Craig A. Robertson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Craig A. Robertson has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Celestine Santosh
Institute of Neurological Sciences, Southern General Hospital, Glasgow, UK
4 shared publicationsChristopher McCabe
Centre for Stroke and Brain Imaging Research, Institute of Neuroscience and Psychology, College of Medicine, Veterinary & Life Sciences, University of Glasgow, Glasgow, UK
4 shared publicationsI Mhairi Macrae
Glasgow Experimental MRI Centre, Institute of Neuroscience and Psychology, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, UK
3 shared publicationsWilliam M Holmes
Glasgow Experimental MRI Centre, Institute of Neuroscience and Psychology, University of Glasgow, Glasgow, UK
3 shared publicationsBarrie Condon
Institute of Neurological Sciences, Southern General Hospital, Glasgow, UK
2 shared publicationsKeith W Muir
Institute of Neuroscience and Psychology, University of Glasgow, Institute of Neurological Sciences, Southern General Hospital, Glasgow, UK
2 shared publications
Latest Publications
- Open Access
- 12 September 2018
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 5 (6) , 681-698
Structure determination and crystal chemistry of large repeat mixed-layer hexaferrites
Hexaferrites are an important class of magnetic oxides with applications in data storage and electronics. Their crystal structures are highly modular, consisting of Fe- or Ba-rich close-packed blocks that can be stacked in different sequences to form a multitude of unique structures, producing large anisotropic unit cells with lattice parameters typically >100 Å along the stacking axis. This has limited atomic-resolution structure solutions to relatively simple examples such as Ba2Zn2Fe12O22, whilst longer stacking sequences have been modelled only in terms of block sequences, with no refinement of individual atomic coordinates or occupancies. This paper describes the growth of a series of complex hexaferrite crystals, their atomic-level structure solution by high-resolution synchrotron X-ray diffraction, electron diffraction and imaging methods, and their physical characterization by magnetometry. The structures include a new hexaferrite stacking sequence, with the longest lattice parameter of any hexaferrite with a fully determined structure.
- 12 September 2018
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 5 (6) , 681-698
Open AccessStructure determination and crystal chemistry of large repeat mixed-layer hexaferrites
Hexaferrites are an important class of magnetic oxides with applications in data storage and electronics. Their crystal structures are highly modular, consisting of Fe- or Ba-rich close-packed blocks that can be stacked in different sequences to form a multitude of unique structures, producing large anisotropic unit cells with lattice parameters typically >100 Å along the stacking axis. This has limited atomic-resolution structure solutions to relatively simple examples such as Ba2Zn2Fe12O22, whilst longer stacking sequences have been modelled only in terms of block sequences, with no refinement of individual atomic coordinates or occupancies. This paper describes the growth of a series of complex hexaferrite crystals, their atomic-level structure solution by high-resolution synchrotron X-ray diffraction, electron diffraction and imaging methods, and their physical characterization by magnetometry. The structures include a new hexaferrite stacking sequence, with the longest lattice parameter of any hexaferrite with a fully determined structure.
- Open Access
- 26 October 2017
- Published by BMJ in Journal of the Royal Army Medical Corps
- Vol. 164 (2) , 96-102
Development of a portable blood salvage and autotransfusion technology to enhance survivability of personnel requiring major medical interventions in austere or military environments
Introduction Uncontrolled haemorrhage is the leading cause of death on the battlefield, and two-thirds of these deaths result from non-compressible haemorrhage. Blood salvage and autotransfusion represent an alternative to conventional blood transfusion techniques for austere environments, potentially providing blood to the casualty at point of injury. The aim of this paper is to describe the design, development and initial proof-of-concept testing of a portable blood salvage and autotransfusion technology to enhance survivability of personnel requiring major medical interventions in austere or military environments. Method A manually operable, dual-headed pump was developed that removes blood from site of injury to a collection reservoir (upper pump) and back to casualty (lower pump). Theoretical flow rate calculations determined pump configuration and a three-dimensionally printed peristaltic pump was manufactured. Flow rates were tested with fresh bovine blood under laboratory conditions representative of the predicted clinical environment. Results Mathematical modelling suggested flow rates of 3.6 L/min and 0.57 L/min for upper and lower pumps. Using fresh bovine blood, flow rates produced were 2.67 L/min and 0.43 L/min. To mimic expected battlefield conditions, upper suction pump flow rate was calculated using a blood/air mixture. Conclusion The authors believe that this technology can potentially enhance survivability for casualties in austere and deployed military settings through autotransfusion and cell concentration. It reduces negative effects of blood donation on the conventional donor pool, and potentially negates the logistical constraints associated with allogenic transfusions.
- 26 October 2017
- Published by BMJ in Journal of the Royal Army Medical Corps
- Vol. 164 (2) , 96-102
Open AccessDevelopment of a portable blood salvage and autotransfusion technology to enhance survivability of personnel requiring major medical interventions in austere or military environments
Introduction Uncontrolled haemorrhage is the leading cause of death on the battlefield, and two-thirds of these deaths result from non-compressible haemorrhage. Blood salvage and autotransfusion represent an alternative to conventional blood transfusion techniques for austere environments, potentially providing blood to the casualty at point of injury. The aim of this paper is to describe the design, development and initial proof-of-concept testing of a portable blood salvage and autotransfusion technology to enhance survivability of personnel requiring major medical interventions in austere or military environments. Method A manually operable, dual-headed pump was developed that removes blood from site of injury to a collection reservoir (upper pump) and back to casualty (lower pump). Theoretical flow rate calculations determined pump configuration and a three-dimensionally printed peristaltic pump was manufactured. Flow rates were tested with fresh bovine blood under laboratory conditions representative of the predicted clinical environment. Results Mathematical modelling suggested flow rates of 3.6 L/min and 0.57 L/min for upper and lower pumps. Using fresh bovine blood, flow rates produced were 2.67 L/min and 0.43 L/min. To mimic expected battlefield conditions, upper suction pump flow rate was calculated using a blood/air mixture. Conclusion The authors believe that this technology can potentially enhance survivability for casualties in austere and deployed military settings through autotransfusion and cell concentration. It reduces negative effects of blood donation on the conventional donor pool, and potentially negates the logistical constraints associated with allogenic transfusions.
- Open Access
- 24 September 2016
- Published by SAGE Publications in Perfusion
- Vol. 32 (2) , 126-132
Development of a diagnostic sensor for measuring blood cell concentrations during haemoconcentration
Background: HemoSep® is a commercial ultrafiltration and haemoconcentration device for the concentration of residual bypass blood following surgery. This technology is capable of reducing blood loss in cardiac and other types of “clean site” procedures, including paediatric surgery. Clinical feedback suggested that the device would be enhanced by including a sensor technology capable of discerning the concentration level of the processed blood product. We sought to develop a novel sensor that can, using light absorption, give an accurate estimate of packed cell volume (PCV). Materials and methods: A sensor-housing unit was 3D printed and the factors influencing the sensor’s effectiveness – supply voltage, sensitivity and emitter intensity - were optimised. We developed a smart system, using comparator circuitry capable of visually informing the user when adequate PCV levels (⩾35%) are attained by HemoSep® blood processing, which ultimately indicates that the blood is ready for autotransfusion. Results: Our data demonstrated that the device was capable of identifying blood concentration at and beyond the 35% PCV level. The device was found to be 100% accurate at identifying concentration levels of 35% from a starting level of 20%. Discussion: The sensory capability was integrated into HemoSep’s® current device and is designed to enhance the user’s clinical experience and to optimise the benefits of HemoSep® therapy. The present study focused on laboratory studies using bovine blood. Further studies are now planned in the clinical setting to confirm the efficacy of the device.
- 24 September 2016
- Published by SAGE Publications in Perfusion
- Vol. 32 (2) , 126-132
Open AccessDevelopment of a diagnostic sensor for measuring blood cell concentrations during haemoconcentration
Background: HemoSep® is a commercial ultrafiltration and haemoconcentration device for the concentration of residual bypass blood following surgery. This technology is capable of reducing blood loss in cardiac and other types of “clean site” procedures, including paediatric surgery. Clinical feedback suggested that the device would be enhanced by including a sensor technology capable of discerning the concentration level of the processed blood product. We sought to develop a novel sensor that can, using light absorption, give an accurate estimate of packed cell volume (PCV). Materials and methods: A sensor-housing unit was 3D printed and the factors influencing the sensor’s effectiveness – supply voltage, sensitivity and emitter intensity - were optimised. We developed a smart system, using comparator circuitry capable of visually informing the user when adequate PCV levels (⩾35%) are attained by HemoSep® blood processing, which ultimately indicates that the blood is ready for autotransfusion. Results: Our data demonstrated that the device was capable of identifying blood concentration at and beyond the 35% PCV level. The device was found to be 100% accurate at identifying concentration levels of 35% from a starting level of 20%. Discussion: The sensory capability was integrated into HemoSep’s® current device and is designed to enhance the user’s clinical experience and to optimise the benefits of HemoSep® therapy. The present study focused on laboratory studies using bovine blood. Further studies are now planned in the clinical setting to confirm the efficacy of the device.
- Open Access
- 15 July 2014
- Published by SAGE Publications in International Journal of Stroke
- Vol. 10 (1) , 42-50
Detection of Ischemic Penumbra Using Combined Perfusion and T2* Oxygen Challenge Imaging
Background: Acute ischemic stroke is common and disabling, but there remains a paucity of acute treatment options and available treatment (thrombolysis) is underutilized. Advanced brain imaging, designed to identify viable hypoperfused tissue (penumbra), could target treatment to a wider population. Existing magnetic resonance imaging and computed tomography-based technologies are not widely used pending validation in ongoing clinical trials. T2* oxygen challenge magnetic resonance imaging, by providing a more direct readout of tissue viability, has the potential to identify more patients likely to benefit from thrombolysis – irrespective of time from stroke onset – and patients within and beyond the 4·5 h thrombolysis treatment window who are unlikely to benefit and are at an increased risk of hemorrhage. Aims: This study employs serial multimodal imaging and voxel-based analysis to develop optimal data processing for T2* oxygen challenge penumbra assessment. Tissue in the ischemic hemisphere is compartmentalized into penumbra, ischemic core, or normal using T2* oxygen challenge (single threshold) or T2* oxygen challenge plus cerebral blood flow (dual threshold) data. Penumbra defined by perfusion imaging/apparent diffusion coefficient mismatch (dual threshold) is included for comparison. Methods: Permanent middle cerebral artery occlusion was induced in male Sprague-Dawley rats ( n = 6) prior to serial multimodal imaging: T2* oxygen challenge, diffusion-weighted and perfusion imaging (cerebral blood flow using arterial spin labeling). Results: Across the different methods evaluated, T2* oxygen challenge combined with perfusion imaging most closely predicted 24 h infarct volume. Penumbra volume declined from one to four-hours post-stroke: mean ± SD, 77 ± 44 to 49 ± 37 mm3 (single T2* oxygen challenge-based threshold); 55 ± 41 to 37 ± 12 mm3 (dual T2* oxygen challenge/cerebral blood flow); 84 ± 64 to 42 ± 18 mm3 (dual cerebral blood flow/apparent diffusion coefficient), as ischemic core grew: 155 ± 37 to 211 ± 36 mm3 (single apparent diffusion coefficient threshold); 178 ± 56 to 205 ± 33 mm3 (dual T2* oxygen challenge/cerebral blood flow); 139 ± 30 to 168 ± 38 mm3 (dual cerebral blood flow/apparent diffusion coefficient). There was evidence of further lesion growth beyond four-hours (T2-defined edema-corrected infarct, 231 ± 19 mm3). Conclusions: In conclusion, T2* oxygen challenge combined with perfusion imaging has advantages over alternative magnetic resonance imaging techniques for penumbra detection by providing serial assessment of available penumbra based on tissue viability.
- 15 July 2014
- Published by SAGE Publications in International Journal of Stroke
- Vol. 10 (1) , 42-50
Open AccessDetection of Ischemic Penumbra Using Combined Perfusion and T2* Oxygen Challenge Imaging
Background: Acute ischemic stroke is common and disabling, but there remains a paucity of acute treatment options and available treatment (thrombolysis) is underutilized. Advanced brain imaging, designed to identify viable hypoperfused tissue (penumbra), could target treatment to a wider population. Existing magnetic resonance imaging and computed tomography-based technologies are not widely used pending validation in ongoing clinical trials. T2* oxygen challenge magnetic resonance imaging, by providing a more direct readout of tissue viability, has the potential to identify more patients likely to benefit from thrombolysis – irrespective of time from stroke onset – and patients within and beyond the 4·5 h thrombolysis treatment window who are unlikely to benefit and are at an increased risk of hemorrhage. Aims: This study employs serial multimodal imaging and voxel-based analysis to develop optimal data processing for T2* oxygen challenge penumbra assessment. Tissue in the ischemic hemisphere is compartmentalized into penumbra, ischemic core, or normal using T2* oxygen challenge (single threshold) or T2* oxygen challenge plus cerebral blood flow (dual threshold) data. Penumbra defined by perfusion imaging/apparent diffusion coefficient mismatch (dual threshold) is included for comparison. Methods: Permanent middle cerebral artery occlusion was induced in male Sprague-Dawley rats ( n = 6) prior to serial multimodal imaging: T2* oxygen challenge, diffusion-weighted and perfusion imaging (cerebral blood flow using arterial spin labeling). Results: Across the different methods evaluated, T2* oxygen challenge combined with perfusion imaging most closely predicted 24 h infarct volume. Penumbra volume declined from one to four-hours post-stroke: mean ± SD, 77 ± 44 to 49 ± 37 mm3 (single T2* oxygen challenge-based threshold); 55 ± 41 to 37 ± 12 mm3 (dual T2* oxygen challenge/cerebral blood flow); 84 ± 64 to 42 ± 18 mm3 (dual cerebral blood flow/apparent diffusion coefficient), as ischemic core grew: 155 ± 37 to 211 ± 36 mm3 (single apparent diffusion coefficient threshold); 178 ± 56 to 205 ± 33 mm3 (dual T2* oxygen challenge/cerebral blood flow); 139 ± 30 to 168 ± 38 mm3 (dual cerebral blood flow/apparent diffusion coefficient). There was evidence of further lesion growth beyond four-hours (T2-defined edema-corrected infarct, 231 ± 19 mm3). Conclusions: In conclusion, T2* oxygen challenge combined with perfusion imaging has advantages over alternative magnetic resonance imaging techniques for penumbra detection by providing serial assessment of available penumbra based on tissue viability.
- Open Access
- 11 May 2011
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 31 (8) , 1788-1798
Stroke Penumbra Defined by an MRI-Based Oxygen Challenge Technique: 2. Validation based on the Consequences of Reperfusion
Magnetic resonance imaging (MRI) with oxygen challenge (T*2 OC) uses oxygen as a metabolic biotracer to define penumbral tissue based on CMRO2 and oxygen extraction fraction. Penumbra displays a greater T*2 signal change during OC than surrounding tissue. Since timely restoration of cerebral blood flow (CBF) should salvage penumbra, T*2 OC was tested by examining the consequences of reperfusion on T*2 OC-defined penumbra. Transient ischemia (109 ± 20 minutes) was induced in male Sprague-Dawley rats ( n = 8). Penumbra was identified on T*2-weighted MRI during OC. Ischemia and ischemic injury were identified on CBF and apparent diffusion coefficient maps, respectively. Reperfusion was induced and scans repeated. T2 for final infarct and T*2 OC were run on day 7. T*2 signal increase to OC was 3.4% in contralateral cortex and caudate nucleus and was unaffected by reperfusion. In OC-defined penumbra, T*2 signal increased by 8.4% ± 4.1% during ischemia and returned to 3.25% ± 0.8% following reperfusion. Ischemic core T*2 signal increase was 0.39% ± 0.47% during ischemia and 0.84% ± 1.8% on reperfusion. Penumbral CBF increased from 41.94 ± 13 to 116.5 ± 25 mL per 100 g per minute on reperfusion. On day 7, OC-defined penumbra gave a normal OC response and was located outside the infarct. T*2 OC-defined penumbra recovered when CBF was restored, providing further validation of the utility of T*2 OC for acute stroke management.
- 11 May 2011
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 31 (8) , 1788-1798
Open AccessStroke Penumbra Defined by an MRI-Based Oxygen Challenge Technique: 2. Validation based on the Consequences of Reperfusion
Magnetic resonance imaging (MRI) with oxygen challenge (T*2 OC) uses oxygen as a metabolic biotracer to define penumbral tissue based on CMRO2 and oxygen extraction fraction. Penumbra displays a greater T*2 signal change during OC than surrounding tissue. Since timely restoration of cerebral blood flow (CBF) should salvage penumbra, T*2 OC was tested by examining the consequences of reperfusion on T*2 OC-defined penumbra. Transient ischemia (109 ± 20 minutes) was induced in male Sprague-Dawley rats ( n = 8). Penumbra was identified on T*2-weighted MRI during OC. Ischemia and ischemic injury were identified on CBF and apparent diffusion coefficient maps, respectively. Reperfusion was induced and scans repeated. T2 for final infarct and T*2 OC were run on day 7. T*2 signal increase to OC was 3.4% in contralateral cortex and caudate nucleus and was unaffected by reperfusion. In OC-defined penumbra, T*2 signal increased by 8.4% ± 4.1% during ischemia and returned to 3.25% ± 0.8% following reperfusion. Ischemic core T*2 signal increase was 0.39% ± 0.47% during ischemia and 0.84% ± 1.8% on reperfusion. Penumbral CBF increased from 41.94 ± 13 to 116.5 ± 25 mL per 100 g per minute on reperfusion. On day 7, OC-defined penumbra gave a normal OC response and was located outside the infarct. T*2 OC-defined penumbra recovered when CBF was restored, providing further validation of the utility of T*2 OC for acute stroke management.
- Open Access
- 11 May 2011
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 31 (8) , 1778-1787
Stroke Penumbra Defined by an MRI-Based Oxygen Challenge Technique: 1. Validation using [14C]2-Deoxyglucose Autoradiography
Accurate identification of ischemic penumbra will improve stroke patient selection for reperfusion therapies and clinical trials. Current magnetic resonance imaging (MRI) techniques have limitations and lack validation. Oxygen challenge T*2 MRI (T*2 OC) uses oxygen as a biotracer to detect tissue metabolism, with penumbra displaying the greatest T*2 signal change during OC. [14C]2-deoxyglucose (2-DG) autoradiography was combined with T*2 OC to determine metabolic status of T*2-defined penumbra. Permanent middle cerebral artery occlusion was induced in anesthetized male Sprague-Dawley rats ( n = 6). Ischemic injury and perfusion deficit were determined by diffusion- and perfusion-weighted imaging, respectively. At 147 ± 32 minutes after stroke, T*2 signal change was measured during a 5-minute 100% OC, immediately followed by 125 μCi/kg 2-DG, intravenously. Magnetic resonance images were coregistered with the corresponding autoradiograms. Regions of interest were located within ischemic core, T*2-defined penumbra, equivalent contralateral structures, and a region of hyperglycolysis. A T*2 signal increase of 9.22% ± 3.9% (mean ± s.d.) was recorded in presumed penumbra, which displayed local cerebral glucose utilization values equivalent to contralateral cortex. T*2 signal change was negligible in ischemic core, 3.2% ± 0.78% in contralateral regions, and 1.41% ± 0.62% in hyperglycolytic tissue, located outside OC-defined penumbra and within the diffusion abnormality. The results support the utility of OC-MRI to detect viable penumbral tissue following stroke.
- 11 May 2011
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 31 (8) , 1778-1787
Open AccessStroke Penumbra Defined by an MRI-Based Oxygen Challenge Technique: 1. Validation using [14C]2-Deoxyglucose Autoradiography
Accurate identification of ischemic penumbra will improve stroke patient selection for reperfusion therapies and clinical trials. Current magnetic resonance imaging (MRI) techniques have limitations and lack validation. Oxygen challenge T*2 MRI (T*2 OC) uses oxygen as a biotracer to detect tissue metabolism, with penumbra displaying the greatest T*2 signal change during OC. [14C]2-deoxyglucose (2-DG) autoradiography was combined with T*2 OC to determine metabolic status of T*2-defined penumbra. Permanent middle cerebral artery occlusion was induced in anesthetized male Sprague-Dawley rats ( n = 6). Ischemic injury and perfusion deficit were determined by diffusion- and perfusion-weighted imaging, respectively. At 147 ± 32 minutes after stroke, T*2 signal change was measured during a 5-minute 100% OC, immediately followed by 125 μCi/kg 2-DG, intravenously. Magnetic resonance images were coregistered with the corresponding autoradiograms. Regions of interest were located within ischemic core, T*2-defined penumbra, equivalent contralateral structures, and a region of hyperglycolysis. A T*2 signal increase of 9.22% ± 3.9% (mean ± s.d.) was recorded in presumed penumbra, which displayed local cerebral glucose utilization values equivalent to contralateral cortex. T*2 signal change was negligible in ischemic core, 3.2% ± 0.78% in contralateral regions, and 1.41% ± 0.62% in hyperglycolytic tissue, located outside OC-defined penumbra and within the diffusion abnormality. The results support the utility of OC-MRI to detect viable penumbral tissue following stroke.
- Open Access
- 11 May 2011
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 31 (8) , 1799-1806
Influence of 100% and 40% Oxygen on Penumbral Blood Flow, Oxygen Level, and T*2-Weighted MRI in a Rat Stroke Model
Accurate imaging of the ischemic penumbra is a prerequisite for acute clinical stroke research. T*2 magnetic resonance imaging (MRI) combined with an oxygen challenge (OC) is being developed to detect penumbra based on changes in blood deoxyhemoglobin. However, inducing OC with 100% O2 induces sinus artefacts on human scans and influences cerebral blood flow (CBF), which can affect T*2 signal. Therefore, we investigated replacing 100% O2 OC with 40% O2 OC (5 minutes 40% O2 versus 100% O2) and determined the effects on blood pressure (BP), CBF, tissue pO2, and T*2 signal change in presumed penumbra in a rat stroke model. Probes implanted into penumbra and contralateral cortex simultaneously recorded pO2 and CBF during 40% O2 ( n = 6) or 100% O2 ( n = 8) OC. In a separate MRI study, T*2 signal change to 40% O2 ( n = 6) and 100% O2 ( n = 5) OC was compared. Oxygen challenge (40% and 100% O2) increased BP by 8.2% and 18.1%, penumbra CBF by 5% and 15%, and penumbra pO2 levels by 80% and 144%, respectively. T*2 signal significantly increased by 4.56% ± 1.61% and 8.65% ± 3.66% in penumbra compared with 2.98% ± 1.56% and 2.79% ± 0.66% in contralateral cortex and 1.09% ± 0.82% and −0.32% ± 0.67% in ischemic core, respectively. For diagnostic imaging, 40% O2 OC could provide sufficient T*2 signal change to detect penumbra with limited influence in BP and CBF.
- 11 May 2011
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 31 (8) , 1799-1806
Open AccessInfluence of 100% and 40% Oxygen on Penumbral Blood Flow, Oxygen Level, and T*2-Weighted MRI in a Rat Stroke Model
Accurate imaging of the ischemic penumbra is a prerequisite for acute clinical stroke research. T*2 magnetic resonance imaging (MRI) combined with an oxygen challenge (OC) is being developed to detect penumbra based on changes in blood deoxyhemoglobin. However, inducing OC with 100% O2 induces sinus artefacts on human scans and influences cerebral blood flow (CBF), which can affect T*2 signal. Therefore, we investigated replacing 100% O2 OC with 40% O2 OC (5 minutes 40% O2 versus 100% O2) and determined the effects on blood pressure (BP), CBF, tissue pO2, and T*2 signal change in presumed penumbra in a rat stroke model. Probes implanted into penumbra and contralateral cortex simultaneously recorded pO2 and CBF during 40% O2 ( n = 6) or 100% O2 ( n = 8) OC. In a separate MRI study, T*2 signal change to 40% O2 ( n = 6) and 100% O2 ( n = 5) OC was compared. Oxygen challenge (40% and 100% O2) increased BP by 8.2% and 18.1%, penumbra CBF by 5% and 15%, and penumbra pO2 levels by 80% and 144%, respectively. T*2 signal significantly increased by 4.56% ± 1.61% and 8.65% ± 3.66% in penumbra compared with 2.98% ± 1.56% and 2.79% ± 0.66% in contralateral cortex and 1.09% ± 0.82% and −0.32% ± 0.67% in ischemic core, respectively. For diagnostic imaging, 40% O2 OC could provide sufficient T*2 signal change to detect penumbra with limited influence in BP and CBF.