Patrícia Andrade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Patrícia Andrade has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Guilherme Macedo
Department of Gastroenterology, São João University Hospital, 4200-319 Porto, Portugal
29 shared publications - Miguel Mascarenhas
Department of Community Medicine, Information and Health Decision Sciences (MEDCIDS), Faculty of Medicine, University of Porto, 4099-002 Porto, Portugal
15 shared publications - Hélder Cardoso
Precision Medicine Unit, Department of Gastroenterology, São João University Hospital, 4200-427 Porto, Portugal
13 shared publications - João Afonso
Precision Medicine Unit, Department of Gastroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal
12 shared publications - João Ferreira
Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
12 shared publications - Tiago Ribeiro
Gastroenterology Department, Centro Hospitalar Universitário de São João, Porto, Portugal
12 shared publications
Latest Publications
- Open Access
- 20 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (2) , 334
Robotic Capsule Endoscopy: Simultaneous Gastric and Enteric Evaluation in Real-World Practice
Background/Objectives: Robotic capsule endoscopy (RCE) is an emerging technology that combines magnetically controlled gastric navigation with conventional capsule enteroscopy (CE), enabling a minimally invasive, comprehensive evaluation of the upper- and mid-gastrointestinal tract. This study aimed to characterize the real-world implementation and diagnostic performance of RCE in a European tertiary referral center. Methods: A retrospective, single-center analysis was conducted on adult patients (≥18 years) who underwent RCE (Omom RC) between June 2023 and July 2025. Eligible patients had a clinical indication for small bowel CE and a concurrent requirement for diagnostic gastroscopy or reassessment of known gastric lesions. The RCE protocol comprised an initial robotic-guided gastric examination followed by passive transit through the small bowel. Results: A total of 85 patients were included (52% female), with a median age of 49 years (IQR 40–64). The most common indications were suspected or established inflammatory bowel disease (57%) and iron deficiency anemia (31%). Gastric preparation was rated at least fair in 98% of cases, with good preparation in 38%. Median gastric transit time was 74 min (IQR 35–106). Relevant gastric findings were identified in 39 cases (46%), namely polyps (18%) and angiectasias (8%, including one with active bleeding), in addition to signs of chronic gastritis. Thirteen patients underwent subsequent endoscopy, resulting in seven therapeutic procedures. Small bowel findings were present in 60 patients (71%), including P3 (active bleeding) in 3% and P2 lesions (angiectasias, ulcers, tumors, varices) in 39%. One moderate adverse event occurred: small bowel capsule retention in a patient with multifocal neuroendocrine tumor and ileostomy, requiring endoscopic intervention. Conclusions: Robotic capsule endoscopy is a feasible tool for dual-region gastrointestinal evaluation. It enables high-quality gastric visualization, facilitates early detection of clinically actionable lesions, and maintains the diagnostic yield expected from standard small bowel CE. These findings support the integration of RCE into diagnostic pathways for patients requiring simultaneous gastric and small bowel assessment.
- 20 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (2) , 334
Open AccessRobotic Capsule Endoscopy: Simultaneous Gastric and Enteric Evaluation in Real-World Practice
Background/Objectives: Robotic capsule endoscopy (RCE) is an emerging technology that combines magnetically controlled gastric navigation with conventional capsule enteroscopy (CE), enabling a minimally invasive, comprehensive evaluation of the upper- and mid-gastrointestinal tract. This study aimed to characterize the real-world implementation and diagnostic performance of RCE in a European tertiary referral center. Methods: A retrospective, single-center analysis was conducted on adult patients (≥18 years) who underwent RCE (Omom RC) between June 2023 and July 2025. Eligible patients had a clinical indication for small bowel CE and a concurrent requirement for diagnostic gastroscopy or reassessment of known gastric lesions. The RCE protocol comprised an initial robotic-guided gastric examination followed by passive transit through the small bowel. Results: A total of 85 patients were included (52% female), with a median age of 49 years (IQR 40–64). The most common indications were suspected or established inflammatory bowel disease (57%) and iron deficiency anemia (31%). Gastric preparation was rated at least fair in 98% of cases, with good preparation in 38%. Median gastric transit time was 74 min (IQR 35–106). Relevant gastric findings were identified in 39 cases (46%), namely polyps (18%) and angiectasias (8%, including one with active bleeding), in addition to signs of chronic gastritis. Thirteen patients underwent subsequent endoscopy, resulting in seven therapeutic procedures. Small bowel findings were present in 60 patients (71%), including P3 (active bleeding) in 3% and P2 lesions (angiectasias, ulcers, tumors, varices) in 39%. One moderate adverse event occurred: small bowel capsule retention in a patient with multifocal neuroendocrine tumor and ileostomy, requiring endoscopic intervention. Conclusions: Robotic capsule endoscopy is a feasible tool for dual-region gastrointestinal evaluation. It enables high-quality gastric visualization, facilitates early detection of clinically actionable lesions, and maintains the diagnostic yield expected from standard small bowel CE. These findings support the integration of RCE into diagnostic pathways for patients requiring simultaneous gastric and small bowel assessment.
- 10 October 2025
- Published by Elsevier in Clinical Gastroenterology and Hepatology
- Vol. 24 (8) , 2265-2272
AI-Assisted Capsule Endoscopy for Detection of Ulcers and Erosions in Crohn’s Disease: A Multicenter Validation Study
- 10 October 2025
- Published by Elsevier in Clinical Gastroenterology and Hepatology
- Vol. 24 (8) , 2265-2272
AI-Assisted Capsule Endoscopy for Detection of Ulcers and Erosions in Crohn’s Disease: A Multicenter Validation Study
- 28 August 2025
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 121 (4) , 993-1000
Real-Life Clinical Validation of Artificial Intelligence-Assisted Detection and Differentiation of Pleomorphic Lesions in Capsule Endoscopy
INTRODUCTION: Capsule endoscopy (CapE) is a minimally invasive procedure designed for small bowels' evaluation. However, prolonged reading times and a risk of missing clinically significant findings limit its potential. Prospective clinical validation studies of artificial intelligence (AI) for CapE remain scarce. Furthermore, existing studies focus on lesion detection, without addressing lesion differentiation. METHODS: The aim of a multicenter prospective validation study was to compare AI-assisted reading with conventional CapE reading. Three hundred thirty CapE videos from 3 devices across 7 centers and 4 countries were included. After conventional reading reports, AI-assisted reading was performed by an independent expert using a deep learning model to detect and differentiate pleomorphic small bowel lesions. Both reports were reviewed by an expert from an independent center, which decided in discrepant cases. AI-assisted and standard readings were evaluated through their accuracy, sensitivity, specificity, positive and negative predictive value, and small bowel lesion detection rate. RESULTS: AI-assisted reading detected 605 of 635 lesions identified by expert-based consensus, whereas standard reading identified 354 lesions. AI-assisted reading outperformed standard reading, with small bowel lesion detection rate of 96.1% vs 76.3% and sensitivity of 97.5% vs 78.2%. AI-assisted reading had a mean examination reading time of 203 seconds per examination. DISCUSSION: This was the first multicentric study proving AI-assisted CapE reading superiority compared with conventional reading. The inclusion of videos from multiple devices addresses the interoperability challenge, whereas including patients from 4 countries and 2 different continents assures a diverse demographic context. AI achieved gastroenterologist-level identification of small-bowel lesions, surpassing conventional reading methods in both lesion detection and characterization.
- 28 August 2025
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 121 (4) , 993-1000
Real-Life Clinical Validation of Artificial Intelligence-Assisted Detection and Differentiation of Pleomorphic Lesions in Capsule Endoscopy
INTRODUCTION: Capsule endoscopy (CapE) is a minimally invasive procedure designed for small bowels' evaluation. However, prolonged reading times and a risk of missing clinically significant findings limit its potential. Prospective clinical validation studies of artificial intelligence (AI) for CapE remain scarce. Furthermore, existing studies focus on lesion detection, without addressing lesion differentiation. METHODS: The aim of a multicenter prospective validation study was to compare AI-assisted reading with conventional CapE reading. Three hundred thirty CapE videos from 3 devices across 7 centers and 4 countries were included. After conventional reading reports, AI-assisted reading was performed by an independent expert using a deep learning model to detect and differentiate pleomorphic small bowel lesions. Both reports were reviewed by an expert from an independent center, which decided in discrepant cases. AI-assisted and standard readings were evaluated through their accuracy, sensitivity, specificity, positive and negative predictive value, and small bowel lesion detection rate. RESULTS: AI-assisted reading detected 605 of 635 lesions identified by expert-based consensus, whereas standard reading identified 354 lesions. AI-assisted reading outperformed standard reading, with small bowel lesion detection rate of 96.1% vs 76.3% and sensitivity of 97.5% vs 78.2%. AI-assisted reading had a mean examination reading time of 203 seconds per examination. DISCUSSION: This was the first multicentric study proving AI-assisted CapE reading superiority compared with conventional reading. The inclusion of videos from multiple devices addresses the interoperability challenge, whereas including patients from 4 countries and 2 different continents assures a diverse demographic context. AI achieved gastroenterologist-level identification of small-bowel lesions, surpassing conventional reading methods in both lesion detection and characterization.
- Open Access
- 13 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 709
Deep Learning and Automatic Detection of Pleomorphic Esophageal Lesions—A Necessary Step for Minimally Invasive Panendoscopy
Background: Capsule endoscopy (CE) improved the digestive tract assessment; yet, its reading burden is substantial. Deep-learning (DL) algorithms were developed for the detection of enteric and gastric lesions. Nonetheless, their application in the esophagus lacks evidence. The study aim was to develop a DL model for esophageal pleomorphic lesion (PL) detection. Methods: A bicentric retrospective study was conducted using 598 CE exams. Three different CE devices provided 7982 esophageal frames, including 2942 PL lesions. The data were divided into the training/validation and test groups, in a patient-split design. Three runs were conducted, each with unique patient sets. The sensitivity, specificity, accuracy, positive and negative predictive value (PPV and NPV), area under the conventional receiver operating characteristic curve (AUC-ROC), and precision–recall curve (AUC-PR) were calculated per run. The model’s diagnostic performance was assessed using the median and range values. Results: The median sensitivity, specificity, PPV, and NPV were 75.8% (63.6–82.1%), 95.8% (93.7–97.9%), 71.9% (50.0–90.1%), and 96.4% (94.2–97.6%), respectively. The median accuracy was 93.5% (91.8–93.8%). The median AUC-ROC and AUC-PR were 0.82 and 0.93. Conclusions: This study focused on the automatic detection of pleomorphic esophageal lesions, potentially enhancing the diagnostic yield of this type of lesion, compared to conventional methods. Specific esophageal DL algorithms may provide a significant contribution and bridge the gap for the implementation of minimally invasive CE-enhanced panendoscopy.
- 13 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 709
Open AccessDeep Learning and Automatic Detection of Pleomorphic Esophageal Lesions—A Necessary Step for Minimally Invasive Panendoscopy
Background: Capsule endoscopy (CE) improved the digestive tract assessment; yet, its reading burden is substantial. Deep-learning (DL) algorithms were developed for the detection of enteric and gastric lesions. Nonetheless, their application in the esophagus lacks evidence. The study aim was to develop a DL model for esophageal pleomorphic lesion (PL) detection. Methods: A bicentric retrospective study was conducted using 598 CE exams. Three different CE devices provided 7982 esophageal frames, including 2942 PL lesions. The data were divided into the training/validation and test groups, in a patient-split design. Three runs were conducted, each with unique patient sets. The sensitivity, specificity, accuracy, positive and negative predictive value (PPV and NPV), area under the conventional receiver operating characteristic curve (AUC-ROC), and precision–recall curve (AUC-PR) were calculated per run. The model’s diagnostic performance was assessed using the median and range values. Results: The median sensitivity, specificity, PPV, and NPV were 75.8% (63.6–82.1%), 95.8% (93.7–97.9%), 71.9% (50.0–90.1%), and 96.4% (94.2–97.6%), respectively. The median accuracy was 93.5% (91.8–93.8%). The median AUC-ROC and AUC-PR were 0.82 and 0.93. Conclusions: This study focused on the automatic detection of pleomorphic esophageal lesions, potentially enhancing the diagnostic yield of this type of lesion, compared to conventional methods. Specific esophageal DL algorithms may provide a significant contribution and bridge the gap for the implementation of minimally invasive CE-enhanced panendoscopy.
- Open Access
- 19 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (18) , 2072
A Comprehensive Review of Artificial Intelligence and Colon Capsule Endoscopy: Opportunities and Challenges
Colon capsule endoscopy (CCE) enables a comprehensive, non-invasive, and painless evaluation of the colon, although it still has limited indications. The lengthy reading times hinder its wider implementation, a drawback that could potentially be overcome through the integration of artificial intelligence (AI) models. Studies employing AI, particularly convolutional neural networks (CNNs), demonstrate great promise in using CCE as a viable option for detecting certain diseases and alterations in the colon, compared to other methods like colonoscopy. Additionally, employing AI models in CCE could pave the way for a minimally invasive panenteric or even panendoscopic solution. This review aims to provide a comprehensive summary of the current state-of-the-art of AI in CCE while also addressing the challenges, both technical and ethical, associated with broadening indications for AI-powered CCE. Additionally, it also gives a brief reflection of the potential environmental advantages of using this method compared to alternative ones.
- 19 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (18) , 2072
Open AccessA Comprehensive Review of Artificial Intelligence and Colon Capsule Endoscopy: Opportunities and Challenges
Colon capsule endoscopy (CCE) enables a comprehensive, non-invasive, and painless evaluation of the colon, although it still has limited indications. The lengthy reading times hinder its wider implementation, a drawback that could potentially be overcome through the integration of artificial intelligence (AI) models. Studies employing AI, particularly convolutional neural networks (CNNs), demonstrate great promise in using CCE as a viable option for detecting certain diseases and alterations in the colon, compared to other methods like colonoscopy. Additionally, employing AI models in CCE could pave the way for a minimally invasive panenteric or even panendoscopic solution. This review aims to provide a comprehensive summary of the current state-of-the-art of AI in CCE while also addressing the challenges, both technical and ethical, associated with broadening indications for AI-powered CCE. Additionally, it also gives a brief reflection of the potential environmental advantages of using this method compared to alternative ones.
- Open Access
- 29 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (3) , 291
From Data to Insights: How Is AI Revolutionizing Small-Bowel Endoscopy?
The role of capsule endoscopy and enteroscopy in managing various small-bowel pathologies is well-established. However, their broader application has been hampered mainly by their lengthy reading times. As a result, there is a growing interest in employing artificial intelligence (AI) in these diagnostic and therapeutic procedures, driven by the prospect of overcoming some major limitations and enhancing healthcare efficiency, while maintaining high accuracy levels. In the past two decades, the applicability of AI to gastroenterology has been increasing, mainly because of the strong imaging component. Nowadays, there are a multitude of studies using AI, specifically using convolutional neural networks, that prove the potential applications of AI to these endoscopic techniques, achieving remarkable results. These findings suggest that there is ample opportunity for AI to expand its presence in the management of gastroenterology diseases and, in the future, catalyze a game-changing transformation in clinical activities. This review provides an overview of the current state-of-the-art of AI in the scope of small-bowel study, with a particular focus on capsule endoscopy and enteroscopy.
- 29 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (3) , 291
Open AccessFrom Data to Insights: How Is AI Revolutionizing Small-Bowel Endoscopy?
The role of capsule endoscopy and enteroscopy in managing various small-bowel pathologies is well-established. However, their broader application has been hampered mainly by their lengthy reading times. As a result, there is a growing interest in employing artificial intelligence (AI) in these diagnostic and therapeutic procedures, driven by the prospect of overcoming some major limitations and enhancing healthcare efficiency, while maintaining high accuracy levels. In the past two decades, the applicability of AI to gastroenterology has been increasing, mainly because of the strong imaging component. Nowadays, there are a multitude of studies using AI, specifically using convolutional neural networks, that prove the potential applications of AI to these endoscopic techniques, achieving remarkable results. These findings suggest that there is ample opportunity for AI to expand its presence in the management of gastroenterology diseases and, in the future, catalyze a game-changing transformation in clinical activities. This review provides an overview of the current state-of-the-art of AI in the scope of small-bowel study, with a particular focus on capsule endoscopy and enteroscopy.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Therapeutic Advances in Gastroenterology
- Vol. 17
Deep learning and minimally invasive inflammatory activity assessment: a proof-of-concept study for development and score correlation of a panendoscopy convolutional network
Background: Capsule endoscopy (CE) is a valuable tool for assessing inflammation in patients with Crohn’s disease (CD). The current standard for evaluating inflammation are validated scores (and clinical laboratory values) like Lewis score (LS), Capsule Endoscopy Crohn’s Disease Activity Index (CECDAI), and ELIAKIM. Recent advances in artificial intelligence (AI) have made it possible to automatically select the most relevant frames in CE. Objectives: In this proof-of-concept study, our objective was to develop an automated scoring system using CE images to objectively grade inflammation. Design: Pan-enteric CE videos (PillCam Crohn’s) performed in CD patients between 09/2020 and 01/2023 were retrospectively reviewed and LS, CECDAI, and ELIAKIM scores were calculated. Methods: We developed a convolutional neural network-based automated score consisting of the percentage of positive frames selected by the algorithm (for small bowel and colon separately). We correlated clinical data and the validated scores with the artificial intelligence-generated score (AIS). Results: A total of 61 patients were included. The median LS was 225 (0–6006), CECDAI was 6 (0–33), ELIAKIM was 4 (0–38), and SB_AIS was 0.5659 (0–29.45). We found a strong correlation between SB_AIS and LS, CECDAI, and ELIAKIM scores (Spearman’s r = 0.751, r = 0.707, r = 0.655, p = 0.001). We found a strong correlation between LS and ELIAKIM ( r = 0.768, p = 0.001) and a very strong correlation between CECDAI and LS ( r = 0.854, p = 0.001) and CECDAI and ELIAKIM scores ( r = 0.827, p = 0.001). Conclusion: Our study showed that the AI-generated score had a strong correlation with validated scores indicating that it could serve as an objective and efficient method for evaluating inflammation in CD patients. As a preliminary study, our findings provide a promising basis for future refining of a CE score that may accurately correlate with prognostic factors and aid in the management and treatment of CD patients.
- 1 January 2024
- Published by SAGE Publications in Therapeutic Advances in Gastroenterology
- Vol. 17
Open AccessDeep learning and minimally invasive inflammatory activity assessment: a proof-of-concept study for development and score correlation of a panendoscopy convolutional network
Background: Capsule endoscopy (CE) is a valuable tool for assessing inflammation in patients with Crohn’s disease (CD). The current standard for evaluating inflammation are validated scores (and clinical laboratory values) like Lewis score (LS), Capsule Endoscopy Crohn’s Disease Activity Index (CECDAI), and ELIAKIM. Recent advances in artificial intelligence (AI) have made it possible to automatically select the most relevant frames in CE. Objectives: In this proof-of-concept study, our objective was to develop an automated scoring system using CE images to objectively grade inflammation. Design: Pan-enteric CE videos (PillCam Crohn’s) performed in CD patients between 09/2020 and 01/2023 were retrospectively reviewed and LS, CECDAI, and ELIAKIM scores were calculated. Methods: We developed a convolutional neural network-based automated score consisting of the percentage of positive frames selected by the algorithm (for small bowel and colon separately). We correlated clinical data and the validated scores with the artificial intelligence-generated score (AIS). Results: A total of 61 patients were included. The median LS was 225 (0–6006), CECDAI was 6 (0–33), ELIAKIM was 4 (0–38), and SB_AIS was 0.5659 (0–29.45). We found a strong correlation between SB_AIS and LS, CECDAI, and ELIAKIM scores (Spearman’s r = 0.751, r = 0.707, r = 0.655, p = 0.001). We found a strong correlation between LS and ELIAKIM ( r = 0.768, p = 0.001) and a very strong correlation between CECDAI and LS ( r = 0.854, p = 0.001) and CECDAI and ELIAKIM scores ( r = 0.827, p = 0.001). Conclusion: Our study showed that the AI-generated score had a strong correlation with validated scores indicating that it could serve as an objective and efficient method for evaluating inflammation in CD patients. As a preliminary study, our findings provide a promising basis for future refining of a CE score that may accurately correlate with prognostic factors and aid in the management and treatment of CD patients.
- Open Access
Artificial Intelligence and Panendoscopy—Automatic Detection of Clinically Relevant Lesions in Multibrand Device-Assisted Enteroscopy
Device-assisted enteroscopy (DAE) is capable of evaluating the entire gastrointestinal tract, identifying multiple lesions. Nevertheless, DAE’s diagnostic yield is suboptimal. Convolutional neural networks (CNN) are multi-layer architecture artificial intelligence models suitable for image analysis, but there is a lack of studies about their application in DAE. Our group aimed to develop a multidevice CNN for panendoscopic detection of clinically relevant lesions during DAE. In total, 338 exams performed in two specialized centers were retrospectively evaluated, with 152 single-balloon enteroscopies (Fujifilm®, Porto, Portugal), 172 double-balloon enteroscopies (Olympus®, Porto, Portugal) and 14 motorized spiral enteroscopies (Olympus®, Porto, Portugal); then, 40,655 images were divided in a training dataset (90% of the images, n = 36,599) and testing dataset (10% of the images, n = 4066) used to evaluate the model. The CNN’s output was compared to an expert consensus classification. The model was evaluated by its sensitivity, specificity, positive (PPV) and negative predictive values (NPV), accuracy and area under the precision recall curve (AUC-PR). The CNN had an 88.9% sensitivity, 98.9% specificity, 95.8% PPV, 97.1% NPV, 96.8% accuracy and an AUC-PR of 0.97. Our group developed the first multidevice CNN for panendoscopic detection of clinically relevant lesions during DAE. The development of accurate deep learning models is of utmost importance for increasing the diagnostic yield of DAE-based panendoscopy.
Open AccessArtificial Intelligence and Panendoscopy—Automatic Detection of Clinically Relevant Lesions in Multibrand Device-Assisted Enteroscopy
Device-assisted enteroscopy (DAE) is capable of evaluating the entire gastrointestinal tract, identifying multiple lesions. Nevertheless, DAE’s diagnostic yield is suboptimal. Convolutional neural networks (CNN) are multi-layer architecture artificial intelligence models suitable for image analysis, but there is a lack of studies about their application in DAE. Our group aimed to develop a multidevice CNN for panendoscopic detection of clinically relevant lesions during DAE. In total, 338 exams performed in two specialized centers were retrospectively evaluated, with 152 single-balloon enteroscopies (Fujifilm®, Porto, Portugal), 172 double-balloon enteroscopies (Olympus®, Porto, Portugal) and 14 motorized spiral enteroscopies (Olympus®, Porto, Portugal); then, 40,655 images were divided in a training dataset (90% of the images, n = 36,599) and testing dataset (10% of the images, n = 4066) used to evaluate the model. The CNN’s output was compared to an expert consensus classification. The model was evaluated by its sensitivity, specificity, positive (PPV) and negative predictive values (NPV), accuracy and area under the precision recall curve (AUC-PR). The CNN had an 88.9% sensitivity, 98.9% specificity, 95.8% PPV, 97.1% NPV, 96.8% accuracy and an AUC-PR of 0.97. Our group developed the first multidevice CNN for panendoscopic detection of clinically relevant lesions during DAE. The development of accurate deep learning models is of utmost importance for increasing the diagnostic yield of DAE-based panendoscopy.
- Open Access
The Future of Minimally Invasive Capsule Panendoscopy: Robotic Precision, Wireless Imaging and AI-Driven Insights
In the early 2000s, the introduction of single-camera wireless capsule endoscopy (CE) redefined small bowel study. Progress continued with the development of double-camera devices, first for the colon and rectum, and then, for panenteric assessment. Advancements continued with magnetic capsule endoscopy (MCE), particularly when assisted by a robotic arm, designed to enhance gastric evaluation. Indeed, as CE provides full visualization of the entire gastrointestinal (GI) tract, a minimally invasive capsule panendoscopy (CPE) could be a feasible alternative, despite its time-consuming nature and learning curve, assuming appropriate bowel cleansing has been carried out. Recent progress in artificial intelligence (AI), particularly in the development of convolutional neural networks (CNN) for CE auxiliary reading (detecting and diagnosing), may provide the missing link in fulfilling the goal of establishing the use of panendoscopy, although prospective studies are still needed to validate these models in actual clinical scenarios. Recent CE advancements will be discussed, focusing on the current evidence on CNN developments, and their real-life implementation potential and associated ethical challenges.
Open AccessThe Future of Minimally Invasive Capsule Panendoscopy: Robotic Precision, Wireless Imaging and AI-Driven Insights
In the early 2000s, the introduction of single-camera wireless capsule endoscopy (CE) redefined small bowel study. Progress continued with the development of double-camera devices, first for the colon and rectum, and then, for panenteric assessment. Advancements continued with magnetic capsule endoscopy (MCE), particularly when assisted by a robotic arm, designed to enhance gastric evaluation. Indeed, as CE provides full visualization of the entire gastrointestinal (GI) tract, a minimally invasive capsule panendoscopy (CPE) could be a feasible alternative, despite its time-consuming nature and learning curve, assuming appropriate bowel cleansing has been carried out. Recent progress in artificial intelligence (AI), particularly in the development of convolutional neural networks (CNN) for CE auxiliary reading (detecting and diagnosing), may provide the missing link in fulfilling the goal of establishing the use of panendoscopy, although prospective studies are still needed to validate these models in actual clinical scenarios. Recent CE advancements will be discussed, focusing on the current evidence on CNN developments, and their real-life implementation potential and associated ethical challenges.
- Open Access
- 21 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3494
AI-Driven Colon Cleansing Evaluation in Capsule Endoscopy: A Deep Learning Approach
Gastroenterology is increasingly moving towards minimally invasive diagnostic modalities. The diagnostic exploration of the colon via capsule endoscopy, both in specific protocols for colon capsule endoscopy and during panendoscopic evaluations, is increasingly regarded as an appropriate first-line diagnostic approach. Adequate colonic preparation is essential for conclusive examinations as, contrary to a conventional colonoscopy, the capsule moves passively in the colon and does not have the capacity to clean debris. Several scales have been developed for the classification of bowel preparation for colon capsule endoscopy. Nevertheless, their applications are limited by suboptimal interobserver agreement. Our group developed a deep learning algorithm for the automatic classification of colonic bowel preparation, according to an easily applicable classification. Our neural network achieved high performance levels, with a sensitivity of 91%, a specificity of 97% and an overall accuracy of 95%. The algorithm achieved a good discriminating capacity, with areas under the curve ranging between 0.92 and 0.97. The development of these algorithms is essential for the widespread adoption of capsule endoscopy for the exploration of the colon, as well as for the adoption of minimally invasive panendoscopy.
- 21 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (23) , 3494
Open AccessAI-Driven Colon Cleansing Evaluation in Capsule Endoscopy: A Deep Learning Approach
Gastroenterology is increasingly moving towards minimally invasive diagnostic modalities. The diagnostic exploration of the colon via capsule endoscopy, both in specific protocols for colon capsule endoscopy and during panendoscopic evaluations, is increasingly regarded as an appropriate first-line diagnostic approach. Adequate colonic preparation is essential for conclusive examinations as, contrary to a conventional colonoscopy, the capsule moves passively in the colon and does not have the capacity to clean debris. Several scales have been developed for the classification of bowel preparation for colon capsule endoscopy. Nevertheless, their applications are limited by suboptimal interobserver agreement. Our group developed a deep learning algorithm for the automatic classification of colonic bowel preparation, according to an easily applicable classification. Our neural network achieved high performance levels, with a sensitivity of 91%, a specificity of 97% and an overall accuracy of 95%. The algorithm achieved a good discriminating capacity, with areas under the curve ranging between 0.92 and 0.97. The development of these algorithms is essential for the widespread adoption of capsule endoscopy for the exploration of the colon, as well as for the adoption of minimally invasive panendoscopy.