Marie-Hélène Roy Cardinal
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marie-Hélène Roy Cardinal has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Guy Cloutier
University of Montreal
17 shared publications Guy Cloutier
13 shared publications- Gilles Soulez
Department of Radiology and Nuclear Medicine, Centre Hospitalier de l’Université de Montréal (CHUM), Montreal, QC H2X 0C1, Canada
11 shared publications Gilles Soulez
Department of Radiology, University of Montreal Hospital (CHUM), Montreal, Quebec, Canada
7 shared publicationsBoris Chayer
Affiliation Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
6 shared publicationsFrançois Destrempes
Affiliation Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
4 shared publications
Latest Publications
- Open Access
- 19 June 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 237
Simultaneous viscoelastic characterization of soft tissues based on shear wave ultrasound dispersion and multi-scale wavelet cross-correlation analysis
- 19 June 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 237
Open AccessSimultaneous viscoelastic characterization of soft tissues based on shear wave ultrasound dispersion and multi-scale wavelet cross-correlation analysis
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1879-1896
A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients
The ultrasound backscatter coefficient is a frequency-dependent quantity intrinsic to biological tissues that can be recovered from backscattered radiofrequency signals, granted acquisitions on a reference phantom are available under the same system’s settings. A phantom-free backscatter coefficient estimation method is proposed based on Gaussian-shaped approximation of the point spread function (electronics and piezoelectric characteristics of the scanner’s probe) and the effective medium theory combined with the structure factor model, albeit the proposed approach is amenable to other models. Meanwhile, the total attenuation due to intervening tissues is refined from its theoretical value, which is based on reported average behaviors of tissues, while allowing correction for diffraction due to the probe’s geometry. The reference phantom method adapted to a similar approach except for the Gaussian approximation is also presented. The proposed phantom-free and reference phantom methods were compared on ten COVID-19 positive patients and twelve control subjects with measures on femoral veins and arteries. In this context, red blood cells are viewed as scatterers that form aggregates increasing the backscatter under the COVID-19 inflammatory condition. The considered model comprises five parameters, including the mean aggregate size estimated according to polydispersity of aggregates’ radii, and anisotropy of their shape. The mean aggregate size over the two proposed methods presented an intraclass correlation coefficient of 0.964 for consistency. The aggregate size presented a significant difference between the two groups with either two methods, despite the confounding effect of the maximum Doppler velocity within the blood vessel and its diameter.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1879-1896
A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients
The ultrasound backscatter coefficient is a frequency-dependent quantity intrinsic to biological tissues that can be recovered from backscattered radiofrequency signals, granted acquisitions on a reference phantom are available under the same system’s settings. A phantom-free backscatter coefficient estimation method is proposed based on Gaussian-shaped approximation of the point spread function (electronics and piezoelectric characteristics of the scanner’s probe) and the effective medium theory combined with the structure factor model, albeit the proposed approach is amenable to other models. Meanwhile, the total attenuation due to intervening tissues is refined from its theoretical value, which is based on reported average behaviors of tissues, while allowing correction for diffraction due to the probe’s geometry. The reference phantom method adapted to a similar approach except for the Gaussian approximation is also presented. The proposed phantom-free and reference phantom methods were compared on ten COVID-19 positive patients and twelve control subjects with measures on femoral veins and arteries. In this context, red blood cells are viewed as scatterers that form aggregates increasing the backscatter under the COVID-19 inflammatory condition. The considered model comprises five parameters, including the mean aggregate size estimated according to polydispersity of aggregates’ radii, and anisotropy of their shape. The mean aggregate size over the two proposed methods presented an intraclass correlation coefficient of 0.964 for consistency. The aggregate size presented a significant difference between the two groups with either two methods, despite the confounding effect of the maximum Doppler velocity within the blood vessel and its diameter.
- Open Access
Differential Impact of IL-32 Isoforms on the Functions of Coronary Artery Endothelial Cells: A Potential Link with Arterial Stiffness and Atherosclerosis
Chronic inflammation is associated with higher risk of cardiovascular disease (CVD) in people living with HIV (PLWH). We have previously shown that interleukin-32 (IL-32), a multi-isoform proinflammatory cytokine, is chronically upregulated in PLWH and is linked with CVD. However, the mechanistic roles of the different IL-32 isoforms in CVD are yet to be identified. In this study, we aimed to investigate the potential impact of IL-32 isoforms on coronary artery endothelial cells (CAEC), whose dysfunction represents a major factor for atherosclerosis. Our results demonstrated that the predominantly expressed IL-32 isoforms (IL-32β and IL-32γ) have a selective impact on the production of the proinflammatory cytokine IL-6 by CAEC. Furthermore, these two isoforms induced endothelial cell dysfunction by upregulating the expression of the adhesion molecules ICAM-I and VCAM-I and the chemoattractants CCL-2, CXCL-8 and CXCL-1. IL-32-mediated expression of these chemokines was sufficient to drive monocyte transmigration in vitro. Finally, we demonstrate that IL-32 expression in both PLWH and controls correlates with the carotid artery stiffness, measured by the cumulated lateral translation. These results suggest a role for IL-32-mediated endothelial cell dysfunction in dysregulation of the blood vessel wall and that IL-32 may represent a therapeutic target to prevent CVD in PLWH.
Open AccessDifferential Impact of IL-32 Isoforms on the Functions of Coronary Artery Endothelial Cells: A Potential Link with Arterial Stiffness and Atherosclerosis
Chronic inflammation is associated with higher risk of cardiovascular disease (CVD) in people living with HIV (PLWH). We have previously shown that interleukin-32 (IL-32), a multi-isoform proinflammatory cytokine, is chronically upregulated in PLWH and is linked with CVD. However, the mechanistic roles of the different IL-32 isoforms in CVD are yet to be identified. In this study, we aimed to investigate the potential impact of IL-32 isoforms on coronary artery endothelial cells (CAEC), whose dysfunction represents a major factor for atherosclerosis. Our results demonstrated that the predominantly expressed IL-32 isoforms (IL-32β and IL-32γ) have a selective impact on the production of the proinflammatory cytokine IL-6 by CAEC. Furthermore, these two isoforms induced endothelial cell dysfunction by upregulating the expression of the adhesion molecules ICAM-I and VCAM-I and the chemoattractants CCL-2, CXCL-8 and CXCL-1. IL-32-mediated expression of these chemokines was sufficient to drive monocyte transmigration in vitro. Finally, we demonstrate that IL-32 expression in both PLWH and controls correlates with the carotid artery stiffness, measured by the cumulated lateral translation. These results suggest a role for IL-32-mediated endothelial cell dysfunction in dysregulation of the blood vessel wall and that IL-32 may represent a therapeutic target to prevent CVD in PLWH.
- 21 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3284-3296
Ultrafast Myocardial Principal Strain Ultrasound Elastography During Stress Tests: In Vitro Validation and In Vivo Feasibility
Objective myocardial contractility assessment during stress tests aims to improve the diagnosis of myocardial ischemia. Tissue Doppler imaging (TDI) or optical flow (OF) speckle tracking echocardiography has been used to quantify myocardial contractility at rest. However, this is more challenging during stress tests due to image decorrelation at high heart rates. Moreover, stress tests imply a high frame rate which leads to a limited lateral field-of-view. Therefore, a large lateral field-of-view robust ultrafast myocardial regularized lateral field-of-view robust ultrafast myocardial regularized OF-TDI principal strain estimator has been developed for high-frame-rate echocardiography of coherently compounded transmitted diverging waves. Feasibility and accuracy of the proposed estimator were validated with in vitro (using sonomicrometry as gold standard) and in vivo stress experiments. Compared with OF strain imaging, the proposed estimator improved the accuracy of principal major and minor strains during stress tests, with an average contrast-to-noise ratio improvement of 4.4 ± 2.7 dB ( p -value < 0.01). Moreover, there was a significant correlation and a very close agreement between the proposed estimator and sonomicrometry for tested heart rates between 60 and 180 beats per minute. The averages ± STD of R 2 and biases ± STD between them were 0.96 ± 0.04 ( p -value < 0.01) and 0.01 ± 0.03 % in the axial direction, respectively; and 0.94 ± 0.02 ( p -value < 0.01) and 0.04 ± 0.06 % in the lateral direction, respectively. These results suggest that the proposed estimator could be useful clinically to provide an accurate and quantitative 2D large lateral field-of-view myocardial strain assessment at high heart rates during stress echocardiography.
- 21 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3284-3296
Ultrafast Myocardial Principal Strain Ultrasound Elastography During Stress Tests: In Vitro Validation and In Vivo Feasibility
Objective myocardial contractility assessment during stress tests aims to improve the diagnosis of myocardial ischemia. Tissue Doppler imaging (TDI) or optical flow (OF) speckle tracking echocardiography has been used to quantify myocardial contractility at rest. However, this is more challenging during stress tests due to image decorrelation at high heart rates. Moreover, stress tests imply a high frame rate which leads to a limited lateral field-of-view. Therefore, a large lateral field-of-view robust ultrafast myocardial regularized lateral field-of-view robust ultrafast myocardial regularized OF-TDI principal strain estimator has been developed for high-frame-rate echocardiography of coherently compounded transmitted diverging waves. Feasibility and accuracy of the proposed estimator were validated with in vitro (using sonomicrometry as gold standard) and in vivo stress experiments. Compared with OF strain imaging, the proposed estimator improved the accuracy of principal major and minor strains during stress tests, with an average contrast-to-noise ratio improvement of 4.4 ± 2.7 dB ( p -value < 0.01). Moreover, there was a significant correlation and a very close agreement between the proposed estimator and sonomicrometry for tested heart rates between 60 and 180 beats per minute. The averages ± STD of R 2 and biases ± STD between them were 0.96 ± 0.04 ( p -value < 0.01) and 0.01 ± 0.03 % in the axial direction, respectively; and 0.94 ± 0.02 ( p -value < 0.01) and 0.04 ± 0.06 % in the lateral direction, respectively. These results suggest that the proposed estimator could be useful clinically to provide an accurate and quantitative 2D large lateral field-of-view myocardial strain assessment at high heart rates during stress echocardiography.
- 9 February 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (5) , 495-504.e3
Strain Ultrasound Elastography of Aneurysm Sac Content after Randomized Endoleak Embolization with Sclerosing vs. Non-sclerosing Chitosan-based Hydrogels in a Canine Model
- 9 February 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (5) , 495-504.e3
Strain Ultrasound Elastography of Aneurysm Sac Content after Randomized Endoleak Embolization with Sclerosing vs. Non-sclerosing Chitosan-based Hydrogels in a Canine Model
- Open Access
- 27 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0262291
Quantitative ultrasound, elastography, and machine learning for assessment of steatosis, inflammation, and fibrosis in chronic liver disease
Objective: To develop a quantitative ultrasound (QUS)- and elastography-based model to improve classification of steatosis grade, inflammation grade, and fibrosis stage in patients with chronic liver disease in comparison with shear wave elastography alone, using histopathology as the reference standard. Methods: This ancillary study to a prospective institutional review-board approved study included 82 patients with non-alcoholic fatty liver disease, chronic hepatitis B or C virus, or autoimmune hepatitis. Elastography measurements, homodyned K-distribution parametric maps, and total attenuation coefficient slope were recorded. Random forests classification and bootstrapping were used to identify combinations of parameters that provided the highest diagnostic accuracy. Receiver operating characteristic (ROC) curves were computed. Results: For classification of steatosis grade S0 vs. S1-3, S0-1 vs. S2-3, S0-2 vs. S3, area under the receiver operating characteristic curve (AUC) were respectively 0.60, 0.63, and 0.62 with elasticity alone, and 0.90, 0.81, and 0.78 with the best tested model combining QUS and elastography features. For classification of inflammation grade A0 vs. A1-3, A0-1 vs. A2-3, A0-2 vs. A3, AUCs were respectively 0.56, 0.62, and 0.64 with elasticity alone, and 0.75, 0.68, and 0.69 with the best model. For classification of liver fibrosis stage F0 vs. F1-4, F0-1 vs. F2-4, F0-2 vs. F3-4, F0-3 vs. F4, AUCs were respectively 0.66, 0.77, 0.72, and 0.74 with elasticity alone, and 0.72, 0.77, 0.77, and 0.75 with the best model. Conclusion: Random forest models incorporating QUS and shear wave elastography increased the classification accuracy of liver steatosis, inflammation, and fibrosis when compared to shear wave elastography alone.
- 27 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0262291
Open AccessQuantitative ultrasound, elastography, and machine learning for assessment of steatosis, inflammation, and fibrosis in chronic liver disease
Objective: To develop a quantitative ultrasound (QUS)- and elastography-based model to improve classification of steatosis grade, inflammation grade, and fibrosis stage in patients with chronic liver disease in comparison with shear wave elastography alone, using histopathology as the reference standard. Methods: This ancillary study to a prospective institutional review-board approved study included 82 patients with non-alcoholic fatty liver disease, chronic hepatitis B or C virus, or autoimmune hepatitis. Elastography measurements, homodyned K-distribution parametric maps, and total attenuation coefficient slope were recorded. Random forests classification and bootstrapping were used to identify combinations of parameters that provided the highest diagnostic accuracy. Receiver operating characteristic (ROC) curves were computed. Results: For classification of steatosis grade S0 vs. S1-3, S0-1 vs. S2-3, S0-2 vs. S3, area under the receiver operating characteristic curve (AUC) were respectively 0.60, 0.63, and 0.62 with elasticity alone, and 0.90, 0.81, and 0.78 with the best tested model combining QUS and elastography features. For classification of inflammation grade A0 vs. A1-3, A0-1 vs. A2-3, A0-2 vs. A3, AUCs were respectively 0.56, 0.62, and 0.64 with elasticity alone, and 0.75, 0.68, and 0.69 with the best model. For classification of liver fibrosis stage F0 vs. F1-4, F0-1 vs. F2-4, F0-2 vs. F3-4, F0-3 vs. F4, AUCs were respectively 0.66, 0.77, 0.72, and 0.74 with elasticity alone, and 0.72, 0.77, 0.77, and 0.75 with the best model. Conclusion: Random forest models incorporating QUS and shear wave elastography increased the classification accuracy of liver steatosis, inflammation, and fibrosis when compared to shear wave elastography alone.
- 14 May 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (3) , 685-697
Impact of Applying a Skin Compression With the Ultrasound Probe on Carotid Artery Strain Elastography
Objective To study the impact of varying the external compression exerted by the ultrasound probe when performing a carotid strain elastography exam. Methods Nine healthy volunteers (mean age 43 years ±13 years; 6 men) underwent a vascular ultrasound elastography exam using a custom made sound feedback handle embedding the probe, and allowing the sonographer to adjust the applied compression. A clinical standard practice (SP) force was first recorded, and then predetermined compression (PDC) forces were applied, ranging from 0 to 5 N for the left common carotid artery (CCA) or 2–12 N for the left internal carotid artery (ICA). Six carotid elastography features, namely maximum and cumulated axial strains, maximum and cumulated shear strains, cumulated axial translation, and cumulated lateral translation were assessed with noninvasive vascular elastography (NIVE) on near and far walls of carotids. The carotid intima media thickness (IMT) and diameter were also measured. Results All elastography features on the near wall of both CCA and ICA decreased statistically significantly as the PDC force increased; this association was also observed for half of the features on the far wall. Three NIVE features at the lowest PDC force (out of 72 that were tested) were statistically significantly different than values at the SP force. Overall, NIVE showed some variance to probe compression with linear regression slopes revealing changes of 10.1%–45.6% in magnitude over the whole compression range on both walls. The maximum IMT for the ICA near wall, and carotid lumen diameters of both CCA and ICA were statistically significantly associated with PDC forces; these features underwent a decrease of 10.2%, 36.2%, and 17.6%, respectively, over the whole range of PDC force increase. Other IMT measurements were not statistically significantly associated with applied PDC forces. Conclusion These results suggest the need of technical guidelines for carotid strain elastography. Using the lowest probe compression while allowing a good B‐mode image quality is recommended to improve the robustness of NIVE measurements.
- 14 May 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (3) , 685-697
Impact of Applying a Skin Compression With the Ultrasound Probe on Carotid Artery Strain Elastography
Objective To study the impact of varying the external compression exerted by the ultrasound probe when performing a carotid strain elastography exam. Methods Nine healthy volunteers (mean age 43 years ±13 years; 6 men) underwent a vascular ultrasound elastography exam using a custom made sound feedback handle embedding the probe, and allowing the sonographer to adjust the applied compression. A clinical standard practice (SP) force was first recorded, and then predetermined compression (PDC) forces were applied, ranging from 0 to 5 N for the left common carotid artery (CCA) or 2–12 N for the left internal carotid artery (ICA). Six carotid elastography features, namely maximum and cumulated axial strains, maximum and cumulated shear strains, cumulated axial translation, and cumulated lateral translation were assessed with noninvasive vascular elastography (NIVE) on near and far walls of carotids. The carotid intima media thickness (IMT) and diameter were also measured. Results All elastography features on the near wall of both CCA and ICA decreased statistically significantly as the PDC force increased; this association was also observed for half of the features on the far wall. Three NIVE features at the lowest PDC force (out of 72 that were tested) were statistically significantly different than values at the SP force. Overall, NIVE showed some variance to probe compression with linear regression slopes revealing changes of 10.1%–45.6% in magnitude over the whole compression range on both walls. The maximum IMT for the ICA near wall, and carotid lumen diameters of both CCA and ICA were statistically significantly associated with PDC forces; these features underwent a decrease of 10.2%, 36.2%, and 17.6%, respectively, over the whole range of PDC force increase. Other IMT measurements were not statistically significantly associated with applied PDC forces. Conclusion These results suggest the need of technical guidelines for carotid strain elastography. Using the lowest probe compression while allowing a good B‐mode image quality is recommended to improve the robustness of NIVE measurements.
- 25 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (12) , 3788-3800
Parameterized Strain Estimation for Vascular Ultrasound Elastography With Sparse Representation
Ultrasound vascular strain imaging has shown its potential to interrogate the motion of the vessel wall induced by the cardiac pulsation for predicting plaque instability. In this study, a sparse model strain estimator (SMSE) is proposed to reconstruct a dense strain field at a high resolution, with no spatial derivatives, and a high computation efficiency. This sparse model utilizes the highly-compacted property of discrete cosine transform (DCT) coefficients, thereby allowing to parameterize displacement and strain fields with truncated DCT coefficients. The derivation of affine strain components (axial and lateral strains and shears) was reformulated into solving truncated DCT coefficients and then reconstructed with them. Moreover, an analytical solution was derived to reduce estimation time. With simulations, the SMSE reduced estimation errors by up to 50% compared with the state-of-the-art window-based Lagrangian speckle model estimator (LSME). The SMSE was also proven to be more robust than the LSME against global and local noise. For in vitro and in vivo tests, residual strains assessing cumulated errors with the SMSE were 2 to 3 times lower than with the LSME. Regarding computation efficiency, the processing time of the SMSE was reduced by 4 to 25 times compared with the LSME, according to simulations, in vitro and in vivo results. Finally, phantom studies demonstrated the enhanced spatial resolution of the proposed SMSE algorithm against LSME.
- 25 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (12) , 3788-3800
Parameterized Strain Estimation for Vascular Ultrasound Elastography With Sparse Representation
Ultrasound vascular strain imaging has shown its potential to interrogate the motion of the vessel wall induced by the cardiac pulsation for predicting plaque instability. In this study, a sparse model strain estimator (SMSE) is proposed to reconstruct a dense strain field at a high resolution, with no spatial derivatives, and a high computation efficiency. This sparse model utilizes the highly-compacted property of discrete cosine transform (DCT) coefficients, thereby allowing to parameterize displacement and strain fields with truncated DCT coefficients. The derivation of affine strain components (axial and lateral strains and shears) was reformulated into solving truncated DCT coefficients and then reconstructed with them. Moreover, an analytical solution was derived to reduce estimation time. With simulations, the SMSE reduced estimation errors by up to 50% compared with the state-of-the-art window-based Lagrangian speckle model estimator (LSME). The SMSE was also proven to be more robust than the LSME against global and local noise. For in vitro and in vivo tests, residual strains assessing cumulated errors with the SMSE were 2 to 3 times lower than with the LSME. Regarding computation efficiency, the processing time of the SMSE was reduced by 4 to 25 times compared with the LSME, according to simulations, in vitro and in vivo results. Finally, phantom studies demonstrated the enhanced spatial resolution of the proposed SMSE algorithm against LSME.
- 1 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095025
Atherosclerotic carotid bifurcation phantoms with stenotic soft inclusions for ultrasound flow and vessel wall elastography imaging
As the complexity of ultrasound signal processing algorithms increases, it becomes more difficult to demonstrate their added value and thus robust validation strategies are required. We propose a method of manufacturing ultrasonic vascular phantoms mimicking an atheromatous plaque in an internal carotid artery bifurcation for applications in flow imaging and elastography. During the fabrication process, a soft inclusion mimicking a stenotic lipid pool was embedded within the vascular wall. Mechanical testing measured Young’s moduli of the vascular wall and soft inclusion at 342 ± 25 kPa and 17 ± 3 kPa, respectively. B-mode, color Doppler, power Doppler, shear wave elastography, and strain elastography images of the different phantoms were produced to show the validity of the fabrication process. Because of their realistic geometries and mechanical properties, those phantoms may become advantageous for fluid-structure experimental modeling and validation of new ultrasound-based imaging technologies.
- 1 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095025
Atherosclerotic carotid bifurcation phantoms with stenotic soft inclusions for ultrasound flow and vessel wall elastography imaging
As the complexity of ultrasound signal processing algorithms increases, it becomes more difficult to demonstrate their added value and thus robust validation strategies are required. We propose a method of manufacturing ultrasonic vascular phantoms mimicking an atheromatous plaque in an internal carotid artery bifurcation for applications in flow imaging and elastography. During the fabrication process, a soft inclusion mimicking a stenotic lipid pool was embedded within the vascular wall. Mechanical testing measured Young’s moduli of the vascular wall and soft inclusion at 342 ± 25 kPa and 17 ± 3 kPa, respectively. B-mode, color Doppler, power Doppler, shear wave elastography, and strain elastography images of the different phantoms were produced to show the validity of the fabrication process. Because of their realistic geometries and mechanical properties, those phantoms may become advantageous for fluid-structure experimental modeling and validation of new ultrasound-based imaging technologies.
- 7 March 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (7) , 3854-3861
The value of non-invasive vascular elastography (NIVE) in detecting early vascular changes in overweight and obese children
Evaluate non-invasive vascular elastography (NIVE) in detecting vascular changes associated with obese children.
- 7 March 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (7) , 3854-3861
The value of non-invasive vascular elastography (NIVE) in detecting early vascular changes in overweight and obese children
Evaluate non-invasive vascular elastography (NIVE) in detecting vascular changes associated with obese children.