Nevin Öztekin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nevin Öztekin has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Fatma Bedia Erim
Department of Chemistry, Istanbul Technical University, Maslak, Istanbul, Turkey
21 shared publications Nurfer Güngör
Istanbul Technical University, Department of Physics, Maslak 34469 Istanbul, Turkey
4 shared publicationsSelda Başkan
Department of Chemistry, Istanbul Technical University, Istanbul, Turkey
3 shared publications- Veselina Adımcılar
Department of Chemistry
3 shared publications Ayşe Alemdar
2 shared publications- Ebru Gunister
Department of Basic Sciences, Istanbul Galata University, Istanbul, Turkey
2 shared publications
Latest Publications
- 20 May 2026
- Published by Elsevier in Food Chemistry
- Vol. 519, 149702
Derivatization-free quantification of L-glutamic acid in commercial chips and sauces via capillary electrophoresis with contactless conductivity detection
- 20 May 2026
- Published by Elsevier in Food Chemistry
- Vol. 519, 149702
Derivatization-free quantification of L-glutamic acid in commercial chips and sauces via capillary electrophoresis with contactless conductivity detection
- 13 August 2025
- Published by Wiley in Biopolymers
- Vol. 116 (5) , e70043
Formulation and Characterization of Cerium Ion Cross‐Linked Alginate/PVA Films for Wound Dressing Applications
Herein, alginate films doped with cerium(III) carbonate were prepared via the casting method. An acid treatment process was applied to the films for cross‐linking by free Ce3+ ions. The incorporation of poly(vinyl) alcohol into the alginate matrix enhanced the film properties. Fourier transform infrared spectroscopy and differential scanning calorimetry analyses confirmed that PVA did not alter the chemical structure of the Ce/Alg films. Analysis of the morphological characteristics of Ce/Alg films using a scanning electron microscope revealed that porosity existed in the films. Cerium‐alginate films rapidly swell in PBS (pH = 7.4) and water within 10 min, demonstrating their potential for effective fluid absorption in wound environments. The water vapor permeability test exhibited that the films have the ability to transmit moisture. This present work reports the formulation of cerium(III) cross‐linked alginate films and characterization studies of the films. The films are regarded as subject to efficient wound coverage dressings in future studies with their favorable biomaterial properties.
- 13 August 2025
- Published by Wiley in Biopolymers
- Vol. 116 (5) , e70043
Formulation and Characterization of Cerium Ion Cross‐Linked Alginate/PVA Films for Wound Dressing Applications
Herein, alginate films doped with cerium(III) carbonate were prepared via the casting method. An acid treatment process was applied to the films for cross‐linking by free Ce3+ ions. The incorporation of poly(vinyl) alcohol into the alginate matrix enhanced the film properties. Fourier transform infrared spectroscopy and differential scanning calorimetry analyses confirmed that PVA did not alter the chemical structure of the Ce/Alg films. Analysis of the morphological characteristics of Ce/Alg films using a scanning electron microscope revealed that porosity existed in the films. Cerium‐alginate films rapidly swell in PBS (pH = 7.4) and water within 10 min, demonstrating their potential for effective fluid absorption in wound environments. The water vapor permeability test exhibited that the films have the ability to transmit moisture. This present work reports the formulation of cerium(III) cross‐linked alginate films and characterization studies of the films. The films are regarded as subject to efficient wound coverage dressings in future studies with their favorable biomaterial properties.
- Open Access
- 14 February 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (8) , 9040-9052
Comparison of Dye Adsorption of Chitosan and Polyethylenimine Modified Bentonite Clays: Optimization, Isotherm, and Kinetic Studies
The aim of this study was to compare the effect of modifying calcium bentonite (Bent-Ca) clay with two cationic polymers, chitosan (Chi) and polyethylenimine (PEI), on the removal of remazol black B (RB-B) dye from an aqueous solution. The samples were characterized by using scanning electron microscopy, X-ray diffraction, and Fourier-transform infrared spectroscopy. The fractional factorial design of 2(6-1) was applied to investigate the effects of pH, temperature, amount of adsorbent, initial dye concentration, contact time, and shaking rate on the adsorption process. To further optimize RB-B removal from an aqueous solution, a Box-Behnken design with three factors and a response surface methodology was used. The optimum conditions were a pH of 3.77, a temperature of 40.45 °C, and an initial RB-B concentration of 77.27 mg L-1 for Bent-Ca-Chi, whereas for Bent-Ca-PEI, the optimum conditions were a pH of 5.53, a temperature of 41.06 °C, and an initial dye concentration of 238.89 mg L-1. To understand the adsorption behavior, the Langmuir and Freundlich isotherms were fitted to the experimental data. It was found that the Langmuir isotherm model matched well with the dye adsorption by Bent-Ca-Chi and Bent-Ca-PEI. The kinetics study was performed using three kinetic models: pseudo-first-order, pseudo-second-order, and intraparticle diffusion models. Among these models, the RB-B dye kinetics were best represented by the pseudo-second-order model equation for the adsorbents.
- 14 February 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (8) , 9040-9052
Open AccessComparison of Dye Adsorption of Chitosan and Polyethylenimine Modified Bentonite Clays: Optimization, Isotherm, and Kinetic Studies
The aim of this study was to compare the effect of modifying calcium bentonite (Bent-Ca) clay with two cationic polymers, chitosan (Chi) and polyethylenimine (PEI), on the removal of remazol black B (RB-B) dye from an aqueous solution. The samples were characterized by using scanning electron microscopy, X-ray diffraction, and Fourier-transform infrared spectroscopy. The fractional factorial design of 2(6-1) was applied to investigate the effects of pH, temperature, amount of adsorbent, initial dye concentration, contact time, and shaking rate on the adsorption process. To further optimize RB-B removal from an aqueous solution, a Box-Behnken design with three factors and a response surface methodology was used. The optimum conditions were a pH of 3.77, a temperature of 40.45 °C, and an initial RB-B concentration of 77.27 mg L-1 for Bent-Ca-Chi, whereas for Bent-Ca-PEI, the optimum conditions were a pH of 5.53, a temperature of 41.06 °C, and an initial dye concentration of 238.89 mg L-1. To understand the adsorption behavior, the Langmuir and Freundlich isotherms were fitted to the experimental data. It was found that the Langmuir isotherm model matched well with the dye adsorption by Bent-Ca-Chi and Bent-Ca-PEI. The kinetics study was performed using three kinetic models: pseudo-first-order, pseudo-second-order, and intraparticle diffusion models. Among these models, the RB-B dye kinetics were best represented by the pseudo-second-order model equation for the adsorbents.
- 29 October 2023
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 238, 115826
Highly sensitive rapid determination of orotic acid in urine samples using a field-amplified sample stacking approach in capillary electrophoresis coupled with contactless conductivity detection
- 29 October 2023
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 238, 115826
Highly sensitive rapid determination of orotic acid in urine samples using a field-amplified sample stacking approach in capillary electrophoresis coupled with contactless conductivity detection
- 3 June 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (16) , e2300145
Separation and quantification of the urinary enantiomers of 2‐hydroxyglutaric acid by capillary electrophoresis with capacitively coupled contactless conductivity detection: Application to the diagnosis of D‐ and L‐2‐hydroxyglutaric aciduria
2‐hydroxyglutaric aciduria is an inherited neurometabolic disorder with two major types: D‐2‐hydroxyglutaric aciduria and L‐2‐hydroxyglutaric aciduria. An easy and fast capillary electrophoresis system combined with a capacitively coupled contactless conductivity detection method was developed for the enantioseparation and determination of D‐ and L‐2‐hydroxyglutaric acid in urine. D‐ and L‐2‐hydroxyglutaric acids were separated using vancomycin as the chiral selector. The optimal separation conditions for enantiomers were achieved by the use of a buffer containing 50 mM 4‐(N‐morpholino) butane sulfonic acid solution (pH 6.5), an electroosmotic flow modifier (0.001% [w/v] polybrene), and 30 mM vancomycin as chiral selector. The analysis time was 6 min under optimal conditions. The optimized and validated method was successfully implemented for quantifying D‐ and L‐2‐hydroxyglutaric aciduria in patients’ urine, without any pretreatment step. The linearity of the method was determined to be in the range of 2–100 mg/L for D‐ and L‐2‐hydroxyglutaric acid in urine. The precision (relative standard deviation%) was obtained at about 7%. For D‐ and L‐2‐hydroxyglutaric acids, the limits of detection were 0.567 and 0.497 mg/L, respectively.
- 3 June 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (16) , e2300145
Separation and quantification of the urinary enantiomers of 2‐hydroxyglutaric acid by capillary electrophoresis with capacitively coupled contactless conductivity detection: Application to the diagnosis of D‐ and L‐2‐hydroxyglutaric aciduria
2‐hydroxyglutaric aciduria is an inherited neurometabolic disorder with two major types: D‐2‐hydroxyglutaric aciduria and L‐2‐hydroxyglutaric aciduria. An easy and fast capillary electrophoresis system combined with a capacitively coupled contactless conductivity detection method was developed for the enantioseparation and determination of D‐ and L‐2‐hydroxyglutaric acid in urine. D‐ and L‐2‐hydroxyglutaric acids were separated using vancomycin as the chiral selector. The optimal separation conditions for enantiomers were achieved by the use of a buffer containing 50 mM 4‐(N‐morpholino) butane sulfonic acid solution (pH 6.5), an electroosmotic flow modifier (0.001% [w/v] polybrene), and 30 mM vancomycin as chiral selector. The analysis time was 6 min under optimal conditions. The optimized and validated method was successfully implemented for quantifying D‐ and L‐2‐hydroxyglutaric aciduria in patients’ urine, without any pretreatment step. The linearity of the method was determined to be in the range of 2–100 mg/L for D‐ and L‐2‐hydroxyglutaric acid in urine. The precision (relative standard deviation%) was obtained at about 7%. For D‐ and L‐2‐hydroxyglutaric acids, the limits of detection were 0.567 and 0.497 mg/L, respectively.
- 29 November 2020
- Published by Suleyman Demirel Universitesi Fen Edebiyat Fakultesi Fen Dergisi in Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
- Vol. 15 (2) , 194-202
İdrarda Orotik Asit’in Temassız İletkenlik Dedektörü Kullanılarak Kapiler Elektroforez Yöntemi İle Hızlı Tayini
İdrarda orotik asidin aşırı atılımı üre döngüsü bozukluğu ve pirimidin sentez bozukluğu gibi doğumsal metabolik hastalıklarda görülür. Bu nedenle orotik asidin hızlı bir şekilde tayini hayati öneme sahiptir. Bu çalışmada idrar örneklerinde orotik asidin kantitatif düzeylerinin belirlenmesi için yeni, basit, ucuz ve hızlı bir kapiler elektroforetik analiz yöntemi geliştirildi. Orotik asidin temassız iletkenlik dedektörü (C4D) kullanılarak kapiler elektroforez yöntemi ile ayrımı için pH’ı 6,5 olan 20 mM 4-Morfolinetansülfonik asit (MES), 10 mM Histidin ve 0,1 mM setil trimetilamonyum bromür (CTAB) içeren bir ça-lışma tamponu ile geliştirildi. Orotik asidin ayrılması yaklaşık 3,5 dakika gibi kısa bir sürede tamamlandı. Göç zamanlarının ve düzeltilmiş pik alanlarının tekrarlanabilirliği sırasıyla %RSD olarak 1,25 ve 4,31 olarak bulundu. En düşük dedeksiyon limiti (LOD) 0,733 mg / L ve en düşük tayin limiti de (LOQ) 2,443 mg / L olarak bulundu. Metodun idrarda orotik asit düzeylerinin tayin edilmesinde kolaylıkla ve hassasiyetle kullanılabileceği gösterildi.
- 29 November 2020
- Published by Suleyman Demirel Universitesi Fen Edebiyat Fakultesi Fen Dergisi in Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
- Vol. 15 (2) , 194-202
İdrarda Orotik Asit’in Temassız İletkenlik Dedektörü Kullanılarak Kapiler Elektroforez Yöntemi İle Hızlı Tayini
İdrarda orotik asidin aşırı atılımı üre döngüsü bozukluğu ve pirimidin sentez bozukluğu gibi doğumsal metabolik hastalıklarda görülür. Bu nedenle orotik asidin hızlı bir şekilde tayini hayati öneme sahiptir. Bu çalışmada idrar örneklerinde orotik asidin kantitatif düzeylerinin belirlenmesi için yeni, basit, ucuz ve hızlı bir kapiler elektroforetik analiz yöntemi geliştirildi. Orotik asidin temassız iletkenlik dedektörü (C4D) kullanılarak kapiler elektroforez yöntemi ile ayrımı için pH’ı 6,5 olan 20 mM 4-Morfolinetansülfonik asit (MES), 10 mM Histidin ve 0,1 mM setil trimetilamonyum bromür (CTAB) içeren bir ça-lışma tamponu ile geliştirildi. Orotik asidin ayrılması yaklaşık 3,5 dakika gibi kısa bir sürede tamamlandı. Göç zamanlarının ve düzeltilmiş pik alanlarının tekrarlanabilirliği sırasıyla %RSD olarak 1,25 ve 4,31 olarak bulundu. En düşük dedeksiyon limiti (LOD) 0,733 mg / L ve en düşük tayin limiti de (LOQ) 2,443 mg / L olarak bulundu. Metodun idrarda orotik asit düzeylerinin tayin edilmesinde kolaylıkla ve hassasiyetle kullanılabileceği gösterildi.
- 20 January 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (7) , 1365-1371
Capillary electrophoresis with capacitively coupled contactless conductivity detection for the determination of urinary ethylmalonic acid for the diagnosis of ethylmalonic aciduria
Ethylmalonic acid is a metabolic organic acid, and its accumulation in urine is diagnostic of ethylmalonic aciduria. In this study, a simple and fast method employing capillary electrophoresis equipped with capacitively coupled contactless conductivity detection was developed for the detection of ethylmalonic acid in urine samples. The optimized electrophoretic separation was performed in 50 mmol/L 2‐(N‐morpholino)ethanesulfonic acid solution, buffered at a pH of 6.5, and contained 0.13 mmol/L cetyltrimethylammonium bromide as an electroosmotic modifier. Electrophoresis was run at 28 kV in reversed polarity. The linear range of ethylmalonic acid concentration was between 1 and 100 mg/L with a regression coefficient of 0.9998. This method had good intra‐ and interday precision with <5% relative standard deviations. The detection limit (signal‐to‐noise ratio = 3) and the quantification limit (signal‐to‐noise ratio = 10) values were 0.139 and 0.466 mg/L, respectively. Using our optimized conditions, the method was successfully employed for the detection of ethylmalonic acid in urine sample of ethylmalonic aciduria patient.
- 20 January 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (7) , 1365-1371
Capillary electrophoresis with capacitively coupled contactless conductivity detection for the determination of urinary ethylmalonic acid for the diagnosis of ethylmalonic aciduria
Ethylmalonic acid is a metabolic organic acid, and its accumulation in urine is diagnostic of ethylmalonic aciduria. In this study, a simple and fast method employing capillary electrophoresis equipped with capacitively coupled contactless conductivity detection was developed for the detection of ethylmalonic acid in urine samples. The optimized electrophoretic separation was performed in 50 mmol/L 2‐(N‐morpholino)ethanesulfonic acid solution, buffered at a pH of 6.5, and contained 0.13 mmol/L cetyltrimethylammonium bromide as an electroosmotic modifier. Electrophoresis was run at 28 kV in reversed polarity. The linear range of ethylmalonic acid concentration was between 1 and 100 mg/L with a regression coefficient of 0.9998. This method had good intra‐ and interday precision with <5% relative standard deviations. The detection limit (signal‐to‐noise ratio = 3) and the quantification limit (signal‐to‐noise ratio = 10) values were 0.139 and 0.466 mg/L, respectively. Using our optimized conditions, the method was successfully employed for the detection of ethylmalonic acid in urine sample of ethylmalonic aciduria patient.
- 3 April 2019
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 43 (2) , 547-554
A fast and convenient analysis method for the determination of cations inpomegranate juices by capillary electrophoresis with contactless conductivitydetection
- 3 April 2019
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 43 (2) , 547-554
A fast and convenient analysis method for the determination of cations inpomegranate juices by capillary electrophoresis with contactless conductivitydetection
- 30 March 2018
- Published by Wiley in Biomedical Chromatography
- Vol. 32 (7) , e4216
Determination of homogentisic acid in urine for diagnosis of alcaptonuria: Capillary electrophoretic method optimization using experimental design
Homogentisic acid (HGA) is a diagnostic metabolite that accumulates in the urine and tissues of patients with alkaptonuria which is a rare autosomal recessive disease. HGA is a specific metabolite in urine and serum, which is used for diagnosis of alkaptonuria. This study presents an inexpensive and easy capillary electrophoretic method for the quantitative determination of HGA in urine samples. The method was optimized using full factorial experimental design. The optimal separation electrolyte and separation voltage were revealed as 45 mmol/L phosphate buffer at pH 7.0 and 22 kV, respectively. Under these conditions the presence of HGA was detected in 6 min. Repeatability of migration times and corrected peak areas of HGA (as RSD) were 0.37 and 1.99, respectively. The detection limit was 0.56 μg/mL, 3 times of the average noise, and the quantification limit was 1.85 μg/mL, 10 times the average noise for HGA. Urine samples were directly injected to the capillary without any pretreatment step.
- 30 March 2018
- Published by Wiley in Biomedical Chromatography
- Vol. 32 (7) , e4216
Determination of homogentisic acid in urine for diagnosis of alcaptonuria: Capillary electrophoretic method optimization using experimental design
Homogentisic acid (HGA) is a diagnostic metabolite that accumulates in the urine and tissues of patients with alkaptonuria which is a rare autosomal recessive disease. HGA is a specific metabolite in urine and serum, which is used for diagnosis of alkaptonuria. This study presents an inexpensive and easy capillary electrophoretic method for the quantitative determination of HGA in urine samples. The method was optimized using full factorial experimental design. The optimal separation electrolyte and separation voltage were revealed as 45 mmol/L phosphate buffer at pH 7.0 and 22 kV, respectively. Under these conditions the presence of HGA was detected in 6 min. Repeatability of migration times and corrected peak areas of HGA (as RSD) were 0.37 and 1.99, respectively. The detection limit was 0.56 μg/mL, 3 times of the average noise, and the quantification limit was 1.85 μg/mL, 10 times the average noise for HGA. Urine samples were directly injected to the capillary without any pretreatment step.
- Open Access
- 1 January 2018
- Published by Scientific Web Journals (SWJ) in Food and Health
- p. 176-182
SIMULTANEOUS DETERMINATION OF BENZOIC ACID AND SORBIC ACID IN FOOD PRODUCTS BY CAPILLARY ELECTROPHORESIS
- 1 January 2018
- Published by Scientific Web Journals (SWJ) in Food and Health
- p. 176-182
Open AccessSIMULTANEOUS DETERMINATION OF BENZOIC ACID AND SORBIC ACID IN FOOD PRODUCTS BY CAPILLARY ELECTROPHORESIS