Xuejin Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xuejin Wen has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Wu Lu
Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
7 shared publicationsSamit Gupta
Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210, USA
4 shared publicationsStephen C. Lee
Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210, USA
4 shared publications- Wu Lu
Department of Electrical and Computer Engineering, The Ohio State University 1 , Columbus, Ohio 43210
4 shared publications Theodore R. Nicholson
The Ohio State University 2 The Department of Biomedical Engineering Columbus, Ohio 43210, USA
3 shared publications- Bharat Bhushan
The Ohio State University, San Jose, USA
2 shared publications
Latest Publications
- Open Access
- 12 April 2013
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 58 (21) , 2601-2605
AlGaN/GaN heterostructure field transistor for label-free detection of DNA hybridization
- 12 April 2013
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 58 (21) , 2601-2605
Open AccessAlGaN/GaN heterostructure field transistor for label-free detection of DNA hybridization
- 28 May 2012
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 370 (1967) , 2474-2488
ImmunoFET feasibility in physiological salt environments
Field-effect transistors (FETs) are solid-state electrical devices featuring current sources, current drains and semiconductor channels through which charge carriers migrate. FETs can be inexpensive, detect analyte without label, exhibit exponential responses to surface potential changes mediated by analyte binding, require limited sample preparation and operate in real time. ImmunoFETs for protein sensing deploy bioaffinity elements on their channels (antibodies), analyte binding to which modulates immunoFET electrical properties. Historically, immunoFETs were assessed infeasible owing to ion shielding in physiological environments. We demonstrate reliable immunoFET sensing of chemokines by relatively ion-impermeable III-nitride immunoHFETs (heterojunction FETs) in physiological buffers. Data show that the specificity of detection follows the specificity of the antibodies used as receptors, allowing us to discriminate between individual highly related protein species (human and murine CXCL9) as well as mixed samples of analytes (native and biotinylated CXCL9). These capabilities demonstrate that immunoHFETs can be feasible, contrary to classical FET-sensing assessment. FET protein sensors may lead to point-of-care diagnostics that are faster and cheaper than immunoassay in clinical, biotechnological and environmental applications.
- 28 May 2012
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 370 (1967) , 2474-2488
ImmunoFET feasibility in physiological salt environments
Field-effect transistors (FETs) are solid-state electrical devices featuring current sources, current drains and semiconductor channels through which charge carriers migrate. FETs can be inexpensive, detect analyte without label, exhibit exponential responses to surface potential changes mediated by analyte binding, require limited sample preparation and operate in real time. ImmunoFETs for protein sensing deploy bioaffinity elements on their channels (antibodies), analyte binding to which modulates immunoFET electrical properties. Historically, immunoFETs were assessed infeasible owing to ion shielding in physiological environments. We demonstrate reliable immunoFET sensing of chemokines by relatively ion-impermeable III-nitride immunoHFETs (heterojunction FETs) in physiological buffers. Data show that the specificity of detection follows the specificity of the antibodies used as receptors, allowing us to discriminate between individual highly related protein species (human and murine CXCL9) as well as mixed samples of analytes (native and biotinylated CXCL9). These capabilities demonstrate that immunoHFETs can be feasible, contrary to classical FET-sensing assessment. FET protein sensors may lead to point-of-care diagnostics that are faster and cheaper than immunoassay in clinical, biotechnological and environmental applications.
- 22 March 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 41 (5) , 830-836
Surface Functionalization of Hydrogen-Terminated Si for Biosensing Applications
- 22 March 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 41 (5) , 830-836
Surface Functionalization of Hydrogen-Terminated Si for Biosensing Applications
- 25 July 2011
- Published by AIP Publishing in Applied Physics Letters
- Vol. 99 (4) , 043701
High sensitivity AlGaN/GaN field effect transistor protein sensors operated in the subthreshold regime by a control gate electrode
We demonstrate high sensitivity AlGaN/GaN field effect transistor biosensors with a control gate electrode for streptavidin detection. The device active area is functionalized with 3-Aminopropyltriethoxysilane and -hydroxysulfosuccinimide-biotin for streptavidin binding. Without any electrochemical side effects, a gate voltage is applied through a Pt control electrode to the solution so that the device operates sensitively in the subthreshold regime. Due to the logarithmic relationship between the channel current and gate voltage in the subthreshold regime, at a concentration of 4.73 pM streptavidin, the device exhibits 9.97% current change in the subthreshold regime compared with the current in phosphate buffered saline solution. In the linear regime, the current change is 0.49% at the same streptavidin concentration.- 25 July 2011
- Published by AIP Publishing in Applied Physics Letters
- Vol. 99 (4) , 043701
High sensitivity AlGaN/GaN field effect transistor protein sensors operated in the subthreshold regime by a control gate electrode
We demonstrate high sensitivity AlGaN/GaN field effect transistor biosensors with a control gate electrode for streptavidin detection. The device active area is functionalized with 3-Aminopropyltriethoxysilane and -hydroxysulfosuccinimide-biotin for streptavidin binding. Without any electrochemical side effects, a gate voltage is applied through a Pt control electrode to the solution so that the device operates sensitively in the subthreshold regime. Due to the logarithmic relationship between the channel current and gate voltage in the subthreshold regime, at a concentration of 4.73 pM streptavidin, the device exhibits 9.97% current change in the subthreshold regime compared with the current in phosphate buffered saline solution. In the linear regime, the current change is 0.49% at the same streptavidin concentration.- 1 June 2011
- Published by Wiley in physica status solidi (c)
- Vol. 8 (7-8) , 2489-2491
AlGaN/GaN HFET biosensors working at subthreshold regime for sensitivity enhancement
- 1 June 2011
- Published by Wiley in physica status solidi (c)
- Vol. 8 (7-8) , 2489-2491
AlGaN/GaN HFET biosensors working at subthreshold regime for sensitivity enhancement
- 22 December 2010
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 44 (3)
Interfacial design and structure of protein/polymer films on oxidized AlGaN surfaces
Protein detection using biologically or immunologically modified field-effect transistors (bio/immunoFETs) depends on the nanoscale structure of the polymer/protein film at sensor interfaces (Bhushan 2010 Springer Handbook of Nanotechnology 3rd edn (Heidelberg: Springer); Gupta et al 2010 The effect of interface modification on bioFET sensitivity, submitted). AlGaN-based HFETs (heterojunction FETs) are attractive platforms for many protein sensing applications due to their electrical stability in high osmolarity aqueous environments and favourable current drive capabilities. However, interfacial polymer/protein films on AlGaN, though critical to HFET protein sensor function, have not yet been fully characterized. These interfacial films are typically comprised of protein–polymer films, in which analyte-specific receptors are tethered to the sensing surface with a heterobifunctional linker molecule (often a silane molecule). Here we provide insight into the structure and tribology of silane interfaces composed of one of two different silane monomers deposited on oxidized AlGaN, and other metal oxide surfaces. We demonstrate distinct morphologies and wear properties for the interfacial films, attributable to the specific chemistries of the silane monomers used in the films. For each specific silane monomer, film morphologies and wear are broadly consistent on multiple oxide surfaces. Differences in interfacial film morphology also drive improvements in sensitivity of the underlying HFET (coincident with, though not necessarily caused by, differences in interfacial film thickness). We present a testable model of the hypothetical differential interfacial depth distribution of protein analytes on FET sensor interfaces with distinct morphologies. Empirical validation of this model may rationalize the actual behaviour of planar immunoFETs, which has been shown to be contrary to expectations of bio/immunoFET behaviour prevalent in the literature for the last 20 years. Improved interfacial properties of bio/immunoHFETs have improved bio/immunoHFET performance: better understanding of interfaces may lead to mechanistic understanding of FET sensor properties and to clinical translation of the immunoFET platform.
- 22 December 2010
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 44 (3)
Interfacial design and structure of protein/polymer films on oxidized AlGaN surfaces
Protein detection using biologically or immunologically modified field-effect transistors (bio/immunoFETs) depends on the nanoscale structure of the polymer/protein film at sensor interfaces (Bhushan 2010 Springer Handbook of Nanotechnology 3rd edn (Heidelberg: Springer); Gupta et al 2010 The effect of interface modification on bioFET sensitivity, submitted). AlGaN-based HFETs (heterojunction FETs) are attractive platforms for many protein sensing applications due to their electrical stability in high osmolarity aqueous environments and favourable current drive capabilities. However, interfacial polymer/protein films on AlGaN, though critical to HFET protein sensor function, have not yet been fully characterized. These interfacial films are typically comprised of protein–polymer films, in which analyte-specific receptors are tethered to the sensing surface with a heterobifunctional linker molecule (often a silane molecule). Here we provide insight into the structure and tribology of silane interfaces composed of one of two different silane monomers deposited on oxidized AlGaN, and other metal oxide surfaces. We demonstrate distinct morphologies and wear properties for the interfacial films, attributable to the specific chemistries of the silane monomers used in the films. For each specific silane monomer, film morphologies and wear are broadly consistent on multiple oxide surfaces. Differences in interfacial film morphology also drive improvements in sensitivity of the underlying HFET (coincident with, though not necessarily caused by, differences in interfacial film thickness). We present a testable model of the hypothetical differential interfacial depth distribution of protein analytes on FET sensor interfaces with distinct morphologies. Empirical validation of this model may rationalize the actual behaviour of planar immunoFETs, which has been shown to be contrary to expectations of bio/immunoFET behaviour prevalent in the literature for the last 20 years. Improved interfacial properties of bio/immunoHFETs have improved bio/immunoHFET performance: better understanding of interfaces may lead to mechanistic understanding of FET sensor properties and to clinical translation of the immunoFET platform.
- 29 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 11 (8) , 1726-1735
Improved Sensitivity of AlGaN/GaN Field Effect Transistor Biosensors by Optimized Surface Functionalization
In this paper, we optimize the AlGaN surface oxidation methods for AlGaN/GaN heterostructure field effect transistor (HFET) biological sensors. Reactive ion etching oxygen plasma, inductively coupled oxygen plasma, and piranha solution are used to oxidize AlGaN surface. After oxidation, X-ray photoelectron spectroscopy and water contact angle measurements are used to check oxidation effectiveness. Labeled streptavidin (SA) molecules are bound to the oxidized surface through linker molecules for comparison of surface modification effectiveness. Schottky diodes are fabricated to investigate the impacts of oxidation processes on electrical properties, such as Schottky barrier heights, sheet carrier concentrations, and interface trap densities. The results show that the inductively coupled plasma oxidation process has a superior behavior compared to the reactive ion etching oxygen plasma and piranha solution oxidation processes. AlGaN/GaN HFET protein sensors fabricated using the inductively coupled plasma oxidation process have exhibited improved sensitivity. An SA solution with the concentration as low as 4.73 pM were successfully detected.
- 29 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 11 (8) , 1726-1735
Improved Sensitivity of AlGaN/GaN Field Effect Transistor Biosensors by Optimized Surface Functionalization
In this paper, we optimize the AlGaN surface oxidation methods for AlGaN/GaN heterostructure field effect transistor (HFET) biological sensors. Reactive ion etching oxygen plasma, inductively coupled oxygen plasma, and piranha solution are used to oxidize AlGaN surface. After oxidation, X-ray photoelectron spectroscopy and water contact angle measurements are used to check oxidation effectiveness. Labeled streptavidin (SA) molecules are bound to the oxidized surface through linker molecules for comparison of surface modification effectiveness. Schottky diodes are fabricated to investigate the impacts of oxidation processes on electrical properties, such as Schottky barrier heights, sheet carrier concentrations, and interface trap densities. The results show that the inductively coupled plasma oxidation process has a superior behavior compared to the reactive ion etching oxygen plasma and piranha solution oxidation processes. AlGaN/GaN HFET protein sensors fabricated using the inductively coupled plasma oxidation process have exhibited improved sensitivity. An SA solution with the concentration as low as 4.73 pM were successfully detected.
- 1 November 2010
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 28 (6) , C6O21-C6O25
Fabrication and characterization of coupled metal-dielectric-metal nanoantennas
The authors fabricated two dimensional arrays of metal-dielectric-metal nanoantennas consisting of a thin layer of light-emitting polymers sandwiched between two Ag parallel cuboids and characterized them by measuring the optical transmission through the antenna arrays. The measured transmission spectra show two resonant dips. Numerical simulations reproduce the experimental results and show that the left dip is due to a cavity resonance mode and the right dip is due to the absorption of the polymer. With this vertical antenna design, the dielectric gap can be made much smaller with an extremely small mode volume, making it a potential candidate for single molecule studies using surface enhanced Raman scattering and for various other optoelectronic applications.
- 1 November 2010
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 28 (6) , C6O21-C6O25
Fabrication and characterization of coupled metal-dielectric-metal nanoantennas
The authors fabricated two dimensional arrays of metal-dielectric-metal nanoantennas consisting of a thin layer of light-emitting polymers sandwiched between two Ag parallel cuboids and characterized them by measuring the optical transmission through the antenna arrays. The measured transmission spectra show two resonant dips. Numerical simulations reproduce the experimental results and show that the left dip is due to a cavity resonance mode and the right dip is due to the absorption of the polymer. With this vertical antenna design, the dielectric gap can be made much smaller with an extremely small mode volume, making it a potential candidate for single molecule studies using surface enhanced Raman scattering and for various other optoelectronic applications.
- 26 October 2010
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (23) , 18199-18208
Formation and Finite Element Analysis of Tethered Bilayer Lipid Structures
Rapid solvent exchange of an ethanolic solution of diphytanoyl phosphatidylcholine (DPhyPC) in the presence of a mixed self-assembled monolayer (SAM) [thiolipid/β-mercaptoethanol (βME) (3/7 mol/mol) on Au] shows a transition from densely packed tethered bilayer lipid membranes [(dp)tBLMs], to loosely packed tethered bilayer lipid membranes [(lp)tBLMs], and tethered bilayer liposome nanoparticles (tBLNs) with decreasing DPhyPC concentration. The tethered lipidic constructs in the aqueous medium were analyzed by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). Finite element analysis (FEA) was applied to interpret spectral EIS features without referring to equivalent circuit modeling. Using structural data obtained earlier from neutron reflectometry and dielectric constants of lipid bilayers, we reproduced experimentally observed features of the electrochemical impedance (EI) spectra of complex surface constructs involving small pinhole defects, large membrane-free patches, and bound liposomes. We demonstrated by FEA that highly insulating (dp)tBLMs with low-defect density exhibit EI spectra in the shape of a perfect semicircle with or without low-frequency upward “tails” in the Cole−Cole representation. Such EI spectra were observed at DPhyPC concentrations of >5 × 10−3 mol L−1. While AFM was not able to visualize very small lateral defects in such films, EI spectra unambiguously signaled their presence by increased low frequency “tails”. Using FEA we demonstrate that films with large diameter visible defects (>25 nm by AFM) produce EI spectral features consisting of two semicircles of comparable size. Such films were typically obtained at DPhyPC concentrations of −3 mol L−1. At DPhyPC concentrations of −3 mol L−1 the planar bilayer structures were replaced by ellipsoidal liposomes with diameters ranging from 50 to 500 nm as observed in AFM images. Despite the distinct surface morphology change, the EI curves exhibited two semicircle spectral features typical for the large size defects in planar tBLMs. FEA revealed that, to account for these EI features for bound liposome systems (50−500 nm diameter), one needs to assume much lower tBLM conductivities of the submembrane space, which separates the electrode surface and the phospholipid bilayer. Alternatively, FEA indicates that such features may also be observed on composite surfaces containing both bound liposomes and patches of planar bilayers. Triple semicircular features, observed in some of the experimental EI curves, were attributed to an increased complexity of the real tBLMs. The modeling demonstrated that such features are typical for heterogeneous tBLM surfaces containing large patches of different defectiveness levels. By integrating AFM, EIS, and FEA data, our work provides diagnostic criteria allowing the precise characterization of the properties and the morphology of surface supported bilayer systems.
- 26 October 2010
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (23) , 18199-18208
Formation and Finite Element Analysis of Tethered Bilayer Lipid Structures
Rapid solvent exchange of an ethanolic solution of diphytanoyl phosphatidylcholine (DPhyPC) in the presence of a mixed self-assembled monolayer (SAM) [thiolipid/β-mercaptoethanol (βME) (3/7 mol/mol) on Au] shows a transition from densely packed tethered bilayer lipid membranes [(dp)tBLMs], to loosely packed tethered bilayer lipid membranes [(lp)tBLMs], and tethered bilayer liposome nanoparticles (tBLNs) with decreasing DPhyPC concentration. The tethered lipidic constructs in the aqueous medium were analyzed by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). Finite element analysis (FEA) was applied to interpret spectral EIS features without referring to equivalent circuit modeling. Using structural data obtained earlier from neutron reflectometry and dielectric constants of lipid bilayers, we reproduced experimentally observed features of the electrochemical impedance (EI) spectra of complex surface constructs involving small pinhole defects, large membrane-free patches, and bound liposomes. We demonstrated by FEA that highly insulating (dp)tBLMs with low-defect density exhibit EI spectra in the shape of a perfect semicircle with or without low-frequency upward “tails” in the Cole−Cole representation. Such EI spectra were observed at DPhyPC concentrations of >5 × 10−3 mol L−1. While AFM was not able to visualize very small lateral defects in such films, EI spectra unambiguously signaled their presence by increased low frequency “tails”. Using FEA we demonstrate that films with large diameter visible defects (>25 nm by AFM) produce EI spectral features consisting of two semicircles of comparable size. Such films were typically obtained at DPhyPC concentrations of −3 mol L−1. At DPhyPC concentrations of −3 mol L−1 the planar bilayer structures were replaced by ellipsoidal liposomes with diameters ranging from 50 to 500 nm as observed in AFM images. Despite the distinct surface morphology change, the EI curves exhibited two semicircle spectral features typical for the large size defects in planar tBLMs. FEA revealed that, to account for these EI features for bound liposome systems (50−500 nm diameter), one needs to assume much lower tBLM conductivities of the submembrane space, which separates the electrode surface and the phospholipid bilayer. Alternatively, FEA indicates that such features may also be observed on composite surfaces containing both bound liposomes and patches of planar bilayers. Triple semicircular features, observed in some of the experimental EI curves, were attributed to an increased complexity of the real tBLMs. The modeling demonstrated that such features are typical for heterogeneous tBLM surfaces containing large patches of different defectiveness levels. By integrating AFM, EIS, and FEA data, our work provides diagnostic criteria allowing the precise characterization of the properties and the morphology of surface supported bilayer systems.
- 1 December 2008
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 24 (4) , 505-511
Detection of clinically relevant levels of protein analyte under physiologic buffer using planar field effect transistors
- 1 December 2008
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 24 (4) , 505-511
Detection of clinically relevant levels of protein analyte under physiologic buffer using planar field effect transistors