Alina Beraudi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alina Beraudi has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Susanna Stea
Medical Technology Laboratory, Rizzoli Orthopedic Institute, Bologna, Italy
10 shared publications Aldo Toni
Medical Technology Laboratory, Rizzoli Orthopaedic Institute, Bologna - Italy
5 shared publicationsAlessandro Poli
Department of Biology, University of Bologna, 40126 Bologna, Italy
5 shared publications- Monica Montesi
Institute of Science, Technology and Sustainability for Ceramics (ISSMC), National Research Council of Italy, Via Granarolo 64, Faenza, 48018, Italy
5 shared publications - Barbara Bordini
Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
4 shared publications Francesco Traina
3 shared publications
Latest Publications
- 24 March 2014
- Published by SAGE Publications in HIP International
- Vol. 24 (4) , 321-326
Metal Ion Release: Also a Concern for Ceramic-on-Ceramic Couplings?
BIOLOX® delta is the newest ceramic composite material of the BIOLOX® family and its use in hip devices represents a good alternative to Metal-on-Metal or Metal-on-Polyethylene coupling. Some Metal-on-Metal hip devices have shown chromium and cobalt release, which promoted toxic effects. Furthermore, the ceramic composite contains trivalent chromium, even if strongly bound to the alumina lattice. The present study is aimed at detecting any ‘in vivo’ release of chromium ions from BIOLOX® delta bearings in the blood, erythrocytes and urine of patients. Twenty patients implanted with total hip arthroplasty (THA) with BIOLOX® delta-BIOLOX® delta couplings and 21 subjects with no implanted prostheses were studied. Inductively coupled plasma mass spectrometry equipped with dynamic reaction cell was used for analysis. In the THA group the Cr ions values were; in blood mean 0.21 µg/l (±0.09), in serum 0.21 µg/l (±0.12), in normalized erythrocytes 0.13 µg/l (±0.09), in normalized urine 0.12 µg/g creatinine (±0.13). In the control group the Cr ions values were; in blood mean 0.22 µg/l (st dev 0.14), in serum 0.17 µg/l (±0.08), in normalized erythrocytes 0.13 µg/l (±0.11), in normalized urine 0.07 µg/g creatinine (±0.08). The Lab reference values were 0.1-5.0 µg/l for blood, 0.1-0.5 µg/l for serum, 0.14-4.58 µg/l for normalised erythrocytes and 0.05-2.2 µg/l for urine. All samples in both groups resulted in chromium levels within the normal reference range and the safety of BIOLOX® delta ceramics, in terms of chromium ions release, has been demonstrated.
- 24 March 2014
- Published by SAGE Publications in HIP International
- Vol. 24 (4) , 321-326
Metal Ion Release: Also a Concern for Ceramic-on-Ceramic Couplings?
BIOLOX® delta is the newest ceramic composite material of the BIOLOX® family and its use in hip devices represents a good alternative to Metal-on-Metal or Metal-on-Polyethylene coupling. Some Metal-on-Metal hip devices have shown chromium and cobalt release, which promoted toxic effects. Furthermore, the ceramic composite contains trivalent chromium, even if strongly bound to the alumina lattice. The present study is aimed at detecting any ‘in vivo’ release of chromium ions from BIOLOX® delta bearings in the blood, erythrocytes and urine of patients. Twenty patients implanted with total hip arthroplasty (THA) with BIOLOX® delta-BIOLOX® delta couplings and 21 subjects with no implanted prostheses were studied. Inductively coupled plasma mass spectrometry equipped with dynamic reaction cell was used for analysis. In the THA group the Cr ions values were; in blood mean 0.21 µg/l (±0.09), in serum 0.21 µg/l (±0.12), in normalized erythrocytes 0.13 µg/l (±0.09), in normalized urine 0.12 µg/g creatinine (±0.13). In the control group the Cr ions values were; in blood mean 0.22 µg/l (st dev 0.14), in serum 0.17 µg/l (±0.08), in normalized erythrocytes 0.13 µg/l (±0.11), in normalized urine 0.07 µg/g creatinine (±0.08). The Lab reference values were 0.1-5.0 µg/l for blood, 0.1-0.5 µg/l for serum, 0.14-4.58 µg/l for normalised erythrocytes and 0.05-2.2 µg/l for urine. All samples in both groups resulted in chromium levels within the normal reference range and the safety of BIOLOX® delta ceramics, in terms of chromium ions release, has been demonstrated.
- 11 July 2013
- Published by Taylor & Francis in Clinical Toxicology
- Vol. 51 (7) , 550-556
Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis
Introduction. Vanadium (V) is a minor constituent of the Titanium–Aluminum–Vanadium (TiAlV) alloy currently used in cementless hip prostheses. Present study aimed at verifying the correlation of vanadium levels among different matrices and assessing reference levels of the ion in a population of patients wearing a well-functioning hip prosthesis. Methods. Vanadium was measured using Inductive Coupled Plasma Mass Spectrometry (ICP-MS) in whole blood, serum and urine of 129 patients implanted with a TiAlV-alloy hip prosthesis. Results. The values in the serum were above the upper limit of the reference values in 42% of patients (29% in urine and 13% in whole blood). A good correlation among matrices was observed (p < 0.001). The cohort of patients (N = 32) complaining of pain or in which a loosening or damage to the prosthesis was assessed showed a significantly higher excretion of vanadium in urine as compared with the remaining asymptomatic patients (p = 0.001). The 95th percentile distribution of vanadium in the cohort of patients with a well-functioning prosthesis was 0.3 μg/L in whole blood, 0.5 μg/L in serum and 2.8 μg/L in urine, higher that in the unexposed population, especially for urine. Conclusions. The presence of a prosthesis, even though well-functioning, may cause a possible release of vanadium into the blood and a significant urinary excretion. The reference values of vanadium of the asymptomatic patients with titanium alloy hip prostheses supplied information regarding the background exposure level of the ions and their lower and upper limits.
- 11 July 2013
- Published by Taylor & Francis in Clinical Toxicology
- Vol. 51 (7) , 550-556
Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis
Introduction. Vanadium (V) is a minor constituent of the Titanium–Aluminum–Vanadium (TiAlV) alloy currently used in cementless hip prostheses. Present study aimed at verifying the correlation of vanadium levels among different matrices and assessing reference levels of the ion in a population of patients wearing a well-functioning hip prosthesis. Methods. Vanadium was measured using Inductive Coupled Plasma Mass Spectrometry (ICP-MS) in whole blood, serum and urine of 129 patients implanted with a TiAlV-alloy hip prosthesis. Results. The values in the serum were above the upper limit of the reference values in 42% of patients (29% in urine and 13% in whole blood). A good correlation among matrices was observed (p < 0.001). The cohort of patients (N = 32) complaining of pain or in which a loosening or damage to the prosthesis was assessed showed a significantly higher excretion of vanadium in urine as compared with the remaining asymptomatic patients (p = 0.001). The 95th percentile distribution of vanadium in the cohort of patients with a well-functioning prosthesis was 0.3 μg/L in whole blood, 0.5 μg/L in serum and 2.8 μg/L in urine, higher that in the unexposed population, especially for urine. Conclusions. The presence of a prosthesis, even though well-functioning, may cause a possible release of vanadium into the blood and a significant urinary excretion. The reference values of vanadium of the asymptomatic patients with titanium alloy hip prostheses supplied information regarding the background exposure level of the ions and their lower and upper limits.
- Top Cited Papers
- 5 July 2013
- Published by Taylor & Francis in Annals of Human Biology
- Vol. 40 (6) , 463-471
An estimation of the number of cells in the human body
All living organisms are made of individual and identifiable cells, whose number, together with their size and type, ultimately defines the structure and functions of an organism. While the total cell number of lower organisms is often known, it has not yet been defined in higher organisms. In particular, the reported total cell number of a human being ranges between 10(12) and 10(16) and it is widely mentioned without a proper reference. To study and discuss the theoretical issue of the total number of cells that compose the standard human adult organism. A systematic calculation of the total cell number of the whole human body and of the single organs was carried out using bibliographical and/or mathematical approaches. A current estimation of human total cell number calculated for a variety of organs and cell types is presented. These partial data correspond to a total number of 3.72 × 10(13). Knowing the total cell number of the human body as well as of individual organs is important from a cultural, biological, medical and comparative modelling point of view. The presented cell count could be a starting point for a common effort to complete the total calculation.
- 5 July 2013
- Published by Taylor & Francis in Annals of Human Biology
- Vol. 40 (6) , 463-471
Top Cited PapersAn estimation of the number of cells in the human body
All living organisms are made of individual and identifiable cells, whose number, together with their size and type, ultimately defines the structure and functions of an organism. While the total cell number of lower organisms is often known, it has not yet been defined in higher organisms. In particular, the reported total cell number of a human being ranges between 10(12) and 10(16) and it is widely mentioned without a proper reference. To study and discuss the theoretical issue of the total number of cells that compose the standard human adult organism. A systematic calculation of the total cell number of the whole human body and of the single organs was carried out using bibliographical and/or mathematical approaches. A current estimation of human total cell number calculated for a variety of organs and cell types is presented. These partial data correspond to a total number of 3.72 × 10(13). Knowing the total cell number of the human body as well as of individual organs is important from a cultural, biological, medical and comparative modelling point of view. The presented cell count could be a starting point for a common effort to complete the total calculation.
- 1 May 2013
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 28 (5) , 838-841
Ceramic Debris in Hip Prosthesis: Correlation Between Synovial Fluid and Joint Capsule
- 1 May 2013
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 28 (5) , 838-841
Ceramic Debris in Hip Prosthesis: Correlation Between Synovial Fluid and Joint Capsule
- 15 March 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (6) , 561-566
Uncemented Primary Total Hip Arthroplasty, Presentation of Pain, and Expression of Osteonectin
Osteonectin (ON) is an important matrix glycoprotein highly expressed in bone. In several in vitro and animal model studies, ON was used as indicator of the state of osseointegration of implanted devices. There are, however, no studies on ON expression in the synovial fluid of patients with total hip joint replacement (THJR). The purpose of our study was to determine the ON concentration in synovial fluid from three groups of patients: primary uncemented THJR with hip pain ("pain" group; n = 15) and without pain ("no-pain" group; n = 12), and patients with osteoarthitis scheduled to receive a primary THJR (control group; n = 5). For the prosthesized groups, the statistical nature of the correlation between ON concentration and patient age, in situ life of the THJR, presence of periprosthetic osteolysis, and presence of debris in the synovial fluid was individually investigated. ON concentration was determined using enzyme-linked immunosorbent assay, the presence of periprosthetic osteolysis was established using X-radiography and Engh's criteria, and the presence of debris was determined using digestion and EDX spectroscopy. ON concentration was significantly lower in the "pain" group compared with the "no-pain" one (median values 19.0 and 53.2 ng/mL, respectively). ON concentration in the control group (median value: 16.9 ng/mL) was comparable with that reported in the literature. In the prosthesized groups, ON concentration was not correlated with patient age, in situ life of the prosthesis, presence of periprosthetic osteolysis, or presence of debris in the synovial fluid. Our results suggest that cases of unexplained pain in THJR patients could be treated by paying special attention to the osseointegration status of the implant by using ON concentration as an early indicator of this status.
- 15 March 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (6) , 561-566
Uncemented Primary Total Hip Arthroplasty, Presentation of Pain, and Expression of Osteonectin
Osteonectin (ON) is an important matrix glycoprotein highly expressed in bone. In several in vitro and animal model studies, ON was used as indicator of the state of osseointegration of implanted devices. There are, however, no studies on ON expression in the synovial fluid of patients with total hip joint replacement (THJR). The purpose of our study was to determine the ON concentration in synovial fluid from three groups of patients: primary uncemented THJR with hip pain ("pain" group; n = 15) and without pain ("no-pain" group; n = 12), and patients with osteoarthitis scheduled to receive a primary THJR (control group; n = 5). For the prosthesized groups, the statistical nature of the correlation between ON concentration and patient age, in situ life of the THJR, presence of periprosthetic osteolysis, and presence of debris in the synovial fluid was individually investigated. ON concentration was determined using enzyme-linked immunosorbent assay, the presence of periprosthetic osteolysis was established using X-radiography and Engh's criteria, and the presence of debris was determined using digestion and EDX spectroscopy. ON concentration was significantly lower in the "pain" group compared with the "no-pain" one (median values 19.0 and 53.2 ng/mL, respectively). ON concentration in the control group (median value: 16.9 ng/mL) was comparable with that reported in the literature. In the prosthesized groups, ON concentration was not correlated with patient age, in situ life of the prosthesis, presence of periprosthetic osteolysis, or presence of debris in the synovial fluid. Our results suggest that cases of unexplained pain in THJR patients could be treated by paying special attention to the osseointegration status of the implant by using ON concentration as an early indicator of this status.
- Open Access
- 1 June 2012
- Published by Springer Nature in Scientific Reports
- Vol. 2 (1) , 435
Correlative Light and Scanning X-Ray Scattering Microscopy of Healthy and Pathologic Human Bone Sections
Scanning small and wide angle X-ray scattering (scanning SWAXS) experiments were performed on healthy and pathologic human bone sections. Via crystallographic tools the data were transformed into quantitative images and as such compared with circularly polarized light (CPL) microscopy images. SWAXS and CPL images allowed extracting information of the mineral nanocrystalline phase embedded, with and without preferred orientation, in the collagen fibrils, mapping local changes at sub-osteon resolution. This favorable combination has been applied for the first time to biopsies of dwarfism syndrome and Paget's disease to shed light onto the cortical structure of natural bone in healthy and pathologic sections.
- 1 June 2012
- Published by Springer Nature in Scientific Reports
- Vol. 2 (1) , 435
Open AccessCorrelative Light and Scanning X-Ray Scattering Microscopy of Healthy and Pathologic Human Bone Sections
Scanning small and wide angle X-ray scattering (scanning SWAXS) experiments were performed on healthy and pathologic human bone sections. Via crystallographic tools the data were transformed into quantitative images and as such compared with circularly polarized light (CPL) microscopy images. SWAXS and CPL images allowed extracting information of the mineral nanocrystalline phase embedded, with and without preferred orientation, in the collagen fibrils, mapping local changes at sub-osteon resolution. This favorable combination has been applied for the first time to biopsies of dwarfism syndrome and Paget's disease to shed light onto the cortical structure of natural bone in healthy and pathologic sections.
- 6 April 2012
- Vol. 26 (1) , 51-65
Tissue distribution and metabolism of guanosine in rats following intraperitoneal injection.
Guanosine has long been known as an endogenous purine nucleoside deeply involved in the modulation of several intracellular processes, especially G-protein activity. More recently, it has been reported to act as an extracellular signaling molecule released from neurons and, more markedly, from astrocytes either in basal conditions or after different kinds of stimulation including hypoxia. Moreover, in vivo studies have shown that guanosine plays an important role as both a neuroprotective and neurotrophic agent in the central nervous system. Specific high-affinity binding sites for this nucleoside have been found on membrane preparations from rat brain. The present study was undertaken to investigate the distribution and metabolic profiles of guanosine after administering the nucleoside to gain a better understanding of the biological effects of this potential drug candidate. Rats were given an intraperitonal (i.p.) injection of 2, 4, 8 or 16 mg/kg of guanosine combined with 0.05% of [3H]guanosine. Plasma samples were collected 7.5, 15, 30, 60 and 90 min after the guanosine-mixture administration and analyzed by either a liquid scintillation counter or by HPLC connected to a UV and to an on-line radiochemical detector to measure the levels of guanosine and its metabolic products guanine, xanthine and uric acid. The levels of guanosine, guanine and xanthine were also measured in brain, lung, heart, kidney and liver tissue homogenates at the defined time points after the injection of 8 mg/kg of the guanosine-mixture. We found that the levels of radioactivity in plasma increased linearly in a dose- and time-dependent manner. Guanosine was widely distributed in all tissues examined in the present study, at almost twice its usual levels. In addition, guanine levels dramatically increased in all the organs. Interestingly, enzymatic analysis of the plasma samples showed the presence of a soluble purine nucleoside phosphorylase, a key enzyme in the purine salvage pathway and nucleoside catabolism. Since guanosine has been shown to be neuroprotective and astrocytes have been reported to play critical roles in mediating neuronal survival and functions in different neurodegenerative disorders, we also performed uptake and release.
- 6 April 2012
- Vol. 26 (1) , 51-65
Tissue distribution and metabolism of guanosine in rats following intraperitoneal injection.
Guanosine has long been known as an endogenous purine nucleoside deeply involved in the modulation of several intracellular processes, especially G-protein activity. More recently, it has been reported to act as an extracellular signaling molecule released from neurons and, more markedly, from astrocytes either in basal conditions or after different kinds of stimulation including hypoxia. Moreover, in vivo studies have shown that guanosine plays an important role as both a neuroprotective and neurotrophic agent in the central nervous system. Specific high-affinity binding sites for this nucleoside have been found on membrane preparations from rat brain. The present study was undertaken to investigate the distribution and metabolic profiles of guanosine after administering the nucleoside to gain a better understanding of the biological effects of this potential drug candidate. Rats were given an intraperitonal (i.p.) injection of 2, 4, 8 or 16 mg/kg of guanosine combined with 0.05% of [3H]guanosine. Plasma samples were collected 7.5, 15, 30, 60 and 90 min after the guanosine-mixture administration and analyzed by either a liquid scintillation counter or by HPLC connected to a UV and to an on-line radiochemical detector to measure the levels of guanosine and its metabolic products guanine, xanthine and uric acid. The levels of guanosine, guanine and xanthine were also measured in brain, lung, heart, kidney and liver tissue homogenates at the defined time points after the injection of 8 mg/kg of the guanosine-mixture. We found that the levels of radioactivity in plasma increased linearly in a dose- and time-dependent manner. Guanosine was widely distributed in all tissues examined in the present study, at almost twice its usual levels. In addition, guanine levels dramatically increased in all the organs. Interestingly, enzymatic analysis of the plasma samples showed the presence of a soluble purine nucleoside phosphorylase, a key enzyme in the purine salvage pathway and nucleoside catabolism. Since guanosine has been shown to be neuroprotective and astrocytes have been reported to play critical roles in mediating neuronal survival and functions in different neurodegenerative disorders, we also performed uptake and release.
- 27 January 2012
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 30 (8) , 1312-1320
Synovial fluid microanalysis allows early diagnosis of ceramic hip prosthesis damage
The first clinical sign of ceramic hip prosthesis failure is hip noise. We therefore investigated whether isolation, observation at scanning electron microscopy, and chemical identification with microanalysis of particles from synovial fluid of “noisy hip” could be predictive of ceramic damage. Firstly, the level of “physiological wear” of well functioning ceramic‐on‐ceramic hip prostheses was assessed with this method, then the test was validated as diagnostic method for liner fracture. Twelve asymptomatic patients were enrolled to demonstrate the first aim; 39 cases of noisy hip (GROUP 1), and 7 cases of pending failure not related to ceramic (GROUP 2) were enrolled for the second aim. The analysis of the synovial fluid of the 12 asymptomatic patients allowed to set the “physiological wear” threshold. The analysis of GROUP 1 hips demonstrated the presence of ceramic particles (2 physiological, 12 mild, and 25 strong). The analysis of GROUP 2 showed a physiological presence of ceramic particles in all cases. Revision surgery in GROUP 1 was performed in 16 hips out 25 with strong ceramic particle presence and 2 out of 12 with mild ceramic particle presence. Failure of the ceramic component was evident in all but one of these cases, while the integrity of components was demonstrated in all seven hips of GROUP 2. Synovial fluid microanalysis can be a useful surrogate in predicting ceramic failure particularly when a strong presence of ceramic particles is observed. On the contrary there is not enough evidence to predict ceramic failure in presence of mild positivity. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1312–1320, 2012
- 27 January 2012
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 30 (8) , 1312-1320
Synovial fluid microanalysis allows early diagnosis of ceramic hip prosthesis damage
The first clinical sign of ceramic hip prosthesis failure is hip noise. We therefore investigated whether isolation, observation at scanning electron microscopy, and chemical identification with microanalysis of particles from synovial fluid of “noisy hip” could be predictive of ceramic damage. Firstly, the level of “physiological wear” of well functioning ceramic‐on‐ceramic hip prostheses was assessed with this method, then the test was validated as diagnostic method for liner fracture. Twelve asymptomatic patients were enrolled to demonstrate the first aim; 39 cases of noisy hip (GROUP 1), and 7 cases of pending failure not related to ceramic (GROUP 2) were enrolled for the second aim. The analysis of the synovial fluid of the 12 asymptomatic patients allowed to set the “physiological wear” threshold. The analysis of GROUP 1 hips demonstrated the presence of ceramic particles (2 physiological, 12 mild, and 25 strong). The analysis of GROUP 2 showed a physiological presence of ceramic particles in all cases. Revision surgery in GROUP 1 was performed in 16 hips out 25 with strong ceramic particle presence and 2 out of 12 with mild ceramic particle presence. Failure of the ceramic component was evident in all but one of these cases, while the integrity of components was demonstrated in all seven hips of GROUP 2. Synovial fluid microanalysis can be a useful surrogate in predicting ceramic failure particularly when a strong presence of ceramic particles is observed. On the contrary there is not enough evidence to predict ceramic failure in presence of mild positivity. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1312–1320, 2012
- 16 December 2011
- Published by Wiley in Artificial Organs
- Vol. 36 (5) , 487-491
Monocyte Chemoattractant Protein 1 Expression in Synovial Fluid of Patients With Total Hip Arthroplasty
Monocyte chemoattractant protein 1 (MCP-1) is a member of the chemokines family that stimulates monocyte chemotaxis and whose expression is induced during osseous inflammation. Total hip arthroplasty (THA) now uses ceramic-on-ceramic (cer-cer) or metal-on-metal (met-met) coupling that is considered the bearing of new generation, with improved performance compared with the previous polyethylene bearings. While the ceramic on ceramic is universally considered highly biocompatible, met-met coupling can induce hypersensitivity correlated to immunological response. This study aimed at quantifying the MCP-1 levels in synovial fluid of THA patients with these two articular couplings; synovial fluid of osteoarthritic patients who underwent primary THA was used as a control. The presence of wear particles originating from the prostheses was also assessed in the synovial fluid by scanning electron microscopy and energy dispersive X-ray spectroscopy. The MCP-1 levels in the synovial fluid of 17 patients with met-met coupling were significantly higher than in 13 patients with cer-cer coupling and in seven controls; median MCP-1 level was 919 pg/mL in the cer-cer group, 4274 pg/mL in the met-met group, and 326 pg/mL in the control group. No correlation was found between MCP-1 levels and the presence of wear particles in the synovial fluid, time from surgery, or periprosthetic osteolysis. We conclude that the presence of the prosthesis is responsible for an increase in the level of MCP-1; moreover, the significantly higher level of this chemokine in met-met coupling can be related to inflammatory and possibly hypersensitivity processes induced by metal ions.
- 16 December 2011
- Published by Wiley in Artificial Organs
- Vol. 36 (5) , 487-491
Monocyte Chemoattractant Protein 1 Expression in Synovial Fluid of Patients With Total Hip Arthroplasty
Monocyte chemoattractant protein 1 (MCP-1) is a member of the chemokines family that stimulates monocyte chemotaxis and whose expression is induced during osseous inflammation. Total hip arthroplasty (THA) now uses ceramic-on-ceramic (cer-cer) or metal-on-metal (met-met) coupling that is considered the bearing of new generation, with improved performance compared with the previous polyethylene bearings. While the ceramic on ceramic is universally considered highly biocompatible, met-met coupling can induce hypersensitivity correlated to immunological response. This study aimed at quantifying the MCP-1 levels in synovial fluid of THA patients with these two articular couplings; synovial fluid of osteoarthritic patients who underwent primary THA was used as a control. The presence of wear particles originating from the prostheses was also assessed in the synovial fluid by scanning electron microscopy and energy dispersive X-ray spectroscopy. The MCP-1 levels in the synovial fluid of 17 patients with met-met coupling were significantly higher than in 13 patients with cer-cer coupling and in seven controls; median MCP-1 level was 919 pg/mL in the cer-cer group, 4274 pg/mL in the met-met group, and 326 pg/mL in the control group. No correlation was found between MCP-1 levels and the presence of wear particles in the synovial fluid, time from surgery, or periprosthetic osteolysis. We conclude that the presence of the prosthesis is responsible for an increase in the level of MCP-1; moreover, the significantly higher level of this chemokine in met-met coupling can be related to inflammatory and possibly hypersensitivity processes induced by metal ions.