MPMayank Panwar

Mayank Panwar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mayank Panwar has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Short-Term Forecasting of Thermostatic and Residential Loads Using Long Short-Term Memory Recurrent Neural Networks

    by Bang Nguyen, Mayank Panwar, Rob Hovsapian, Yashodhan Agalgaonkar

    Internet of Things (IoT) devices in smart grids enable intelligent energy management for grid managers and personalized energy services for consumers. Investigating a smart grid with IoT devices requires a simulation framework with IoT devices modeling. However, there lack comprehensive study on the modeling of IoT devices in smart grids. This paper investigates the IoT device modeling of a thermostatic load and implements the recurrent neural networks model for short-term load forecasting in this IoT-based thermostatic load. The recurrent neural network structure is leveraged to build a load forecasting model on temporal correlation. The temporal recurrent neural network layers including long short-term memory cells are employed to learn the data from both the simulation platform and New South Wales residential datasets. The simulation results are provided for demonstration.

  • Open Access

    1-D Convolutional Graph Convolutional Networks for Fault Detection in Distributed Energy Systems

    by Bang L. H. Nguyen, Tuyen Vu, Thai-Thanh Nguyen, Mayank Panwar, Rob Hovsapian

    This paper presents a 1-D convolutional graph neural network for fault detection in microgrids. The combination of 1-D convolutional neural networks (1D-CNN) and graph convolutional networks (GCN) helps extract both spatial-temporal correlations from the voltage measurements in microgrids. The fault detection scheme includes fault event detection, fault type and phase classification, and fault location. There are five neural network model training to handle these tasks. Transfer learning and fine-tuning are applied to reduce training efforts. The combined recurrent graph convolutional neural networks (1D-CGCN) is compared with the traditional ANN structure on the Potsdam 13-bus microgrid dataset. The achievable accuracy of 99.27%, 98.1%, 98.75%, and 95.6% for fault detection, fault type classification, fault phase identification, and fault location respectively.

  • Open Access

    Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

    by Bang L. H. Nguyen, Mayank Panwar, Rob Hovsapian, Yashodhan Agalgaokar, Tuyen Vu

    This paper presents the operation modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is discussed. The case studies and real-time simulation results are provided using Typhoon HIL to back the theoretical investigation.


  • Open Access

    Integrated Multiport Back-to-Back Power Converter for Type-4 Wind Turbine Generator with Hybrid Energy Storage System

    by Bang Le-Huy Nguyen, Thai-Thanh Nguyen, Van-Long Pham, Tuyen Vu, Mayank Panwar, Rob Hovsapian

    This paper proposes a novel integrated multiport bidirectional back-to-back power converter for a type-4 wind turbine that accommodates a battery and supercapacitor for energy storage. The circuit topology reduces 4 switches compared to the traditional configuration. Moreover, owing to the dual-buck structure embedded in the phase leg, the circuitry has no short-circuit path, therefore it withstands short-circuited events for a much longer time than the normal phase-leg and prevents the reverse current in turn-off recovery. The use of a hybrid energy storage system with battery and supercapacitor helps smooth out the power output under wind gusts and stabilizes the DC-link voltage under grid fault conditions. The case studies are carried out with a 1.5 MW wind turbine system. Simulation results are provided for the theoretical validation.

  • Open Access

    Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

    by Rob Hovsapian, Julian D. Osorio, Mayank Panwar, Chryssostomos Chryssostomidis, Juan C. Ordonez

    In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.


  • Leveraging National Laboratory Assets to Address Stability Challenges due to Declining Grid Inertia Using Geographically Distributed Electrical–Thermal Co-Emulation

    by R. Hovsapian, M. Panwar, J. D. Osorio, M. Mohanpurkar, D. J. Maloney

    Due to increased penetration of low-inertia resources into the electric grid, challenges are increasing for maintaining wide-area system stability. Grid stability assessment requires a faithful representation of the multiple-physics interaction at the system level, and timescales of interaction varying in orders of magnitude, from microseconds to seconds to several minutes. Along with the simulation-based techniques, hardware-in-the-loop (HIL), controller HIL, and power HIL techniques have been developed to better understand the emergent behavior of the system with emerging technologies. US National Laboratories have played a vital role in research and development to understand the behavior of individual technologies and devices integrated to the electric grid. Each national laboratory forwards a technological and strategic initiative tied core and enabling capabilities. Due to strategic, efficiency, and economic reasons, not all the labs have assets to conduct research on all technologies concomitantly, so it becomes crucial to integrate the labs across geographies to understand the interplay of different technologies together at the system level. This approach avoids duplication of the assets at different lab facilities and helps understand the integrated system behavior of various technologies representative of actual grid conditions by connecting multiple national labs. This paper talks about techniques of connecting three national laboratories to enable co-emulation of electrical–mechanical–thermal characteristics of devices and systems. Such an approach can be used to understand the dynamic and transient interaction of multi-physics in a system level, at-scale emulation using real-time simulation tools and techniques.


  • Open Access

    A Performance Metric for Co-optimization of Day-Ahead Dispatch and Reserves in Electric Microgrids

    by Mayank Panwar, Rob Hovsapian, Robin Roche, Sid Suryanarayanan

    We present a new performance metric for co-optimization of dispatch and reserves in microgrids. A metric based on NERC criteria is used for each asset to quantity its reliability-based value. A system level metric is obtained through the individual performance metrics, dispatched capacity, and net dispatchable capacity available as reserve. Simulations are performed on a notional microgrid with a dispatchable and a non-dispatchable distributed energy resource to demonstrate the calculation of the metric.

  • Empirical study of simulation fidelity in geographically distributed real-time simulations

    by Marija Stevic, Mayank Panwar, Manish Mohanpurkar, Rob Hovsapian, Antonello Monti

    Interconnection of digital real-time simulators over wide-area communication networks is an innovative approach to extend local real-time simulation capabilities to enable large-scale simulations. Furthermore, it allows the integration of geographically distributed assets as Power Hardware-in-the-Loop and Controller Hardware-in-the-Loop, thus providing a flexible framework for performing unique research experiments. In most cases, it is not possible to perform large scale real-time simulations and comprehensive experiments locally due to lack of simulation capacity and unavailability of unique assets. Main challenge associated with geographically distributed real-time simulation is to ensure simulation fidelity of the same degree as in the case when the entire simulation is performed at the same location. Simulation fidelity in geographically distributed real-time simulation is investigated and an empirical characterization is provided in this paper. Fidelity degradation caused by different values of time delay and sending rate of data exchange between two digital real-time simulators is presented. Two methods for representation of interface quantities in co-simulation interface algorithms are considered for performing simulations. The first method is based on representation of interface quantities as root mean square of magnitude, frequency, and phase angle of the current and voltage waveforms. The second method utilizes representation of interface quantities in form of time-varying Fourier coefficients, known as dynamic phasors. The empirical study is performed for transmission-distribution co-simulation using two racks of Real-Time Digital Simulator (RTDS®).


  • Open Access

    Geographically distributed real-time digital simulations using linear prediction

    by Ren Liu, Manish Mohanpurkar, Mayank Panwar, Rob Hovsapian, Anurag Srivastava, Siddharth Suryanarayanan