Jose Javier Echevarría-Uraga
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jose Javier Echevarría-Uraga has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
- Ignacio García-Alonso
Department of Surgery and Radiology and Physical Medicine, University of the Basque Country UPV/EHU, Bilbao, Spain
6 shared publications - Begonya Fernandez-Ruanova
Área de Atención primaria en salud, prevención y enfermedades crónicas, Biocruces Bizkaia
5 shared publications - Borja Herrero de la Parte
Department of Surgery and Radiology and Physical Medicine, Faculty of Medicine and Nursing, University of the Basque Country UPV/EHU, Leioa, Spain
4 shared publications - Fernando Plazaola
Elektrizitate eta Elektronika Saila, Euskal Herriko Unibertsitatea UPV/EHU
3 shared publications J.L. Miguélez Vidales
3 shared publications- Nestor Etxebarria
Department of Analytical Chemistry, Faculty of Science and Technology, University of the Basque Country (EHU), Leioa, Spain, Spain
3 shared publications
Latest Publications
- Top Cited PapersOpen Access
Proposal of New Safety Limits for In Vivo Experiments of Magnetic Hyperthermia Antitumor Therapy
Background: Lately, major advances in crucial aspects of magnetic hyperthermia (MH) therapy have been made (nanoparticle synthesis, biosafety, etc.). However, there is one key point still lacking improvement: the magnetic field-frequency product (H × f = 4.85 × 108 Am−1s−1) proposed by Atkinson–Brezovich as a limit for MH therapies. Herein, we analyze both local and systemic physiological effects of overpassing this limit. Methods: Different combinations of field frequency and intensity exceeding the Atkinson–Brezovich limit (591–920 kHz, and 10.3–18 kA/m) have been applied for 21 min to WAG/RijHsd male rats, randomly distributed to groups of 12 animals; half of them were sacrificed after 12 h, and the others 10 days later. Biochemical serum analyses were performed to assess the general, hepatic, renal and/or pancreatic function. Results: MH raised liver temperature to 42.8 ± 0.4 °C. Although in five of the groups the exposure was relatively well tolerated, in the two of highest frequency (928 kHz) and intensity (18 kA/m), more than 50% of the animals died. A striking elevation in liver and systemic markers was observed after 12 h in the surviving animals, independently of the frequency and intensity used. Ten days later, liver markers were almost recovered in all of the animals. However, in those groups exposed to 591 kHz and 16 kA/m, and 700 kHz and 13.7 kA/m systemic markers remained altered. Conclusions: Exceeding the Atkinson–Brezovich limit up to 9.59 × 109 Am−1s−1 seems to be safe, though further research is needed to understand the impact of intensity and/or frequency on physiological conditions following MH.
Top Cited PapersOpen AccessProposal of New Safety Limits for In Vivo Experiments of Magnetic Hyperthermia Antitumor Therapy
Background: Lately, major advances in crucial aspects of magnetic hyperthermia (MH) therapy have been made (nanoparticle synthesis, biosafety, etc.). However, there is one key point still lacking improvement: the magnetic field-frequency product (H × f = 4.85 × 108 Am−1s−1) proposed by Atkinson–Brezovich as a limit for MH therapies. Herein, we analyze both local and systemic physiological effects of overpassing this limit. Methods: Different combinations of field frequency and intensity exceeding the Atkinson–Brezovich limit (591–920 kHz, and 10.3–18 kA/m) have been applied for 21 min to WAG/RijHsd male rats, randomly distributed to groups of 12 animals; half of them were sacrificed after 12 h, and the others 10 days later. Biochemical serum analyses were performed to assess the general, hepatic, renal and/or pancreatic function. Results: MH raised liver temperature to 42.8 ± 0.4 °C. Although in five of the groups the exposure was relatively well tolerated, in the two of highest frequency (928 kHz) and intensity (18 kA/m), more than 50% of the animals died. A striking elevation in liver and systemic markers was observed after 12 h in the surviving animals, independently of the frequency and intensity used. Ten days later, liver markers were almost recovered in all of the animals. However, in those groups exposed to 591 kHz and 16 kA/m, and 700 kHz and 13.7 kA/m systemic markers remained altered. Conclusions: Exceeding the Atkinson–Brezovich limit up to 9.59 × 109 Am−1s−1 seems to be safe, though further research is needed to understand the impact of intensity and/or frequency on physiological conditions following MH.
- 28 January 2022
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 28 (1) , 58-64
Complications and diagnostic accuracy of CT-guided 18G tru-cut versus end-cut percutaneous core needle biopsy of solitary solid lung nodules
Percutaneous biopsy has demonstrated high accuracy in diagnosis of lung nodules, but the technique is not innocuous and a yield decrease in lesions smaller than 20 mm has been reported. We carried out a prospective study to evaluate and compare the complications and efficacy of percutaneous core needle biopsy (CNB) of solitary solid lung nodules, which were performed with two types of automatic guns. 330 consecutive CT-guided CNB were included. Tru-cut or end-cut 18G devices were used alternatively. Nodules were categorized by their size: ≤10 mm, 11-20 mm and >20 mm. Incidence of complications such as pneumothorax or hemoptysis and factors influencing them (nodule size and depth within lung parenchyma) were evaluated. Diagnostic accuracy of CNB achieved in the three groups of nodules regarding the two different needles were calculated and statistically evaluated and compared. We performed 68 CNB in nodules ≤10 mm, 130 in 11-20 mm and 132 in >20 mm. Pneumothorax appeared in 24.2% of them, but only 5.7% required drainage. Hemoptysis was developed in 9.4% and abundant hemoptysis with hypoxemia was observed in only 4.2% of patients. Regarding appearance of complications between the two needle types, no significant differences were found. A higher risk of hemoptysis was observed in nodules ≤10 mm (OR = 3.87; 95% CI = 1.24-12.06, P = 0.019) and in those located deeper in pulmonary parenchyma (OR = 2.21; 95% CI = 1.04-4.69, P = 0.038). End-cut needles reached a diagnostic accuracy of 93.7%, 92.1% and 98.3%, in nodules sized ≤10 mm, 11-20 mm and >20 mm, respectively. Corresponding results for tru-cut were 84.7%, 88.5% and 92.1%. In spite of differences reaching up to 9% in smaller nodules, intra-group results were not significant. Both needles have similar complications rate. Despite not having observed statistically significant differences between the two types of needles, end-cut devices have demonstrated a higher diagnostic yield in the three groups of nodules and could be a more suitable option especially for CNB of nodules ≤10 mm.
- 28 January 2022
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 28 (1) , 58-64
Complications and diagnostic accuracy of CT-guided 18G tru-cut versus end-cut percutaneous core needle biopsy of solitary solid lung nodules
Percutaneous biopsy has demonstrated high accuracy in diagnosis of lung nodules, but the technique is not innocuous and a yield decrease in lesions smaller than 20 mm has been reported. We carried out a prospective study to evaluate and compare the complications and efficacy of percutaneous core needle biopsy (CNB) of solitary solid lung nodules, which were performed with two types of automatic guns. 330 consecutive CT-guided CNB were included. Tru-cut or end-cut 18G devices were used alternatively. Nodules were categorized by their size: ≤10 mm, 11-20 mm and >20 mm. Incidence of complications such as pneumothorax or hemoptysis and factors influencing them (nodule size and depth within lung parenchyma) were evaluated. Diagnostic accuracy of CNB achieved in the three groups of nodules regarding the two different needles were calculated and statistically evaluated and compared. We performed 68 CNB in nodules ≤10 mm, 130 in 11-20 mm and 132 in >20 mm. Pneumothorax appeared in 24.2% of them, but only 5.7% required drainage. Hemoptysis was developed in 9.4% and abundant hemoptysis with hypoxemia was observed in only 4.2% of patients. Regarding appearance of complications between the two needle types, no significant differences were found. A higher risk of hemoptysis was observed in nodules ≤10 mm (OR = 3.87; 95% CI = 1.24-12.06, P = 0.019) and in those located deeper in pulmonary parenchyma (OR = 2.21; 95% CI = 1.04-4.69, P = 0.038). End-cut needles reached a diagnostic accuracy of 93.7%, 92.1% and 98.3%, in nodules sized ≤10 mm, 11-20 mm and >20 mm, respectively. Corresponding results for tru-cut were 84.7%, 88.5% and 92.1%. In spite of differences reaching up to 9% in smaller nodules, intra-group results were not significant. Both needles have similar complications rate. Despite not having observed statistically significant differences between the two types of needles, end-cut devices have demonstrated a higher diagnostic yield in the three groups of nodules and could be a more suitable option especially for CNB of nodules ≤10 mm.
- Open Access
- 17 May 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (5) , 1318
Biochemical and Metabolomic Changes after Electromagnetic Hyperthermia Exposure to Treat Colorectal Cancer Liver Implants in Rats
Background: Hyperthermia (HT) therapy still remains relatively unknown, in terms of both its biological and therapeutic effects. This work aims to analyze the effects of exposure to HT, such as that required in anti-tumor magnetic hyperthermia therapies, using metabolomic and serum parameters routinely analyzed in clinical practice. Methods: WAG/RigHsd rats were assigned to the different experimental groups needed to emulate all of the procedures involved in the treatment of liver metastases by HT. Twelve hours or ten days after the electromagnetic HT (606 kHz and 14 kA/m during 21 min), blood samples were retrieved and liver samples were obtained. 1H-nuclear-magnetic-resonance spectroscopy (1H-NMR) was used to search for possible diagnostic biomarkers of HT effects on the rat liver tissue. All of the data obtained from the hydrophilic fraction of the tissues were analyzed and modeled using chemometric tools. Results: Hepatic enzyme levels were significantly increased in animals that underwent hyperthermia after 12 h, but 10 d later they could not be detected anymore. The metabolomic profile (main metabolic differences were found in phosphatidylcholine, taurine, glucose, lactate and pyruvate, among others) also showed that the therapy significantly altered metabolism in the liver within 12 h (with two different patterns); however, those changes reverted to a control-profile pattern after 10 days. Conclusions: Magnetic hyperthermia could be considered as a safe therapy to treat liver metastases, since it does not induce irreversible physiological changes after application.
- 17 May 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (5) , 1318
Open AccessBiochemical and Metabolomic Changes after Electromagnetic Hyperthermia Exposure to Treat Colorectal Cancer Liver Implants in Rats
Background: Hyperthermia (HT) therapy still remains relatively unknown, in terms of both its biological and therapeutic effects. This work aims to analyze the effects of exposure to HT, such as that required in anti-tumor magnetic hyperthermia therapies, using metabolomic and serum parameters routinely analyzed in clinical practice. Methods: WAG/RigHsd rats were assigned to the different experimental groups needed to emulate all of the procedures involved in the treatment of liver metastases by HT. Twelve hours or ten days after the electromagnetic HT (606 kHz and 14 kA/m during 21 min), blood samples were retrieved and liver samples were obtained. 1H-nuclear-magnetic-resonance spectroscopy (1H-NMR) was used to search for possible diagnostic biomarkers of HT effects on the rat liver tissue. All of the data obtained from the hydrophilic fraction of the tissues were analyzed and modeled using chemometric tools. Results: Hepatic enzyme levels were significantly increased in animals that underwent hyperthermia after 12 h, but 10 d later they could not be detected anymore. The metabolomic profile (main metabolic differences were found in phosphatidylcholine, taurine, glucose, lactate and pyruvate, among others) also showed that the therapy significantly altered metabolism in the liver within 12 h (with two different patterns); however, those changes reverted to a control-profile pattern after 10 days. Conclusions: Magnetic hyperthermia could be considered as a safe therapy to treat liver metastases, since it does not induce irreversible physiological changes after application.
- 17 December 2020
- Published by S. Karger AG in European Surgical Research
- Vol. 61 (4-5) , 136-142
Intra-Arterial Infusion of Magnetic Nanoparticle-Based Theragnostic Agent to Treat Colorectal Cancer Liver Implants in Rats
Introduction: Nowadays, surgical excision remains the gold standard to treat liver metastases of colorectal cancer (CRCLM). However, as more than 50% of patients are not eligible for surgery, other alternatives such as percutaneous or intravascular interventional therapies (thermal ablation, chemoembolization, or radioembolization), are quite relevant. Recently, the use of magnetic nanoparticles (MNPs) has been suggested as an adjuvant for these therapies, as they could increase their necrotising effect on the tumour while reducing doses and exposure times of thermal therapies. To investigate the potential curative effect of these compounds, animal models are needed, both for the development of experimental interventional procedures and for MNPs toxicity and distribution assessment. Herein, we describe both an experimental infusion procedure in CRCLM-bearing rats and analytical and histological methods to evaluate MNPs deposits in the tissue. Methods: Eighteen male WAG/RijHsd rats were subjected to intrahepatic injection of 250,000 colorectal cancer cells. Twenty-eight days later, half of the tumour-positive animals (n = 6) were administered with MNPs while the other half (n = 6) did not receive any injection and were used as control. Under microscope magnification, the splenic artery was carefully and completely dissected, and a catheter was inserted through the splenic artery to the common hepatic artery where 1 mL MNPs suspension was administered in 5 min; then STIR, DP*, and T2 MRI sequences were obtained (and signal intensity measured) and both tumour and liver tissue samples were collected for elemental and histological analyses. Conclusion: Our method for selective administration of MNPs is reproducible and well-tolerated and it fairly mimics the approach used in clinical practice when intravascular interventional therapies are applied.
- 17 December 2020
- Published by S. Karger AG in European Surgical Research
- Vol. 61 (4-5) , 136-142
Intra-Arterial Infusion of Magnetic Nanoparticle-Based Theragnostic Agent to Treat Colorectal Cancer Liver Implants in Rats
Introduction: Nowadays, surgical excision remains the gold standard to treat liver metastases of colorectal cancer (CRCLM). However, as more than 50% of patients are not eligible for surgery, other alternatives such as percutaneous or intravascular interventional therapies (thermal ablation, chemoembolization, or radioembolization), are quite relevant. Recently, the use of magnetic nanoparticles (MNPs) has been suggested as an adjuvant for these therapies, as they could increase their necrotising effect on the tumour while reducing doses and exposure times of thermal therapies. To investigate the potential curative effect of these compounds, animal models are needed, both for the development of experimental interventional procedures and for MNPs toxicity and distribution assessment. Herein, we describe both an experimental infusion procedure in CRCLM-bearing rats and analytical and histological methods to evaluate MNPs deposits in the tissue. Methods: Eighteen male WAG/RijHsd rats were subjected to intrahepatic injection of 250,000 colorectal cancer cells. Twenty-eight days later, half of the tumour-positive animals (n = 6) were administered with MNPs while the other half (n = 6) did not receive any injection and were used as control. Under microscope magnification, the splenic artery was carefully and completely dissected, and a catheter was inserted through the splenic artery to the common hepatic artery where 1 mL MNPs suspension was administered in 5 min; then STIR, DP*, and T2 MRI sequences were obtained (and signal intensity measured) and both tumour and liver tissue samples were collected for elemental and histological analyses. Conclusion: Our method for selective administration of MNPs is reproducible and well-tolerated and it fairly mimics the approach used in clinical practice when intravascular interventional therapies are applied.
- 2 June 2016
- Published by Wiley in Respirology
- Vol. 21 (6) , 1094-1099
Usefulness of an angioplasty balloon as selective bronchial blockade device after transbronchial cryobiopsy
Background and objective: Transbronchial cryobiopsy (TBCB) is a technique in which frozen samples of lung are obtained using a probe inserted through a bronchoscope. We performed a retrospective study to assess the performance of the TBCB procedure complemented by segmental bronchial blockade using an angioplasty balloon, in terms of diagnostic yield and safety in diffuse parenchymal lung disease (DPLD).Methods: Data from 100 patients with suspected DPLD (clinical and radiological findings), who underwent TBCB in our institution to establish a definitive diagnosis, were reviewed. In our institution, TBCB is monitored with fluoroscopy and performed under general anaesthesia by a multidisciplinary team (an anaesthesiologist, a pulmonologist and an interventional radiologist). In each patient, four samples were collected using a 2.4‐mm distal diameter cryoprobe. To control bleeding, the biopsied segmental bronchus was blocked with a 6‐mm diameter angioplasty balloon, inserted over a 0.035‐inch angled hydrophilic guidewire. After the cryoextraction, the balloon was inflated for 3 min intervals until bleeding stopped.Results: Overall, 98% of samples had diagnostic value. In 85% of cases, DPLD was confirmed, while in 7%, cancer was diagnosed. Complications were observed in 16% of the patients: 13 patients developed moderate haemorrhage, and 3 developed pneumothorax.Conclusion: Transbronchial cryobiopsy had a high diagnostic yield for DPLD. Performing the procedure under fluoroscopy guidance and using angioplasty balloon for selective bronchial blockade achieved a low rate of iatrogenic complications directly associated with the technique.
- 2 June 2016
- Published by Wiley in Respirology
- Vol. 21 (6) , 1094-1099
Usefulness of an angioplasty balloon as selective bronchial blockade device after transbronchial cryobiopsy
Background and objective: Transbronchial cryobiopsy (TBCB) is a technique in which frozen samples of lung are obtained using a probe inserted through a bronchoscope. We performed a retrospective study to assess the performance of the TBCB procedure complemented by segmental bronchial blockade using an angioplasty balloon, in terms of diagnostic yield and safety in diffuse parenchymal lung disease (DPLD).Methods: Data from 100 patients with suspected DPLD (clinical and radiological findings), who underwent TBCB in our institution to establish a definitive diagnosis, were reviewed. In our institution, TBCB is monitored with fluoroscopy and performed under general anaesthesia by a multidisciplinary team (an anaesthesiologist, a pulmonologist and an interventional radiologist). In each patient, four samples were collected using a 2.4‐mm distal diameter cryoprobe. To control bleeding, the biopsied segmental bronchus was blocked with a 6‐mm diameter angioplasty balloon, inserted over a 0.035‐inch angled hydrophilic guidewire. After the cryoextraction, the balloon was inflated for 3 min intervals until bleeding stopped.Results: Overall, 98% of samples had diagnostic value. In 85% of cases, DPLD was confirmed, while in 7%, cancer was diagnosed. Complications were observed in 16% of the patients: 13 patients developed moderate haemorrhage, and 3 developed pneumothorax.Conclusion: Transbronchial cryobiopsy had a high diagnostic yield for DPLD. Performing the procedure under fluoroscopy guidance and using angioplasty balloon for selective bronchial blockade achieved a low rate of iatrogenic complications directly associated with the technique.
- 1 October 2014
- Published by Elsevier in Diálisis y Trasplante
- Vol. 35 (4) , 163-168
Accesos venosos para hemodiálisis: abordaje yugular
- 1 October 2014
- Published by Elsevier in Diálisis y Trasplante
- Vol. 35 (4) , 163-168
Accesos venosos para hemodiálisis: abordaje yugular
- Open Access
- 7 September 2012
- Published by Wolters Kluwer Health in Hepatology
- Vol. 57 (2) , 505-514
Solute Carrier Family 2 Member 1 Is Involved in the Development of Nonalcoholic Fatty Liver Disease
Susceptibility to develop nonalcoholic fatty liver disease (NAFLD) has genetic bases, but the associated variants are uncertain. The aim of the present study was to identify genetic variants that could help to prognose and further understand the genetics and development of NAFLD. Allele frequencies of 3,072 single-nucleotide polymorphisms (SNPs) in 92 genes were characterized in 69 NAFLD patients and 217 healthy individuals. The markers that showed significant allele-frequency differences in the pilot groups were subsequently studied in 451 NAFLD patients and 304 healthy controls. Besides this, 4,414 type 2 diabetes mellitus (T2DM) cases and 4,567 controls were genotyped. Liver expression of the associated gene was measured and the effect of its potential role was studied by silencing the gene in vitro . Whole genome expression, oxidative stress (OS), and the consequences of oleic acid (OA)-enriched medium on lipid accumulation in si SLC2A1 -THLE2 cells were studied by gene-expression analysis, dihydroethidium staining, BODIPY, and quantification of intracellular triglyceride content, respectively. Several SNPs of SLC2A1 (solute carrier family 2 [facilitated glucose transporter] member 1) showed association with NAFLD, but not with T2DM, being the haplotype containing the minor allele of SLC2A1 sequence related to the susceptibility to develop NAFLD. Gene-expression analysis demonstrated a significant down-regulation of SLC2A1 in NAFLD livers. Enrichment functional analyses of transcriptome profiles drove us to demonstrate that in vitro silencing of SLC2A1 induces an increased OS activity and a higher lipid accumulation under OA treatment. Conclusions: Genetic variants of SLC2A1 are associated with NAFLD, and in vitro down-regulation of this gene promotes lipid accumulation. Moreover, the oxidative response detected in si SLC2A1 -THLE2 cells corroborated the antioxidant properties previously related to this gene and linked the most representative clinical characteristics of NAFLD patients: oxidative injury and increased lipid storage.
- 7 September 2012
- Published by Wolters Kluwer Health in Hepatology
- Vol. 57 (2) , 505-514
Open AccessSolute Carrier Family 2 Member 1 Is Involved in the Development of Nonalcoholic Fatty Liver Disease
Susceptibility to develop nonalcoholic fatty liver disease (NAFLD) has genetic bases, but the associated variants are uncertain. The aim of the present study was to identify genetic variants that could help to prognose and further understand the genetics and development of NAFLD. Allele frequencies of 3,072 single-nucleotide polymorphisms (SNPs) in 92 genes were characterized in 69 NAFLD patients and 217 healthy individuals. The markers that showed significant allele-frequency differences in the pilot groups were subsequently studied in 451 NAFLD patients and 304 healthy controls. Besides this, 4,414 type 2 diabetes mellitus (T2DM) cases and 4,567 controls were genotyped. Liver expression of the associated gene was measured and the effect of its potential role was studied by silencing the gene in vitro . Whole genome expression, oxidative stress (OS), and the consequences of oleic acid (OA)-enriched medium on lipid accumulation in si SLC2A1 -THLE2 cells were studied by gene-expression analysis, dihydroethidium staining, BODIPY, and quantification of intracellular triglyceride content, respectively. Several SNPs of SLC2A1 (solute carrier family 2 [facilitated glucose transporter] member 1) showed association with NAFLD, but not with T2DM, being the haplotype containing the minor allele of SLC2A1 sequence related to the susceptibility to develop NAFLD. Gene-expression analysis demonstrated a significant down-regulation of SLC2A1 in NAFLD livers. Enrichment functional analyses of transcriptome profiles drove us to demonstrate that in vitro silencing of SLC2A1 induces an increased OS activity and a higher lipid accumulation under OA treatment. Conclusions: Genetic variants of SLC2A1 are associated with NAFLD, and in vitro down-regulation of this gene promotes lipid accumulation. Moreover, the oxidative response detected in si SLC2A1 -THLE2 cells corroborated the antioxidant properties previously related to this gene and linked the most representative clinical characteristics of NAFLD patients: oxidative injury and increased lipid storage.
- Open Access
- 1 May 2012
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 7, 2399-2410
Study of the intra-arterial distribution of Fe3O4 nanoparticles in a model of colorectal neoplasm induced in rat liver by MRI and spectrometry
Purpose: To evaluate, in an experimental model, the reliability of MRI for determining whether a higher iron concentration was obtained in tumor tissue than in normal liver parenchyma after intra-arterial administration of Fe3O4 lipophilic nanoparticles. Materials and methods: WAG/RijCrl rats were inoculated in the left hepatic lobe with 25,000 syngeneic CC-531 colon adenocarcinoma cells, after which they were randomized into two groups: control (CG) and infused (IG). After confirming tumor induction, the IG rats received intra-arterial suspensions of Fe3O4 nanoparticles (2.6 mg) in Lipiodol® (0.15 mL). To calculate the iron concentration, [Fe], in the tumor and liver tissues of both groups of rats, measurements of signal intensity from the tumors, healthy liver tissue, and paravertebral muscles were made on a 1.5T MRI system in gradient-echo DP* and T2*-weighted sequences. In addition, samples were collected to quantify the [Fe] by inductively coupled plasma-mass spectrometry (ICP-MS), as well as for histological analysis. Statistical analysis was performed with non-parametric tests, and Bland–Altman plots were produced; P values -1 and 5.9 µmol • g-1, respectively, in the tumors, and 19.0 µmol • g-1 and 11.7 µmol • g-1, respectively, in the hepatic tissue. In the IG rats (n = 19), the values obtained by MRI and ICP-MS were 148.9 µmol • g-1 and 9.4 µmol • g-1, respectively, in the tumors, and 115.3 µmol • g-1 and 11.6 µmol • g-1, respectively, in the healthy liver tissue. The IG results revealed a clear disagreement between MRI and ICP-MS. In the comparative analysis between the groups regarding the [Fe] values obtained by ICP-MS, significant differences were found for the tumor samples (P < 0.001), but not for the hepatic tissue (P = 0.92). Under microscopy, scattered intravascular deposits of nanoparticles were observed, especially in the tumors. Conclusion: ICP-MS demonstrated significant uptake of exogenous iron in tumor tissue. MRI was useful for quantifying the [Fe] in the different tissues in the CG animals, but not in the IG animals. Although the irregular distribution of nanoparticles caused an important bias in the measurements obtained by MRI, the relative increase in iron content inside the tumor was suggested.
- 1 May 2012
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 7, 2399-2410
Open AccessStudy of the intra-arterial distribution of Fe3O4 nanoparticles in a model of colorectal neoplasm induced in rat liver by MRI and spectrometry
Purpose: To evaluate, in an experimental model, the reliability of MRI for determining whether a higher iron concentration was obtained in tumor tissue than in normal liver parenchyma after intra-arterial administration of Fe3O4 lipophilic nanoparticles. Materials and methods: WAG/RijCrl rats were inoculated in the left hepatic lobe with 25,000 syngeneic CC-531 colon adenocarcinoma cells, after which they were randomized into two groups: control (CG) and infused (IG). After confirming tumor induction, the IG rats received intra-arterial suspensions of Fe3O4 nanoparticles (2.6 mg) in Lipiodol® (0.15 mL). To calculate the iron concentration, [Fe], in the tumor and liver tissues of both groups of rats, measurements of signal intensity from the tumors, healthy liver tissue, and paravertebral muscles were made on a 1.5T MRI system in gradient-echo DP* and T2*-weighted sequences. In addition, samples were collected to quantify the [Fe] by inductively coupled plasma-mass spectrometry (ICP-MS), as well as for histological analysis. Statistical analysis was performed with non-parametric tests, and Bland–Altman plots were produced; P values -1 and 5.9 µmol • g-1, respectively, in the tumors, and 19.0 µmol • g-1 and 11.7 µmol • g-1, respectively, in the hepatic tissue. In the IG rats (n = 19), the values obtained by MRI and ICP-MS were 148.9 µmol • g-1 and 9.4 µmol • g-1, respectively, in the tumors, and 115.3 µmol • g-1 and 11.6 µmol • g-1, respectively, in the healthy liver tissue. The IG results revealed a clear disagreement between MRI and ICP-MS. In the comparative analysis between the groups regarding the [Fe] values obtained by ICP-MS, significant differences were found for the tumor samples (P < 0.001), but not for the hepatic tissue (P = 0.92). Under microscopy, scattered intravascular deposits of nanoparticles were observed, especially in the tumors. Conclusion: ICP-MS demonstrated significant uptake of exogenous iron in tumor tissue. MRI was useful for quantifying the [Fe] in the different tissues in the CG animals, but not in the IG animals. Although the irregular distribution of nanoparticles caused an important bias in the measurements obtained by MRI, the relative increase in iron content inside the tumor was suggested.
- 1 October 2011
- Published by Academia de Ciencias Médicas de Bilbao in Gaceta Médica de Bilbao
- Vol. 108 (4) , 123-126
Embolización de malformación arteriovenosa pulmonar con Amplatzer®. A propósito de un caso
- 1 October 2011
- Published by Academia de Ciencias Médicas de Bilbao in Gaceta Médica de Bilbao
- Vol. 108 (4) , 123-126
Embolización de malformación arteriovenosa pulmonar con Amplatzer®. A propósito de un caso