Lianqing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lianqing Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Benyan Huo
Zhengzhou University
1 shared publication - Bi Zhang
State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
1 shared publication - Enming Shi
Shenyang Institute of Automation, Chinese Academy of Sciences,State Key Laboratory of Robotics and Intelligent Systems,Shenyang,110016
1 shared publication - Honghai Liu
Harbin Institute of Technology (Shenzhen)
1 shared publication - Liping Huang
Department of Rehabilitation Medicine, the First Medical Center, Chinese PLA General Hospital, Beijing, China
1 shared publication - Long Cheng
School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- 10 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/CAA Journal of Automatica Sinica
- Vol. 13 (2) , 259-280
A Systematic Review of Respiratory Monitoring and Assistance Techniques from a Pulmonary Rehabilitation Robot Perspective
Pulmonary rehabilitation (PR) aims to improve lung function in patients with chronic respiratory disease (CRD). In recent years, significant advancements have been made in pulmonary rehabilitation technologies, demonstrating their potential for enhancing lung function in patients with respiratory diseases. The purpose of this study is to outline recent developments in the field of pulmonary rehabilitation guided by pulmonary rehabilitation robots, which has not been previously addressed in earlier reviews. To fill this gap, this paper first provides a systematic summary of the monitoring and actuation technologies of pulmonary rehabilitation robot systems and evaluates these technologies from multiple dimensions, including portability, wearability potential, invasiveness, and clinical applications, analyzing the potential for integrating various technologies into pulmonary rehabilitation robot systems. Furthermore, three technical directions are proposed: real-time precise monitoring, suitable structure and actuation strategies, and the intelligence of pulmonary rehabilitation robot systems. On the basis of these directions, this paper presents a comprehensive technical outlook for a soft wearable pulmonary rehabilitation robot system, providing reference and guidance for future research. To our knowledge, this is the first review of pulmonary rehabilitation robot systems and their key technologies. Additionally, the review section on respiratory assistive technologies simultaneously covers key technologies such as mechanical ventilation (MV), exoskeleton robots, and functional electrical stimulation (FES) for the first time. It also summarizes the respiratory assistive technology paradigm from the innovative perspectives of respiratory assistive modalities, targeted body sites, and types of ventilation for the first time. This study offers a broader perspective and a deeper understanding of pulmonary re-habilitation robots, with a technical outlook encompassing multimodal data fusion perception, respiratory event detection and intention recognition, full-phase assistance strategies, modeling, decoupling, and quantification of multiple-input multiple-output (MIMO) systems, as well as model-based interactive control strategies.
- 10 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/CAA Journal of Automatica Sinica
- Vol. 13 (2) , 259-280
A Systematic Review of Respiratory Monitoring and Assistance Techniques from a Pulmonary Rehabilitation Robot Perspective
Pulmonary rehabilitation (PR) aims to improve lung function in patients with chronic respiratory disease (CRD). In recent years, significant advancements have been made in pulmonary rehabilitation technologies, demonstrating their potential for enhancing lung function in patients with respiratory diseases. The purpose of this study is to outline recent developments in the field of pulmonary rehabilitation guided by pulmonary rehabilitation robots, which has not been previously addressed in earlier reviews. To fill this gap, this paper first provides a systematic summary of the monitoring and actuation technologies of pulmonary rehabilitation robot systems and evaluates these technologies from multiple dimensions, including portability, wearability potential, invasiveness, and clinical applications, analyzing the potential for integrating various technologies into pulmonary rehabilitation robot systems. Furthermore, three technical directions are proposed: real-time precise monitoring, suitable structure and actuation strategies, and the intelligence of pulmonary rehabilitation robot systems. On the basis of these directions, this paper presents a comprehensive technical outlook for a soft wearable pulmonary rehabilitation robot system, providing reference and guidance for future research. To our knowledge, this is the first review of pulmonary rehabilitation robot systems and their key technologies. Additionally, the review section on respiratory assistive technologies simultaneously covers key technologies such as mechanical ventilation (MV), exoskeleton robots, and functional electrical stimulation (FES) for the first time. It also summarizes the respiratory assistive technology paradigm from the innovative perspectives of respiratory assistive modalities, targeted body sites, and types of ventilation for the first time. This study offers a broader perspective and a deeper understanding of pulmonary re-habilitation robots, with a technical outlook encompassing multimodal data fusion perception, respiratory event detection and intention recognition, full-phase assistance strategies, modeling, decoupling, and quantification of multiple-input multiple-output (MIMO) systems, as well as model-based interactive control strategies.
- 28 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 15 (5) , 398-411
Viscoelastic Properties Measurement of Human Lymphocytes by Atomic Force Microscopy Based on Magnetic Beads Cell Isolation
Cell mechanics has been proved to be an effective biomarker for indicating cellular states. The advent of atomic force microscopy (AFM) provides an exciting instrument for measuring the mechanical properties of single cells. However, current AFM single-cell mechanical measurements are commonly performed on cell lines cultured in vitro which are quite different from the primary cells in the human body. Investigating the mechanical properties of primary cells from clinical environments can help us to better understand cell behaviors. Here, by combining AFM with magnetic beads cell isolation, the viscoelastic properties of human primary B lymphocytes were quantitatively measured. B lymphocytes were isolated from the peripheral blood of healthy volunteers by density gradient centrifugation and CD19 magnetic beads cell isolation. The activity and specificity of the isolated cells were confirmed by fluorescence microscopy. AFM imaging revealed the surface topography and geometric parameters of B lymphocytes. The instantaneous modulus and relaxation time of living B lymphocytes were measured by AFM indenting technique, showing that the instantaneous modulus of human normal B lymphocytes was 2-3 kPa and the relaxation times were 0.03-0.06 s and 0.35-0.55 s. The differences in cellular visocoelastic properties between primary B lymphocytes and cell lines cultured in vitro were analyzed. The study proves the capability of AFM in quantifying the viscoelastic properties of individual specific primary cells from the blood sample of clinical patients, which will improve our understanding of the behaviors of cells in the human body.
- 28 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 15 (5) , 398-411
Viscoelastic Properties Measurement of Human Lymphocytes by Atomic Force Microscopy Based on Magnetic Beads Cell Isolation
Cell mechanics has been proved to be an effective biomarker for indicating cellular states. The advent of atomic force microscopy (AFM) provides an exciting instrument for measuring the mechanical properties of single cells. However, current AFM single-cell mechanical measurements are commonly performed on cell lines cultured in vitro which are quite different from the primary cells in the human body. Investigating the mechanical properties of primary cells from clinical environments can help us to better understand cell behaviors. Here, by combining AFM with magnetic beads cell isolation, the viscoelastic properties of human primary B lymphocytes were quantitatively measured. B lymphocytes were isolated from the peripheral blood of healthy volunteers by density gradient centrifugation and CD19 magnetic beads cell isolation. The activity and specificity of the isolated cells were confirmed by fluorescence microscopy. AFM imaging revealed the surface topography and geometric parameters of B lymphocytes. The instantaneous modulus and relaxation time of living B lymphocytes were measured by AFM indenting technique, showing that the instantaneous modulus of human normal B lymphocytes was 2-3 kPa and the relaxation times were 0.03-0.06 s and 0.35-0.55 s. The differences in cellular visocoelastic properties between primary B lymphocytes and cell lines cultured in vitro were analyzed. The study proves the capability of AFM in quantifying the viscoelastic properties of individual specific primary cells from the blood sample of clinical patients, which will improve our understanding of the behaviors of cells in the human body.