Rashed Karim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rashed Karim has a total of 268 co-authors. Here are the top co-authors by number of shared publications:
- Kawal Rhode
School of Biomedical Engineering and Imaging Sciences, King’s College London, London SE1 7EH, UK
31 shared publications - Reza Razavi
King’s College London
23 shared publications - Tobias Schaeffter
Physikalisch‐Technische Bundesanstalt Berlin Germany
23 shared publications - Christopher Aldo Rinaldi
Guy’s and St Thomas’ Hospital & School of Biomedical Engineering and Imaging Sciences, King’s College London Department of Cardiology Westminster Bridge Road, London SE1 7EH
16 shared publications - Mark O' Neill
Division of Imaging Sciences and Biomedical Engineering King's College London London UK
12 shared publications Jaswinder Gill
Kings College London, London, UK
10 shared publications
Latest Publications
- 1 January 2021
- Published by Elsevier in Practical Radiation Oncology
- Vol. 11 (1) , 84-88
Novel Workflow for Conversion of Catheter-Based Electroanatomic Mapping to DICOM Imaging for Noninvasive Radioablation of Ventricular Tachycardia
- 1 January 2021
- Published by Elsevier in Practical Radiation Oncology
- Vol. 11 (1) , 84-88
Novel Workflow for Conversion of Catheter-Based Electroanatomic Mapping to DICOM Imaging for Noninvasive Radioablation of Ventricular Tachycardia
- Open Access
- 1 December 2020
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 13 (12) , e011512
Fully Automatic Atrial Fibrosis Assessment Using a Multilabel Convolutional Neural Network
Background: Pathological atrial fibrosis is a major contributor to sustained atrial fibrillation. Currently, late gadolinium enhancement (LGE) scans provide the only noninvasive estimate of atrial fibrosis. However, widespread adoption of atrial LGE has been hindered partly by nonstandardized image processing techniques, which can be operator and algorithm dependent. Minimal validation and limited access to transparent software platforms have also exacerbated the problem. This study aims to estimate atrial fibrosis from cardiac magnetic resonance scans using a reproducible operator-independent fully automatic open-source end-to-end pipeline. Methods: A multilabel convolutional neural network was designed to accurately delineate atrial structures including the blood pool, pulmonary veins, and mitral valve. The output from the network removed the operator dependent steps in a reproducible pipeline and allowed for automated estimation of atrial fibrosis from LGE-cardiac magnetic resonance scans. The pipeline results were compared against manual fibrosis burdens, calculated using published thresholds: image intensity ratio 0.97, image intensity ratio 1.61, and mean blood pool signal +3.3 SD. Results: We validated our methods on a large 3-dimensional LGE-cardiac magnetic resonance data set from 207 labeled scans. Automatic atrial segmentation achieved a 91% Dice score, compared with the mutual agreement of 85% in Dice seen in the interobserver analysis of operators. Intraclass correlation coefficients of the automatic pipeline with manually generated results were excellent and better than or equal to interobserver correlations for all 3 thresholds: 0.94 versus 0.88, 0.99 versus 0.99, 0.99 versus 0.96 for image intensity ratio 0.97, image intensity ratio 1.61, and +3.3 SD thresholds, respectively. Automatic analysis required 3 minutes per case on a standard workstation. The network and the analysis software are publicly available. Conclusions: Our pipeline provides a fully automatic estimation of fibrosis burden from LGE-cardiac magnetic resonance scans that is comparable to manual analysis. This removes one key source of variability in the measurement of atrial fibrosis.
- 1 December 2020
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 13 (12) , e011512
Open AccessFully Automatic Atrial Fibrosis Assessment Using a Multilabel Convolutional Neural Network
Background: Pathological atrial fibrosis is a major contributor to sustained atrial fibrillation. Currently, late gadolinium enhancement (LGE) scans provide the only noninvasive estimate of atrial fibrosis. However, widespread adoption of atrial LGE has been hindered partly by nonstandardized image processing techniques, which can be operator and algorithm dependent. Minimal validation and limited access to transparent software platforms have also exacerbated the problem. This study aims to estimate atrial fibrosis from cardiac magnetic resonance scans using a reproducible operator-independent fully automatic open-source end-to-end pipeline. Methods: A multilabel convolutional neural network was designed to accurately delineate atrial structures including the blood pool, pulmonary veins, and mitral valve. The output from the network removed the operator dependent steps in a reproducible pipeline and allowed for automated estimation of atrial fibrosis from LGE-cardiac magnetic resonance scans. The pipeline results were compared against manual fibrosis burdens, calculated using published thresholds: image intensity ratio 0.97, image intensity ratio 1.61, and mean blood pool signal +3.3 SD. Results: We validated our methods on a large 3-dimensional LGE-cardiac magnetic resonance data set from 207 labeled scans. Automatic atrial segmentation achieved a 91% Dice score, compared with the mutual agreement of 85% in Dice seen in the interobserver analysis of operators. Intraclass correlation coefficients of the automatic pipeline with manually generated results were excellent and better than or equal to interobserver correlations for all 3 thresholds: 0.94 versus 0.88, 0.99 versus 0.99, 0.99 versus 0.96 for image intensity ratio 0.97, image intensity ratio 1.61, and +3.3 SD thresholds, respectively. Automatic analysis required 3 minutes per case on a standard workstation. The network and the analysis software are publicly available. Conclusions: Our pipeline provides a fully automatic estimation of fibrosis burden from LGE-cardiac magnetic resonance scans that is comparable to manual analysis. This removes one key source of variability in the measurement of atrial fibrosis.
- Open Access
- 1 December 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 50, 36-53
Algorithms for left atrial wall segmentation and thickness – Evaluation on an open-source CT and MRI image database
- 1 December 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 50, 36-53
Open AccessAlgorithms for left atrial wall segmentation and thickness – Evaluation on an open-source CT and MRI image database
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 1111-1114
Image Data Analysis for Quantifying Scar Transmurality in MRI phantoms for Cardiac Resynchronisation Therapy
The use of implantable cardiac devices has increased in the last 30 years. Cardiac resynchronisation therapy (CRT) is a procedure which involves implanting a coin sized pacemaker for reversing heart failure. The pacemaker electrode leads are implanted into cardiac myocardial tissue. The optimal site for implantation is highly patient-specific. Most implanters use empirical placement of the lead. One region identified to have a poor response rate are myocardial tissue with transmural scar. Studies that precisely measure transmurality of scar tissue in the left ventricle (LV) are few. Most studies lack proper validation of their transmurality measurement technique. This study presents an image analysis technique for computing scar transmurality from late-gadolinium enhancement MRI. The technique is validated using phantoms under a CRT image guidance system. The study concludes that scar transmurality can be accurately measured in certain situations and validation with phantoms is important.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 1111-1114
Image Data Analysis for Quantifying Scar Transmurality in MRI phantoms for Cardiac Resynchronisation Therapy
The use of implantable cardiac devices has increased in the last 30 years. Cardiac resynchronisation therapy (CRT) is a procedure which involves implanting a coin sized pacemaker for reversing heart failure. The pacemaker electrode leads are implanted into cardiac myocardial tissue. The optimal site for implantation is highly patient-specific. Most implanters use empirical placement of the lead. One region identified to have a poor response rate are myocardial tissue with transmural scar. Studies that precisely measure transmurality of scar tissue in the left ventricle (LV) are few. Most studies lack proper validation of their transmurality measurement technique. This study presents an image analysis technique for computing scar transmurality from late-gadolinium enhancement MRI. The technique is validated using phantoms under a CRT image guidance system. The study concludes that scar transmurality can be accurately measured in certain situations and validation with phantoms is important.
- Open Access
- 1 July 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 47, 153-163
A work flow to build and validate patient specific left atrium electrophysiology models from catheter measurements
- 1 July 2018
- Published by Elsevier in Medical Image Analysis
- Vol. 47, 153-163
Open AccessA work flow to build and validate patient specific left atrium electrophysiology models from catheter measurements
- Open Access
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 30
Optimization of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 30
Open AccessOptimization of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
- Open Access
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 21-15
The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 21-15
Open AccessThe reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
- Open Access
- 14 September 2017
- Published by Computing in Cardiology
A Platform for Quantifying Atrial Structural Remodelling
- 14 September 2017
- Published by Computing in Cardiology
Open AccessA Platform for Quantifying Atrial Structural Remodelling
- Open Access
- 7 September 2017
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 50 (1) , 125-131
Standardized unfold mapping: a technique to permit left atrial regional data display and analysis
Left atrial arrhythmia substrate assessment can involve multiple imaging and electrical modalities, but visual analysis of data on 3D surfaces is time-consuming and suffers from limited reproducibility. Unfold maps (e.g., the left ventricular bull’s eye plot) allow 2D visualization, facilitate multimodal data representation, and provide a common reference space for inter-subject comparison. The aim of this work is to develop a method for automatic representation of multimodal information on a left atrial standardized unfold map (LA-SUM).
- 7 September 2017
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 50 (1) , 125-131
Open AccessStandardized unfold mapping: a technique to permit left atrial regional data display and analysis
Left atrial arrhythmia substrate assessment can involve multiple imaging and electrical modalities, but visual analysis of data on 3D surfaces is time-consuming and suffers from limited reproducibility. Unfold maps (e.g., the left ventricular bull’s eye plot) allow 2D visualization, facilitate multimodal data representation, and provide a common reference space for inter-subject comparison. The aim of this work is to develop a method for automatic representation of multimodal information on a left atrial standardized unfold map (LA-SUM).
- 4 September 2017
- Published by Springer Nature
- p. 377-385
CardiacNET: Segmentation of Left Atrium and Proximal Pulmonary Veins from MRI Using Multi-view CNN
- 4 September 2017
- Published by Springer Nature
- p. 377-385
CardiacNET: Segmentation of Left Atrium and Proximal Pulmonary Veins from MRI Using Multi-view CNN