondary neutron component might cause an undesired and not negligible dose deposition far away from the tumor region, enhancing the risk of secondary malignant neoplasms that can develop even years after the treatment. An accurate neutron characterization (flux, energy and emission profile) is, hence, needed for a better evaluation of long-term complications. In this contribution, two tracker detectors, both based on scintillating fibers, are presented. The first one, named dose profiler (DP), is planned to be used as a beam range monitor in PT treatments with heavy ion beams, exploiting the charged secondary fragments production. The DP is currently under development within the Innovative Solutions for In-Beam DosimEtry in Hadrontherapy project. The second one is dedicated to the measurement of the fast and ultrafast neutron component produced in PT treatments, in the framework of the monitor for neutron dose in hadrontherapy project. Results of the first calibration tests performed at the Trento Protontherapy Center and at Centro Nazionale di Adroterapia Oncologica (Italy) are reported, as well as simulation studies.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2054-2060
Scintillating Fiber Devices for Particle Therapy Applications
Particle therapy (PT) is a radiation therapy technique in which solid tumors are treated with charged ions and exploits the achievable highly localized dose delivery, allowing to spare healthy tissues and organs at risk. The development of a range monitoring technique to be used online, during the treatment, capable to reach millimetric precision is considered one of the important steps toward an optimization of the PT efficacy and of the treatment quality. To this aim, charged secondary particles produced in the nuclear interactions between the beam particles and the patient tissues can be exploited. Besides charged secondaries, neutrons are also produced in nuclear interactions. The secondary neutron component might cause an undesired and not negligible dose deposition far away from the tumor region, enhancing the risk of secondary malignant neoplasms that can develop even years after the treatment. An accurate neutron characterization (flux, energy and emission profile) is, hence, needed for a better evaluation of long-term complications. In this contribution, two tracker detectors, both based on scintillating fibers, are presented. The first one, named dose profiler (DP), is planned to be used as a beam range monitor in PT treatments with heavy ion beams, exploiting the charged secondary fragments production. The DP is currently under development within the Innovative Solutions for In-Beam DosimEtry in Hadrontherapy project. The second one is dedicated to the measurement of the fast and ultrafast neutron component produced in PT treatments, in the framework of the monitor for neutron dose in hadrontherapy project. Results of the first calibration tests performed at the Trento Protontherapy Center and at Centro Nazionale di Adroterapia Oncologica (Italy) are reported, as well as simulation studies.
- 1 March 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (5) , 055018
Secondary radiation measurements for particle therapy applications: charged particles produced by 4 He and 12 C ion beams in a PMMA target at large angle
Proton and carbon ion beams are used in the clinical practice for external radiotherapy treatments achieving, for selected indications, promising and superior clinical results with respect to x-ray based radiotherapy. Other ions, like 4 H e have recently been considered as projectiles in particle therapy centres and might represent a good compromise between the linear energy transfer and the radiobiological effectiveness of 12 C ion and proton beams, allowing improved tumour control probability and minimising normal tissue complication probability. All the currently used p, 4 H e and 12 C ion beams allow achieving sharp dose gradients on the boundary of the target volume, however the accurate dose delivery is sensitive to the patient positioning and to anatomical variations with respect to photon therapy. This requires beam range and/or dose release measurement during patient irradiation and therefore the development of dedicated monitoring techniques. All the proposed methods make use of the secondary radiation created by the beam interaction with the patient and, in particular, in the case of 12 C ion beams are also able to exploit the significant charged radiation component. Measurements performed to characterise the charged secondary radiation created by 12 C and 4 H e particle therapy beams are reported. Charged secondary yields, energy spectra and emission profiles produced in a poly-methyl methacrylate (PMMA) target by 4 H e and 12 C beams of different therapeutic energies were measured at 60° and 90° with respect to the primary beam direction. The secondary yield of protons produced along the primary beam path in a PMMA target was obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The obtained measurements are in agreement with results reported in the literature and suggests the feasibility of range monitoring based on charged secondary particle detection: the implications for particle therapy monitoring applications are also discussed.
- 1 March 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (5) , 055018
Secondary radiation measurements for particle therapy applications: charged particles produced by 4 He and 12 C ion beams in a PMMA target at large angle
Proton and carbon ion beams are used in the clinical practice for external radiotherapy treatments achieving, for selected indications, promising and superior clinical results with respect to x-ray based radiotherapy. Other ions, like 4 H e have recently been considered as projectiles in particle therapy centres and might represent a good compromise between the linear energy transfer and the radiobiological effectiveness of 12 C ion and proton beams, allowing improved tumour control probability and minimising normal tissue complication probability. All the currently used p, 4 H e and 12 C ion beams allow achieving sharp dose gradients on the boundary of the target volume, however the accurate dose delivery is sensitive to the patient positioning and to anatomical variations with respect to photon therapy. This requires beam range and/or dose release measurement during patient irradiation and therefore the development of dedicated monitoring techniques. All the proposed methods make use of the secondary radiation created by the beam interaction with the patient and, in particular, in the case of 12 C ion beams are also able to exploit the significant charged radiation component. Measurements performed to characterise the charged secondary radiation created by 12 C and 4 H e particle therapy beams are reported. Charged secondary yields, energy spectra and emission profiles produced in a poly-methyl methacrylate (PMMA) target by 4 H e and 12 C beams of different therapeutic energies were measured at 60° and 90° with respect to the primary beam direction. The secondary yield of protons produced along the primary beam path in a PMMA target was obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The obtained measurements are in agreement with results reported in the literature and suggests the feasibility of range monitoring based on charged secondary particle detection: the implications for particle therapy monitoring applications are also discussed.
- 19 October 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (21) , 8483-8494
Addendum: Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u 12 C beam
In this paper we report the re-analysis of the data published in Piersanti et al (2014 Phys. Med. Biol . 59 1857) documenting the charged secondary particles production induced by the interaction of a 220 MeV/u 12 C ion beam impinging on a polymethyl methacrylate (PMMA) target, measured in 2012 at the GSI facility in Darmstadt (Germany). This re-analysis takes into account the inhomogeneous light response of the LYSO crystal in the experimental setup measured in a subsequent experiment (2014) performed in the Heidelberg Ion-Beam Therapy Center. A better description of the detector and re-calculation of the geometrical efficiencies have been implemented as well, based on an improved approach that accounts also for the energy dependence of the emission spectrum. The new analysis has little effect on the total secondary charged flux, but has an impact on the production yield and emission velocity distributions of the different particle species (protons, deuterons and tritons) at different angles with respect to the beam direction ( 60 ∘ and 90 ∘ ). All these observables indeed depend on the particle identification algorithms and hence on the LYSO detector energy response. The results of the data re-analysis presented here are intended to supersede and replace the results published in Piersanti et al (2014 Phys. Med. Biol . 59 1857).
- 19 October 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (21) , 8483-8494
Addendum: Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u 12 C beam
In this paper we report the re-analysis of the data published in Piersanti et al (2014 Phys. Med. Biol . 59 1857) documenting the charged secondary particles production induced by the interaction of a 220 MeV/u 12 C ion beam impinging on a polymethyl methacrylate (PMMA) target, measured in 2012 at the GSI facility in Darmstadt (Germany). This re-analysis takes into account the inhomogeneous light response of the LYSO crystal in the experimental setup measured in a subsequent experiment (2014) performed in the Heidelberg Ion-Beam Therapy Center. A better description of the detector and re-calculation of the geometrical efficiencies have been implemented as well, based on an improved approach that accounts also for the energy dependence of the emission spectrum. The new analysis has little effect on the total secondary charged flux, but has an impact on the production yield and emission velocity distributions of the different particle species (protons, deuterons and tritons) at different angles with respect to the beam direction ( 60 ∘ and 90 ∘ ). All these observables indeed depend on the particle identification algorithms and hence on the LYSO detector energy response. The results of the data re-analysis presented here are intended to supersede and replace the results published in Piersanti et al (2014 Phys. Med. Biol . 59 1857).
- 1 February 2017
- Published by Elsevier in Physica Medica
- Vol. 34, 18-27
Design of a new tracking device for on-line beam range monitor in carbon therapy
- 1 February 2017
- Published by Elsevier in Physica Medica
- Vol. 34, 18-27
Design of a new tracking device for on-line beam range monitor in carbon therapy