Premanand Chandran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Premanand Chandran has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Ganesh V Raman
Department of Glaucoma, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India
13 shared publicationsGanesh V. Raman
Glaucoma services, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India
6 shared publicationsMrunali Dhavalikar
Department of Glaucoma, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India
4 shared publicationsNabeed Aboobacker
Department of Glaucoma, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India
4 shared publicationsVinoth Arunaachalam
Coimbatore, Tamil Nadu, India
4 shared publicationsAbhipsa Sahu
Department of Glaucoma, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India
3 shared publications
Latest Publications
- 19 October 2026
- Published by Elsevier in Ophthalmology
Bee Stinger: A Rare Intraocular Foreign Body
- Open Access
Optimal Dimension of Peripheral Iridotomy for Anatomical Efficacy in Primary-Angle-Closure Disease
The aim of this study is to determine the optimal functional size of laser peripheral iridotomy (LPI) for anterior chamber parameter improvement in primary angle-closure disease (PACD). This study evaluated 109 eyes from 62 consecutive phakic patients. Baseline and one-week post-LPI anterior segment OCT were utilized to measure anterior chamber volume (ACV), anterior chamber angle (ACA), and iridotomy dimensions. Data was analyzed using linear mixed-effects models (LMMs), generalized additive models (GAMs), and receiver operating characteristic (ROC) curves. Post-LPI, significant increases occurred in ACA 500 (+7.54°), ACV (+11.09 mm3), and gonioscopic grade. LMMs confirmed a positive association between iridotomy size and anatomical expansion. GAMs demonstrated a saturation effect for ACV improvement, plateauing at 0.1 mm2 (narrow area) and 0.25–0.30 mm2 (superficial area), while the ACA relationship remained predominantly linear. ROC analysis identified preliminary superficial area cutoffs of 0.14 mm2 and 0.12 mm2 as discriminators of above-median volumetric and angular response, respectively. These findings suggest that LPI size is an independent determinant of anatomical response, beyond simple patency. As a preliminary, hypothesis-generating target, a superficial iridotomy area of approximately 0.12–0.14 mm2 was associated with above-median volumetric and angular response in this cohort. Prospective validation is required before these thresholds can be incorporated into clinical practice.
Open AccessOptimal Dimension of Peripheral Iridotomy for Anatomical Efficacy in Primary-Angle-Closure Disease
The aim of this study is to determine the optimal functional size of laser peripheral iridotomy (LPI) for anterior chamber parameter improvement in primary angle-closure disease (PACD). This study evaluated 109 eyes from 62 consecutive phakic patients. Baseline and one-week post-LPI anterior segment OCT were utilized to measure anterior chamber volume (ACV), anterior chamber angle (ACA), and iridotomy dimensions. Data was analyzed using linear mixed-effects models (LMMs), generalized additive models (GAMs), and receiver operating characteristic (ROC) curves. Post-LPI, significant increases occurred in ACA 500 (+7.54°), ACV (+11.09 mm3), and gonioscopic grade. LMMs confirmed a positive association between iridotomy size and anatomical expansion. GAMs demonstrated a saturation effect for ACV improvement, plateauing at 0.1 mm2 (narrow area) and 0.25–0.30 mm2 (superficial area), while the ACA relationship remained predominantly linear. ROC analysis identified preliminary superficial area cutoffs of 0.14 mm2 and 0.12 mm2 as discriminators of above-median volumetric and angular response, respectively. These findings suggest that LPI size is an independent determinant of anatomical response, beyond simple patency. As a preliminary, hypothesis-generating target, a superficial iridotomy area of approximately 0.12–0.14 mm2 was associated with above-median volumetric and angular response in this cohort. Prospective validation is required before these thresholds can be incorporated into clinical practice.
- Open Access
- 7 January 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (3) , 420-424
Efficacy and safety of micropulse transcleral cyclophotocoagulation using the original and revised pars plana probe
Purpose: To compare the efficacy and safety of micropulse transcleral cyclophotocoagulation (MP-TSCPC) using the original and revised pars plana probe in patients with glaucoma. Methods: Retrospective review of records who underwent MP-TSCPC between August 2020 and July 2023. Patients aged >12 years and with a minimum follow-up of 1 year were included. Success was defined as intraocular pressure (IOP) ≥ 6 and ≤21 mm Hg with the same or fewer antiglaucoma medications and a minimum of 20% IOP reduction. Results: A total of 21 eyes treated with the original probe and 22 eyes treated with the revised probe were included. Baseline characteristics were comparable between the two groups. Mean IOP reduced from 30.3 ± 9.9 mm Hg to 21.8 ± 8.2 and 20.2 ± 7.5 ( P < 0.001) mm Hg at 6 months and 1 year, respectively, with the original probe and from 26.1 ± 8.4 mm Hg to 19.1 ± 7.4 and 18.8 ± 5.8 ( P = 0.009) mm Hg at 6 months and 1 year, respectively, with the revised probe. The difference between the probes was not statistically significant at all-time points. The mean number of antiglaucoma medications reduced from 3.9 ± 0.7 to 3.3 ± 1 at 1 year ( P = 0.006) with the original probe and from 3.9 ± 1.1 to 3.4 ± 1.4 at 1 year ( P = 0.045) with the revised probe. The probability of qualified success at 1 year was 33.3% for the original probe and 40.9% for the revised probe ( P = 0.755). Conclusion: MP-TSCPC is a safe and effective treatment for reducing IOP with both the original and revised probes, but the efficacy is not long-lasting.
- 7 January 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (3) , 420-424
Open AccessEfficacy and safety of micropulse transcleral cyclophotocoagulation using the original and revised pars plana probe
Purpose: To compare the efficacy and safety of micropulse transcleral cyclophotocoagulation (MP-TSCPC) using the original and revised pars plana probe in patients with glaucoma. Methods: Retrospective review of records who underwent MP-TSCPC between August 2020 and July 2023. Patients aged >12 years and with a minimum follow-up of 1 year were included. Success was defined as intraocular pressure (IOP) ≥ 6 and ≤21 mm Hg with the same or fewer antiglaucoma medications and a minimum of 20% IOP reduction. Results: A total of 21 eyes treated with the original probe and 22 eyes treated with the revised probe were included. Baseline characteristics were comparable between the two groups. Mean IOP reduced from 30.3 ± 9.9 mm Hg to 21.8 ± 8.2 and 20.2 ± 7.5 ( P < 0.001) mm Hg at 6 months and 1 year, respectively, with the original probe and from 26.1 ± 8.4 mm Hg to 19.1 ± 7.4 and 18.8 ± 5.8 ( P = 0.009) mm Hg at 6 months and 1 year, respectively, with the revised probe. The difference between the probes was not statistically significant at all-time points. The mean number of antiglaucoma medications reduced from 3.9 ± 0.7 to 3.3 ± 1 at 1 year ( P = 0.006) with the original probe and from 3.9 ± 1.1 to 3.4 ± 1.4 at 1 year ( P = 0.045) with the revised probe. The probability of qualified success at 1 year was 33.3% for the original probe and 40.9% for the revised probe ( P = 0.755). Conclusion: MP-TSCPC is a safe and effective treatment for reducing IOP with both the original and revised probes, but the efficacy is not long-lasting.
- Open Access
- 29 October 2025
- Published by Elsevier in AJO International
- Vol. 2 (4)
Ability of the optical coherence tomography parameters to identify retinal nerve fibre layer defect in Indian eyes with mild glaucoma
- 29 October 2025
- Published by Elsevier in AJO International
- Vol. 2 (4)
Open AccessAbility of the optical coherence tomography parameters to identify retinal nerve fibre layer defect in Indian eyes with mild glaucoma
- Open Access
- 28 April 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (2) , 284-285
Bilateral congenital ectropion uveae without glaucoma: A case report and review of literature
A 12-year-old boy presented with high intraocular pressure (IOP) in both eyes (BE). An anterior segment examination revealed ectropion uveae with iris stromal hypoplasia in BE. Gonioscopy showed anterior insertion of the iris, and a posterior segment examination showed a healthy optic nerve head with an attached retina in BE. A physical examination did not reveal any systemic association. He was diagnosed with congenital ectropion uveae with secondary ocular hypertension. IOP was controlled with antiglaucoma medication, and he was advised to undergo regular lifelong follow-up.
- 28 April 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (2) , 284-285
Open AccessBilateral congenital ectropion uveae without glaucoma: A case report and review of literature
A 12-year-old boy presented with high intraocular pressure (IOP) in both eyes (BE). An anterior segment examination revealed ectropion uveae with iris stromal hypoplasia in BE. Gonioscopy showed anterior insertion of the iris, and a posterior segment examination showed a healthy optic nerve head with an attached retina in BE. A physical examination did not reveal any systemic association. He was diagnosed with congenital ectropion uveae with secondary ocular hypertension. IOP was controlled with antiglaucoma medication, and he was advised to undergo regular lifelong follow-up.
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (4) , 1009
Solitary radial ciliary vessel in the anterior chamber angle
- 1 October 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (4) , 1009
Open AccessSolitary radial ciliary vessel in the anterior chamber angle
- Open Access
- 30 July 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (3) , 770
Zentmayer line in pigment dispersion syndrome
- 30 July 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (3) , 770
Open AccessZentmayer line in pigment dispersion syndrome
- 13 May 2024
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 7 (6) , e11
Candy-Stripe Hyphema after Laser Peripheral Iridotomy
- 13 May 2024
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 7 (6) , e11
Candy-Stripe Hyphema after Laser Peripheral Iridotomy
- Open Access
- 16 January 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (1) , 313-314
Silicone oil–filled anterior chamber with secondary angle-closure glaucoma
- 16 January 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (1) , 313-314
Open AccessSilicone oil–filled anterior chamber with secondary angle-closure glaucoma
- Open Access
- 1 August 2023
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (8) , 2962-2966
Comparison between ocular biometry parameters in patients with unilateral congenital glaucoma
Purpose: To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age. Methods: Retrospective longitudinal study. Patients who had a follow-up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details. Results: Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years. Conclusion: Axial length and corneal diameter were higher in GE than NE at all-time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.
- 1 August 2023
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (8) , 2962-2966
Open AccessComparison between ocular biometry parameters in patients with unilateral congenital glaucoma
Purpose: To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age. Methods: Retrospective longitudinal study. Patients who had a follow-up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details. Results: Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years. Conclusion: Axial length and corneal diameter were higher in GE than NE at all-time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.