ASAntoine Simon

Antoine Simon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Antoine Simon has a total of 237 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Towards patient-specific heart modeling for Cardiac Resynchronization Therapy

    by Farheez Mohamed, Wenfeng Ye, Antoine Simon, Michel Rochette, Mathieu Lederlin, Karim El Houari, Philippe Mabo

  • Target density override in pencil beam scanning proton therapy for different motion target delineation: an experimental dosimetry analysis

    by Xianrui Yan, Yungang Wang, Jiabing Gu, Chengqiang Li, Cheng Tao, Antoine Simon, Huazhong Shu, Jian Zhu

    Objective. This study aims to investigate the impact of target density override (TDO) on delivered dose in pencil beam scanning proton therapy (PBSPT) by experimental measurement. Approach. TDO was developed using the density characteristics of all target voxels, employing a sliding window approach. The density-override value was specified as the statistical mean through traversal calculation. Three motion targets were delineated from 3D plain-scan CT (3DpCT), average intensity projection (AIP), and maximum intensity projection (MIP). The prescription proton dose was 200 cGy (RBE). Dose distribution information at the central coronal plane for all plans was quantified by digitizing the film scan. Main results. The target density of AIP and MIP were −315.59 HU (95% CI: −317.35 HU–−313.83 HU), and 76.26 HU (95% CI: 75.59 HU–76.93 HU). The Unconformity Index (UCIunderdose) of the MIP were 0. The MIP and 3DpCT UCIoverdose failed the Mann–Whitney U test (Z = −3.674, −3.606; p = 0). The AIP and MIP prescription dose area for the initial target were 11.42 cm2 (95% CI: 9.71 cm2–13.13 cm2) and 20.90 cm2 (95% CI: 20.24 cm2–21.55 cm2), while increased to 20.07 cm2 (95% CI: 19.36 cm2–20.77 cm2) and decreased to 18.62 cm2 (95% CI: 18.27 cm2–18.98 cm2) for TDO target. The initial and TDO target D98 of AIP, 3DpCT were 185.40 cGy (95% CI: 180.19–190.60 cGy) and 204.54 cGy (95% CI: 194.76–214.33 cGy), 142.46 cGy (95% CI: 137.37–147.55 cGy) and 145.28 cGy (95% CI: 140.44–150.11 cGy). Significance. TDO improves dose coverage within the tumor and reduces the out-field dose. This method provides a promising strategy to optimize dose delivery in PBSPT, especially for tumors affected by respiratory motion.


  • New Method CMR-Guided Endomyocardial Biopsy in Suspicion Context of Isolated Cardiac Sarcoidosis

    by Gilles Barone-Rochette, Erwan Lecesne, Antoine Simon, Mireille Garreau, Celine Fouard


  • Predictive energy management of a hybrid electric vehicle considering engine torque dynamic and transient-related pollutants emissions*

    by Jean Kuchly, Dominique Nelson-Gruel, Antoine Simon, Kristan Gillet, Alain Charlet, Yann Chamaillard, Cédric Nouillant

    The energy management of parallel Hybrid Electric Vehicles (HEVs) is the problematic of determining at each instant the optimal torque split between the Internal Combustion Engine (ICE) and the Electric Motor (EM). Two opposite dynamics are related to this problem: the long dynamic of the battery State Of Charge (SOC) and the short dynamic of the ICE torque and speed variations due to the driver’s power demand. Due to estimation and control errors in the air loop, these ICE variations of torque and speed lead to an imbalance in the air/fuel mix stoichiometry, causing an increase in pollutants generation. This paper aims at solving this issue by computing online an optimal torque split, taking into account the engine transients and their impacts on pollutants generation. The proposed Model Predictive Control (MPC) strategy is based on a Single Layer Perceptron pollutants generation model, trained on experimental data. The control strategy used, when considering a prediction horizon long enough, allows to reduce respectively by 0.9% the fuel consumption, by 23% the CO generation, by 11% the HC generation and by 31% the PM generation at the cost of an S% increase in $\mathrm{NO}_{\mathrm{x}}$ generation.

  • Open Access

    Contour‐guided deep learning based deformable image registration for dose monitoring during CBCT‐guided radiotherapy of prostate cancer

    by Cédric Hemon, Bastien Rigaud, Anais Barateau, Florian Tilquin, Vincent Noblet, David Sarrut, Philippe Meyer, Julien Bert, Renaud De Crevoisier, Antoine Simon

    Purpose: To evaluate deep learning (DL)‐based deformable image registration (DIR) for dose accumulation during radiotherapy of prostate cancer patients.Methods and Materials: Data including 341 CBCTs (209 daily, 132 weekly) and 23 planning CTs from 23 patients was retrospectively analyzed. Anatomical deformation during treatment was estimated using free‐form deformation (FFD) method from Elastix and DL‐based VoxelMorph approaches. The VoxelMorph method was investigated using anatomical scans (VMorph_Sc) or label images (VMorph_Msk), or the combination of both (VMorph_Sc_Msk). Accumulated doses were compared with the planning dose.Results: The DSC ranges, averaged for prostate, rectum and bladder, were 0.60–0.71, 0.67–0.79, 0.93–0.98, and 0.89–0.96 for the FFD, VMorph_Sc, VMorph_Msk, and VMorph_Sc_Msk methods, respectively. When including both anatomical and label images, VoxelMorph estimated more complex deformations resulting in heterogeneous determinant of Jacobian and higher percentage of deformation vector field (DVF) folding (up to a mean value of 1.90% in the prostate). Large differences were observed between DL‐based methods regarding estimation of the accumulated dose, showing systematic overdosage and underdosage of the bladder and rectum, respectively. The difference between planned mean dose and accumulated mean dose with VMorph_Sc_Msk reached a median value of +6.3 Gy for the bladder and −5.1 Gy for the rectum.Conclusion: The estimation of the deformations using DL‐based approach is feasible for male pelvic anatomy but requires the inclusion of anatomical contours to improve organ correspondence. High variability in the estimation of the accumulated dose depending on the deformable strategy suggests further investigation of DL‐based techniques before clinical deployment.


  • Functional Age Estimation Through Neonatal Motion Characterization Using Continuous Video Recordings

    by Sandie Cabon, Raphaël Weber, Antoine Simon, Patrick Pladys, Fabienne Porée, Guy Carrault

    The follow-up of the development of the premature baby is a major component of its clinical care since it has been shown that it can reveal a pathology. However, no method allowing an automated and continuous monitoring of this development has been proposed. Within the framework of the Digi-NewB European project, our team wishes to offer new clinical indices qualifying the maturation of newborns. In this study, we propose a new method to characterize motor activity from video recordings. For this purpose, we have chosen to characterize the motion temporal organization by drawing inspiration from sleep organization. Thus, we propose a fully automatic process allowing to extract motion features and to combine them to estimate a functional age. By investigating two datasets, one of 28.5 hours (manually annotated) from 33 newborns and one of 4,920 hours from 46 newborns, we show that the proposed approach is relevant for monitoring in clinical routine and that the extracted features reflect the maturation of preterm newborns. Indeed, a compact and interpretable model using gestational age and three motion features (mean duration of intervals with motion, total percentage of time spent in motion and number of intervals without motion) was designed to predict post-menstrual age of newborns and showed an admissible mean absolute error of 1.3 weeks. While the temporal organization of motion was not studied clinically due to a lack of technological means, these results open the door to new developments, new investigations and new knowledge on the evolution of motion in newborns.


  • Automatic segmentation for plan-of-the-day selection in CBCT-guided adaptive radiation therapy of cervical cancer

    by Chen Zhang, Caroline Lafond, Anaïs Barateau, Julie Leseur, Bastien Rigaud, Diane Barbara Chan Sock Line, Guanyu Yang, Huazhong Shu, Jean-Louis Dillenseger, Renaud de Crevoisier, et al.

    Objective. Plan-of-the-day (PoD) adaptive radiation therapy (ART) is based on a library of treatment plans, among which, at each treatment fraction, the PoD is selected using daily images. However, this strategy is limited by PoD selection uncertainties. This work aimed to propose and evaluate a workflow to automatically and quantitatively identify the PoD for cervix cancer ART based on daily CBCT images. Approach. The quantification was based on the segmentation of the main structures of interest in the CBCT images (clinical target volume [CTV], rectum, bladder, and bowel bag) using a deep learning model. Then, the PoD was selected from the treatment plan library according to the geometrical coverage of the CTV. For the evaluation, the resulting PoD was compared to the one obtained considering reference CBCT delineations. Main results. In experiments on a database of 23 patients with 272 CBCT images, the proposed method obtained an agreement between the reference PoD and the automatically identified PoD for 91.5% of treatment fractions (99.6% when considering a 5% margin on CTV coverage). Significance. The proposed automatic workflow automatically selected PoD for ART using deep-learning methods. The results showed the ability of the proposed process to identify the optimal PoD in a treatment plan library.


  • Open Access

    Deep Learning-Based Segmentation of Head and Neck Organs-at-Risk with Clinical Partially Labeled Data

    by Lucía Cubero, Joël Castelli, Antoine Simon, Renaud de Crevoisier, Oscar Acosta, Javier Pascau

    Radiotherapy is one of the main treatments for localized head and neck (HN) cancer. To design a personalized treatment with reduced radio-induced toxicity, accurate delineation of organs at risk (OAR) is a crucial step. Manual delineation is time- and labor-consuming, as well as observer-dependent. Deep learning (DL) based segmentation has proven to overcome some of these limitations, but requires large databases of homogeneously contoured image sets for robust training. However, these are not easily obtained from the standard clinical protocols as the OARs delineated may vary depending on the patient’s tumor site and specific treatment plan. This results in incomplete or partially labeled data. This paper presents a solution to train a robust DL-based automated segmentation tool exploiting a clinical partially labeled dataset. We propose a two-step workflow for OAR segmentation: first, we developed longitudinal OAR-specific 3D segmentation models for pseudo-contour generation, completing the missing contours for some patients; with all OAR available, we trained a multi-class 3D convolutional neural network (nnU-Net) for final OAR segmentation. Results obtained in 44 independent datasets showed superior performance of the proposed methodology for the segmentation of fifteen OARs, with an average Dice score coefficient and surface Dice similarity coefficient of 80.59% and 88.74%. We demonstrated that the model can be straightforwardly integrated into the clinical workflow for standard and adaptive radiotherapy.