FKFutoshi Komine

Futoshi Komine

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Futoshi Komine has a total of 73 co-authors. Here are the top co-authors by number of shared publications:

  • Hideo Matsumura

    Department of Fixed Prosthodontics, Nihon University School of Dentistry

    30 shared publications
  • Ryosuke Fushiki

    Department of Fixed Prosthodontics, Nihon University School of Dentistry

    14 shared publications
  • Junichi Honda

    Department of Fixed Prosthodontics Nihon University School of Dentistry Chiyoda‐Ku Tokyo Japan

    10 shared publications
  • Kohei Taguchi

    Department of Fixed Prosthodontics, Nihon University School of Dentistry

    10 shared publications
  • Kei Kubochi

    Department of Fixed Prosthodontics, Nihon University School of Dentistry, Tokyo, Japan

    8 shared publications
  • Markus B. Blatz

    Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA

    8 shared publications

Latest Publications

  • Open Access

    Shear bond strength of resin luting material to zirconia using a pre-sintered coating approach

    by Satomi Arai, Kei Kubochi, Keisuke Hoshino, Futoshi Komine

    Purpose: The effect of a feldspathic porcelain coating applied before or after zirconia sintering on the shear bond strength between a resin luting agent and zirconia was evaluated.Methods: Pre-sintered and fully sintered zirconia specimens were coated with feldspathic porcelain and divided into three surface treatment groups: no treatment, airborne-particle abrasion, and hydrofluoric acid etching. The specimens were bonded using a dual-polymerizing resin luting agent and subjected to 0 or 5,000 thermocycles. The shear bond strength was measured. The fracture modes were analyzed microscopically. The surface morphology and composition were examined by scanning electron microscopy (SEM) and X-ray diffraction.Results: Before thermocycling, both airborne-particle abrasion and hydrofluoric acid etching significantly increased the bond strength compared with no treatment. After thermocycling, airborne-particle abrasion maintained the highest bond durability, while hydrofluoric acid etching showed a marked decrease. SEM revealed that airborne-particle abrasion produced a rough surface favorable for micromechanical retention, whereas hydrofluoric acid etching resulted in smoother morphology.Conclusion: Airborne-particle abrasion effectively enhanced and preserved the bond strength between the resin luting agent and feldspathic porcelain-coated zirconia, regardless of the coating sequence. Hydrofluoric acid etching was ineffective after thermocycling, likely due to surface precipitation that occurred during firing.

  • Open Access

    Fracture resistance of premolar screw-retained implant-supported hybrid abutment crowns with monolithic restorations after thermomechanical aging

    by Junichi Honda, Ryoki Takano, Takuma Saito, Tatsuro Kobayashi, Kei Kubochi, Markus Bernhard Blatz, Futoshi Komine

    Honda J, et al. J Adv Prosthodont. 2026 Feb;18(1):36-45. https://doi.org/10.4047/jap.2026.18.1.36


  • Open Access

    Ten‐Year Results of a Prospective Study on One‐Piece Zirconia Oral Implants for Single‐Tooth Reconstruction

    by Ralf‐Joachim Kohal, Agneta Lith, Futoshi Komine, Junichi Honda, Benedikt C. Spies, Felix Burkhardt, Kirstin Vach

    Objectives: The intention of this 10‐year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one‐piece zirconia implant system for single‐tooth replacement. Materials and Methods: A total of 65 patients received 66 single‐tooth implants restored with all‐ceramic crowns. Follow‐up assessments were conducted at the time of prosthetic delivery, after 1, 3, 5, and 10 years. Peri‐implant soft tissue parameters were evaluated. To assess peri‐implant bone loss, standardized radiographs were taken at implant placement, prosthetic delivery, at the 1‐, 3‐, 5‐, and 10‐year follow‐ups. Statistical analysis was conducted using linear mixed regression models and Wilcoxon Signed Rank tests to compare differences over time and between groups ( p < 0.05). Results: Over the course of 10 years, 16 implants were lost, yielding a cumulative survival rate of 73.3%. Fifteen patients were lost to follow‐up over the 10‐year period. The average marginal bone loss of the remaining implants was 1.09 mm. Probing depth, attachment level, and bleeding showed an increase over time, while plaque index slightly decreased. Conclusions: Given the high implant loss rate after 10 years and the high occurrence of advanced bone loss observed in this study, the implant was not recommended for routine clinical use.


  • Open Access

    One-piece zirconia oral implants supporting three-unit fixed dental prostheses: Ten-year results from a prospective case series

    by Ralf-Joachim Kohal, Futoshi Komine, Agneta Lith, Benedikt C. Spies, Felix Burkhardt, Kirstin Vach


  • Open Access

    Clinical performance of laminate veneers: A review of the literature

    by Futoshi Komine, Mika Furuchi, Junichi Honda, Kei Kubochi, Hiroki Takata

    Purpose: This narrative review aimed to survey the clinical outcomes of laminate veneers (LVs), including their survival and success rates.Study selection: An electronic search of MEDLINE/PubMed, Web of Science, Cochrane Library, and Google Scholar from 2000 to April 2023 was conducted using the keywords “laminate” OR “veneer” OR “porcelain” OR “feldspathic” OR “lithium disilicate” OR “composite resin” OR “zirconia” OR “survival” OR “success.” Case reports, case series, reviews, abstracts, in vitro studies, and observational studies were excluded. Five researchers independently evaluated the titles and abstracts of all identified studies.Results: A total of 55 studies were identified. None of the studies met the criteria for zirconia LVs. According to the studies in this review, LVs fabricated with feldspathic porcelain, leucite-reinforced glass ceramics (LRG), and lithium disilicate ceramics (LDS) exhibited satisfactory survival and success rates. Furthermore, hydrofluoric acid etching followed by silane priming of the surface of ceramic LVs is necessary for improved clinical outcomes. The extent of dentin exposure significantly decreases the success rate of ceramic LVs. An appropriate adhesive luting process is required to achieve the long-term success of ceramic LVs. Dentin exposure should be minimized or sealed during tooth preparation to achieve a reliable and durable bond between LVs and abutment teeth.Conclusions: Based on this narrative review of the literature, the use of silica-based ceramic feldspathic porcelain, LRG, and LDS is recommended for LVs.


  • Bond strength between a veneering composite resin and zirconia frameworks with attached mechanical retentive devices

    by Keisuke Matsushima, Kei Kubochi, Futoshi Komine, Fumiaki Kimura, Tatsuro Kobayashi, Hideo Matsumura

    The effects of mechanical retentive devices and various surface treatments on the shear bond strength between a veneering composite resin and zirconia was investigated. Zirconia disks were classified into three surface-treatment groups: airborne-particle abrasion, overglazing, and overglazing with white alumina particles of three different grain sizes (50, 70, and 105 μm) attached onto zirconia disks (ZR-50, ZR-70, and ZR-105, respectively). They were further divided into four groups (n=44): unprimed, Clearfil Porcelain Bond Activator (CA), Clearfil Photo Bond (CB), and CA+CB. An indirect composite resin was bonded to zirconia specimens. Shear bond strengths were measured. For the ZR-70 and ZR-105 groups, the CB and CA+CB specimens exhibited higher bond strengths than the other two specimens after thermocycling. The ZR-70 and ZR-105 groups achieved micromechanical interlocking, and priming with a phosphate monomer (MDP) yielded stable bond strengths between the composite resin and zirconia with alumina particles attached as retentive devices.


  • Open Access

    Effect of firing procedures and layering thickness of porcelain on internal adaptation of zirconia cantilever resin-bonded fixed dental prostheses

    by Jin Kitani, Futoshi Komine, Kosuke Kusaba, Daishi Nakase, Keigo Ito, Hideo Matsumura

    Purpose: This study evaluated the influence of firing procedures and layering thickness of porcelain on internal adaptation of maxillary anterior cantilever zirconia resin-bonded fixed dental prostheses (RBFDPs). Methods: The maxillary right central incisor on a model was prepared for a single-retainer zirconia RBFDP. A total of 36 frameworks of cantilever zirconia RBFDPs were classified into three groups (CB0.5, CB1.0, and CB2.0 groups) based on the thickness of the cut-back on the facial surface (0.5 mm, 1.0 mm, and 2.0 mm, respectively). Feldspathic porcelain was layered onto the facial surface of the zirconia RBFDP frameworks. Internal space widths between the abutment tooth and the framework were measured before and after porcelain firing by a replica technique. The internal space values before and after porcelain firings were compared using the paired t-test within the same group (α = 0.05). Differences in internal space values (distortion) between before and after porcelain firing were compared using one-way analysis of varianc e and Tukey multiple comparison tests. Results: For all framework designs, internal space values after porcelain firing were significantly higher than those before firing. Among all groups, the CB0.5 group showed the lowest internal distortion values for the whole measured area. The CB2.0 group showed higher distortion values than the CB1.0 group. Conclusions: Porcelain firing procedures negatively impacted the internal space in cantilever zirconia RBFDPs. In addition, the increased volume of layering porcelain had a negative effect on the internal distortion of ma xillary anterior cantilever zirconia RBFDPs.


  • Shear bond strength between gingival composite resin and glazed gingival porcelain for implant‐supported prostheses

    by Futoshi Komine, Kei Kubochi, Fumiaki Kimura, Kosuke Kusaba, Ryoki Takano, Hideo Matsumura

    This study determined the shear bond strength (SBS) between an indirect gingival composite resin and glazed gingival porcelain after various surface treatments. A total of 176 porcelain disks with natural glazing were used and assigned to one of four groups: no surface treatment, airborne‐particle abrasion, hydrofluoric acid etching, or a combination of airborne‐particle abrasion followed by hydrofluoric acid etching. Each group was divided into two subgroups: one subgroup was unprimed, and the other was silanized. An indirect composite resin was then bonded to the porcelain disks. Half of the specimens in each group (n = 11) were exposed to 5000 thermocycles. SBSs were measured, and data were analyzed with the Kruskal–Wallis and Steel–Dwass tests. Among silanized specimens, those treated with the combination of airborne‐particle abrasion and hydrofluoric acid etching exhibited the highest bond strengths both before and after thermocycling. However, the SBS values of the silanized and unprimed hydrofluoric acid etched specimens did not differ significantly. Airborne‐particle abrasion followed by hydrofluoric acid etching with silane application yielded stronger, more durable bonds between the indirect gingival composite resin and glazed gingival porcelain.


  • Open Access

    Effect of luting agent type on fracture loads of implant-supported ceramic premolar prostheses

    by Yuta Moriya, Futoshi Komine, Junichi Honda, Kosuke Kusaba, Jin Kitani, Hideo Matsumura

    To investigate the effect of luting agent type on fracture loads of implant-supported ceramic prostheses in premolar region. Ninety-nine implant-abutment complexes were divided into three different implant-supported prostheses: monolithic yttria-partially stabilized zirconia (Y-PSZ) restorations (MPZ specimens), porcelain layered on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations (PLZ specimens), and monolithic lithium disilicate ceramic restorations (MLD specimens). Implant-supported prostheses were luted with adhesive resin luting agent (RLA), glass ionomer cement (GIC), or zinc phosphate cement (ZPC). For MPZ and MLD specimens, fracture loads were significantly higher for RLA group than for GIC and ZPC groups. For PLZ specimens, fracture loads did not significantly differ in relation to luting agent. Fracture loads were significantly higher for MPZ specimens than for other test specimens, regardless of luting agent. Use of an adhesive resin luting agent is recommended for placement of premolar implant-supported monolithic Y-PSZ and lithium disilicate ceramic prostheses.