L. F. N. D. Carramate
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
L. F. N. D. Carramate has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Joao F. C. A. Veloso
University of Aveiro
19 shared publications - Carlos Davide Rocha Azevedo
Universidade de Aveiro
18 shared publications - Ana Luísa M. Silva
University of Aveiro
14 shared publications - Silvia De Francesco
Univ. de Aveiro (Portugal)
6 shared publications - P. M. Mendes Correia
University of Aveiro
5 shared publications - Joaquim Marques Ferreira dos Santos
University of Coimbra
4 shared publications
Latest Publications
- 1 November 2025
- Published by IATED Academy in ICERI Proceedings
- Vol. 1, 6988-6994
INNOVATING CLINICAL EDUCATION IN RADIOTHERAPY: EARLY RESULTS FROM A PRACTICE-INTEGRATED MODEL
- 1 November 2025
- Published by IATED Academy in ICERI Proceedings
- Vol. 1, 6988-6994
INNOVATING CLINICAL EDUCATION IN RADIOTHERAPY: EARLY RESULTS FROM A PRACTICE-INTEGRATED MODEL
- 4 April 2025
- Published by Taylor & Francis in The Imaging Science Journal
- Vol. 73 (6) , 786-801
Tomographic image reconstruction from projections using generative AI
- 4 April 2025
- Published by Taylor & Francis in The Imaging Science Journal
- Vol. 73 (6) , 786-801
Tomographic image reconstruction from projections using generative AI
- 1 November 2023
- Published by IATED Academy in ICERI Proceedings
- p. 2950-2955
ASSESSMENT OF PHYSICS IN MEDICAL IMAGING AND RADIOTHERAPY COURSE TRANSFORMATION FOR HEALTHCARE STUDENTS
- 1 November 2023
- Published by IATED Academy in ICERI Proceedings
- p. 2950-2955
ASSESSMENT OF PHYSICS IN MEDICAL IMAGING AND RADIOTHERAPY COURSE TRANSFORMATION FOR HEALTHCARE STUDENTS
- 1 November 2020
- Published by IATED Academy in ICERI Proceedings
- Vol. 1, 6336-6345
MEDICAL IMAGING AND RADIOTHERAPY EDUCATION DURING PANDEMIC EMERGENCY: IMPACT OF EMERGENCY REMOTE TEACHING
Information about the paper titled "MEDICAL IMAGING AND RADIOTHERAPY EDUCATION DURING PANDEMIC EMERGENCY: IMPACT OF EMERGENCY REMOTE TEACHING" at IATED Digital Library
- 1 November 2020
- Published by IATED Academy in ICERI Proceedings
- Vol. 1, 6336-6345
MEDICAL IMAGING AND RADIOTHERAPY EDUCATION DURING PANDEMIC EMERGENCY: IMPACT OF EMERGENCY REMOTE TEACHING
Information about the paper titled "MEDICAL IMAGING AND RADIOTHERAPY EDUCATION DURING PANDEMIC EMERGENCY: IMPACT OF EMERGENCY REMOTE TEACHING" at IATED Digital Library
- 1 June 2020
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 51 (2) , 235-240
Simulation of Image-Guided Intervention in Medical Imaging Education
- 1 June 2020
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 51 (2) , 235-240
Simulation of Image-Guided Intervention in Medical Imaging Education
- 1 November 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (11) , T11010
Monitoring the effect of gas purification of sealed MPGDs for X-ray imaging
The response of a sealed MicroPatterned Gaseous Detector (MPGD), with an enclosed gas purification system based on getters, was monitored for several weeks. An average of 2 discharges per day was registered during the monitoring period and the charge gain varied a maximum of 15% during the more stable period. The temperature of the getters was varied from 180oC to 250oC and no significant influence was registered in the detector response. A reactivation of the getters also did not affect the charge gain, which means that their gettering rate was at full efficiency before the reactivation. However, careful attention is paid to charge gain reduction for long times of operation which can denote a loss of getters efficiency along time and the need of getter reactivation. On the other hand, turning off the getters lead to a rapid decrease in the charge gain. This allows concluding that a purification system based on getters is really effective in removing gas impurities, being a crucial component of the detection system for a sealed gaseous detector.
- 1 November 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (11) , T11010
Monitoring the effect of gas purification of sealed MPGDs for X-ray imaging
The response of a sealed MicroPatterned Gaseous Detector (MPGD), with an enclosed gas purification system based on getters, was monitored for several weeks. An average of 2 discharges per day was registered during the monitoring period and the charge gain varied a maximum of 15% during the more stable period. The temperature of the getters was varied from 180oC to 250oC and no significant influence was registered in the detector response. A reactivation of the getters also did not affect the charge gain, which means that their gettering rate was at full efficiency before the reactivation. However, careful attention is paid to charge gain reduction for long times of operation which can denote a loss of getters efficiency along time and the need of getter reactivation. On the other hand, turning off the getters lead to a rapid decrease in the charge gain. This allows concluding that a purification system based on getters is really effective in removing gas impurities, being a crucial component of the detection system for a sealed gaseous detector.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Spectral X-Ray Imaging with a Sealed THCOBRA Detector
The performance of a Thick-COBRA based detector operating in sealed mode for X-ray imaging applications, as well as the exploration of its spectral capabilities for X-ray imaging is described. The presented detector was specifically developed for energy resolved X-ray imaging.The detector operates in pure Kr at 1 bar in sealed mode with an enclosed purification system. Its performance for X-ray imaging was evaluated, achieving a contrast of about 30% for a spatial frequency of 1 lp/mm. The detector uniformity varies with the energy range considered for evaluation with the detector location.Spectral X-ray transmission images of a clothespin and a screw allowed exploring the detector spectral capability to enhance image quality.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Spectral X-Ray Imaging with a Sealed THCOBRA Detector
The performance of a Thick-COBRA based detector operating in sealed mode for X-ray imaging applications, as well as the exploration of its spectral capabilities for X-ray imaging is described. The presented detector was specifically developed for energy resolved X-ray imaging.The detector operates in pure Kr at 1 bar in sealed mode with an enclosed purification system. Its performance for X-ray imaging was evaluated, achieving a contrast of about 30% for a spatial frequency of 1 lp/mm. The detector uniformity varies with the energy range considered for evaluation with the detector location.Spectral X-ray transmission images of a clothespin and a screw allowed exploring the detector spectral capability to enhance image quality.
- 1 October 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (10) , P10010
Spatial resolution properties of krypton-based mixtures using a 100 μm thick Gas Electron Multiplier
- 1 October 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (10) , P10010
Spatial resolution properties of krypton-based mixtures using a 100 μm thick Gas Electron Multiplier
- 1 December 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (12) , C12061
Gain characteristics of a 100 μm thick GEM in Krypton-CO2 mixtures
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 μm kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10×10 cm2 for the entire detection system. For each mixture, the effective gain and energy resolution were measured as a function of the electric field in the drift, transfer and induction regions. Using X-rays from a 55Fe radioactive source (5.9 keV), gains close to 104 and energy resolution of 22% (FWHM) were achieved in pure krypton under stable conditions, showing the potential of the experimental setup for the following imaging studies.
- 1 December 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (12) , C12061
Gain characteristics of a 100 μm thick GEM in Krypton-CO2 mixtures
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 μm kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10×10 cm2 for the entire detection system. For each mixture, the effective gain and energy resolution were measured as a function of the electric field in the drift, transfer and induction regions. Using X-rays from a 55Fe radioactive source (5.9 keV), gains close to 104 and energy resolution of 22% (FWHM) were achieved in pure krypton under stable conditions, showing the potential of the experimental setup for the following imaging studies.