JKJoost P. A. Kuijer

Joost P. A. Kuijer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joost P. A. Kuijer has a total of 559 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multiple Sclerosis–Specific Reference Curves for Brain Volumes to Explain Disease Severity

    by David R. van Nederpelt, Lonneke Bos, Rozemarijn M. Mattiesing, Eva M. Strijbis, Bastiaan Moraal, Joost Kuijer, Jeroen Hoogland, Henk Mutsaerts, Bernard Uitdehaag, Joep Killestein, et al.


  • Open Access

    Multi-cohort, multi-sequence harmonisation for cerebrovascular brain age

    by Mathijs B.J. Dijsselhof, Candace Moore, Saba Amiri, Mervin Tee, Saima Hilal, Christopher Chen, Bert-Jan H. van Den Born, Wibeke Nordhøy, Ole A. Andreassen, Lars T. Westlye, et al.

    Higher brain-predicted age gaps (BAG), based on anatomical brain scans, have been associated with cognitive decline amongst elderly participants. Adding a cerebrovascular component, in the form of arterial spin labelling (ASL) perfusion MRI, can improve the BAG predictions and potentially increase sensitivity to cardiovascular health, a contributor to brain ageing and cognitive decline. ASL acquisition differences are likely to influence brain age estimations, and data harmonisation becomes indispensable for multi-cohort brain age studies including ASL. In this multi-cohort, multi-sequence study, we investigate harmonisation methods to improve the generalisability of cerebrovascular brain age. A multi-study dataset of 2608 participants was used, comprising structural T1-weighted (T1w), FLAIR, and ASL 3T MRI data. The single scanner training dataset consisted of 806 healthy participants, age 50 ± 17, 18–95 years. The testing datasets comprised four cohorts (n = 1802, age 67 ± 8, 37–90 years). Image features included grey and white matter (GM/WM) volumes (T1w), WM hyperintensity volumes and counts (FLAIR), and ASL cerebral blood flow (CBF) and its spatial coefficient of variation (sCoV). Feature harmonisation was performed using NeuroComBat, CovBat, NeuroHarmonize, OPNested ComBat, AutoComBat, and RELIEF. ASL-only and T1w+FLAIR+ASL brain age models were trained using ExtraTrees. Model performance was assessed through the mean absolute error (MAE) and mean BAG. ASL feature differences between cohorts decreased after harmonisation for all methods (p < 0.05), mostly for RELIEF. Negative associations between age and GM CBF (b = -0.37, R2 = 0.13, unharmonised) increased after harmonisation for all methods (b < -0.42, R2 > 0.12), but weakened for RELIEF (b = -0.28, R2 = 0.14), In the ASL-only model, MAE improved for all harmonisation methods from 11.1 ± 7.5 years to less than 8.8 ± 6.2 years (p < 0.001), while BAGs changed from 0.6 ± 13.4 years to less than -1.03 ± 7.92 years (p < 0.001). For T1w+FLAIR+ASL, MAE (5.9 ± 4.6 years, unharmonised) increased for all harmonisation methods non-significantly to above 6.0 ± 4.9 years (p > 0.42) and significantly for RELIEF (6.4 ± 5.2 years, p = 0.02), while BAGs non-significantly differed from -1.6 ± 7.3 years to between -1.3 ± 4.7 and -2.0 ± 8.0 years (p > 0.82). In general, the ASL-specific parameter harmonisation method AutoComBat performed nominally best. Harmonisation of ASL features improves feature consistency between studies and also improves brain age estimations when only ASL features are used. ASL-specific parameter harmonisation methods perform nominally better than basic mean and scale adjustment or latent-factor approaches, suggesting that ASL acquisition parameters should be considered when harmonising ASL data. Although multi-modal brain age estimations were improved less by ASL-only harmonisation, possibly due to weaker associations between age and ASL features compared with T1w features importance, studies investigating pathological ASL-feature distributions might still benefit from harmonisation. These findings advocate for ASL-parameter specific harmonisation to explore associations between cardiovascular risk factors, brain ageing, and cognitive decline using multi-cohort ASL and cerebrovascular brain age studies.


  • Open Access

    DICOM datasets for reproducible neuroimaging research across manufacturers and software versions

    by Christopher Rorden, Benoît Béranger, Hu Cheng, Matthew Clemence, Clément Debacker, Brice Fernandez, Yaroslav O. Halchenko, Michael P. Harms, Bharath Holla, Isaiah Innis, et al.

    DICOM is an industry-standard for medical imaging data targeted at interoperability across systems. This enables transfer, storage and processing of imaging data regardless of the manufacturer. Pragmatically, manufacturers often store detailed acquisition parameters in private rather than public DICOM tags. In parallel, the DICOM standard itself has gradually evolved by introducing new public tags and properties to better capture emerging imaging technologies. Accurately extracting these details is essential for reproducible neuroimaging research. To address this need, we created a series of DICOM datasets illustrating how various manufacturers encode acquisition details that are critical for modern processing and analysis. These minimal test cases, covering CT and MR modalities, highlight manufacturer-specific conventions, including the use of public tags, private tags, and proprietary data structures. For each DICOM dataset, we provide corresponding NIfTI-formatted images with metadata JSON files following the BIDS standard, using consistent terminology to mitigate variations in how manufacturers encode acquisition details. Our repository provides validation datasets for any tool that is intended to extract acquisition details from medical imaging data.


  • Open Access

    Multiple Sclerosis–Specific Reference Curves for Brain Volumes to Explain Disease Severity

    by David Rudolf van Nederpelt, Lonneke Bos, Rozemarijn M. Mattiesing, Eva M.M. Strijbis, Bastiaan Moraal, Joost Kuijer, Jeroen Hoogland, Henk J.M.M. Mutsaerts, Bernard Uitdehaag, Joep Killestein, et al.

    Brain atrophy is relevant for understanding disease progression and treatment response in people with multiple sclerosis (pwMS). Automatic brain volume-reporting tools often rely on healthy control (HC) reference curves to interpret brain volumes, whereas brain volume loss is different in pwMS. This observational study aimed to develop an MS-specific reference model for brain volumes and evaluate its performance compared with HC-based curves, as a proof-of-concept. Participants, pwMS and HCs, from the Amsterdam MS cohort were included based on the availability of T1-weighted MR scans. Normalized brain volumes (NBVs) were obtained using commercially available software. The software program also provides NBV percentiles, based on age-specific and sex-specific HC curves, grouped into NBV quartiles, describing deviation from expected NBVs. Disease severity was determined with the MS severity score (MSSS), Symbol Digit Modalities Test (SDMT), and 9-Hole Peg Test (9HPT). An MS-specific model was developed by regressing NBVs against age, sex, disease duration, and MS phenotype. The resulting MS model was also used to classify pwMS into quartiles describing deviation from expected NBV, given the modeled patient characteristics, with leave-one-out predictions. Quartile classification from HC-based and MS-based reference curves was compared with MSSS using analysis of variance (ANOVA). Regressions for NBVs from 713 pwMS and 259 HCs (mean age: 49.1 ± 9.7 and 48.3 ± 10.1, %female: 70.4% and 67.2%, respectively) were significant for age, sex, disease duration, and phenotype, which were included in the MS-specific model. MS-specific model quartile designations significantly improved associations with MSSS values (p = 2.2*10-9, η2 = 0.06) compared with HC-based quartiles. MSSS values worsened with lower NBV quartiles in the MS-specific model (difference between quartiles 1-4 = -0.84, p = 6.1*10-3, 95% CI [-1.5 to -0.18])), which was not observed for HC-based quartiles (p = 0.98). Quartile group differences were observed for 9HPT (MS: p = 3.5*10-3, η2 = 0.02, HC: p = 6.6*10-3, η2 = 0.02) and SDMT (MS: p = 3.1*10-4, η2 = 0.05, HC: p = 5.4*10-4, η2 = 0.04) values, but MS-specific quartiles again improved quartile associations (p = 0.036, η2 = 0.01 and p = 0.02, η2 = 0.01, respectively). NBV values derived from an MS-specific reference model offer improved relevance for assessing disease severity compared with curves derived from age-specific and sex-specific HC reference models. Improving the model toward application in individual people could enhance clinical implementation.


  • Open Access

    Multi-cohort, multi-sequence harmonisation for cerebrovascular brain age

    by Mathijs Berend Johannes Dijsselhof, Candace Moore, Saba Amiri, Mervin Tee, Saima Hilal, Christopher Chen, Bert-Jan H. van Den Born, Wibeke Nordhøy, Ole Andreassen, Lars T. Westlye, et al.

    Introduction Higher brain-predicted age gaps (BAG), based on anatomical brain scans, have been associated with cognitive decline among elderly participants. Adding a cerebrovascular component, in the form of arterial spin labelling (ASL) perfusion MRI, can improve the BAG predictions and potentially increase sensitivity to cardiovascular health, a contributor to brain ageing and cognitive decline. ASL acquisition differences are likely to influence brain age estimations, and data harmonisation becomes indispensable for multi-cohort brain age studies including ASL. In this multi-cohort, multi-sequence study, we investigate harmonisation methods to improve the generalisability of cerebrovascular brain age. Methods A multi-study dataset of 2608 participants was used, comprising structural T1-weighted (T1w), FLAIR, and ASL 3T MRI data. The single scanner training dataset consisted of 806 healthy participants, age 50±17, 18-95 years. The testing datasets comprised four cohorts (n=1802, age 67±8, 37-90 years). Image features included grey and white matter (GM/WM) volumes (T1w), WM hyperintensity volumes and counts (FLAIR), and ASL cerebral blood flow (CBF) and its spatial coefficient of variation (sCoV). Feature harmonisation was performed using NeuroComBat, CovBat, NeuroHarmonize, OPNested ComBat, AutoComBat, and RELIEF. ASL-only and T1w+FLAIR+ASL brain age models were trained using ExtraTrees. Model performance was assessed through the mean absolute error (MAE) and mean BAG. Results ASL feature differences between cohorts decreased after harmonisation for all methods (p0.12) but weakened for RELIEF (b=-0.28, R2=0.14). In the ASL-only model, MAE improved for all harmonisation methods from 11.1±7.5 years to less than 8.8±6.2 years (p0.82). In general, the ASL-specific parameter harmonisation method AutoComBat performed nominally best. Discussion Harmonisation of ASL features improves feature consistency between studies and also improves brain age estimations when only ASL features are used. ASL-specific parameter harmonisation methods perform nominally better than basic mean and scale adjustment or latent-factor approaches, suggesting that ASL acquisition parameters should be considered when harmonising ASL data. Although multi-modal brain age estimations were improved less by ASL-only harmonisation, possibly due to weaker associations between age and ASL features compared to T1w features feature importance, studies investigating pathological ASL-feature distributions might still benefit from harmonisation. These findings advocate for ASL-parameter specific harmonisation to explore associations between cardiovascular risk factors, brain ageing, and cognitive decline using multi-cohort ASL and cerebrovascular brain age studies.

  • Open Access

    Repeatability and reproducibility of brain age estimates in multiple sclerosis for three publicly available models

    by Lonneke Bos, David R. van Nederpelt, J.H. Cole, E.M.M. Strijbis, B. Moraal, J.P.A. Kuijer, B.M.J. Uitdehaag, F. Barkhof, A.M. Wink, H. Vrenken, et al.


  • Open Access

    A signal model for fat‐suppressed T1‐mapping and dynamic contrast‐enhanced MRI with interrupted spoiled gradient‐echo readout

    by Myrte Wennen, Wilhelm Stehling, J. Tim Marcus, Joost P. A. Kuijer, Cristina Lavini, Leo M. A. Heunks, Gustav J. Strijkers, Bram F. Coolen, Aart J. Nederveen, Oliver J. Gurney‐Champion

    The conventional gradient‐echo steady‐state signal model is the basis of various spoiled gradient‐echo (SPGR) based quantitative MRI models, including variable flip angle (VFA) MRI and dynamic contrast‐enhanced MRI (DCE). However, including preparation pulses, such as fat suppression or saturation bands, disrupts the steady‐state and leads to a bias in T1 and DCE parameter estimates. This work introduces a signal model that improves the accuracy of VFA T1‐mapping and DCE for interrupted spoiled gradient‐echo (I‐SPGR) acquisitions. The proposed model was applied to a VFA T1‐mapping I‐SPGR sequence in the Gold Standard T1‐phantom (3 T), in the brain of four healthy volunteers (3 T), and to an abdominal DCE examination (1.5 T). T1‐values obtained with the proposed and conventional model were compared to reference T1‐values. Bland–Altman analysis (phantom) and analysis of variance (in vivo) were used to test whether bias from both methods was significantly different (p = 0.05). The proposed model outperformed the conventional model by decreasing the bias in the phantom with respect to the phantom reference values (mean bias ‐2 vs. ‐35% at 3 T) and in vivo with respect to the conventional SPGR (‐6 vs. ‐37% bias in T1, p < 0.01). The proposed signal model estimated approximately 48% (depending on baseline T1) higher contrast concentrations in vivo, which resulted in decreased DCE pharmacokinetic parameter estimates of up to 35%. The proposed signal model improves the accuracy of quantitative parameter estimation from disrupted steady‐state I‐SPGR sequences. It therefore provides a flexible method for applying fat suppression, saturation bands, and other preparation pulses in VFA T1‐mapping and DCE.


  • Open Access

    Validation of a semi-automated method to quantify lesion volume changes in multiple sclerosis on 2D proton-density-weighted scans based on image subtraction

    by Rozemarijn M. Mattiesing, Serena Stel, Alysha S. Mangroe, Iman Brouwer, Adriaan Versteeg, Ronald A. van Schijndel, Bernard M.J. Uitdehaag, Frederik Barkhof, Hugo Vrenken, Joost P.A. Kuijer


  • Open Access

    ExploreQC: A toolbox for MRI quality control in the EPAD multicentre study

    by Luigi Lorenzini, Silvia Ingala, Viktor Wottschel, Alle Meije Wink, Joost Kuijer, Carole H Sudre, Sven Haller, Jose Luis Molinuevo, Juan Domingo Gispert, David M Cash, et al.

    Background: Magnetic Resonance Imaging (MRI) of the brain is prone to artefacts that may worsen image quality and subsequent analyses. Despite the growing number of large‐scale multi‐institutional imaging studies, standardized approaches for defining inclusion and exclusion criteria on the basis of image data quality are still lacking and quality assessment is often based on visual inspection. We introduce ExploreQC, a MATLAB‐based toolbox which implements a semi‐automatic pipeline to assess QC metrics, select the most relevant parameters, and to derive informed inclusion thresholds.Methods: The efficacy of ExploreQC was demonstrated on scans from 436 participants of the multi‐centre European Prevention of Alzheimer’s Dementia (EPAD) longitudinal cohort study. Five different MRI sequences from five sites of the EPAD study were used: structural (T1w, FLAIR, diffusion MRI), resting state functional (rs‐fMRI) and ASL perfusion MRI. For each sequence, QC features were selected following a literature review of recently published studies on multi‐parameter QC (Alfaro‐Almagro, F. et al. 2018; Bastiani, M. et al. 2019; Esteban, O. et al. 2017; Fallatah, S. M. 2018; Shehzad, Z. 2015). Similar parameters were grouped in image feature domains (IFDs).Results: Table 1 shows the 38 QC features within 19 IFDs computed in the EPAD cohort covering each MRI scan‐type. ExploreQC generated within‐ and between‐site distribution plots of each QC parameter to identify outliers for subsequent visual inspection in order to establish the relevance of the parameter (Fig 1).Conclusions: ExploreQC facilitates the computation and visualization of informative QC parameters, within and between sites and modalities. Application of ExploreQC to the EPAD data showed that the investigation of distributions of different quantitative QC features can provide an overview of the general quality of the data, identify outliers and derive informed reference thresholds for exclusion criteria.


  • Effects of Acquisition Parameter Modifications and Field Strength on the Reproducibility of Brain Perfusion Measurements Using Arterial Spin-Labeling

    by K.P.A. Baas, J. Petr, J.P.A. Kuijer, A.J. Nederveen, H.J.M.M. Mutsaerts, K.C.C. van de Ven

    BACKGROUND AND PURPOSE: Although the added diagnostic value of arterial spin-labeling is shown in various cerebral pathologies, its use in clinical practice is limited. To encourage clinical adoption of ASL, we investigated the reproducibility of CBF measurements and the effects of variations in acquisition parameters compared to the recommended ASL implementation. MATERIALS AND METHODS: Thirty-four volunteers (mean age, 57.8 ± 17.0 years; range, 22–80 years) underwent two separate sessions (1.5T and 3T scanners from a single vendor) using a 15-channel head coil. Both sessions contained repeated 3D and 2D pseudocontinuous arterial spin-labeling scans using vendor-recommended acquisition parameters (recommendation paper–based), followed by three 3D pseudocontinuous arterial spin-labeling scans, two with postlabeling delays of 1600 and 2000 ms and one with increased spatial resolution. All scans were single postlabeling delay. Intrasession (identical acquisitions, scanned five minutes apart) and intersession (first 2D and 3D acquisitions of two sessions) reproducibility was examined as well as the effect of parameter variations on CBF. RESULTS: Intrasession CBF reproducibility was similar across image readouts and field strengths (within-subject coefficient of variation between 4.0% and 6.7%). Intersession within-subject coefficient of variation ranged from 6.6% to 14.8%. At 3T, the 3D acquisition with a higher spatial resolution resulted in less mixing of GM and WM signal, thus decreasing the bias in GM CBF between the 2D and 3D acquisitions (ΔCBF = 2.49 mL/100g/min [P < .001]). Postlabeling delay variations caused a modest bias (ΔCBF between −3.78 [P < .001] and 2.83 [P < .001] mL/100g/min). CONCLUSIONS: Arterial spin-labeling imaging is reproducible at both field strengths, and the reproducibility is not significantly correlated with age. Furthermore, 3T tolerates more acquisition parameter variations and allows more extensive optimizations so that 3D and 2D acquisitions can be compared.