Zaibin Jiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zaibin Jiao has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Jiawei Yuan
Xi’an Jiaotong University
12 shared publications - Jun Liu
Xi’an Jiaotong University
5 shared publications Xintong Liu
Power Transmission and Transformation Research Center, State Grid Ningbo Power Supply Company, Ningbo, China
5 shared publicationsYueming Ji
Power Transmission and Transformation Research Center, State Grid Lianyungang Power Supply Company, Lianyungang, China
5 shared publicationsHanwen Gu
Xi’an Jiaotong University
4 shared publicationsJiawei Yuan
3 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5012-5024
Frequency Regulation in Isolated Microgrids Considering Peak Frequency Deviation Suppression and Improved Resource Coordination
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5012-5024
Frequency Regulation in Isolated Microgrids Considering Peak Frequency Deviation Suppression and Improved Resource Coordination
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (5) , 3802-3817
Distributed Location Method for SPG Faults in Distribution Networks Combining Zero-Sequence and Phase-to-Phase Current Fault Components
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (5) , 3802-3817
Distributed Location Method for SPG Faults in Distribution Networks Combining Zero-Sequence and Phase-to-Phase Current Fault Components
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (2) , 724-739
Fault Diagnosis Method for Single-Phase-to-Ground Faults Based on Phase-to-Phase Current Fault Components in Distribution Networks
Accurate diagnosis of single-phase-to-ground (SPG) faults in distribution networks is essential for rapid fault isolation and reduced power interruptions. Existing approaches often address only one aspect of fault diagnosis, suffering from low reliability, heavy communication requirements, and high investment costs. To overcome these challenges, this paper presents a comprehensive fault diagnosis method based on phase-to-phase current fault components (PPCFC). The fault characteristics of PPCFCs are firstly analyzed on both the substation and feeder sides, taking into account the practical configuration of current detection devices. The results show that, in faulty feeders and sections, the fault-phase-related PPCFCs are significantly larger than the healthy-phase-related ones, while in healthy feeders and sound sections, all three PPCFCs remain close to zero. The PPCFCs are then calculated with consideration of possible triggering delays under high impedance faults, and their amplitude features are extracted. Based on this analysis, a fault phase and faulty feeder identification method is developed using PPCFCs from a single feeder at the substation side. In addition, a distributed location strategy is proposed, which employs local indicators to accurately determine the fault section via simple binary communication. Extensive experiments confirm its effectiveness and practicality.
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (2) , 724-739
Fault Diagnosis Method for Single-Phase-to-Ground Faults Based on Phase-to-Phase Current Fault Components in Distribution Networks
Accurate diagnosis of single-phase-to-ground (SPG) faults in distribution networks is essential for rapid fault isolation and reduced power interruptions. Existing approaches often address only one aspect of fault diagnosis, suffering from low reliability, heavy communication requirements, and high investment costs. To overcome these challenges, this paper presents a comprehensive fault diagnosis method based on phase-to-phase current fault components (PPCFC). The fault characteristics of PPCFCs are firstly analyzed on both the substation and feeder sides, taking into account the practical configuration of current detection devices. The results show that, in faulty feeders and sections, the fault-phase-related PPCFCs are significantly larger than the healthy-phase-related ones, while in healthy feeders and sound sections, all three PPCFCs remain close to zero. The PPCFCs are then calculated with consideration of possible triggering delays under high impedance faults, and their amplitude features are extracted. Based on this analysis, a fault phase and faulty feeder identification method is developed using PPCFCs from a single feeder at the substation side. In addition, a distributed location strategy is proposed, which employs local indicators to accurately determine the fault section via simple binary communication. Extensive experiments confirm its effectiveness and practicality.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (2) , 641-654
Faulty Feeder Detection Under High Impedance Faults Based on Harmonics of Calculated Fault Currents in Resonant Grounding Network
The identification of faulty feeders under high impedance faults (HIF) presents significant challenges due to weak fault currents and the difficulty in capturing transient components. Instead of relying on transient features, this paper proposes a faulty-feeder detection method for HIFs based on the harmonic characteristics of the calculated fault currents, and it is effective throughout the HIFs duration, which are immune from the fault triggering time. Firstly, the fault characteristics under HIFs are analyzed considering the nonlinear arcs, revealing that harmonic currents predominantly presented in the faulty feeder can be utilized for identification. Secondly, the fault currents at the fault points are calculated by subtracting the capacitive currents from the faulty-feeder zero-sequence currents (ZSC), significantly enhancing the nonlinear features in the ZSCs, whereas the calculated currents for healthy feeders essentially remain as capacitive currents with few arc-related distortions. A two-step fundamental component shift method is then developed to extract harmonic currents from these calculated fault currents. Thirdly, the energy proportion and kurtosis value are applied to describe the fault features of the extracted harmonics. Finally, a comprehensive detection scheme integrating harmonic energy and kurtosis criterion is proposed. Various test verifications demonstrate the feasibility and reliability of the proposed method.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (2) , 641-654
Faulty Feeder Detection Under High Impedance Faults Based on Harmonics of Calculated Fault Currents in Resonant Grounding Network
The identification of faulty feeders under high impedance faults (HIF) presents significant challenges due to weak fault currents and the difficulty in capturing transient components. Instead of relying on transient features, this paper proposes a faulty-feeder detection method for HIFs based on the harmonic characteristics of the calculated fault currents, and it is effective throughout the HIFs duration, which are immune from the fault triggering time. Firstly, the fault characteristics under HIFs are analyzed considering the nonlinear arcs, revealing that harmonic currents predominantly presented in the faulty feeder can be utilized for identification. Secondly, the fault currents at the fault points are calculated by subtracting the capacitive currents from the faulty-feeder zero-sequence currents (ZSC), significantly enhancing the nonlinear features in the ZSCs, whereas the calculated currents for healthy feeders essentially remain as capacitive currents with few arc-related distortions. A two-step fundamental component shift method is then developed to extract harmonic currents from these calculated fault currents. Thirdly, the energy proportion and kurtosis value are applied to describe the fault features of the extracted harmonics. Finally, a comprehensive detection scheme integrating harmonic energy and kurtosis criterion is proposed. Various test verifications demonstrate the feasibility and reliability of the proposed method.
- Open Access
- 20 November 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 173
Load probabilistic forecasting for electric vehicle charging station cluster: Adaptive multivariate spatiotemporal graph fusion technology
- 20 November 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 173
Open AccessLoad probabilistic forecasting for electric vehicle charging station cluster: Adaptive multivariate spatiotemporal graph fusion technology
- Open Access
- 29 September 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Power system transient stability assessment based on hierarchical graph pooling method considering missing data
- 29 September 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessPower system transient stability assessment based on hierarchical graph pooling method considering missing data
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (6) , 4502-4516
Faulty Feeder Detection for Successive Single Phase-to-Ground Faults Based on Complete Waveform Recognition and Segmentation Evaluation
When a single phase-to-ground (SPG) fault occurs in active distribution networks, over-voltage in healthy phases can potentially initiate a secondary SPG fault in other feeders. Existing detection techniques can only work under SPG faults while fail to identify the faulty feeders under this type of successive single phase-to-ground (SSPG) faults. To eliminate the blind zone of the existing methods, a novel hybrid data-physics driven detection method based on complete waveform recognition and segmentation evaluation is proposed in this paper. Firstly, the fault characteristics of zero-sequence currents (ZSC) under SSPG faults are analyzed. Secondly, a data-driven waveform recognition approach is introduced, utilizing the proposed deep feature fusion network to precisely extract complete fault characteristics from weak ZSCs. Thirdly, a comprehensive identification criterion is developed based on segmentation evaluation of the recognition results, with the physical mechanism of SSPG faults embedded into the process. In this framework, faulty feeders are identified through the effective integration of SSPG fault occurrence detection, fault component extraction, and feeder differentiation, thus significantly enhancing the detection reliability. Large amounts of simulation data and recorded data validate the satisfactory detection performance of the proposed method under various fault scenarios, illustrating its promising application prospects.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (6) , 4502-4516
Faulty Feeder Detection for Successive Single Phase-to-Ground Faults Based on Complete Waveform Recognition and Segmentation Evaluation
When a single phase-to-ground (SPG) fault occurs in active distribution networks, over-voltage in healthy phases can potentially initiate a secondary SPG fault in other feeders. Existing detection techniques can only work under SPG faults while fail to identify the faulty feeders under this type of successive single phase-to-ground (SSPG) faults. To eliminate the blind zone of the existing methods, a novel hybrid data-physics driven detection method based on complete waveform recognition and segmentation evaluation is proposed in this paper. Firstly, the fault characteristics of zero-sequence currents (ZSC) under SSPG faults are analyzed. Secondly, a data-driven waveform recognition approach is introduced, utilizing the proposed deep feature fusion network to precisely extract complete fault characteristics from weak ZSCs. Thirdly, a comprehensive identification criterion is developed based on segmentation evaluation of the recognition results, with the physical mechanism of SSPG faults embedded into the process. In this framework, faulty feeders are identified through the effective integration of SSPG fault occurrence detection, fault component extraction, and feeder differentiation, thus significantly enhancing the detection reliability. Large amounts of simulation data and recorded data validate the satisfactory detection performance of the proposed method under various fault scenarios, illustrating its promising application prospects.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (5) , 3489-3505
Train Diagram for Optimal Evacuation With Self-Adaptive Voltage Loss and Multi-Train Organization Constraints in Autotransformer Supply Systems
Power systems in remote areas are highly vulnerable, often leading to outages that disrupt traction power supply systems (TPSSs). This paper proposes a scheme to optimize the evacuation of electric locomotives within supply sections fed by an interconnected microgrid following the disconnection of the external power supply system (EPSS). Specifically, this paper begins by presenting a multi-train operational organization (MTOO) constraint, based on a velocity-time mesh, to create a train evacuation diagram that leverages a moving block system to prevent collisions. Next, it formulates self-adaptive voltage loss constraints tailored for high-capacity routes to maintain safe voltage levels. Finally, the paper brings forward device models, including Vv transformers, diesel generators, and energy storage systems considering negative sequence current (NSC) endurance, and establishes three-phase power flow constraints to ensure coordinated and optimal evacuation. The entire model is linearized into a mixed-integer linear programming (MILP) framework, and numerical results from two arms of a traction substation (TS) in a single-track autotransformer (AT) TPSS demonstrate the effectiveness of the well-crafted scheme.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (5) , 3489-3505
Train Diagram for Optimal Evacuation With Self-Adaptive Voltage Loss and Multi-Train Organization Constraints in Autotransformer Supply Systems
Power systems in remote areas are highly vulnerable, often leading to outages that disrupt traction power supply systems (TPSSs). This paper proposes a scheme to optimize the evacuation of electric locomotives within supply sections fed by an interconnected microgrid following the disconnection of the external power supply system (EPSS). Specifically, this paper begins by presenting a multi-train operational organization (MTOO) constraint, based on a velocity-time mesh, to create a train evacuation diagram that leverages a moving block system to prevent collisions. Next, it formulates self-adaptive voltage loss constraints tailored for high-capacity routes to maintain safe voltage levels. Finally, the paper brings forward device models, including Vv transformers, diesel generators, and energy storage systems considering negative sequence current (NSC) endurance, and establishes three-phase power flow constraints to ensure coordinated and optimal evacuation. The entire model is linearized into a mixed-integer linear programming (MILP) framework, and numerical results from two arms of a traction substation (TS) in a single-track autotransformer (AT) TPSS demonstrate the effectiveness of the well-crafted scheme.