Mohamed Adhnan Thaha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohamed Adhnan Thaha has a total of 275 co-authors. Here are the top co-authors by number of shared publications:
- Robert James Campbell Steele
Department of Surgery, Population Health and Genomics, School of Medicine, University of Dundee, Ninewells Hospital, Dundee, Scotland, UK
7 shared publications - Alexander Hotouras
Academic Surgical Unit, Centre for Digestive Diseases, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University London, Whitechapel, London, UK
5 shared publications C. L. H. Chan
National Centre for Bowel Research and Surgical Innovation, London, UK
4 shared publicationsRobert Jc Steele
4 shared publicationsShafi Ahmed
National Centre for Bowel Research and Surgical Innovation, Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK
4 shared publications- Andrew Silver
Centre for Genomics and Child Health, Colorectal Cancer Genetics Group
3 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Springer Nature in Communications Engineering
A handheld tool for Young’s modulus characterization of soft materials: towards point-of-care tissue assessment
Palpation is a rapid and widely used physical examination technique for assessing tissue characteristics and guiding decisions about further imaging procedures. However, its effectiveness depends heavily on clinician experience, making standardized interpretation difficult. This paper presents SensoPal, a portable palpation-based system for quantitative non-invasive tissue stiffness assessment through measurement of the temporal and spatial Young’s modulus of soft materials. SensoPal integrates a handheld device with a miniature load cell and magnetometer, alongside a low-cost camera for position tracking, enabling the generation of spatial stiffness maps. User studies demonstrated Young’s modulus measurement accuracy of approximately ~ 87% (±4%) and repeatability of approximately ~ 86% (±4%). In localization tasks with flat silicone phantoms containing rigid nodules, stiffness maps identified deep-seated nodules undetectable through touch alone. Experiments on curved biofidelic phantoms with soft nodules demonstrated the system’s ability to capture spatial stiffness variations under realistic low-contrast conditions. SensoPal also distinguished compliant nodules embedded beyond depths of 8 mm, where manual detection became increasingly difficult. These findings establish SensoPal as a reliable, low-cost platform for quantitative tissue characterization in point-of-care diagnostics, telemedicine, and patient self-assessment.
- 5 November 2026
- Published by Springer Nature in Communications Engineering
Open AccessA handheld tool for Young’s modulus characterization of soft materials: towards point-of-care tissue assessment
Palpation is a rapid and widely used physical examination technique for assessing tissue characteristics and guiding decisions about further imaging procedures. However, its effectiveness depends heavily on clinician experience, making standardized interpretation difficult. This paper presents SensoPal, a portable palpation-based system for quantitative non-invasive tissue stiffness assessment through measurement of the temporal and spatial Young’s modulus of soft materials. SensoPal integrates a handheld device with a miniature load cell and magnetometer, alongside a low-cost camera for position tracking, enabling the generation of spatial stiffness maps. User studies demonstrated Young’s modulus measurement accuracy of approximately ~ 87% (±4%) and repeatability of approximately ~ 86% (±4%). In localization tasks with flat silicone phantoms containing rigid nodules, stiffness maps identified deep-seated nodules undetectable through touch alone. Experiments on curved biofidelic phantoms with soft nodules demonstrated the system’s ability to capture spatial stiffness variations under realistic low-contrast conditions. SensoPal also distinguished compliant nodules embedded beyond depths of 8 mm, where manual detection became increasingly difficult. These findings establish SensoPal as a reliable, low-cost platform for quantitative tissue characterization in point-of-care diagnostics, telemedicine, and patient self-assessment.
- Open Access
- 25 September 2026
- Published by SAGE Publications in Biomarker Insights
- Vol. 21
Unlocking Colorectal Cancer Diagnostics With Circulating Progastrin (hPG80): A Scoping Review
Colorectal cancer (CRC) represents a significant global health concern, ranking as the third most diagnosed cancer and the second leading cause of cancer deaths in the UK. Although population-based bowel cancer screening programs (BCSP) facilitate early diagnosis, uptake remains variable. Blood-based biomarkers, such as human progastrin 80 (hPG80), offer a patient-friendly approach to enhance screening compliance and clinical management. This scoping review, conducted according to PRISMA-ScR guidelines and registered in PROSPERO (CRD420250654595), searched Ovid Medline/PubMed, Ovid Embase, and Cochrane databases from January 1990 to January 2025. Studies assessing plasma hPG80 as a CRC biomarker were included, while reviews, in vitro studies, and animal models were excluded. Quality assessment was performed using the Newcastle-Ottawa Scale, and findings were synthesized narratively. Five articles encompassing 2,692 participants met the inclusion criteria. The included studies consistently demonstrated significant overexpression of hPG80 in CRC patients compared to non-cancer controls, with an increased median progastrin concentration in the CRC group (27.5 pmol/L) compared to patients with polyps or normal controls. Furthermore, hPG80 levels decreased significantly post-surgery (from 272.3 ± 12.0 pmol/L to 161.3 ± 11.0 pmol/L), reflecting its sensitivity to tumor burden and potential for treatment monitoring. Methodologically, literature has shifted from early radioimmunoassays to safer, cost-effective enzyme-linked immunosorbent assays (ELISA). A meta-analysis was not feasible due to variations in analytes, assays, populations, thresholds, and a lack of CRC-specific sensitivity, specificity, or area under the curve data. This review highlights hPG80’s promise as a reliable, reproducible blood-based biomarker for CRC integration into BCSPs and symptomatic pathways. However, optimal thresholds, stage-specific correlation, molecular subtypes, and cost-effectiveness remain unanswered. The ongoing MOTION trial (NCT07035691) is currently evaluating hPG80’s performance within UK symptomatic suspected colorectal cancer referral pathways.
- 25 September 2026
- Published by SAGE Publications in Biomarker Insights
- Vol. 21
Open AccessUnlocking Colorectal Cancer Diagnostics With Circulating Progastrin (hPG80): A Scoping Review
Colorectal cancer (CRC) represents a significant global health concern, ranking as the third most diagnosed cancer and the second leading cause of cancer deaths in the UK. Although population-based bowel cancer screening programs (BCSP) facilitate early diagnosis, uptake remains variable. Blood-based biomarkers, such as human progastrin 80 (hPG80), offer a patient-friendly approach to enhance screening compliance and clinical management. This scoping review, conducted according to PRISMA-ScR guidelines and registered in PROSPERO (CRD420250654595), searched Ovid Medline/PubMed, Ovid Embase, and Cochrane databases from January 1990 to January 2025. Studies assessing plasma hPG80 as a CRC biomarker were included, while reviews, in vitro studies, and animal models were excluded. Quality assessment was performed using the Newcastle-Ottawa Scale, and findings were synthesized narratively. Five articles encompassing 2,692 participants met the inclusion criteria. The included studies consistently demonstrated significant overexpression of hPG80 in CRC patients compared to non-cancer controls, with an increased median progastrin concentration in the CRC group (27.5 pmol/L) compared to patients with polyps or normal controls. Furthermore, hPG80 levels decreased significantly post-surgery (from 272.3 ± 12.0 pmol/L to 161.3 ± 11.0 pmol/L), reflecting its sensitivity to tumor burden and potential for treatment monitoring. Methodologically, literature has shifted from early radioimmunoassays to safer, cost-effective enzyme-linked immunosorbent assays (ELISA). A meta-analysis was not feasible due to variations in analytes, assays, populations, thresholds, and a lack of CRC-specific sensitivity, specificity, or area under the curve data. This review highlights hPG80’s promise as a reliable, reproducible blood-based biomarker for CRC integration into BCSPs and symptomatic pathways. However, optimal thresholds, stage-specific correlation, molecular subtypes, and cost-effectiveness remain unanswered. The ongoing MOTION trial (NCT07035691) is currently evaluating hPG80’s performance within UK symptomatic suspected colorectal cancer referral pathways.
- Open Access
Design, Fabrication, and Ex-vivo Validation of an Active Capsule Endoscope
Background and Aims: Active capsule endoscopy could advance gastrointestinal diagnostics by enabling controlled navigation beyond passive peristalsis. However, current systems are often limited by inefficient propulsion, high power demands, or reliance on external actuation. Herein, we designed, developed and evaluated a novel electromagnetic impact-actuated capsule endoscope incorporating a ferromagnetic rail-enhanced locomotion mechanism. Methods: The capsule employed an internal electromagnetic actuator comprising a movable coil-armature assembly guided along a ferromagnetic rail and surrounded by permanent magnets. Controlled current pulses generated reciprocating motion and propulsion through momentum transfer. Bench-top testing using a deformable intestinal model assessed locomotion and power consumption. Ex-vivo experiments were subsequently performed in porcine intestine under dry and physiologically simulated wet conditions. Transit speed, power consumption, and system stability were recorded. Results: Bench-top testing demonstrated stable propulsion at speeds up to 8.5 mm/s with a mean power consumption of 84 mW. During ex-vivo evaluation, mean capsule velocities were 1.95 mm/s and 7.2 mm/s under dry and wet conditions, respectively. Average power consumption was 96 mW and 193 mW. The actuator maintained reliable locomotion while preserving a compact system volume of ∼6.19 cm 3 . Lubricated conditions, representative of the intestinal environment, resulted in enhanced propulsion efficiency despite a concomitant increase in instantaneous power consumption. Conclusion: The electromagnetic impact-actuated capsule demonstrated reliable locomotion in biologically relevant ex-vivo environments while maintaining compact dimensions and moderate power requirements. Ferromagnetic rail-enhanced flux concentration offers a promising propulsion strategy for future actively navigated and therapeutic capsule endoscopy platforms.
Open AccessDesign, Fabrication, and Ex-vivo Validation of an Active Capsule Endoscope
Background and Aims: Active capsule endoscopy could advance gastrointestinal diagnostics by enabling controlled navigation beyond passive peristalsis. However, current systems are often limited by inefficient propulsion, high power demands, or reliance on external actuation. Herein, we designed, developed and evaluated a novel electromagnetic impact-actuated capsule endoscope incorporating a ferromagnetic rail-enhanced locomotion mechanism. Methods: The capsule employed an internal electromagnetic actuator comprising a movable coil-armature assembly guided along a ferromagnetic rail and surrounded by permanent magnets. Controlled current pulses generated reciprocating motion and propulsion through momentum transfer. Bench-top testing using a deformable intestinal model assessed locomotion and power consumption. Ex-vivo experiments were subsequently performed in porcine intestine under dry and physiologically simulated wet conditions. Transit speed, power consumption, and system stability were recorded. Results: Bench-top testing demonstrated stable propulsion at speeds up to 8.5 mm/s with a mean power consumption of 84 mW. During ex-vivo evaluation, mean capsule velocities were 1.95 mm/s and 7.2 mm/s under dry and wet conditions, respectively. Average power consumption was 96 mW and 193 mW. The actuator maintained reliable locomotion while preserving a compact system volume of ∼6.19 cm 3 . Lubricated conditions, representative of the intestinal environment, resulted in enhanced propulsion efficiency despite a concomitant increase in instantaneous power consumption. Conclusion: The electromagnetic impact-actuated capsule demonstrated reliable locomotion in biologically relevant ex-vivo environments while maintaining compact dimensions and moderate power requirements. Ferromagnetic rail-enhanced flux concentration offers a promising propulsion strategy for future actively navigated and therapeutic capsule endoscopy platforms.
- Open Access
- 6 March 2026
- Published by SAGE Publications in Journal of Low Frequency Noise, Vibration and Active Control
- Vol. 45 (3) , 1877-1897
Modelling and forward motion of vibro-impact capsules using magnetic actuation: Application of optimal & adaptive sliding mode control
Purpose: Capsule endoscopy offers a minimally invasive approach to gastrointestinal (GI) diagnostics but is limited by passive propulsion, which restricts controllability and risks suboptimal visualisation in complex anatomical regions. This study aims to develop and validate advanced control strategies for the CAPSUBOT, a vibro-impact robotic active capsule endoscope, enabling precise navigation and sustained motion within the GI tract. Methods: A two-degree-of-freedom (2-DOF) navigation system is implemented to control the relative motion of the inner mass with respect to the outer mass of the capsule. The capsule dynamics are mathematically modelled and formulated in the state-space domain. Linear Quadratic Regulator (LQR) and various Sliding Mode Controllers (SMC), including first-order SMC, second-order SMC, Integral SMC (ISMC), and Terminal SMC (TSMC), are designed and simulated using MATLAB/Simulink. Frictional forces and interaction effects are incorporated to emulate realistic operational conditions. The controllers’ performance in tracking desired trajectories is systematically evaluated, and the potential for optimisation of LQR weighting matrices using computational techniques such as artificial bee colony, genetic algorithm, particle swarm optimisation, and reinforcement learning is discussed. Results: Simulation results demonstrate that both LQR and SMC controllers can effectively guide the CAPSUBOT along commanded trajectories. First-order SMC, ISMC, and TSMC exhibit particularly strong performance in achieving steady-state tracking of the inner mass position and velocity, whereas LQR offers improved trajectory tracking under nominal conditions. The SMC controllers show robustness against disturbances and system uncertainties, supporting their use for sustained in vivo motion. Some time delays are observed in the SMC responses, highlighting areas for further improvement. Conclusion: This work establishes a framework for actively controlling a vibro-impact robotic capsule endoscope using LQR and SMC strategies, providing unified principles for the interaction of inner and outer capsule masses under feedback-controlled actuation. While the controllers demonstrate feasibility and robustness, limitations remain: SMC time delays and computational complexity in real-time implementation warrant further investigation. Future work will focus on integrating artificial intelligence-based reinforcement learning, neural networks, and fuzzy logic to develop faster, adaptive controllers. Overall, the study contributes both practical guidance for CAPSUBOT navigation and generalized control principles that may inform the design of other active capsule endoscopy systems.
- 6 March 2026
- Published by SAGE Publications in Journal of Low Frequency Noise, Vibration and Active Control
- Vol. 45 (3) , 1877-1897
Open AccessModelling and forward motion of vibro-impact capsules using magnetic actuation: Application of optimal & adaptive sliding mode control
Purpose: Capsule endoscopy offers a minimally invasive approach to gastrointestinal (GI) diagnostics but is limited by passive propulsion, which restricts controllability and risks suboptimal visualisation in complex anatomical regions. This study aims to develop and validate advanced control strategies for the CAPSUBOT, a vibro-impact robotic active capsule endoscope, enabling precise navigation and sustained motion within the GI tract. Methods: A two-degree-of-freedom (2-DOF) navigation system is implemented to control the relative motion of the inner mass with respect to the outer mass of the capsule. The capsule dynamics are mathematically modelled and formulated in the state-space domain. Linear Quadratic Regulator (LQR) and various Sliding Mode Controllers (SMC), including first-order SMC, second-order SMC, Integral SMC (ISMC), and Terminal SMC (TSMC), are designed and simulated using MATLAB/Simulink. Frictional forces and interaction effects are incorporated to emulate realistic operational conditions. The controllers’ performance in tracking desired trajectories is systematically evaluated, and the potential for optimisation of LQR weighting matrices using computational techniques such as artificial bee colony, genetic algorithm, particle swarm optimisation, and reinforcement learning is discussed. Results: Simulation results demonstrate that both LQR and SMC controllers can effectively guide the CAPSUBOT along commanded trajectories. First-order SMC, ISMC, and TSMC exhibit particularly strong performance in achieving steady-state tracking of the inner mass position and velocity, whereas LQR offers improved trajectory tracking under nominal conditions. The SMC controllers show robustness against disturbances and system uncertainties, supporting their use for sustained in vivo motion. Some time delays are observed in the SMC responses, highlighting areas for further improvement. Conclusion: This work establishes a framework for actively controlling a vibro-impact robotic capsule endoscope using LQR and SMC strategies, providing unified principles for the interaction of inner and outer capsule masses under feedback-controlled actuation. While the controllers demonstrate feasibility and robustness, limitations remain: SMC time delays and computational complexity in real-time implementation warrant further investigation. Future work will focus on integrating artificial intelligence-based reinforcement learning, neural networks, and fuzzy logic to develop faster, adaptive controllers. Overall, the study contributes both practical guidance for CAPSUBOT navigation and generalized control principles that may inform the design of other active capsule endoscopy systems.
- Open Access
- 30 January 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (1) , 012012
State of the art in soft eversion robots for colonoscopy: a review
This review explores the current state of eversion robotics in the context of colonoscopy, given the need for less invasive, more patient-friendly screening technologies. Conventional colonoscopy often leads to discomfort and patient reluctance, contributing to delayed diagnoses and high colorectal cancer mortality rates. Eversion robots, also known as vine robots or soft growing robots are soft, pressure-driven devices that extend by everting from the tip whilst offering a promising option by enabling frictionless advancement and potentially pain-free procedures. We examine the key challenges and opportunities in adapting eversion robots for clinical endoscopic use, focusing on material selection, actuation, steering, and payload delivery. From the literature, thermoplastic polyurethane emerges as the most viable material for the robot’s sleeve due to its airtightness, biocompatibility, suitability for heat or ultrasonic welding, and availability in highly flexible thin layers. Tip-steering mechanisms are identified as the most effective strategies for navigation, allowing high flexibility without increasing the wall thickness of the robot, as required in alternative approaches using distributed actuation mechanisms. The review also evaluates strategies for integrating functional tools at the tip of the robot, concluding that cap-free designs provide superior adaptability to the varying colon diameter, preserve compressibility, and keep tip friction to a minimum, unlike cap-based payload delivery methods. By consolidating current research and identifying pathways for innovation, this review supports the development of eversion soft robots as a next-generation solution for minimally invasive colorectal diagnostics and therapy.
- 30 January 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (1) , 012012
Open AccessState of the art in soft eversion robots for colonoscopy: a review
This review explores the current state of eversion robotics in the context of colonoscopy, given the need for less invasive, more patient-friendly screening technologies. Conventional colonoscopy often leads to discomfort and patient reluctance, contributing to delayed diagnoses and high colorectal cancer mortality rates. Eversion robots, also known as vine robots or soft growing robots are soft, pressure-driven devices that extend by everting from the tip whilst offering a promising option by enabling frictionless advancement and potentially pain-free procedures. We examine the key challenges and opportunities in adapting eversion robots for clinical endoscopic use, focusing on material selection, actuation, steering, and payload delivery. From the literature, thermoplastic polyurethane emerges as the most viable material for the robot’s sleeve due to its airtightness, biocompatibility, suitability for heat or ultrasonic welding, and availability in highly flexible thin layers. Tip-steering mechanisms are identified as the most effective strategies for navigation, allowing high flexibility without increasing the wall thickness of the robot, as required in alternative approaches using distributed actuation mechanisms. The review also evaluates strategies for integrating functional tools at the tip of the robot, concluding that cap-free designs provide superior adaptability to the varying colon diameter, preserve compressibility, and keep tip friction to a minimum, unlike cap-based payload delivery methods. By consolidating current research and identifying pathways for innovation, this review supports the development of eversion soft robots as a next-generation solution for minimally invasive colorectal diagnostics and therapy.
- Open Access
- 21 October 2025
- Published by Springer Nature in Research Square
A Handheld Tool for Temporal and Spatial Young's Modulus Characterization of Soft Materials: Towards Point-of-Care Soft Tissue Assessment
Palpation is a simple, rapid, and important technique in physical examination, by which physicians assess tissue characteristics. It informs decisions about whether to advocate for expensive, time-consuming imaging procedures. Its primary limitation is its dependence on the clinician's experience, making standardization of findings challenging. Although various tools have been proposed to increase clinical objectivity, accessible and affordable devices capable of quantifying tissue properties remain scarce. This paper introduces SensoPal, a portable palpation-based system that measures the temporal and spatial Young’s modulus of soft materials, thereby offering quantitative non-invasive tissue stiffness assessment. SensoPal integrates a handheld tool with a miniature load cell and a magnetometer to measure Young’s modulus of soft materials. Coupled with a low-cost camera for position tracking, SensoPal generates spatial stiffness maps that visualize regions of varying stiffness across examined tissue. A user study demonstrated that SensoPal measured the Young’s modulus of soft materials at rates of ∼ 87% (±4%) for accuracy and ∼ 86% (±4%) for repeatability. Notably, in a localization task, deep-seated nodules that were not detectable by touch alone were identified using stiffness maps. These results establish SensoPal as a reliable, low-cost platform for quantitative tissue characterization, with potential applications in point-of-care diagnostics, telemedicine, and patient self-assessment.
- 21 October 2025
- Published by Springer Nature in Research Square
Open AccessA Handheld Tool for Temporal and Spatial Young's Modulus Characterization of Soft Materials: Towards Point-of-Care Soft Tissue Assessment
Palpation is a simple, rapid, and important technique in physical examination, by which physicians assess tissue characteristics. It informs decisions about whether to advocate for expensive, time-consuming imaging procedures. Its primary limitation is its dependence on the clinician's experience, making standardization of findings challenging. Although various tools have been proposed to increase clinical objectivity, accessible and affordable devices capable of quantifying tissue properties remain scarce. This paper introduces SensoPal, a portable palpation-based system that measures the temporal and spatial Young’s modulus of soft materials, thereby offering quantitative non-invasive tissue stiffness assessment. SensoPal integrates a handheld tool with a miniature load cell and a magnetometer to measure Young’s modulus of soft materials. Coupled with a low-cost camera for position tracking, SensoPal generates spatial stiffness maps that visualize regions of varying stiffness across examined tissue. A user study demonstrated that SensoPal measured the Young’s modulus of soft materials at rates of ∼ 87% (±4%) for accuracy and ∼ 86% (±4%) for repeatability. Notably, in a localization task, deep-seated nodules that were not detectable by touch alone were identified using stiffness maps. These results establish SensoPal as a reliable, low-cost platform for quantitative tissue characterization, with potential applications in point-of-care diagnostics, telemedicine, and patient self-assessment.
- Open Access
- 25 September 2025
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 12, 1647010
Intraoperative techniques in realtime ureteric navigation. A brief narrative review and a video vignette
Background: Intraoperative ureteric injury, a well-documented but avoidable adverse event in pelvic surgery, is sometimes associated with low surgical volume and inexperience of the surgeon. The current literature describes several techniques that can help surgeons identify and protect the ureter during pelvic dissection, especially during complex procedures or repeat surgeries. This narrative review aims to highlight and present the currently available techniques for intraoperative ureteric identification in colorectal surgery and showcase the use of Indocyanine Green (ICG) in real-time ureter identification using a video vignette.Methods: A literature search of the PubMed database was performed from inception until May 14, 2025, to identify relevant articles reporting on intraoperative ureteric navigation techniques in colorectal surgery. Articles were analysed if they described the application of a technique in colorectal surgical procedures to identify the ureter intraoperatively. Given the narrative nature of this review, a qualitative synthesis was conducted by identifying the key themes described. In a video, we demonstrate a case of laparoscopic Hartmann's reversal of how ICG can facilitate surgical steps and the outcomes of a challenging procedure.Results: Techniques to identify the ureter intraoperatively during colorectal surgery were identified and discussed: (1) Image-Guided Techniques comprising Fluorescence Imaging and Use of Intraoperative Ultrasound; (2) Computer-Assisted and Augmented Reality Navigation consisting of 3D Model-Based Navigation, Augmented Reality, and Artificial Intelligence; and (3) Mechanical or Physical Identification Aid. These techniques highlight the improved outcomes in complex colorectal surgeries by preventing ureteric injury while enhancing the training process, even in complex, redo surgeries.Conclusion: Our narrative review highlights that image-guided surgery and augmented reality techniques are rapidly evolving in colorectal surgery. Our video vignette shows that intraoperative ureteric navigation makes challenging adhesiolysis easier and safer, which subsequently facilitates the training process in benign complex or re-do minimally invasive pelvic surgery.
- 25 September 2025
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 12, 1647010
Open AccessIntraoperative techniques in realtime ureteric navigation. A brief narrative review and a video vignette
Background: Intraoperative ureteric injury, a well-documented but avoidable adverse event in pelvic surgery, is sometimes associated with low surgical volume and inexperience of the surgeon. The current literature describes several techniques that can help surgeons identify and protect the ureter during pelvic dissection, especially during complex procedures or repeat surgeries. This narrative review aims to highlight and present the currently available techniques for intraoperative ureteric identification in colorectal surgery and showcase the use of Indocyanine Green (ICG) in real-time ureter identification using a video vignette.Methods: A literature search of the PubMed database was performed from inception until May 14, 2025, to identify relevant articles reporting on intraoperative ureteric navigation techniques in colorectal surgery. Articles were analysed if they described the application of a technique in colorectal surgical procedures to identify the ureter intraoperatively. Given the narrative nature of this review, a qualitative synthesis was conducted by identifying the key themes described. In a video, we demonstrate a case of laparoscopic Hartmann's reversal of how ICG can facilitate surgical steps and the outcomes of a challenging procedure.Results: Techniques to identify the ureter intraoperatively during colorectal surgery were identified and discussed: (1) Image-Guided Techniques comprising Fluorescence Imaging and Use of Intraoperative Ultrasound; (2) Computer-Assisted and Augmented Reality Navigation consisting of 3D Model-Based Navigation, Augmented Reality, and Artificial Intelligence; and (3) Mechanical or Physical Identification Aid. These techniques highlight the improved outcomes in complex colorectal surgeries by preventing ureteric injury while enhancing the training process, even in complex, redo surgeries.Conclusion: Our narrative review highlights that image-guided surgery and augmented reality techniques are rapidly evolving in colorectal surgery. Our video vignette shows that intraoperative ureteric navigation makes challenging adhesiolysis easier and safer, which subsequently facilitates the training process in benign complex or re-do minimally invasive pelvic surgery.
- 1 October 2024
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 6 (4) , 042003
A structured framework to evaluate capsule endoscope locomotion systems
Although capsule endoscopes have advanced significantly over the past two decades, their original passive design remains. Developing active locomotion systems for capsule endoscopes is a research-intensive field, and several such systems have been devised, using a variety of bioengineering solutions. While many of these systems are at various stages of testing-from theoretical to bench to in-vivo-only one has made it to pre-clinical trials. What is clear is the absence of a standardised system to evaluate and compare the different technologies. In this paper, we set out a structured framework with which to evaluate capsule endoscope locomotion systems (CELSs). The criteria set upon which it is based is derived from agreed clinically optimal conditions. The existing literature on CELS is then systematically reviewed and analysed using the framework, to demonstrate its validity. The average design score for existing CELS is 60.10% (range: 44.54%–78.74%). We found that the lowest-performing designs used inchworm and vibratory locomotion, whereas the highest-scoring designs all had magnetic actuation incorporated in some form. It is expected that the proposed new framework will enable clinicians, researchers, and manufacturers to consider global evaluative criteria when developing CELS and to apply them to existing and future system solutions.
- 1 October 2024
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 6 (4) , 042003
A structured framework to evaluate capsule endoscope locomotion systems
Although capsule endoscopes have advanced significantly over the past two decades, their original passive design remains. Developing active locomotion systems for capsule endoscopes is a research-intensive field, and several such systems have been devised, using a variety of bioengineering solutions. While many of these systems are at various stages of testing-from theoretical to bench to in-vivo-only one has made it to pre-clinical trials. What is clear is the absence of a standardised system to evaluate and compare the different technologies. In this paper, we set out a structured framework with which to evaluate capsule endoscope locomotion systems (CELSs). The criteria set upon which it is based is derived from agreed clinically optimal conditions. The existing literature on CELS is then systematically reviewed and analysed using the framework, to demonstrate its validity. The average design score for existing CELS is 60.10% (range: 44.54%–78.74%). We found that the lowest-performing designs used inchworm and vibratory locomotion, whereas the highest-scoring designs all had magnetic actuation incorporated in some form. It is expected that the proposed new framework will enable clinicians, researchers, and manufacturers to consider global evaluative criteria when developing CELS and to apply them to existing and future system solutions.
- Open Access
- 31 August 2024
- Published by Wiley in United European Gastroenterology Journal
- Vol. 12 (10) , 1417-1428
The impact of long‐course chemoradiotherapy on the myenteric plexus, neuromuscular functions and responses to prokinetic drugs in the human rectum
Background & Aims: The long‐term effects of chemoradiotherapy on human rectum are poorly understood. The aims were to investigate changes in inflammatory status, myenteric neuron numbers/phenotype, neuromuscular functions and prokinetic drug efficacy. Methods: Macroscopically normal proximal‐to‐mid rectum was obtained from 21 patients undergoing surgery for bowel cancer, 98 days (range: 63–350) after concurrent capecitabine and pelvic radiotherapy, and 19 patients without chemoradiotherapy. Inflammatory status was measured by H&E, CD45 staining and qPCR. Myenteric neurons were examined by immunohistochemistry. Neuromuscular functions and drug efficacy were studied using exogenous agents and electrical field stimulation (EFS) to activate intrinsic nerves. Results: Inflammation was not detected. Numbers of myenteric ganglia/neurons were unchanged (11.7 ± 2.4 vs. 10.3 ± 2.2 neurons/mm myenteric plexus with/without chemoradiotherapy) as were the numbers of cholinergic/nitrergic neurons. EFS stimulated cholinergic and nitrergic neurons so the contractile response of the muscle was the sum of both but dominated by cholinergic (causing contraction) or less often, nitrergic activity (relaxation), followed, after termination of EFS, by neuronally mediated contraction. Inhibition of nitric oxide synthase (by L‐NAME 300 μM) more clearly defined EFS‐evoked contractions. The 5‐HT 4 agonist prucalopride 10 μM and the cholinesterase inhibitor donepezil 1 µM, respectively increased and greatly increased the composite contractile response to EFS (measured as ‘area‐under‐the curve’) and the contractions isolated by L‐NAME (respectively, by 22 ± 14% and 334 ± 87%; n = 11/8). After chemoradiotherapy, nitrergic‐mediated muscle relaxations occurred more often during EFS (in 29.8 ± 6.1% preparations vs. 12.6 ± 5.1% without chemoradiotherapy, n = 21/18). With L‐NAME, the ability of prucalopride to facilitate EFS‐evoked contraction was lost and that of donepezil approximately halved (contractions increased by 132 ± 36%; n = 8). Conclusions: Several months after chemoradiotherapy, the rectum was not inflamed and myenteric neuron numbers/phenotype unchanged. However, nitrergic activity was increased relative to cholinergic activity, and prokinetic‐like drug activity was lost or greatly reduced. Thus, chemoradiotherapy causes long‐term changes in neuromuscular functions and markedly reduces the efficacy of drugs for treating constipation.
- 31 August 2024
- Published by Wiley in United European Gastroenterology Journal
- Vol. 12 (10) , 1417-1428
Open AccessThe impact of long‐course chemoradiotherapy on the myenteric plexus, neuromuscular functions and responses to prokinetic drugs in the human rectum
Background & Aims: The long‐term effects of chemoradiotherapy on human rectum are poorly understood. The aims were to investigate changes in inflammatory status, myenteric neuron numbers/phenotype, neuromuscular functions and prokinetic drug efficacy. Methods: Macroscopically normal proximal‐to‐mid rectum was obtained from 21 patients undergoing surgery for bowel cancer, 98 days (range: 63–350) after concurrent capecitabine and pelvic radiotherapy, and 19 patients without chemoradiotherapy. Inflammatory status was measured by H&E, CD45 staining and qPCR. Myenteric neurons were examined by immunohistochemistry. Neuromuscular functions and drug efficacy were studied using exogenous agents and electrical field stimulation (EFS) to activate intrinsic nerves. Results: Inflammation was not detected. Numbers of myenteric ganglia/neurons were unchanged (11.7 ± 2.4 vs. 10.3 ± 2.2 neurons/mm myenteric plexus with/without chemoradiotherapy) as were the numbers of cholinergic/nitrergic neurons. EFS stimulated cholinergic and nitrergic neurons so the contractile response of the muscle was the sum of both but dominated by cholinergic (causing contraction) or less often, nitrergic activity (relaxation), followed, after termination of EFS, by neuronally mediated contraction. Inhibition of nitric oxide synthase (by L‐NAME 300 μM) more clearly defined EFS‐evoked contractions. The 5‐HT 4 agonist prucalopride 10 μM and the cholinesterase inhibitor donepezil 1 µM, respectively increased and greatly increased the composite contractile response to EFS (measured as ‘area‐under‐the curve’) and the contractions isolated by L‐NAME (respectively, by 22 ± 14% and 334 ± 87%; n = 11/8). After chemoradiotherapy, nitrergic‐mediated muscle relaxations occurred more often during EFS (in 29.8 ± 6.1% preparations vs. 12.6 ± 5.1% without chemoradiotherapy, n = 21/18). With L‐NAME, the ability of prucalopride to facilitate EFS‐evoked contraction was lost and that of donepezil approximately halved (contractions increased by 132 ± 36%; n = 8). Conclusions: Several months after chemoradiotherapy, the rectum was not inflamed and myenteric neuron numbers/phenotype unchanged. However, nitrergic activity was increased relative to cholinergic activity, and prokinetic‐like drug activity was lost or greatly reduced. Thus, chemoradiotherapy causes long‐term changes in neuromuscular functions and markedly reduces the efficacy of drugs for treating constipation.
- Open Access
- 1 February 2023
- Published by MDPI AG in Preprints.org
Introducing a Structured Daily Multi-Disciplinary Board Round to Safely Enhance Surgical Ward Patient Flow in the Bed Shortage Era: A Quality Improvement Research Report
Hospital bed shortage is a worldwide concern. Beds unavailability has caused elective surgery cancellations, at our hospital peaking in spring 2016 at over 50%. This is often due to difficult patient step-down from intensive care (ICU) and high-dependency units (HDU). In our general/digestive surgery service admitting approximately 1000 patients yearly, ward rounds were run on a consultant firm basis. We report a quality improvement (ISRCTN13976096) introducing in our service a structured daily multi-disciplinary board round framework (SAFER Surgery R2G) adapted from the “SAFER patient flow bundle” and the "Red to Green days” approaches to enhance flow, comparing the previous year to 2017, when our framework was applied for 12 months. We used a Plan-Do-Study-Act (PDSA) methodology. Our intervention consisted in 1) systematic communication of the key care plan after the afternoon ward rounds to the nurse in charge; 2) 30’ 10AM Monday-to-Friday multidisciplinary board rounds, attended daily by the senior-team and weekly by hospital and site managers, revising the key care plan aiming at safe, early discharges, assessing the appropriateness of each inpatient day and tackling any cause of delay. We measured patient flow by average length of stay (LOS), ICU/HDU step-downs and operation cancellations count, monitoring safety through early 30-day readmissions. Compliance was assessed by board round attendance and staff satisfaction rate surveys.After 12 months (PDSA 2, N=1032), LOS significantly decreased from 7.2(±8.9) to 6.3(±7.4) days (p=0.003); ICU/HDU bed step-down flow increased by 9.3% from 345 to 375 (p=0.197), surgery cancellations dropped from 38 to 15 (p=0.100). 30-day re-admissions increased from 0.9% (N=9) to 1.3% (N=14)(p=0.390). Average cross-specialty attendance was 80%. Satisfaction rates were >75%, regarding enhanced teamwork and faster decisions.The SAFER Surgery R2G framework has shown an increase in patient flow in the context of an enhanced multidisciplinary approach, requiring senior staff commitment to remain sustainable.
- 1 February 2023
- Published by MDPI AG in Preprints.org
Open AccessIntroducing a Structured Daily Multi-Disciplinary Board Round to Safely Enhance Surgical Ward Patient Flow in the Bed Shortage Era: A Quality Improvement Research Report
Hospital bed shortage is a worldwide concern. Beds unavailability has caused elective surgery cancellations, at our hospital peaking in spring 2016 at over 50%. This is often due to difficult patient step-down from intensive care (ICU) and high-dependency units (HDU). In our general/digestive surgery service admitting approximately 1000 patients yearly, ward rounds were run on a consultant firm basis. We report a quality improvement (ISRCTN13976096) introducing in our service a structured daily multi-disciplinary board round framework (SAFER Surgery R2G) adapted from the “SAFER patient flow bundle” and the "Red to Green days” approaches to enhance flow, comparing the previous year to 2017, when our framework was applied for 12 months. We used a Plan-Do-Study-Act (PDSA) methodology. Our intervention consisted in 1) systematic communication of the key care plan after the afternoon ward rounds to the nurse in charge; 2) 30’ 10AM Monday-to-Friday multidisciplinary board rounds, attended daily by the senior-team and weekly by hospital and site managers, revising the key care plan aiming at safe, early discharges, assessing the appropriateness of each inpatient day and tackling any cause of delay. We measured patient flow by average length of stay (LOS), ICU/HDU step-downs and operation cancellations count, monitoring safety through early 30-day readmissions. Compliance was assessed by board round attendance and staff satisfaction rate surveys.After 12 months (PDSA 2, N=1032), LOS significantly decreased from 7.2(±8.9) to 6.3(±7.4) days (p=0.003); ICU/HDU bed step-down flow increased by 9.3% from 345 to 375 (p=0.197), surgery cancellations dropped from 38 to 15 (p=0.100). 30-day re-admissions increased from 0.9% (N=9) to 1.3% (N=14)(p=0.390). Average cross-specialty attendance was 80%. Satisfaction rates were >75%, regarding enhanced teamwork and faster decisions.The SAFER Surgery R2G framework has shown an increase in patient flow in the context of an enhanced multidisciplinary approach, requiring senior staff commitment to remain sustainable.