Ottorino Frezza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ottorino Frezza has a total of 465 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Biagioni
INFN Sezione di Roma 1, Roma
40 shared publications - Piero Vicini
INFN Sezione di Roma 1, Roma
40 shared publications - Roberto Ammendola
INFN Sezione di Roma 2, Roma
37 shared publications - Francesca Lo Cicero
INFN Sezione di Roma 1, Roma
33 shared publications - Francesco Simula
INFN Sezione di Roma 1, Roma
33 shared publications - Pier Stanislao Paolucci
Istituto Nazionale di Fisica Nucleare, Sezione di Roma, Rome, Italy
24 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , C06003
ALCOR, a mixed-signal ASIC for SiPM readout of the ePIC-dRICH detector at the EIC
ALCOR is a mixed-signal ASIC developed for the readout of silicon photomultiplier (SiPM) sensors in the ePIC dual-radiator RICH (dRICH) detector at the future Electron-Ion Collider (EIC). The current design integrates 32 channels in an 8×4 pixel array, providing high-precision timestamping with single-photon sensitivity, data-push architecture and fully digital output. Each channel features an analog front-end compatible with both signal polarities, comprising a low-impedance input stage, four selectable gain settings, and two leading-edge discriminators with independent 6-bit DAC thresholds. Precise timing is achieved by quad-buffered, low-power TDCs with analog interpolation and 20–40 ps time bin. Additional operating modes, including time-over-threshold and slew-rate, provide indirect amplitude measurements and effective time-walk correction. The power consumption of the full channel is 12 mW with default settings. Fabricated in 110 nm CMOS technology, ALCOR has been thoroughly validated in standalone operation and coupled with multiple SiPM models. Laboratory tests using single-photon laser pulses and HPK S13360 devices demonstrated an overall time resolution below 150 ps RMS. Two beam test campaigns at CERN-PS in 2023 and 2024, employing a dRICH prototype instrumented with 2048 3×3 mm 2 SiPMs read out by ALCOR, confirmed its suitability for ring-imaging and particle-identification. A new version of the ASIC, named ALCOR-64, was designed and submitted for fabrication in April 2025. This version doubles the channel count to 64, integrates the ASIC in a ball grid array package and addresses specific EIC-driven requirements, including a programmable-width hardware shutter to inhibit events digitization and thus suppress the SiPM out-of-time DCR-induced background.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , C06003
Open AccessALCOR, a mixed-signal ASIC for SiPM readout of the ePIC-dRICH detector at the EIC
ALCOR is a mixed-signal ASIC developed for the readout of silicon photomultiplier (SiPM) sensors in the ePIC dual-radiator RICH (dRICH) detector at the future Electron-Ion Collider (EIC). The current design integrates 32 channels in an 8×4 pixel array, providing high-precision timestamping with single-photon sensitivity, data-push architecture and fully digital output. Each channel features an analog front-end compatible with both signal polarities, comprising a low-impedance input stage, four selectable gain settings, and two leading-edge discriminators with independent 6-bit DAC thresholds. Precise timing is achieved by quad-buffered, low-power TDCs with analog interpolation and 20–40 ps time bin. Additional operating modes, including time-over-threshold and slew-rate, provide indirect amplitude measurements and effective time-walk correction. The power consumption of the full channel is 12 mW with default settings. Fabricated in 110 nm CMOS technology, ALCOR has been thoroughly validated in standalone operation and coupled with multiple SiPM models. Laboratory tests using single-photon laser pulses and HPK S13360 devices demonstrated an overall time resolution below 150 ps RMS. Two beam test campaigns at CERN-PS in 2023 and 2024, employing a dRICH prototype instrumented with 2048 3×3 mm 2 SiPMs read out by ALCOR, confirmed its suitability for ring-imaging and particle-identification. A new version of the ASIC, named ALCOR-64, was designed and submitted for fabrication in April 2025. This version doubles the channel count to 64, integrates the ASIC in a ball grid array package and addresses specific EIC-driven requirements, including a programmable-width hardware shutter to inhibit events digitization and thus suppress the SiPM out-of-time DCR-induced background.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04039
Radiation tolerance tests on key components of the ePIC-dRICH readout card
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04039
Open AccessRadiation tolerance tests on key components of the ePIC-dRICH readout card
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01031
The SiPM readout plane for the ePIC-dRICH photo-detector at the EIC: overview and beam test results
The dual-radiator (dRICH) detector of the ePIC experiment at the future Electron-Ion Collider (EIC) will make use of SiPM sensors for the detection of the emitted Cherenkov light. The photo-detector will cover ∼3 m 2 with 3×3 mm 2 pixels, for a total of more than 300000 readout channels, and will be the first application of SiPMs for single-photon detection in a collider experiment. SiPMs are chosen for their low cost and high photon detection efficiency, which remains unaffected even in the presence of a high magnetic field. However, since they are not radiation-hard, careful attention is required to preserve their single-photon counting capabilities and to keep the dark count rate (DCR) under control throughout the years of operation of the ePIC experiment. DCR control can be achieved by operating SiPMs at low temperatures and by recovering radiation damage through high-temperature annealing cycles. We present an overview of the ePIC-dRICH photo-detector system. Special focus is given to development and beam test results of a large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm 2 sensors. The photo-detector prototype is modular and based on a novel EIC-driven photo-detection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5×5×14 cm 3 . The prototype has been successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. Results on ring images reconstructed, beam momentum scan and particle identification using the dual radiator configuration are presented. In addition, studies on radiation-induced defects using emission microscopy, and on annealing cycles used to recover radiation damage, are shown.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01031
Open AccessThe SiPM readout plane for the ePIC-dRICH photo-detector at the EIC: overview and beam test results
The dual-radiator (dRICH) detector of the ePIC experiment at the future Electron-Ion Collider (EIC) will make use of SiPM sensors for the detection of the emitted Cherenkov light. The photo-detector will cover ∼3 m 2 with 3×3 mm 2 pixels, for a total of more than 300000 readout channels, and will be the first application of SiPMs for single-photon detection in a collider experiment. SiPMs are chosen for their low cost and high photon detection efficiency, which remains unaffected even in the presence of a high magnetic field. However, since they are not radiation-hard, careful attention is required to preserve their single-photon counting capabilities and to keep the dark count rate (DCR) under control throughout the years of operation of the ePIC experiment. DCR control can be achieved by operating SiPMs at low temperatures and by recovering radiation damage through high-temperature annealing cycles. We present an overview of the ePIC-dRICH photo-detector system. Special focus is given to development and beam test results of a large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm 2 sensors. The photo-detector prototype is modular and based on a novel EIC-driven photo-detection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5×5×14 cm 3 . The prototype has been successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. Results on ring images reconstructed, beam momentum scan and particle identification using the dual radiator configuration are presented. In addition, studies on radiation-induced defects using emission microscopy, and on annealing cycles used to recover radiation damage, are shown.
- Open Access
- 27 December 2025
- Published by Elsevier in Physics Letters B
- Vol. 872
Search for heavy neutral leptons in π + decays to positrons
- 27 December 2025
- Published by Elsevier in Physics Letters B
- Vol. 872
Open AccessSearch for heavy neutral leptons in π + decays to positrons
- Open Access
- 24 November 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (11) , 143
Searches for hidden sectors using K+ → π+X decays
A bstract: Results from the study of the rare decays $$ {K}^{+}\to {\pi}^{+}\nu \overline{\nu} $$ , K + → π + μ + μ − and K + → π + γγ at the NA62 experiment at CERN are interpreted in terms of improved limits for $$ \mathcal{B}\left({K}^{+}\to {\pi}^{+}X\right) $$ and coupling parameters of hidden-sector models, where X is a mediator. World-leading limits are achieved for dark photon, dark scalar and axion-like particle models.- 24 November 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (11) , 143
Open AccessSearches for hidden sectors using K+ → π+X decays
A bstract: Results from the study of the rare decays $$ {K}^{+}\to {\pi}^{+}\nu \overline{\nu} $$ , K + → π + μ + μ − and K + → π + γγ at the NA62 experiment at CERN are interpreted in terms of improved limits for $$ \mathcal{B}\left({K}^{+}\to {\pi}^{+}X\right) $$ and coupling parameters of hidden-sector models, where X is a mediator. World-leading limits are achieved for dark photon, dark scalar and axion-like particle models. - Open Access
- 15 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 2068-2076
Bridging FPGA and GPU over PCIe: A Low-Latency Communication Path using AVX-512
- 15 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 2068-2076
Open AccessBridging FPGA and GPU over PCIe: A Low-Latency Communication Path using AVX-512
- Open Access
- 7 October 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 337, 01252
The new hardware trigger processor at NA62 experiment: Status of the System and First Results
The NA62 experiment is designed to study rare and ultra-rare kaon decays using a decay-in-flight technique. The Trigger and Data Acquisition (TDAQ) system of NA62 is multi-level, making it critically dependent on the performance of the inter-level network. To manage the huge amount of data produced by the detectors, three levels of triggers are employed. The first level L0TP, implemented using an FPGA device, has been in operation since the start of data taking in 2016. In order to increase the efficiency of the system and implement additional algorithms, an upgraded system (L0TP+) was developed starting in 2018. This upgrade avails itself of a high-end FPGA available on the market, offering more computing power, larger local memory and higher transmission bandwidth. We have planned tests for a new trigger algorithm that implements quadrant-based logic for the veto systems. This new approach is expected to improve the main trigger efficiency by several percent. Extensive tests were conducted using a parasitic setup that included a set of Network TAPs and a commodity server, allowing for proficient comparison of trigger decisions on an event-by-event basis. The experience gained from this parasitic mode operation can be leveraged for the next data-taking period as a development setup to implement additional features, thereby accelerating the TDAQ upgrade. After the testing period, the new system has been adopted as the online processor since 2023. Preliminary results on the efficiency of the new system will be reported. Integration with the new AI-based FPGA-RICH system, which performs online partial particle identification, will also be discussed.
- 7 October 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 337, 01252
Open AccessThe new hardware trigger processor at NA62 experiment: Status of the System and First Results
The NA62 experiment is designed to study rare and ultra-rare kaon decays using a decay-in-flight technique. The Trigger and Data Acquisition (TDAQ) system of NA62 is multi-level, making it critically dependent on the performance of the inter-level network. To manage the huge amount of data produced by the detectors, three levels of triggers are employed. The first level L0TP, implemented using an FPGA device, has been in operation since the start of data taking in 2016. In order to increase the efficiency of the system and implement additional algorithms, an upgraded system (L0TP+) was developed starting in 2018. This upgrade avails itself of a high-end FPGA available on the market, offering more computing power, larger local memory and higher transmission bandwidth. We have planned tests for a new trigger algorithm that implements quadrant-based logic for the veto systems. This new approach is expected to improve the main trigger efficiency by several percent. Extensive tests were conducted using a parasitic setup that included a set of Network TAPs and a commodity server, allowing for proficient comparison of trigger decisions on an event-by-event basis. The experience gained from this parasitic mode operation can be leveraged for the next data-taking period as a development setup to implement additional features, thereby accelerating the TDAQ upgrade. After the testing period, the new system has been adopted as the online processor since 2023. Preliminary results on the efficiency of the new system will be reported. Integration with the new AI-based FPGA-RICH system, which performs online partial particle identification, will also be discussed.
- Open Access
- 25 May 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (5) , 1-12
Search for hadronic decays of feebly-interacting particles at NA62
The NA62 experiment at CERN has the capability to collect data in a beam-dump mode, where 400 GeV protons are dumped on an absorber. In this configuration, New Physics particles, including dark photons, dark scalars, and axion-like particles, may be produced in the absorber and decay in the instrumented volume beginning approximately 80 m downstream of the dump. A search for these particles decaying in flight to hadronic final states is reported, based on an analysis of a sample of $$1.4 \times 10^{17}$$ protons on dump collected in 2021. No evidence of a New Physics signal is observed, excluding new regions of parameter spaces of multiple models.- 25 May 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (5) , 1-12
Open AccessSearch for hadronic decays of feebly-interacting particles at NA62
The NA62 experiment at CERN has the capability to collect data in a beam-dump mode, where 400 GeV protons are dumped on an absorber. In this configuration, New Physics particles, including dark photons, dark scalars, and axion-like particles, may be produced in the absorber and decay in the instrumented volume beginning approximately 80 m downstream of the dump. A search for these particles decaying in flight to hadronic final states is reported, based on an analysis of a sample of $$1.4 \times 10^{17}$$ protons on dump collected in 2021. No evidence of a New Physics signal is observed, excluding new regions of parameter spaces of multiple models.