Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Patrique Fiedler has a total of 165 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrochemical Characterization of Commercial Electroencephalography Bioelectrodes in Isotonic Saline Solution

    by Alexandra C. Alves, Patrique Fiedler, Carlos Fonseca

    The electrochemical performance of eight commercially available bioelectrodes for electrophysiological measurements was systematically evaluated in isotonic saline solution. The studied bioelectrodes included sintered Ag/AgCl pellet, cup and ring, an Ag/AgCl multipin, tin (Sn) ring and disc, a gold cup, and a stainless-steel needle. Open circuit potential (OCP) and drift rate, electrochemical impedance spectroscopy (EIS), and electrochemical noise (ECN) measurements were performed to assess interfacial stability, impedance behavior, and generated noise in time and frequency domains. Scanning electron microscopy (SEM) and Energy-dispersive X-ray spectroscopy (EDS) were used to study the morphology and chemical composition of the bioelectrodes. Ag/AgCl-based bioelectrodes exhibited the highest OCP stability and potential reproducibility, lowest impedance, and electrochemical noise, attributed to the fast and reversible Ag/AgCl electrochemical equilibrium, and high area related to roughness and porosity. EIS analysis showed predominantly low-resistance charge-transfer behavior and high capacitance for Ag/AgCl bioelectrodes, while tin, gold, and stainless-steel bioelectrodes displayed higher impedance and mixed capacitive/resistive responses associated with passive oxide films and slower interfacial kinetics. Tin, gold, and stainless-steel bioelectrodes also presented substantially higher low-frequency noise and OCP drift rate. Among all tested bioelectrodes, sintered Ag/AgCl bioelectrodes demonstrated the most favorable electrochemical characteristics for electrophysiological signal acquisition, particularly for low-amplitude and low-frequency biosignals.

  • Open Access

    Suppressing Non-Stationary Motion Artefacts in Mobile EEG Using Generalized Eigenvalue Decomposition

    by Mohammad Khazaei, Khadijeh Raeisi, Patrique Fiedler, Pierpaolo Croce, Filippo Zappasodi, Silvia Comani

    Mobile EEG enables investigating brain activity during real-world behaviour, but remains susceptible to motion artefacts, limiting signal interpretability and the use of advanced analytical techniques. Methods developed for removing motion-related artefacts induced by periodic activity like cycling, walking or juggling showed degraded performance with increasing movement variability and speed. To fill this gap, we developed a method based on generalized eigenvalue decomposition (GED) to identify and suppress highly variable, non-periodic—especially transient—artefacts due to very rapid, free full body movements of different types, as they occur during sports practice. By leveraging the contrast between covariance matrices of artefactual and resting-state EEG segments, this approach isolates motion-related components for removal during multichannel EEG signal reconstruction. The method was validated on two ecological datasets featuring stereotyped head and body movements and dynamic table tennis. Comparison with state-of-the-art technique showed superior performance of our method in terms of signal-to-error ratio (SER), artefact-to-residue ratio (ARR), brain spectral power preservation and computation time. Sensitivity analysis was applied to demonstrate the method’s robustness to parameter changes. These findings highlight the potential of the proposed method as a robust, generalizable approach for motion artefact suppression in mobile EEG, particularly when applied in extreme recording conditions like during active sports activity.

  • Open Access

    Comfortable Flower Electrodes for Dry EEG in Epilepsy and Clinical Neurophysiology Diagnostics

    by Dimitrios Dimitrakopoulos, Justus Marquetand, Joji Kuramatsu, Patrique Fiedler, Johannes Lang

    Dry electroencephalography (EEG) electrodes enable rapid, gel-free setups, which are crucial for point-of-care diagnostics, but often face challenges with comfort and signal quality—especially in a clinical context. Novel “flower” dry electrodes are a special type of reusable scalp electrodes for dry EEG, featuring a distinct flower-like shape with angled pins in three intertwined layers. While the new electrode design has been validated in an in vivo study on healthy volunteers, we tested its clinical applicability in a proof-of-concept study involving three patients diagnosed with epilepsy and delirium. The recordings were of high diagnostic quality, enabling the reliable identification of pathological patterns, such as generalized spike–wave complexes and intermittent delta activity, with a signal-to-noise ratio comparable to prior reports for sponge-based EEG systems (limited case series). The signal-to-noise ratio (SNR) proved to be sufficiently high for clinical diagnostic purposes, resulting in visually clear and interpretable EEG data that enabled effective assessment of patients’ neurophysiological signals. Consequently, our findings demonstrate that the comfortable flower-electrode design is a viable and effective tool for epilepsy diagnostics, extended recording, and clinical neurophysiology. It represents a significant step towards patient-centered and gel-free EEG technology, specifically in point-of-care and emergency applications, without compromising the diagnostic quality of the recordings.

  • Open Access

    Validation of an Automated Seizure Detection Procedure for Multi-Channel Neonatal EEG

    by Cris Micheli, Antonia Thelen, Maarten De Vos, Anneleen Dereymaeker, Jens Haueisen, Patrique Fiedler

    This study validates an automated seizure detection algorithm for multi-channel neonatal EEG, adapting a previously published method to a dataset with fewer electrodes. The Python-based implementation, SDApy, was applied to EEG recordings from 23 neonates to classify seizure and non-seizure epochs using a support vector machine trained on an independent dataset. The algorithm employs time- and frequency-domain features and maintains high generalization across different recording setups, achieving robust performance despite using only nine electrodes instead of nineteen. Evaluation metrics, including F1 scores and precision—recall curves, confirmed strong agreement between algorithm predictions and expert annotations for most patients. SDApy’s open-source implementation enhances accessibility compared with earlier MatLab versions, offering a transparent and cost-effective approach to clinical EEG analysis. The pipeline can operate with labels from a single expert, supports data pre-labeling for deep learning, and integrates well into neonatal intensive care unit monitoring workflows. Overall, SDApy demonstrates reliable adaptation to reduced-channel EEG and shows potential for real-time seizure detection, personalized threshold optimization, and integration into multimodal neurophysiological monitoring systems.


  • Open Access

    Prognostic potential of radiomics evaluation of lung artery thrombus for pulmonary embolism patients

    by Lea Ehrhardt, Patrique Fiedler, Alexey Surov, Sylvia Saalfeld

    Purpose: This study evaluates radiomics correlation with mortality and suitability as prognostic indicator for troponin for pulmonary embolism to enhance prognostic accuracy and guide personalized treatment strategies with the help of machine learning. We conducted an initial study focusing on texture information of the arterial thrombus. Method: Computed tomography (CT) of the lung from 86 patients with pulmonary embolism was used. As target variables, we used patients 30-day mortality and troponin results. Each arterial thrombus was manually segmented. After the extraction of their radiomics features and the reduction via correlation analysis and 12 feature selection methods, these and the target variables were given to 12 different classification methods to record the accuracies (Acc.), F1-scores (F1) and ROC curve areas under the curve (AUC) for comparison and evaluation. Results: The resulting accuracy achieved was 0.967, the F1-score 0.973 for class 0 and 0.967 for class 1 and the AUC around 0.9686. The feature selection methods which resulted in the highest results were ReliefF (RF), Logistic Regression (LOR) and CART Classification (CARTC). For the classification methods, Support Vector Machines (SVM), eXtreme Gradiant Boosting (XGB) and Ensemble Bagged Trees (EBT) lead to the highest results. Firstorder, Shape and gray-level co-occurrence matrix (GLCM) were the most selected radiomics feature classes. Conclusion: Within this study, we conducted radiomics feature extraction within a medical image data analysis pipeline with subsequent correlation analysis and training of classifiers for patients with pulmonary lung embolism. We could show that the radiomics features correlated with patient’s morphology as well as troponin range with an accuracy of 0.967 and 0.9302, respectively, yield high potential for prognosis and treatment strategy of pulmonary embolism patients in the future.


  • Open Access

    Head-Specific Spatial Spectra of Electroencephalography Explained: A Sphara and BEM Investigation

    by Uwe Graichen, Sascha Klee, Patrique Fiedler, Lydia Hofmann, Jens Haueisen

    Electroencephalography (EEG) is a non-invasive biosensing platform with a spatial-frequency content that is of significant relevance for a multitude of aspects in the neurosciences, ranging from optimal spatial sampling of the EEG to the design of spatial filters and source reconstruction. In the past, simplified spherical head models had to be used for this analysis. We propose a method for spatial frequency analysis in EEG for realistically shaped volume conductors, and we exemplify our method with a five-compartment Boundary Element Method (BEM) model of the head. We employ the recently developed technique for spatial harmonic analysis (Sphara), which allows for spatial Fourier analysis on arbitrarily shaped surfaces in space. We first validate and compare Sphara with the established method for spatial Fourier analysis on spherical surfaces, discrete spherical harmonics, using a spherical volume conductor. We provide uncertainty limits for Sphara. We derive relationships between the signal-to-noise ratio (SNR) and the required spatial sampling of the EEG. Our results demonstrate that conventional 10–20 sampling might misestimate EEG power by up to 50%, and even 64 electrodes might misestimate EEG power by up to 15%. Our results also provide insights into the targeting problem of transcranial electric stimulation.


  • Open Access

    Changes of EEG beta band power and functional connectivity during spaceflight: a retrospective study

    by Adrián Quivira-Lopesino, María Sevilla-García, Pablo Cuesta, Sandra Pusil, Ricardo Bruña, Patrique Fiedler, Ana Maria Cebolla, Guy Cheron, Michael Funke, Fernando Maestu

    Spaceflight exposes astronauts to unique conditions like microgravity, which may affect brain function, though it remains underexplored compared to other physiological systems. Astronauts often report temporary neurological symptoms, such as disorientation, visual disturbances, and motor issues, potentially linked to structural and electrophysiological brain changes. To investigate this, electroencephalography (EEG) is a reliable tool to study brain activity in space, measuring oscillatory activity and functional connectivity (FC). This study analyzed EEG data from five male astronauts during three stages: pre-flight, during low Earth orbit (LEO), and post-flight in a 2-min task-free eyes-closed (EC) condition followed by another 2-min of eyes-open (EO) condition. The focus was on beta band (12–30 Hz) activity, which is associated with motor control and proprioception. Results showed increased beta power during spaceflight when compared to pre-flight (EC: p < 0.01) and post-flight (EC: p < 0.01; EO: p < 0.05) conditions. FC strength also increased during spaceflight when compared to pre-flight (EO: p < 0.05) and post-flight (EC: p < 0.01; EO: p < 0.01) conditions. These differences were found primarily in the sensorimotor cortex (SMC) and frontotemporal regions, suggesting the brain’s adaptation to altered vestibular and proprioceptive inputs during microgravity. As these results reflect astronaut’s movement adaptation to microgravity, this study highlights the importance of understanding central nervous system (CNS) changes during spaceflights to ensure optimal performance and protect astronaut’s health during long-duration missions.


  • Open Access

    Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study

    by Amirreza Asayesh, Indhika Fauzhan Warsito, Jens Haueisen, Patrique Fiedler, Sampsa Vanhatalo

    This study investigates the feasibility of a dry electrode cap design for neonatal electroencephalogram (EEG) recordings. Recordings on a phantom and a real infant are compared between a novel dry electrode cap and a clinically used gel-based electrode cap. The phantom recordings included measuring both the electrode contact force and the signal quality during still and respiration-like head motion. The real infant recordings were assessed for the EEG signals’ spectral characteristics, including powerline interference. Compared to gel-based caps, the dry caps showed a largely comparable skin force, an expectedly greater sensitivity to motion-induced artifacts, and a slightly lower powerline interference. Recordings on the real infant showed no significant skin marks after using the dry electrode, and the spectral compositions were comparable between dry- and gel-based electrode caps. These findings suggest that neonatal EEG recordings with a dry electrode cap are technically feasible, but movement-related artifacts, such as respiration in a supine lying infant, may challenge long-term recordings of spontaneous EEG activity. Yet, the ease of use of dry electrode caps calls for future studies to define the optimal use case in neonatal recordings.


  • Open Access

    An Analytical Approach for Naturalistic Cooperative and Competitive EEG-Hyperscanning Data: A Proof-of-Concept Study

    by Gabriella Tamburro, Ricardo Bruña, Patrique Fiedler, Antonio De Fano, Khadijeh Raeisi, Mohammad Khazaei, Filippo Zappasodi, Silvia Comani

    Investigating the neural mechanisms underlying both cooperative and competitive joint actions may have a wide impact in many social contexts of human daily life. An effective pipeline of analysis for hyperscanning data recorded in a naturalistic context with a cooperative and competitive motor task has been missing. We propose an analytical pipeline for this type of joint action data, which was validated on electroencephalographic (EEG) signals recorded in a proof-of-concept study on two dyads playing cooperative and competitive table tennis. Functional connectivity maps were reconstructed using the corrected imaginary part of the phase locking value (ciPLV), an algorithm suitable in case of EEG signals recorded during turn-based competitive joint actions. Hyperbrain, within-, and between-brain functional connectivity maps were calculated in three frequency bands (i.e., theta, alpha, and beta) relevant during complex motor task execution and were characterized with graph theoretical measures and a clustering approach. The results of the proof-of-concept study are in line with recent findings on the main features of the functional networks sustaining cooperation and competition, hence demonstrating that the proposed pipeline is promising tool for the analysis of joint action EEG data recorded during cooperation and competition using a turn-based motor task.


  • Open Access

    Simultaneous Dry and Gel-Based High-Density Electroencephalography Recordings

    by Patrique Fiedler, Uwe Graichen, Ellen Zimmer, Jens Haueisen

    Evaluations of new dry, high-density EEG caps have only been performed so far with serial measurements and not with simultaneous (parallel) measurements. For a first comparison of gel-based and dry electrode performance in simultaneous high-density EEG measurements, we developed a new EEG cap comprising 64 gel-based and 64 dry electrodes and performed simultaneous measurements on ten volunteers. We analyzed electrode–skin impedances, resting state EEG, triggered eye blinks, and visual evoked potentials (VEPs). To overcome the issue of different electrode positions in the comparison of simultaneous measurements, we performed spatial frequency analysis of the simultaneously measured EEGs using spatial harmonic analysis (SPHARA). The impedances were 516 ± 429 kOhm (mean ± std) for the dry electrodes and 14 ± 8 kOhm for the gel-based electrodes. For the dry EEG electrodes, we obtained a channel reliability of 77%. We observed no differences between dry and gel-based recordings for the alpha peak frequency and the alpha power amplitude, as well as for the VEP peak amplitudes and latencies. For the VEP, the RMSD and the correlation coefficient between the gel-based and dry recordings were 1.7 ± 0.7 μV and 0.97 ± 0.03, respectively. We observed no differences in the cumulative power distributions of the spatial frequency components for the N75 and P100 VEP peaks. The differences for the N145 VEP peak were attributed to the different noise characteristics of gel-based and dry recordings. In conclusion, we provide evidence for the equivalence of simultaneous dry and gel-based high-density EEG measurements.