SMSarah Lynn Manske

Sarah Lynn Manske

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sarah Lynn Manske has a total of 215 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Semi-automated three-dimensional techniques for measuring dorsal scaphoid translation

    by Justen Saini, Brodie Ritchie, Charley Hasselaar, Neil J. White, Koren E. Roach, Sarah L. Manske

  • Open Access

    Relationship between brain metabolites and chronic pain mechanisms in knee osteoarthritis pre- and post-total knee replacement

    by Samantha A Leech, Marilena M DeMayo, Tiffany K Bell, Mataea AL Armstrong, Claudia M Campbell, Chel Hee Lee, Eldridge Batuyong, Geoff Schneider, Neil J White, Richard Ea Walker, et al.

  • Open Access

    Improved segmentation accuracy in high-resolution peripheral quantitative computed tomography scans of carpal bones using adaptive local thresholding

    by Michael T Kuczynski, Simone Poncioni, Sarah Elmahdy, Erica Baldesarra, Philippe Zysset, Sarah L Manske, Danielle E Whittier

    The choice of segmentation method for HR-pQCT scans influences accuracy of bone microarchitecture measurements. Smaller or under-mineralized bone can present challenges in accurate extraction of bone structure using global thresholding methods, as local variations in intensity are not considered and finer structural details are not detected. This is especially important in small hand bones, where bone structure is finer, or younger populations, where bone tissue may be under mineralized. This study compared accuracy of global thresholding methods using Gaussian and Laplace–Hamming filters, and an adaptive local thresholding (AT) method in HR-pQCT scans of carpal bones. Eight ex vivo human cadaveric forearms (n = 64 carpal bones) were analyzed. Three specimens (n = 24 carpal bones, 2 female, mean age: 82.7 ± 4.6 yr) were used for AT parameter optimization, and 5 specimens (n = 40 carpal bones, 3 female, mean age: 82.0 ± 6.4 yr) were used to compare trabecular microarchitecture accuracy and spatial agreement relative to micro-CT (μCT, 20 μm isotropic resolution). Micro-CT images were segmented using a Gaussian filter and Otsu’s method, and HR-pQCT images were segmented using Gaussian filtering and global thresholding, Laplace–Hamming filtering and global thresholding, and the AT method. Trabecular thickness (Tb.Th), separation (Tb.Sp), and bone volume fraction (Tb.BV/TV) accuracy were evaluated, and spatial agreement was assessed using Dice similarity coefficients (DSC), 95th percentile Hausdorff distances (HD95), and average symmetric surface distances (ASSD). The AT method yielded the smallest absolute and relative errors, and lowest bias across all trabecular parameters. Compared to the Gaussian and fixed threshold method, AT reduced mean absolute error by 36% for Tb.Th, 14% for Tb.Sp, and 15% for Tb.BV/TV, and achieved the highest spatial agreement with μCT (DSC = 0.84, HD95 = 0.061 mm, and ASSD = 0.018 mm). These findings extend prior HR-pQCT segmentation validation studies to carpal bones and demonstrate that AT outperforms the standard and Laplace–Hamming methods.

  • Open Access

    Effects of contrast on opportunistic computed tomography vertebral bone mineral density analysis using internal calibration

    by Bryn E Matheson, Kirsten N Bott, Andrew G Kiraly, Richard E A Walker, Steven K Boyd, Sarah L Manske

    Opportunistic computed tomography (CT), which repurposes clinical CT scans, has the potential to aid in osteoporosis screening and diagnosis. To convert CT scans to bone-equivalent densities without a calibration phantom, internal (or phantomless) calibration methods have been developed, using referent tissues of known density within the body. A key limitation is that intravenous iodinated contrast enhancement, which is routinely used in clinical settings, impacts quantitative measurements derived from these phantomless calibration techniques. Therefore, this cross-sectional study examined the influence of contrast enhancement on internal reference tissues and vBMD measures derived using phantomless internal calibration. Hematuria protocol CT scans (N=194) were retrospectively analyzed. This protocol included unenhanced and two enhanced CT scans from the nephrographic (~90-second delay) and urographic (~10-minute delay) phases. The vertebrae were automatically identified and segmented with labels for the vertebral body and trabecular bone compartment in the third lumbar vertebra. Internal density calibration was performed using our previously established method with internal referent tissues (air, adipose, skeletal muscle, and cortical bone) to estimate the effective energy of each scan. A linear correction, derived based on training data from the nephrographic phase, was applied to test datasets from both the nephrographic and urographic phases. The nephrographic phase increased the vertebral body vBMD by 9.90 ± 4.28 mg/cm3 (5.52%, p < 0.0001) and the urographic phase by 2.33 ± 3.26 mg/cm3 (1.33%, p < 0.0001) compared to unenhanced scans. Applying the linear equation derived from the nephrographic training data reduced vBMD differences in the nephrographic test data but increased the variation in the urographic phase vBMD, demonstrating the need for phase-specific correction. This study demonstrates that vBMD measurements from contrast-enhanced CT are subject to significant error unless the interval between contrast administration and scan acquisition can be accounted for. Screening for osteoporosis helps prevent fragility fractures, and opportunistic computed tomography can improve screening by extracting bone density information from scans performed for other clinical purposes. This method uses an individual’s tissues captured in the scan to estimate bone density without the need for a specialized calibration tool. A major challenge, however, is the impact of intravenous contrast enhancement on tissue densities and subsequent measurements. This study found that vertebral bone density estimates varied by contrast phase. These findings demonstrate that bone density measurements are susceptible to significant errors following contrast administration.

  • Open Access

    Semi-Automated Three-Dimensional Techniques for Measuring Dorsal Scaphoid Translation

    by Justen Saini, Brodie Ritchie, Charley Hasselaar, Neil Jeffrey White, Koren E. Roach, Sarah L. Manske

    Carpal stability under load is dependent on healthy carpal bone alignment, yet current imaging methods cannot evaluate three-dimensional carpal bone position during functional loading. Scapholunate interosseous ligament (SLIL) injuries are an example of altered carpal stability that leads to abnormal load transmission that cannot be detected in unloaded imaging. Therefore, the purpose of this study was to characterize carpal bone position changes under load and to develop semi-automated three-dimensional carpal alignment measurement techniques, including two approaches to measure three-dimensional dorsal scaphoid translation. Ten healthy controls and ten individuals with SLIL injuries underwent weight-bearing computed tomography scans in three positions: non-weightbearing, weightbearing with pushup bars, and weightbearing extension. SLIL-injured wrists demonstrated significantly greater dorsal scaphoid translation (p = 0.035, 2.18±2.25 millimeters) than controls (0.30±0.98 millimeters) in the non-weightbearing position. Loading the wrist produced opposing scaphoid translation patterns between groups. From the non-weightbearing to weightbearing pushup bar position, SLIL-injured wrists demonstrated a palmar scaphoid shift (-1.10±0.96 millimeters) whereas controls shifted dorsally (0.10±1.24 millimeters); this significantly differed between groups (p = 0.045). From the non-weightbearing to weightbearing extension position, SLIL-injured wrists demonstrated a palmar scaphoid shift (-0.94±1.68 millimeters) whereas controls shifted dorsally (0.51±1.73 millimeters); this significantly differed between groups (p = 0.024). Multiplanar angular measurements also revealed pathological lunate extension and ulnar deviation with SLIL injury. These findings indicate that load-dependent assessments of the wrist can be captured with semi-automated measures, demonstrating altered biomechanics and load transmission that cannot be detected in unloaded imaging.

  • Open Access

    Evaluation of the use of segmentation-based and deconvolution-based three-dimensional joint space width analysis of the hand and wrist

    by Jilmen Quintiens, Tadiwa H Waungana, Michael T Kuczynski, Sarah L Manske, G Harry van Lenthe

    Three-dimensional morphometric analyses of joint space from computed tomography (CT) scans can provide a quantitative and unbiased evaluation of radiographic damage from arthritis. This potentially offers greater sensitivity for disease assessment and monitoring than traditional ordinal scoring systems. Previously established methods for three-dimensional joint space analysis from CT scans can be categorized into segmentation-based and grayscale deconvolution-based methods. However, segmentation-based methods have not been employed for joints other than metacarpophalangeal joints, nor have they been compared to deconvolution-based methods. This study compared the joint space width (JSW) distribution from various hand and wrist joints in photon-counting CT images, using both measurement approaches. From these distributions, the mean (JSW.Mean), standard deviation (JSW.SD), maximum (JSW.Max), minimum (JSW.Min), 95th percentile (JSW.95%), and 5th percentile (JSW.5%) values were calculated. For each morphometry parameter, agreement between the two methods was assessed by calculating the coefficient of determination (R2), and the mean and standard deviation of the individual biases. General estimating equations were used to assess the relationship between morphometry and an equivalent/modified Sharp/van der Heijde (SvdH) ordinal radiographic score. In general, agreement between the two methods was low: R2 ranged between 0.42 and 0.87; biases up to 0.18 mm |$\pm$| 0.33 mm). For both methods, an increased degree of joint space narrowing as assessed with SvdH was associated with reduced JSW.Min and increased JSW.SD; for the deconvolution method, it was also associated with decreased JSW.Mean and increased JSW.Max. Interactions between the methods showed a weaker association to SvdH score for JSW.Min and a stronger association for JSW.SD when measured with the deconvolution method, compared to the segmentation method. We conclude that both methods lead to fundamentally different measurement outcomes, and that the deconvolution method might be more sensitive to radiographic damage.

  • Open Access

    Open and reproducible research in musculoskeletal imaging: Why it matters and how to implement it with the guidelines of the ORMIR community

    by Serena Bonaretti, Mojtaba Barzegari, Melissa Bevers, Steven Boyd, Andrew J Burghardt, Donnie Cameron, Francesco Chiumento, Gianluigi Crimi, Gerard Degenhart, Pholpat Durongbhan, et al.

    The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community is a scientific community dedicated to promoting openness and reproducibility in musculoskeletal imaging, image processing, and computational modelling. In this perspective paper, we outline the motivations for conducting transparent research and provide practical guidelines to implement it. We start with defining open and reproducible research and describing the benefits and challenges of working transparently. Next, we redefine the outputs of a computational research study as—ideally—a combination of data, code, and a publication, recommend a folder and file structure that reflects these three study outcomes, and describe how to maintain and update such a structure during the study and at study publication. Finally, we emphasize that working in an open and reproducible manner is a learning process and the best way to acquire the necessary competencies is simply to start. Lay summary: The ORMIR community promotes openness and reproducibility in musculoskeletal imaging research. In this perspective paper, we explain why transparency matters and recommend how to conduct a computational study in an open and reproducible manner focusing on its three outputs: data, code, and publication. Finally, we highlight that the best way to learn these practices is simply to start.


  • Open Access

    Repeatability of objective bone and joint measures in the knee using weight-bearing computed tomography: three-dimensional quantification of bone mineral density, joint space width, and subchondral bone plate thickness

    by Tadiwa H Waungana, Ria Mangat, Chloe Chen, Ainsley C J Smith, Yousif Al-Khoury, Michael T Kuczynski, Tom Turmezei, Donald D Anderson, William Brent Edwards, Sarah L Manske

    Bone alterations and degenerative joint structural changes are frequently observed in knee osteoarthritis (OA). Objective measures of subchondral bone plate thickness (SBP.Th), apparent BMD, and joint space width (JSW) have begun to be used to better assess and understand disease progression. Weight-bearing CT (WBCT) allows 3D assessment of multiple bone and joint parameters; however, there is a paucity of literature investigating factors that might affect our ability to track changes over time. The purpose of this study was to investigate the repeatability of BMD, JSW, and SBP.Th measures obtained from WBCT images. Same-day, scan–rescan, knee WBCT images were acquired from 37 healthy adults (20 female, mean age: 24.6 yr). We quantified trabecular bone BMD at the proximal tibia and implemented joint space and cortical bone mapping to measure tibiofemoral JSW and SBP.Th, respectively. Test–retest repeatability was evaluated using coefficients of variation (CVRMS%) and least significant change (LSC). Mean trabecular BMD exhibited CVRMS% ranging from 1.87% to 2.85% and LSCs between 13.53 and 17.39 mgHA/cm3. For JSW, CVRMS% and LSC were less than 1% and 0.2 mm, respectively. SBP.Th measures had higher CVRMS% (9.75%-11.29%) but similar LSC values (0.09-0.26 mm) in comparison to JSW values. The high repeatability of subchondral bone and joint parameters underscore the potential of WBCT for quantifying and monitoring bone and joint changes in knee OA progression and management. However, standardization of acquisition and analysis methods will likely be required to ensure reliable evaluation over multiple time points.


  • Open Access

    Region-specific variation in trapeziometacarpal joint bone microarchitecture in females with osteoarthritis assessed using HR-pQCT

    by Michael T. Kuczynski, Charley Hasselaar, Gurpreet Dhaliwal, Christina Hiscox, Neil J. White, Danielle E. Whittier, Sarah L. Manske