LSLukasz Antoni Sterczewski

Lukasz Antoni Sterczewski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lukasz Antoni Sterczewski has a total of 310 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    GHz-bandwidth InAs/InAsSbP barrier infrared detectors for the 3.0–3.7 μ m spectral region operating at room temperature

    by Grzegorz Gomółka, Krzysztof Kłos, Jarosław Pawluczyk, Maciej Kowalczyk, Piotr Martyniuk, Łukasz A. Sterczewski

    The demand for fast mid-wave infrared photodetectors is fueled by high-rate free-space optical communication and optical frequency comb spectroscopy. To date, only a few multi-GHz photodetectors have shown sensitive room-temperature operation in the 3.0–3.7 μm band, yet their commercial availability remains scarce. In this work, we present the remarkable response speed of an InAs/InAsSbP p-Bp-i-n barrier detector based on a p-InAsSbP/n-InAs heterostructure—a technological platform typically not associated with high-frequency operation. A weakly reverse-biased photodiode with a diameter of 121 μm achieves a −3 dB electrical bandwidth of 2.4 GHz and −20 dB bandwidth of 8.0 GHz. This is the best result in this class of mid-infrared photodetectors confirmed optically. High signal-to-noise photodetection is also demonstrated at frequencies exceeding 19 GHz. The relatively simple device structure (devoid of cascaded structure or type-II superlattice) was realized on the mature InAs material platform, which opens new perspectives for accessible, sensitive, multi-GHz photodetectors for the 3.0–3.7 μm spectral region.

  • Microwave noise downconversion in interband cascade laser frequency combs

    by Grzegorz Gomolka, Florian Pilat, Benedikt Schwarz, Chul Soo Kim, Mijin Kim, Chadwick Canedy, Igor Vurgaftman, Jerry Meyer, Lukasz Sterczewski

    Chip-scale semiconductor laser frequency combs offer remarkable prospects for compact and power-efficient optical sensors. For the laser to be suitable for typical comb applications, its degree of coherence must first be assessed from a microwave self-mixing signal. Unfortunately, such measurements require scarcely available high-speed photodetectors with multi-GHz bandwidths and radio-frequency electronics. However, in this work, we demonstrate a simplified approach to comb coherence assessment for interband cascade lasers based on a relationship between easily-accessible MHz-frequency (baseband) noise and the multi-GHz-frequency intermode beat note. The downconversion of microwave noise to near-DC frequencies is found to originate intrinsically from the laser, which simultaneously acts as a frequency mixer due to electrical nonlinearities and a phase-to-amplitude noise converter due to the linewidth enhancement factor. Correlation between the electrical signals is explored in both frequency and time domains. Since this phenomenon is present in interband cascade lasers, and potentially in other classes of semiconductor lasers, it creates an opportunity for frequency comb characterization, which may be particularly valuable in wavelength regions where fast photodetectors have limited availability.

  • Incoherent Fourier Transform Spectroscopy with Room-Temperature Coverage from NIR To THz

    by Jakub Mnich, Grzegorz Gomolka, Marco Schossig, Jaroslaw Sotor, Lukasz Sterczewski

    Despite the broadband nature of thermal light sources, optical spectroscopy over multiple spectral bands simultaneously remains challenging. Here, we demonstrate a practical Fourier transform infrared spectrometer (FTIR) that achieves room-temperature spectral coverage from 1 to 50 µm (300–6 THz) in seconds using a single set of optics, with the long wave cutoff extendable to 90 µm (3.3 THz) and the short wave to the ultraviolet (0.39 µm). The interferometer employs a diamond plate beam splitter and a windowless lithium tantalate (LTO) detector to probe the spectrum of combined incoherent sources operating at different temperatures. Applications of the instrument in modern chemometry, material science, and medicine are envisioned.

  • Open Access

    Pulse duration retrieval using a commercial laser diode with a monitor photodiode

    by Adrian F. Chlebowski, Lukasz A. Sterczewski, Jaroslaw Sotor

    Semiconductor lasers merge coherent light emission with photodetection and, owing to third-order nonlinearities in their active region, function as sensitive room-temperature two-photon absorption detectors. Here, we leverage these capabilities offered by a commercially available InGaAsP semiconductor laser diode with an integrated InGaAs monitor photodiode to measure the duration of femtosecond pulses at telecom wavelengths. The nonlinear and linear signals obtained from both detectors enable the retrieval of pulse duration with femtosecond accuracy without moving parts. This capability is demonstrated down to 2 µW average optical power for a 250 MHz repetition rate laser.


  • Open Access

    Infrared photonics for healthcare: A roadmap for proactive and predictive health management

    by Borislav Hinkov, Johannes Kunsch, Werner Mäntele, Lukasz Sterczewski, Ángel Sánchez-Illana, Jaume Béjar-Grimalt, Víctor Navarro-Esteve, David Perez-Guaita, Alexander Mittelstädt, Philippa Clark, et al.

    The field of infrared (IR) photonics is currently undergoing remarkable progress, moving rapidly towards practical sensing applications demanded by medical therapy and diagnostics (theranostics). The Developments can be divided into three main categories: (i) novel devices and measurement concepts including advanced updates of classical approaches that push medical sensing into the spotlight; (ii) new demonstrations of photonic integrated circuit (PIC-)based IR devices enabling highly miniaturized sensors for point-of-care application as well as medical and wellness wearables; and (iii) technologically-mature IR demonstrators that enable first medical sensing and treatment applications. This roadmap paper provides a consolidated overview of this highly dynamic and interdisciplinary research field with a focus on the major roadblocks that limit the widespread adoption of IR photonics in large-scale medical diagnostics. Special attention is given to the ambivalence between the molecular-level spectroscopic interpretation and a broader health-state assessment, highlighting the need for a common framework. Additionally, the paper discusses the critical importance of unified measurement standards, calibration protocols, and medical certification processes to ensure the validity of experimental results, reproducibility, and clinical trust, particularly when novel experimental techniques and AI algorithms are involved. Perspectives from major past and current contributors to application-oriented IR photonics will be provided.

  • Open Access

    Midinfrared Semiconductor Photonics – A Roadmap

    by Jerry Meyer, Igor Vurgaftman, Shuiqing Yu, Rui Yang, Aaron Andrews, Benedikt Schwarz, Gottfried Strasser, Manijeh Razeghi, Leon Shterengas, Gela Kipshidze, et al.

    Semiconductor photonic devices operating in the midwave infrared (mid-IR, which we roughly define here as wavelengths spanning 3 to 14 µm) uniquely address a wide range of current practical needs. These include chemical sensing, environmental monitoring, industrial process control, medical diagnostics, thermal imaging, LIDAR, free space optical communication, and security monitoring. However, mid-IR device technologies are currently still works in progress that are generally much less mature than their near infrared and visible counterparts. Not only are most of the relevant materials more difficult to grow and process, but attainment of the desired optical device performance is often fundamentally more challenging. This Roadmap will review the leading applications for mid-IR optoelectronics, summarize the status and deficiencies of current device technologies, and then suggest possible roadmaps for improving and maturing the performance, manufacturability, and cost of each device type so the critical needs that are uniquely addressed by mid-IR photonics can be satisfied.

  • Open Access

    Midinfrared Semiconductor Photonics – A Roadmap

    by Jerry Meyer, Igor Vurgaftman, Shuiqing Yu, Rui Yang, Aaron Andrews, Benedikt Schwarz, Gottfried Strasser, Manijeh Razeghi, Leon Shterengas, Gela Kipshidze, et al.

    Semiconductor photonic devices operating in the midwave infrared (mid-IR, which we roughly define here as wavelengths spanning 3 to 14 µm) uniquely address a wide range of current practical needs. These include chemical sensing, environmental monitoring, industrial process control, medical diagnostics, thermal imaging, LIDAR, free space optical communication, and security monitoring. However, mid-IR device technologies are currently still works in progress that are generally much less mature than their near infrared and visible counterparts. Not only are most of the relevant materials more difficult to grow and process, but attainment of the desired optical device performance is often fundamentally more challenging. This Roadmap will review the leading applications for mid-IR optoelectronics, summarize the status and deficiencies of current device technologies, and then suggest possible roadmaps for improving and maturing the performance, manufacturability, and cost of each device type so the critical needs that are uniquely addressed by mid-IR photonics can be satisfied.

  • Open Access

    Midinfrared Semiconductor Photonics - A Roadmap

    by J. R. Meyer, I. Vurgaftman, S. -Q. Yu, R. Q. Yang, A. M. Andrews, G. Strasser, B. Schwarz, M. Razeghi, L. Shterengas, G. Kipshidze, et al.

    Semiconductor photonic devices operating in the midwave infrared (mid-IR, which we roughly define here as wavelengths spanning 3 to 14 microns) uniquely address a wide range of current practical needs. These include chemical sensing, environmental monitoring, industrial process control, medical diagnostics, thermal imaging, LIDAR, free space optical communication, and security monitoring. However, mid-IR device technologies are currently still works in progress that are generally much less mature than their near infrared and visible counterparts. Not only are most of the relevant materials more difficult to grow and process, but attainment of the desired optical device performance is often fundamentally more challenging. This Roadmap will review the leading applications for mid-IR optoelectronics, summarize the status and deficiencies of current device technologies, and then suggest possible roadmaps for improving and maturing the performance, manufacturability, and cost of each device type so the critical needs that are uniquely addressed by mid-IR photonics can be satisfied.


  • Open Access

    Sensitive and accurate femtosecond pulse characterization via two-photon absorption in Fabry-Pérot laser diodes

    by Adrian F. Chlebowski, Jakub Mnich, Lukasz A. Sterczewski, Jaroslaw Z. Sotor


  • High-precision absolute distance measurement by cascaded synthetic wavelength interferometry using a single electro-optic frequency comb

    by Runmin Li, Haochen Tian, Yang Liu, Dengfeng Dong, Lukasz A. Sterczewski, Weihu Zhou

    We demonstrate high-precision absolute distance measurement through cascaded synthetic wavelength interferometry (SWI) based on a single GHz-rate electro-optic frequency comb (EO comb). For this purpose, 3 of its discrete comb modes are selectively filtered by cascaded dense wavelength division multiplexers to serve as phase-linked continuous-wave (CW) lasers with relative frequency stability inherited from the microwave frequency reference. We vary the frequencies of these comb modes to generate a series of synthetic wavelengths by periodically switching the EO comb repetition rate. This allows us to obtain a maximum non-ambiguity range (NAR) of ∼3.74 m accompanied by the instrument’s ± 4 µm precision validated by a commercial HeNe interferometer. In addition to static targets, a velocity measurement with < ±15 µm/s residual compared to the HeNe interferometer is also shown. Our simple and robust technique for high-precision absolute distance and velocity measurement is well-suited for many industry-relevant problems requiring the combination of micrometer precision with a meter-scale NAR.